Try a new search

Format these results:

Searched for:

person:bp31

in-biosketch:yes

Total Results:

81


Flexible, high-resolution cortical arrays with large coverage capture microscale high-frequency oscillations in patients with epilepsy

Barth, Katrina J; Sun, James; Chiang, Chia-Han; Qiao, Shaoyu; Wang, Charles; Rahimpour, Shervin; Trumpis, Michael; Duraivel, Suseendrakumar; Dubey, Agrita; Wingel, Katie E; Voinas, Alex E; Ferrentino, Breonna; Doyle, Werner; Southwell, Derek G; Haglund, Michael M; Vestal, Matthew; Harward, Stephen C; Solzbacher, Florian; Devore, Sasha; Devinsky, Orrin; Friedman, Daniel; Pesaran, Bijan; Sinha, Saurabh R; Cogan, Gregory B; Blanco, Justin; Viventi, Jonathan
OBJECTIVE:Effective surgical treatment of drug-resistant epilepsy depends on accurate localization of the epileptogenic zone (EZ). High-frequency oscillations (HFOs) are potential biomarkers of the EZ. Previous research has shown that HFOs often occur within submillimeter areas of brain tissue and that the coarse spatial sampling of clinical intracranial electrode arrays may limit the accurate capture of HFO activity. In this study, we sought to characterize microscale HFO activity captured on thin, flexible microelectrocorticographic (μECoG) arrays, which provide high spatial resolution over large cortical surface areas. METHODS:We used novel liquid crystal polymer thin-film μECoG arrays (.76-1.72-mm intercontact spacing) to capture HFOs in eight intraoperative recordings from seven patients with epilepsy. We identified ripple (80-250 Hz) and fast ripple (250-600 Hz) HFOs using a common energy thresholding detection algorithm along with two stages of artifact rejection. We visualized microscale subregions of HFO activity using spatial maps of HFO rate, signal-to-noise ratio, and mean peak frequency. We quantified the spatial extent of HFO events by measuring covariance between detected HFOs and surrounding activity. We also compared HFO detection rates on microcontacts to simulated macrocontacts by spatially averaging data. RESULTS:We found visually delineable subregions of elevated HFO activity within each μECoG recording. Forty-seven percent of HFOs occurred on single 200-μm-diameter recording contacts, with minimal high-frequency activity on surrounding contacts. Other HFO events occurred across multiple contacts simultaneously, with covarying activity most often limited to a .95-mm radius. Through spatial averaging, we estimated that macrocontacts with 2-3-mm diameter would only capture 44% of the HFOs detected in our μECoG recordings. SIGNIFICANCE/CONCLUSIONS:These results demonstrate that thin-film microcontact surface arrays with both highresolution and large coverage accurately capture microscale HFO activity and may improve the utility of HFOs to localize the EZ for treatment of drug-resistant epilepsy.
PMID: 37150937
ISSN: 1528-1167
CID: 5503242

Flexural bending to approximate cortical forces exerted by electrocorticography (ECoG) arrays

Witham, Nicholas S; Reiche, Christopher F; Odell, Thomas; Barth, Katrina; Chiang, Chia-Han; Wang, Charles; Dubey, Agrita; Wingel, Katie; Devore, Sasha; Friedman, Daniel; Pesaran, Bijan; Viventi, Jonathan; Solzbacher, Florian
OBJECTIVE:The force that an electrocorticography (ECoG) array exerts on the brain manifests when it bends to match the curvature of the skull and cerebral cortex. This force can negatively impact both short-term and long-term patient outcomes. Here we provide a mechanical characterization of a novel Liquid Crystal Polymer (LCP) ECoG array prototype to demonstrate that its thinner geometry reduces the force potentially applied to the cortex of the brain. APPROACH/METHODS:We built a low-force flexural testing machine to measure ECoG array bending forces, calculate their effective flexural moduli, and approximate the maximum force they could exerted on the human brain. MAIN RESULTS/RESULTS:The LCP ECoG prototype was found to have a maximal force less than 20% that of any commercially available ECoG arrays that was tested. However, as a material, LCP was measured to be as much as 24x more rigid than silicone, which is traditionally used in ECoG arrays. This suggests that the lower maximal force resulted from the prototype's thinner profile (2.9x-3.25x). SIGNIFICANCE/CONCLUSIONS:While decreasing material stiffness can lower the force an ECoG array exhibits, our LCP ECoG array prototype demonstrated that flexible circuit manufacturing techniques can also lower these forces by decreasing ECoG array thickness. Flexural tests of ECoG arrays are necessary to accurately assess these forces, as material properties for polymers and laminates are often scale dependent. As the polymers used are anisotropic, elastic modulus cannot be used to predict ECoG flexural behavior. Accounting for these factors, we used our four-point flexure testing procedure to quantify the forces exerted on the brain by ECoG array bending. With this experimental method, ECoG arrays can be designed to minimize force excerted on the brain, potentially improving both acute and chronic clinical utility.
PMID: 35882223
ISSN: 1741-2552
CID: 5276412

