Try a new search

Format these results:

Searched for:

person:bernss03

in-biosketch:true

Total Results:

66


Time to diagnosis of acute complications after cardiovascular implantable electronic device insertion and optimal timing of discharge within the first 24 hours

Wadhwani, Lalit; Occhipinti, Karen; Selim, Ahmed; Manmadhan, Arun; Kushnir, Alexander; Barbhaiya, Chirag; Jankelson, Lior; Holmes, Douglas; Bernstein, Scott; Spinelli, Michael; Knotts, Robert; Park, David S; Chinitz, Larry A; Aizer, Anthony
BACKGROUND:More than 3 million cardiovascular implantable electronic devices (CIEDs) are implanted annually. There are minimal data regarding the timing of diagnosis of acute complications after implantation. It remains unclear whether patients can be safely discharged less than 24 hours postimplantation. OBJECTIVE:The purpose of this study was to determine the precise timing of acute complication diagnosis after CIED implantation and optimal timing for same-day discharge. METHODS:A retrospective cohort analysis of adults 18 years or older who underwent CIED implantation at a large urban quaternary care medical center between June 1, 2015, and March 30, 2020, was performed. Standard of care included overnight observation and chest radiography 6 and 24 hours postprocedure. Medical records were reviewed for the timing of diagnosis of acute complications. Acute complications included pneumothorax, hemothorax, pericardial effusion, lead dislodgment, and implant site hematoma requiring surgical intervention. RESULTS:A total of 2421 patients underwent implantation. Pericardial effusion or cardiac tamponade was diagnosed in 13 patients (0.53%), pneumothorax or hemothorax in 19 patients (0.78%), lead dislodgment in 11 patients (0.45%), and hematomas requiring surgical intervention in 5 patients (0.2%). Of the 48 acute complications, 43 (90%) occurred either within 6 hours or more than 24 hours after the procedure. Only 3 acute complications identified between 6 and 24 hours required intervention during the index hospitalization (0.12% of all cases). CONCLUSION/CONCLUSIONS:Most acute complications are diagnosed either within the first 6 hours or more than 24 hours after implantation. With rare exception, patients can be considered for discharge after 6 hours of appropriate monitoring.
PMID: 34517119
ISSN: 1556-3871
CID: 5026662

ICD shocks and complications in patients with inherited arrhythmia syndromes

Siskin, Matthew; Cerrone, Marina; Shokr, Mohamed; Aizer, Anthony; Barbhaiya, Chirag; Dai, Matthew; Bernstein, Scott; Holmes, Douglas; Knotts, Robert; Park, David S; Spinelli, Michael; Chinitz, Larry A; Jankelson, Lior
Background/UNASSIGNED:There is limited information on the long-term outcomes of ICDs in patients with inherited arrhythmia syndromes. Methods/UNASSIGNED:Prospective registry study of inherited arrhythmia patients with an ICD. Incidence of therapies and complications were measured as 5-year cumulative incidence proportions and analyzed with the Kaplan-Meier method. Incidence was compared by device indication, diagnosis type and device type. Cox-regression analysis was used to identify predictors of appropriate shock and device complication. Results/UNASSIGNED:123 patients with a mean follow up of 6.4 ± 4.8 years were included. The incidence of first appropriate shock was 56.52% vs 24.44%, p < 0.05 for cardiomyopathy and channelopathy patients, despite similar ejection fraction (61% vs 60%, p = 0.6). The incidence of first inappropriate shock was 13.46% vs 56.25%, p < 0.01 for single vs. multi-lead devices. The incidence of first lead complication was higher for multi-lead vs. single lead devices, 43.75% vs. 17.31%, p = 0.04. Patients with an ICD for secondary prevention were more likely to receive an appropriate shock than those with primary prevention indication (HR 2.21, CI 1.07-4.56, p = 0.03). Multi-lead devices were associated with higher risk of inappropriate shock (HR 3.99, CI 1.27-12.52, p = 0.02), with similar appropriate shock risk compared to single lead devices. In 26.5% of patients with dual chamber devices, atrial sensing or pacing was not utilized. Conclusion/UNASSIGNED:The rate of appropriate therapies and ICD complications in patients with inherited arrhythmia is high, particularly in cardiomyopathies with multi-lead devices. Risk-benefit ratio should be carefully considered when assessing the indication and type of device in this population.
PMCID:8569698
PMID: 34765721
ISSN: 2352-9067
CID: 5050742

