Try a new search

Format these results:

Searched for:

person:hafiza01

in-biosketch:yes

Total Results:

2


Feasibility of tele-guided patient-administered lung ultrasound in heart failure

Pratzer, Ariella; Yuriditsky, Eugene; Saraon, Tajinderpal; Janjigian, Michael; Hafiz, Ali; Tsay, Jun Chieh J.; Boodram, Pamela; Jejurikar, Nikita; Sauthoff, Harald
Background: Readmission rates for heart failure remain high, and affordable technology for early detection of heart failure decompensation in the home environment is needed. Lung ultrasound has been shown to be a sensitive tool to detect pulmonary congestion due to heart failure, and monitoring patients in their home environment with lung ultrasound could help to prevent hospital admissions. The aim of this project was to investigate whether patient-performed tele-guided ultrasound in the home environment using an ultraportable device is feasible.Affiliations: Journal instruction requires a country for affiliations; however, these are missing in affiliations [1, 2]. Please verify if the provided country are correct and amend if necessary.Correct Methods: Stable ambulatory patients with heart failure received a handheld ultrasound probe connected to a smart phone or tablet. Instructions for setup were given in person during a clinic visit or over the phone. During each ultrasound session, patients obtained six ultrasound clips from the anterior and lateral chest with verbal and visual tele-guidance from an ultrasound trained clinician. Patients also reported their weight and degree of dyspnea, graded on a 5-point scale. Two independent reviewers graded the ultrasound clips based on the visibility of the pleural line and A or B lines. Results: Eight stable heart failure patients each performed 10"“12 lung ultrasound examinations at home under remote guidance within a 1-month period. There were no major technical difficulties. A total of 89 ultrasound sessions resulted in 534 clips of which 88% (reviewer 1) and 84% (reviewer 2) were interpretable. 91% of ultrasound sessions produced interpretable clips bilaterally from the lateral chest area, which is most sensitive for the detection of pulmonary congestion. The average time to complete an ultrasound session was 5 min with even shorter recording times for the last session. All patients were clinically stable during the study period and no false positive B-lines were observed. Conclusions: In this feasibility study, patients were able to produce interpretable lung ultrasound exams in more than 90% of remotely supervised sessions in their home environment. Larger studies are needed to determine whether remotely guided lung ultrasound could be useful to detect heart failure decompensation early in the home environment.
SCOPUS:85148017423
ISSN: 2524-8987
CID: 5425762

Submassive pulmonary embolism with a right heart thrombus [Case Report]

Yan, Winnie; Gunther, Ingrid; Hafiz, Ali; Goldenberg, Ronald
A 49-year-old woman presented to the hospital with shortness of breath 2 weeks after a left total hip replacement. She was found to have a submassive pulmonary embolism (PE), with her case complicated by the detection of a large mobile clot in transit extending through a patent foramen ovale between the right and left atria. The presence of this free-floating right heart thrombus (FFRHT) increases her risks of stroke and mortality, yet the optimal approach to her treatment was unclear. Ultimately, intravenous tissue plasminogen activator was administered with resolution of the clot. Treatment was complicated by haemodynamically insignificant bleeding at the site of recent surgery. Herein, we further discuss the implications and treatment options for patients with an FFRHT in the setting of an acute PE.
PMCID:8296774
PMID: 34290009
ISSN: 1757-790x
CID: 5003912