Try a new search

Format these results:

Searched for:

person:spinem01

Total Results:

20


Comparison of combined substrate-based mapping techniques to identify critical sites for ventricular tachycardia ablation

Khan, Hassan; Bonvissuto, Matthew R; Rosinski, Elizabeth; Shokr, Mohamed; Metcalf, Kara; Jankelson, Lior; Kushnir, Alexander; Park, David S; Bernstein, Scott A; Spinelli, Michael A; Aizer, Anthony; Holmes, Douglas; Chinitz, Larry A; Barbhaiya, Chirag R
BACKGROUND:Established electroanatomic mapping techniques for substrate mapping for ventricular tachycardia (VT) ablation includes voltage mapping, isochronal late activation mapping (ILAM), and fractionation mapping. Omnipolar mapping (Abbott Medical, Inc.) is a novel optimized bipolar electrogram creation technique with integrated local conduction velocity annotation. The relative utilities of these mapping techniques are unknown. OBJECTIVE:The purpose of this study was to evaluate the relative utility of various substrate mapping techniques for the identification of critical sites for VT ablation. METHODS:Electroanatomic substrate maps were created and retrospectively analyzed in 27 patients in whom 33 VT critical sites were identified. RESULTS:. CONCLUSION/CONCLUSIONS:ILAM, fractionation, and CV mapping each identified distinct critical sites and provided a smaller area of interest than did voltage mapping alone. The sensitivity of novel mapping modalities improved with greater local point density.
PMID: 36863636
ISSN: 1556-3871
CID: 5462332

Temporal trends in atrial fibrillation ablation procedures at an academic medical center: 2011-2021

Kushnir, Alexander; Barbhaiya, Chirag R; Aizer, Anthony; Jankelson, Lior; Holmes, Douglas; Knotts, Robert; Park, David; Spinelli, Michael; Bernstein, Scott; Chinitz, Larry A
INTRODUCTION/BACKGROUND:Radiofrequency ablation technology for treating atrial fibrillation (AF) has evolved rapidly over the past decade. We investigated the impact of technological and procedural advances on procedure times and ablation outcomes at a major academic medical center over a 10-year period. METHODS:Clinical data was collected from patients who presented to NYU Langone Health between 2011 and 2021 for a first-time AF ablation. Time to redo AF ablation or direct current cardioversion (DCCV) for recurrent AF during a 3-year follow-up period was determined and correlated with ablation technology and practices, antiarrhythmic medications, and patient comorbid conditions. RESULTS:From 2011 to 2021, the cardiac electrophysiology lab adopted irrigated-contact force ablation catheters, high-power short duration ablation lesions, steady-pacing, jet ventilation, and eliminated stepwise linear ablation for AF ablation. During this time the number of first time AF ablations increased from 403 to 1074, the percentage of patients requiring repeat AF-related intervention within 3-years of the index procedure dropped from 22% to 14%, mean procedure time decreased from 271 ± 65 to 135 ± 36 min, and mean annual major adverse event rate remained constant at 1.1 ± 0.5%. Patient comorbid conditions increased during this time period and antiarrhythmic use was unchanged. CONCLUSION/CONCLUSIONS:Rates of redo-AF ablation or DCCV following an initial AF ablation at a single center decreased 36% over a 10-year period. Procedural and technological changes likely contributed to this improvement, despite increased AF related comorbidities.
PMID: 36738147
ISSN: 1540-8167
CID: 5420652

Outcomes and atrial substrate analysis in patients with HIV undergoing atrial fibrillation ablation