Lesion Sequence and Catheter Spatial Stability Affect Lesion Quality Markers in Atrial Fibrillation Ablation

Jankelson, Lior; Dai, Matthew; Aizer, Anthony; Bernstein, Scott; Park, David S; Holmes, Douglas; Chinitz, Larry A; Barbhaiya, Chirag
OBJECTIVES/OBJECTIVE:This study sought to analyze high-frequency catheter excursion in relation to lesion quality markers in 20 consecutive patients undergoing first-time radiofrequency (RF) ablation for paroxysmal atrial fibrillation (AF). BACKGROUND:Ablation therapy for AF requires the delivery of durable lesions. The extent to which lesion sequence, catheter spatial stability, and anatomic location influence lesion formation during RF ablation of AF is not well understood. METHODS:Three-dimensional spatial excursion of the ablation catheter sampled at 60 Hz during pre-specified pairs of RF lesions was extracted from the CARTO3 System (Biosense Webster Inc., Irvine, California) and analyzed by using custom-developed MATLAB software (MathWorks, Natick, Massachusetts) to define precise catheter spatial stability during RF ablation. Ablation parameters including bipolar electrogram amplitude reduction, impedance decline and transmurality-associated unipolar electrogram (TUE) as evidence of lesion transmurality during lesion placement were recorded and analyzed. RESULTS:We collected 437,760 position data points during lesion placement. Ablation catheter spatial stability and lesion formation parameters varied considerably by anatomic location. Lesions placed immediately had similar bipolar electrogram amplitude reduction, smaller impedance decline, but higher likelihood of achieving TUE compared to delayed lesions. Greater catheter spatial stability correlated with lesser impedance decline. CONCLUSIONS:Lesion sequence, ablation catheter spatial stability, and anatomic location are important modifiers of RF lesion formation. Lesions placed immediately are more likely to exhibit TUE. Greater ablation catheter stability is associated with lesser impedance decline but greater likelihood of TUE.
PMID: 33516716
ISSN: 2405-5018
CID: 4775692

QT interval dynamics and triggers for QT prolongation immediately following cardiac arrest

Cohen, Roi Bar; Dai, Matthew; Aizer, Anthony; Barbhaiya, Chirag; Peterson, Connor; Bernstein, Scott; Park, David; Spinelli, Michael; Chinitz, Larry; Jankelson, Lior
BACKGROUND:The prolongation in QT interval typically observed following cardiac arrest is considered to be multifactorial and induced by external triggers such as hypothermia therapy and exposure to antiarrhythmic medications. OBJECTIVE:To evaluate the corrected QT interval (QTc) dynamics in the first 10 days following cardiac arrest with respect to the etiology of arrest, hypothermia and QT prolonging medications. METHODS:We enrolled 104 adult survivors of cardiac arrest, where daily ECG was available for at least 3 days. We followed their QT and QRS intervals for the first 10 days of hospitalization. We used both Bazett and Fridericia formulas to correct for heart rate. For patients with QRS < 120 we analyzed the QTc interval (n = 90) and for patients with QRS > 120 ms we analyzed the JTc (n = 104) vs. including only the narrow QRS samples (n = 89). We stratified patients by 3 groups: (1) presence of ischemic heart disease (IHD) (2) treatment with hypothermia protocol, and (3) treatment with QTc prolonging medications. Additionally, genetic information obtained during hospitalization was analyzed. RESULTS:QTc and JTc intervals were significantly prolonged in the first 6 days. Maximal QTc/JTc prolongation was observed in day 2 (QTcB = 497 ± 55). There were no differences in daily QTc/JTc and QRS intervals in the first 2 days post arrest between patients with or without hypothermia induction but such difference. All subgroups demonstrated significantly prolonged QTc/JTc interval regardless of the presence of IHD, hypothermia protocol or QTc prolonging medication exposure. Our results were consistent for both Bazetts' and Frediricia correction and for any QRS duration. Prolongation of the JTcB beyond 382 ms after day 3 predicted sustained QTc/JTc prolongation beyond day 6 with an ROC of 0.78. CONCLUSIONS:QTc/JTc interval is significantly and independently prolonged post SCA, regardless of known QT prolonging triggers. Normalization of the QTc post cardiac arrest should be expected only after day 6 of hospitalization. Assessment of the QTc for adjudication of the etiology of arrest or for monitoring the effect of QT prolonging medications may be unreliable.
PMID: 33652119
ISSN: 1873-1570
CID: 4801392