Modeling multiscale causal interactions between spiking and field potential signals during behavior

Wang, Chuanmeizhi; Pesaran, Bijan; Shanechi, Maryam M
PMID: 35073530
ISSN: 1741-2552
CID: 5182222

Intraoperative microseizure detection using a high-density micro-electrocorticography electrode array

Sun, James; Barth, Katrina; Qiao, Shaoyu; Chiang, Chia-Han; Wang, Charles; Rahimpour, Shervin; Trumpis, Michael; Duraivel, Suseendrakumar; Dubey, Agrita; Wingel, Katie E; Rachinskiy, Iakov; Voinas, Alex E; Ferrentino, Breonna; Southwell, Derek G; Haglund, Michael M; Friedman, Allan H; Lad, Shivanand P; Doyle, Werner K; Solzbacher, Florian; Cogan, Gregory; Sinha, Saurabh R; Devore, Sasha; Devinsky, Orrin; Friedman, Daniel; Pesaran, Bijan; Viventi, Jonathan
One-third of epilepsy patients suffer from medication-resistant seizures. While surgery to remove epileptogenic tissue helps some patients, 30-70% of patients continue to experience seizures following resection. Surgical outcomes may be improved with more accurate localization of epileptogenic tissue. We have previously developed novel thin-film, subdural electrode arrays with hundreds of microelectrodes over a 100-1000 mm2 area to enable high-resolution mapping of neural activity. Here, we used these high-density arrays to study microscale properties of human epileptiform activity. We performed intraoperative micro-electrocorticographic recordings in nine patients with epilepsy. In addition, we recorded from four patients with movement disorders undergoing deep brain stimulator implantation as non-epileptic controls. A board-certified epileptologist identified microseizures, which resembled electrographic seizures normally observed with clinical macroelectrodes. Recordings in epileptic patients had a significantly higher microseizure rate (2.01 events/min) than recordings in non-epileptic subjects (0.01 events/min; permutation test, P = 0.0068). Using spatial averaging to simulate recordings from larger electrode contacts, we found that the number of detected microseizures decreased rapidly with increasing contact diameter and decreasing contact density. In cases in which microseizures were spatially distributed across multiple channels, the approximate onset region was identified. Our results suggest that micro-electrocorticographic electrode arrays with a high density of contacts and large coverage are essential for capturing microseizures in epilepsy patients and may be beneficial for localizing epileptogenic tissue to plan surgery or target brain stimulation.
PMCID:9155612
PMID: 35663384
ISSN: 2632-1297
CID: 5283042

Flexible, high-resolution thin-film electrodes for human and animal neural research