Cheng, Austin; Qiu, Jessica; Barbhaiya, Chirag; Garber, Leonid; Holmes, Douglas; Jankelson, Lior; Kushnir, Alexander; Knotts, Robert; Bernstein, Scott; Park, David; Spinelli, Michael; Chinitz, Larry; Aizer, Anthony
INTRODUCTION/BACKGROUND:Patients with HIV infection have increased risk of atrial fibrillation, but the pathophysiologic mechanisms and the utility of catheter ablation in this population are not well-studied. We aimed to characterize outcomes of atrial fibrillation ablation and left atrial substrate in patients with HIV. METHODS:The study was a retrospective propensity score-matched analysis of patients with and without HIV undergoing atrial fibrillation ablation. A search was performed in the electronic medical record for all patients with HIV who received initial atrial fibrillation ablation from 2011 to 2020. After calculating propensity scores for HIV, matching was performed with patients without HIV by using nearest-neighbor matching without replacement in a 1:2 ratio. The primary outcome was freedom from atrial arrhythmia and secondary outcomes were freedom from atrial fibrillation, freedom from atrial tachycardia, and freedom from repeat ablation, compared by log-rank analysis. The procedures of patients with HIV who underwent repeat ablation at our institution were further analyzed for etiology of recurrence. To further characterize the left atrial substrate, a subsequent case-control analysis was then performed for a set of randomly chosen 10 patients with HIV matched with 10 without HIV to compare minimum and maximum voltage at nine pre-specified regions of the left atrium. RESULTS:Twenty-seven patients with HIV were identified. All were prescribed antiretroviral therapy at time of ablation. These patients were matched with 54 patients without HIV by propensity score. 86.4% of patients with HIV and 76.9% of controls were free of atrial fibrillation or atrial tachycardia at 1 year (p = .509). Log-rank analysis showed no difference in freedom from atrial arrhythmia (p value .971), atrial fibrillation (p-value .346), atrial tachycardia (p value .306), or repeat ablation (p value .401) after initial atrial fibrillation ablation in patients with HIV compared to patients without HIV. In patients with HIV with recurrent atrial fibrillation, the majority had pulmonary vein reconnection (67%). There were no significant differences in minimum or maximum voltage at any of the nine left atrial regions between the matched patients with and without HIV. CONCLUSIONS:Ablation to treat atrial fibrillation in patients with HIV, but without overt AIDS is frequently successful therapy. The majority of patients with recurrence of atrial fibrillation had pulmonary vein reconnection, suggesting infrequent nonpulmonary vein substrate. In this population, the left atrial voltage in patients with HIV is similar to that of patients without HIV. These findings suggest that the pulmonary veins remain a critical component to the initiation and maintenance of atrial fibrillation in patients with HIV.
PMID: 36511474
ISSN: 1540-8167
CID: 5382032

Subcutaneous Versus Transvenous Implantable Defibrillator in Patients with Hypertrophic Cardiomyopathy

Jankelson, Lior; Garber, Leonid; Sherrid, Mark; Massera, Daniele; Jones, Paul; Barbhaiya, Chirag; Holmes, Douglas; Knotts, Robert; Bernstein, Scott; Spinelli, Michael; Park, David; Aizer, Anthony; Chinitz, Larry
BACKGROUND:Hypertrophic cardiomyopathy (HCM) is the most prevalent inherited cardiomyopathy. Implantable Cardioverter Defibrillator (ICD) is important for prevention of sudden cardiac death (SCD) in patients at high risk. In recent years the subcutaneous ICD (S-ICD) has emerged as a viable alternative to the transvenous ICD (TV-ICD). The S-ICD does not require intravascular access, but cannot provide antitachycardia pacing therapy (ATP). OBJECTIVE:To assess the real world incidence of ICD therapy in patients with HCM implanted with TV-ICD versus S-ICD. METHODS:We compared the incidence of ATP and shock therapies between all HCM patients with S-ICD and TV-ICD enrolled in the Boston Scientific ALTITUDE database. Cumulative Kaplan Meier incidence was used to compare therapy free survival and Cox proportional hazard ratios were calculated. We performed an unmatched as well as propensity match analysis. RESULTS:We included 2047 patients with TV-ICD and 626 patients with S-ICD followed for an average of 1650.5±1038.5 and 933.4±550.6 days, respectively. Patients with HCM and TV-ICD had significantly higher rate of device therapy as compared to those with S-ICD (32.7 vs. 14.5 therapies /100 patient year; p<0.001), driven by a high incidence of ATP therapy in the TV-ICD group which accounted for more than 67% of therapies delivered. Shock incidence was similar between groups, both in the general and in the matched cohorts. CONCLUSIONS:Patients with HCM and S-ICD had significantly lower therapy rate than patients with TV-ICD without difference in shock therapy, suggesting potentially unnecessary ATP therapy. Empiric ATP programing in patients with HCM may be unbeneficial.
PMID: 35038570
ISSN: 1556-3871
CID: 5131402