Electrocardiographic Risk Stratification in COVID-19 Patients

Chorin, Ehud; Dai, Matthew; Kogan, Edward; Wadhwani, Lalit; Shulman, Eric; Nadeau-Routhier, Charles; Knotts, Robert; Bar-Cohen, Roi; Barbhaiya, Chirag; Aizer, Anthony; Holmes, Douglas; Bernstein, Scott; Spinelli, Michael; Park, David; Chinitz, Larry; Jankelson, Lior
Background: The COVID-19 pandemic has resulted in worldwide morbidity at unprecedented scale. Troponin elevation is a frequent laboratory finding in hospitalized patients with the disease, and may reflect direct vascular injury or non-specific supply-demand imbalance. In this work, we assessed the correlation between different ranges of Troponin elevation, Electrocardiographic (ECG) abnormalities, and mortality. Methods: We retrospectively studied 204 consecutive patients hospitalized at NYU Langone Health with COVID-19. Serial ECG tracings were evaluated in conjunction with laboratory data including Troponin. Mortality was analyzed in respect to the degree of Troponin elevation and the presence of ECG changes including ST elevation, ST depression or T wave inversion. Results: Mortality increased in parallel with increase in Troponin elevation groups and reached 60% when Troponin was >1 ng/ml. In patients with mild Troponin rise (0.05-1.00 ng/ml) the presence of ECG abnormality and particularly T wave inversions resulted in significantly greater mortality. Conclusion: ECG repolarization abnormalities may represent a marker of clinical severity in patients with mild elevation in Troponin values. This finding can be used to enhance risk stratification in patients hospitalized with COVID-19.
PMCID:7884321
PMID: 33604358
ISSN: 2297-055x
CID: 4787212

Multiple Procedure Outcomes for Non-Paroxysmal Atrial Fibrillation: Left Atrial Posterior Wall Isolation versus Stepwise Ablation

Barbhaiya, Chirag R; Knotts, Robert J; Beccarino, Nicholas; Vargas-Pelaez, Alvaro F; Jankelson, Lior; Bernstein, Scott; Park, David; Holmes, Douglas; Aizer, Anthony; Chinitz, Larry A
OBJECTIVE:To compare multiple-procedure catheter ablation outcomes of a stepwise approach versus left atrial posterior wall isolation (LA PWI) in patients undergoing non-paroxysmal atrial fibrillation (NPAF) ablation. BACKGROUND:Unfavorable outcomes for stepwise ablation of NPAF in large clinical trials may be attributable to pro-arrhythmic effects of incomplete ablation lines. It is unknown if a more extensive initial ablation strategy results in improved outcomes following multiple ablation procedures. METHODS:222 consecutive patients with NPAF underwent first-time ablation using a contact-force sensing ablation catheter utilizing either a stepwise (Group 1, n=111) or LA PWI (Group 2, n=111) approach. The duration of follow-up was 36 months. The primary endpoint was freedom from atrial arrhythmia >30s. Secondary endpoints were freedom from persistent arrhythmia, repeat ablation, and recurrent arrhythmia after repeat ablation. RESULTS:There was similar freedom from atrial arrhythmias after index ablation for both stepwise and LA PWI groups at 36 months (60% vs. 69%, p=0.1). The stepwise group was more likely to present with persistent recurrent arrhythmia (29% vs 14%, p=0.005) and more likely to undergo second catheter ablation (32% vs. 12%, p<0.001) compared to LA PWI patients. Recurrent arrhythmia after repeat ablation was more likely in the stepwise group compared to the LA PWI group (15% vs 4%, p=0.003). CONCLUSIONS:Compared to a stepwise approach, LA PWI for patients with NPAF resulted in a similar incidence of any atrial arrhythmia, lower incidence of persistent arrhythmia, and fewer repeat ablations. Results for repeat ablation were not improved with a more extensive initial approach. This article is protected by copyright. All rights reserved.
PMID: 33022816
ISSN: 1540-8167
CID: 4626822

Response to: Do not yet abandon cephalic vein access for multiple leads in ICD implantation [Letter]

Barbhaiya, Chirag R; Niazi, Osama; Jankelson, Lior; Bernstein, Scott; Park, David; Holmes, Douglas; Aizer, Anthony; Chinitz, Larry A
PMID: 32789905
ISSN: 1540-8167
CID: 4556572