Chiang, Chia-Han; Wang, Charles; Barth, Katrina; Rahimpour, Shervin; Trumpis, Michael; Duraivel, Suseendrakumar; Rachinskiy, Iakov; Dubey, Agrita; Wingel, Katie Elizabeth; Wong, Megan; Witham, Nicholas Steven; Odell, Thomas George; Woods, Virginia; Bent, Brinnae; Doyle, Werner; Friedman, Daniel; Bihler, Eckardt; Reiche, Christopher Friedrich; Southwell, Derek; Haglund, Michael M; Friedman, Allan H; Lad, Shivanand; Devore, Sasha; Devinsky, Orrin; Solzbacher, Florian; Pesaran, Bijan; Cogan, Gregory; Viventi, Jonathan
OBJECTIVE:Brain functions such as perception, motor control, learning, and memory arise from the coordinated activity of neuronal assemblies distributed across multiple brain regions. While major progress has been made in understanding the function of individual neurons, circuit interactions remain poorly understood. A fundamental obstacle to deciphering circuit interactions is the limited availability of research tools to observe and manipulate the activity of large, distributed neuronal populations in humans. Here we describe the development, validation, and dissemination of flexible, high-resolution, thin-film (TF) electrodes for recording neural activity in animals and humans. APPROACH/METHODS:We leveraged standard flexible printed-circuit manufacturing processes to build high-resolution TF electrode arrays. We used biocompatible materials to form the substrate (liquid crystal polymer; LCP), metals (Au, PtIr, and Pd), molding (medical-grade silicone), and 3D-printed housing (nylon). We designed a custom, miniaturized, digitizing headstage to reduce the number of cables required to connect to the acquisition system and reduce the distance between the electrodes and the amplifiers. A custom mechanical system enabled the electrodes and headstages to be pre-assembled prior to sterilization, minimizing the setup time required in the operating room. PtIr electrode coatings lowered impedance and enabled stimulation. High-volume, commercial manufacturing enables cost-effective production of LCP-TF electrodes in large quantities. MAIN RESULTS/RESULTS:Our LCP-TF arrays achieve 25× higher electrode density, 20× higher channel count, and 11× reduced stiffness than conventional clinical electrodes. We validated our LCP-TF electrodes in multiple human intraoperative recording sessions and have disseminated this technology to >10 research groups. Using these arrays, we have observed high-frequency neural activity with sub-millimeter resolution. SIGNIFICANCE/CONCLUSIONS:Our LCP-TF electrodes will advance human neuroscience research and improve clinical care by enabling broad access to transformative, high-resolution electrode arrays.
PMID: 34010815
ISSN: 1741-2552
CID: 4877332

Improving scalability in systems neuroscience

Chen, Zhe Sage; Pesaran, Bijan
Emerging technologies to acquire data at increasingly greater scales promise to transform discovery in systems neuroscience. However, current exponential growth in the scale of data acquisition is a double-edged sword. Scaling up data acquisition can speed up the cycle of discovery but can also misinterpret the results or possibly slow down the cycle because of challenges presented by the curse of high-dimensional data. Active, adaptive, closed-loop experimental paradigms use hardware and algorithms optimized to enable time-critical computation to provide feedback that interprets the observations and tests hypotheses to actively update the stimulus or stimulation parameters. In this perspective, we review important concepts of active and adaptive experiments and discuss how selectively constraining the dimensionality and optimizing strategies at different stages of discovery loop can help mitigate the curse of high-dimensional data. Active and adaptive closed-loop experimental paradigms can speed up discovery despite an exponentially increasing data scale, offering a road map to timely and iterative hypothesis revision and discovery in an era of exponential growth in neuroscience.
PMID: 33831347
ISSN: 1097-4199
CID: 4839702

Modelling and prediction of the dynamic responses of large-scale brain networks during direct electrical stimulation

Yang, Yuxiao; Qiao, Shaoyu; Sani, Omid G; Sedillo, J Isaac; Ferrentino, Breonna; Pesaran, Bijan; Shanechi, Maryam M
Direct electrical stimulation can modulate the activity of brain networks for the treatment of several neurological and neuropsychiatric disorders and for restoring lost function. However, precise neuromodulation in an individual requires the accurate modelling and prediction of the effects of stimulation on the activity of their large-scale brain networks. Here, we report the development of dynamic input-output models that predict multiregional dynamics of brain networks in response to temporally varying patterns of ongoing microstimulation. In experiments with two awake rhesus macaques, we show that the activities of brain networks are modulated by changes in both stimulation amplitude and frequency, that they exhibit damping and oscillatory response dynamics, and that variabilities in prediction accuracy and in estimated response strength across brain regions can be explained by an at-rest functional connectivity measure computed without stimulation. Input-output models of brain dynamics may enable precise neuromodulation for the treatment of disease and facilitate the investigation of the functional organization of large-scale brain networks.
PMID: 33526909
ISSN: 2157-846x
CID: 4777102

Sufficient sampling for kriging prediction of cortical potential in rat, monkey, and human µECoG