Outcomes of posterior wall isolation with pulmonary vein isolation for paroxysmal atrial fibrillation

Jankelson, Lior; Garber, Leonid; Shulman, Eric; Cohen, Roi Bar; Peterson, Connor; Wadhwani, Lalit; Nadeau-Routhier, Charles; Xia, Yuhe; Barbhaiya, Chirag; Holmes, Douglas; Knotts, Robert; Bernstein, Scott; Kushnir, Alexander; Spinelli, Michael; Park, David; Aizer, Anthony; Chinitz, Larry
BACKGROUND:Prior studies have shown that addition of posterior wall isolation (PWI) may reduce atrial fibrillation recurrence in patients with persistent atrial fibrillation. No data on PWI in paroxysmal AF (pAF) patients with normal left atrial voltage is available, to date. OBJECTIVE:This study sought to evaluate the efficacy of PWI in addition to pulmonary vein isolation (PVI) in patients presenting with pAF and normal left atrial voltage. METHODS:Consecutive patient registry analysis was performed on all patients with pAF and normal left atrial voltage undergoing initial radiofrequency ablation from November 1, 2018 to November 15, 2019. Primary endpoint was recurrence of atrial arrhythmia including AF, atrial tachycardia (AT) or atrial flutter (AFL). RESULTS:A total of 321 patients were studied, 214 in the PVI group and 107 in the PWI+PVI group. Recurrence of any atrial arrhythmia occurred in 18.2% of patients in the PVI group and 16.8% in the PVI+PWI cohort (p=0.58). At one year, recurrence was 14.0% in the PVI group and 15.0% in the PWI+PVI group (p=0.96). There was a lower AT/AFL recurrence in the PVI+PWI group, not reaching significance (3.7% in the PWI+PVI group vs. 7.9% in PVI group, p=0.31). Need for carina lesions predicted recurrence in the PVI-only group. CONCLUSIONS:Addition of PWI to PVI in pAF patients undergoing their first ablation did not reduce the frequency of atrial arrhythmia recurrence. This warrants further study in a prospective trial. This article is protected by copyright. All rights reserved.
PMID: 34911157
ISSN: 1540-8167
CID: 5093072

Rebooting atrial fibrillation ablation in the COVID-19 pandemic

Barbhaiya, Chirag R; Wadhwani, Lalit; Manmadhan, Arun; Selim, Ahmed; Knotts, Robert J; Kushnir, Alexander; Spinelli, Michael; Jankelson, Lior; Bernstein, Scott; Park, David; Holmes, Douglas; Aizer, Anthony; Chinitz, Larry A
PURPOSE/OBJECTIVE:Catheter ablation procedures for atrial fibrillation (AF) were significantly curtailed during the peak of coronavirus disease 2019 (COVID-19) pandemic to conserve healthcare resources and limit exposure. There is little data regarding peri-procedural outcomes of medical procedures during the COVID-19 pandemic. We enacted protocols to safely reboot AF ablation while limiting healthcare resource utilization. We aimed to evaluate acute and subacute outcomes of protocols instituted for reboot of AF ablation during the COVID-19 pandemic. METHODS:Perioperative healthcare utilization and acute procedural outcomes were analyzed for consecutive patients undergoing AF ablation under COVID-19 protocols (2020 cohort; n=111) and compared to those of patients who underwent AF ablation during the same time period in 2019 (2019 cohort; n=200). Newly implemented practices included preoperative COVID-19 testing, selective transesophageal echocardiography (TEE), utilization of venous closure, and same-day discharge when clinically appropriate. RESULTS:Pre-ablation COVID-19 testing was positive in 1 of 111 patients. There were 0 cases ablation-related COVID-19 transmission and 0 major complications in either cohort. Pre-procedure TEE was performed in significantly fewer 2020 cohort patients compared to the 2019 cohort patients (68.4% vs. 97.5%, p <0.001, respectively) despite greater prevalence of persistent arrhythmia in the 2020 cohort. Same-day discharge was achieved in 68% of patients in the 2020 cohort, compared to 0% of patients in the 2019 cohort. CONCLUSIONS:Our findings demonstrate the feasibility of safe resumption of complex electrophysiology procedures during the COVID-19 pandemic, reducing healthcare utilization and maintaining quality of care. Protocols instituted may be generalizable to other types of procedures and settings.
PMID: 33543350
ISSN: 1572-8595
CID: 4776662

Time to diagnosis of acute complications after cardiovascular implantable electronic device insertion and optimal timing of discharge within the first 24 hours

Wadhwani, Lalit; Occhipinti, Karen; Selim, Ahmed; Manmadhan, Arun; Kushnir, Alexander; Barbhaiya, Chirag; Jankelson, Lior; Holmes, Douglas; Bernstein, Scott; Spinelli, Michael; Knotts, Robert; Park, David S; Chinitz, Larry A; Aizer, Anthony
BACKGROUND:More than 3 million cardiovascular implantable electronic devices (CIEDs) are implanted annually. There are minimal data regarding the timing of diagnosis of acute complications after implantation. It remains unclear whether patients can be safely discharged less than 24 hours postimplantation. OBJECTIVE:The purpose of this study was to determine the precise timing of acute complication diagnosis after CIED implantation and optimal timing for same-day discharge. METHODS:A retrospective cohort analysis of adults 18 years or older who underwent CIED implantation at a large urban quaternary care medical center between June 1, 2015, and March 30, 2020, was performed. Standard of care included overnight observation and chest radiography 6 and 24 hours postprocedure. Medical records were reviewed for the timing of diagnosis of acute complications. Acute complications included pneumothorax, hemothorax, pericardial effusion, lead dislodgment, and implant site hematoma requiring surgical intervention. RESULTS:A total of 2421 patients underwent implantation. Pericardial effusion or cardiac tamponade was diagnosed in 13 patients (0.53%), pneumothorax or hemothorax in 19 patients (0.78%), lead dislodgment in 11 patients (0.45%), and hematomas requiring surgical intervention in 5 patients (0.2%). Of the 48 acute complications, 43 (90%) occurred either within 6 hours or more than 24 hours after the procedure. Only 3 acute complications identified between 6 and 24 hours required intervention during the index hospitalization (0.12% of all cases). CONCLUSION/CONCLUSIONS:Most acute complications are diagnosed either within the first 6 hours or more than 24 hours after implantation. With rare exception, patients can be considered for discharge after 6 hours of appropriate monitoring.
PMID: 34517119
ISSN: 1556-3871
CID: 5026662