Trumpis, Michael; Chiang, Chia-Han; Orsborn, Amy L; Bent, Brinnae; Li, Jinghua; Rogers, John A; Pesaran, Bijan; Cogan, Gregory; Viventi, Jonathan
Objective. Large channel count surface-based electrophysiology arrays (e.g. µECoG) are high-throughput neural interfaces with good chronic stability. Electrode spacing remains ad hoc due to redundancy and nonstationarity of field dynamics. Here, we establish a criterion for electrode spacing based on the expected accuracy of predicting unsampled field potential from sampled sites.Approach. We applied spatial covariance modeling and field prediction techniques based on geospatial kriging to quantify sufficient sampling for thousands of 500 ms µECoG snapshots in human, monkey, and rat. We calculated a probably approximately correct (PAC) spacing based on kriging that would be required to predict µECoG fields at≤10% error for most cases (95% of observations).Main results. Kriging theory accurately explained the competing effects of electrode density and noise on predicting field potential. Across five frequency bands from 4-7 to 75-300 Hz, PAC spacing was sub-millimeter for auditory cortex in anesthetized and awake rats, and posterior superior temporal gyrus in anesthetized human. At 75-300 Hz, sub-millimeter PAC spacing was required in all species and cortical areas.Significance. PAC spacing accounted for the effect of signal-to-noise on prediction quality and was sensitive to the full distribution of non-stationary covariance states. Our results show that µECoG arrays should sample at sub-millimeter resolution for applications in diverse cortical areas and for noise resilience.
PMCID:8058280
PMID: 33326943
ISSN: 1741-2552
CID: 4851932

Multiscale low-dimensional motor cortical state dynamics predict naturalistic reach-and-grasp behavior

Abbaspourazad, Hamidreza; Choudhury, Mahdi; Wong, Yan T; Pesaran, Bijan; Shanechi, Maryam M
Motor function depends on neural dynamics spanning multiple spatiotemporal scales of population activity, from spiking of neurons to larger-scale local field potentials (LFP). How multiple scales of low-dimensional population dynamics are related in control of movements remains unknown. Multiscale neural dynamics are especially important to study in naturalistic reach-and-grasp movements, which are relatively under-explored. We learn novel multiscale dynamical models for spike-LFP network activity in monkeys performing naturalistic reach-and-grasps. We show low-dimensional dynamics of spiking and LFP activity exhibited several principal modes, each with a unique decay-frequency characteristic. One principal mode dominantly predicted movements. Despite distinct principal modes existing at the two scales, this predictive mode was multiscale and shared between scales, and was shared across sessions and monkeys, yet did not simply replicate behavioral modes. Further, this multiscale mode's decay-frequency explained behavior. We propose that multiscale, low-dimensional motor cortical state dynamics reflect the neural control of naturalistic reach-and-grasp behaviors.
PMCID:7840738
PMID: 33504797
ISSN: 2041-1723
CID: 4777042

Modeling behaviorally relevant neural dynamics enabled by preferential subspace identification

Sani, Omid G; Abbaspourazad, Hamidreza; Wong, Yan T; Pesaran, Bijan; Shanechi, Maryam M
Neural activity exhibits complex dynamics related to various brain functions, internal states and behaviors. Understanding how neural dynamics explain specific measured behaviors requires dissociating behaviorally relevant and irrelevant dynamics, which is not achieved with current neural dynamic models as they are learned without considering behavior. We develop preferential subspace identification (PSID), which is an algorithm that models neural activity while dissociating and prioritizing its behaviorally relevant dynamics. Modeling data in two monkeys performing three-dimensional reach and grasp tasks, PSID revealed that the behaviorally relevant dynamics are significantly lower-dimensional than otherwise implied. Moreover, PSID discovered distinct rotational dynamics that were more predictive of behavior. Furthermore, PSID more accurately learned behaviorally relevant dynamics for each joint and recording channel. Finally, modeling data in two monkeys performing saccades demonstrated the generalization of PSID across behaviors, brain regions and neural signal types. PSID provides a general new tool to reveal behaviorally relevant neural dynamics that can otherwise go unnoticed.
PMID: 33169030
ISSN: 1546-1726
CID: 4673522