ICD shocks and complications in patients with inherited arrhythmia syndromes

Siskin, Matthew; Cerrone, Marina; Shokr, Mohamed; Aizer, Anthony; Barbhaiya, Chirag; Dai, Matthew; Bernstein, Scott; Holmes, Douglas; Knotts, Robert; Park, David S; Spinelli, Michael; Chinitz, Larry A; Jankelson, Lior
Background/UNASSIGNED:There is limited information on the long-term outcomes of ICDs in patients with inherited arrhythmia syndromes. Methods/UNASSIGNED:Prospective registry study of inherited arrhythmia patients with an ICD. Incidence of therapies and complications were measured as 5-year cumulative incidence proportions and analyzed with the Kaplan-Meier method. Incidence was compared by device indication, diagnosis type and device type. Cox-regression analysis was used to identify predictors of appropriate shock and device complication. Results/UNASSIGNED:123 patients with a mean follow up of 6.4 ± 4.8 years were included. The incidence of first appropriate shock was 56.52% vs 24.44%, p < 0.05 for cardiomyopathy and channelopathy patients, despite similar ejection fraction (61% vs 60%, p = 0.6). The incidence of first inappropriate shock was 13.46% vs 56.25%, p < 0.01 for single vs. multi-lead devices. The incidence of first lead complication was higher for multi-lead vs. single lead devices, 43.75% vs. 17.31%, p = 0.04. Patients with an ICD for secondary prevention were more likely to receive an appropriate shock than those with primary prevention indication (HR 2.21, CI 1.07-4.56, p = 0.03). Multi-lead devices were associated with higher risk of inappropriate shock (HR 3.99, CI 1.27-12.52, p = 0.02), with similar appropriate shock risk compared to single lead devices. In 26.5% of patients with dual chamber devices, atrial sensing or pacing was not utilized. Conclusion/UNASSIGNED:The rate of appropriate therapies and ICD complications in patients with inherited arrhythmia is high, particularly in cardiomyopathies with multi-lead devices. Risk-benefit ratio should be carefully considered when assessing the indication and type of device in this population.
PMCID:8569698
PMID: 34765721
ISSN: 2352-9067
CID: 5050742

Optimizer Smart System for the treatment of chronic heart failure: Overview of its safety and efficacy

Chera, Habib Hymie; Michelakis, Nickolaos; Al-Sadawi, Mohammed; Spinelli, Michael
PMID: 34323128
ISSN: 1745-2422
CID: 4949912

QT interval dynamics and triggers for QT prolongation immediately following cardiac arrest

Cohen, Roi Bar; Dai, Matthew; Aizer, Anthony; Barbhaiya, Chirag; Peterson, Connor; Bernstein, Scott; Park, David; Spinelli, Michael; Chinitz, Larry; Jankelson, Lior
BACKGROUND:The prolongation in QT interval typically observed following cardiac arrest is considered to be multifactorial and induced by external triggers such as hypothermia therapy and exposure to antiarrhythmic medications. OBJECTIVE:To evaluate the corrected QT interval (QTc) dynamics in the first 10 days following cardiac arrest with respect to the etiology of arrest, hypothermia and QT prolonging medications. METHODS:We enrolled 104 adult survivors of cardiac arrest, where daily ECG was available for at least 3 days. We followed their QT and QRS intervals for the first 10 days of hospitalization. We used both Bazett and Fridericia formulas to correct for heart rate. For patients with QRS < 120 we analyzed the QTc interval (n = 90) and for patients with QRS > 120 ms we analyzed the JTc (n = 104) vs. including only the narrow QRS samples (n = 89). We stratified patients by 3 groups: (1) presence of ischemic heart disease (IHD) (2) treatment with hypothermia protocol, and (3) treatment with QTc prolonging medications. Additionally, genetic information obtained during hospitalization was analyzed. RESULTS:QTc and JTc intervals were significantly prolonged in the first 6 days. Maximal QTc/JTc prolongation was observed in day 2 (QTcB = 497 ± 55). There were no differences in daily QTc/JTc and QRS intervals in the first 2 days post arrest between patients with or without hypothermia induction but such difference. All subgroups demonstrated significantly prolonged QTc/JTc interval regardless of the presence of IHD, hypothermia protocol or QTc prolonging medication exposure. Our results were consistent for both Bazetts' and Frediricia correction and for any QRS duration. Prolongation of the JTcB beyond 382 ms after day 3 predicted sustained QTc/JTc prolongation beyond day 6 with an ROC of 0.78. CONCLUSIONS:QTc/JTc interval is significantly and independently prolonged post SCA, regardless of known QT prolonging triggers. Normalization of the QTc post cardiac arrest should be expected only after day 6 of hospitalization. Assessment of the QTc for adjudication of the etiology of arrest or for monitoring the effect of QT prolonging medications may be unreliable.
PMID: 33652119
ISSN: 1873-1570
CID: 4801392