Reply: Electrical Weapons and Electrophysiology

Barbhaiya, Chirag R; Moskowitz, Craig; Duraiswami, Harish; Jankelson, Lior; Knotts, Robert J; Bernstein, Scott; Park, David; Holmes, Douglas; Aizer, Anthony; Chinitz, Larry A
PMCID:8299239
PMID: 34317106
ISSN: 2666-0849
CID: 4949432

Ablation in Atrial Fibrillation with Ventricular Pacing Results in Similar Spatial Catheter Stability as Compared to Ablation in Sinus Rhythm with Atrial Pacing

Dai, Matthew; Barbhaiya, Chirag; Aizer, Anthony; Hyde, Jonathan; Kogan, Edward; Holmes, Douglas; Bernstein, Scott; Spinelli, Michael; S Park, David; A Chinitz, Larry; Jankelson, Lior
Background/UNASSIGNED:Improved catheter stability is associated with decreased arrhythmia recurrence after atrial fibrillation (AF) ablation. Recently, atrial voltage mapping in AF was demonstrated to correlate better with scar as compared to mapping in sinus rhythm (SR). However, it is unknown whether ablation of persistent AF in sinus rhythm with atrial pacing or in atrial fibrillation with ventricular pacing results in differences in catheter stability or arrhythmia recurrence. Methods/UNASSIGNED:We analyzed 53 consecutive patients undergoing first-time persistent AF ablation with pulmonary vein and posterior wall isolation: 27 were cardioverted, mapped, and ablated in sinus rhythm with atrial pacing, and 26 were mapped and ablated in AF with ventricular pacing. Ablation data was extracted from the mapping system and analyzed using custom MATLAB software to determine high-frequency (60Hz) catheter excursion as a novel metric for catheter spatial stability. Results/UNASSIGNED:There was no difference in catheter stability as assessed by maximal catheter excursion, mean catheter excursion, or contact force variability between the atrial-paced and ventricular-paced patients. Ventricular-paced patients had significantly greater mean contact force as compared to atrial-paced patients. Contact-force variability demonstrated poor correlation with catheter excursion. One year arrhythmia-free survival was similar between the atrial paced and ventricular paced patients. Conclusions/UNASSIGNED:For patients with persistent AF, ablation in AF with ventricular pacing results in similar catheter stability and arrhythmia recurrence as compared to cardioversion and ablation in sinus rhythm with atrial pacing. Given the improved fidelity of mapping in AF, mapping and ablating during AF with ventricular pacing may be preferred.
PMCID:8691334
PMID: 34950311
ISSN: 1941-6911
CID: 5093082

QT Interval Prolongation and Torsade De Pointes in Patients with COVID-19 treated with Hydroxychloroquine/Azithromycin

Chorin, Ehud; Wadhwani, Lalit; Magnani, Silvia; Dai, Matthew; Shulman, Eric; Nadeau-Routhier, Charles; Knotts, Robert; Bar-Cohen, Roi; Kogan, Edward; Barbhaiya, Chirag; Aizer, Anthony; Holmes, Douglas; Bernstein, Scott; Spinelli, Michael; Park, David S; Stefano, Carugo; Chinitz, Larry A; Jankelson, Lior
BACKGROUND:There is no known effective therapy for patients with COVID-19. Initial reports suggesting the potential benefit of Hydroxychloroquine/Azithromycin (HY/AZ) have resulted in massive adoption of this combination worldwide. However, while the true efficacy of this regimen is unknown, initial reports have raised concerns regarding the potential risk of QT prolongation and induction of torsade de pointes (TdP). OBJECTIVE:to assess the change in QTc interval and arrhythmic events in patients with COVID-19 treated with HY/AZ METHODS: This is a retrospective study of 251 patients from two centers, diagnosed with COVID-19 and treated with HY/AZ. We reviewed ECG tracings from baseline and until 3 days after completion of therapy to determine the progression of QTc and incidence of arrhythmia and mortality. RESULTS:QTc prolonged in parallel with increasing drug exposure and incompletely shortened after its completion. Extreme new QTc prolongation to > 500 ms, a known marker of high risk for TdP had developed in 23% of patients. One patient developed polymorphic ventricular tachycardia (VT) suspected as TdP, requiring emergent cardioversion. Seven patients required premature termination of therapy. The baseline QTc of patients exhibiting extreme QTc prolongation was normal. CONCLUSION/CONCLUSIONS:The combination of HY/AZ significantly prolongs the QTc in patients with COVID-19. This prolongation may be responsible for life threating arrhythmia in the form of TdP. This risk mandates careful consideration of HY/AZ therapy in lights of its unproven efficacy. Strict QTc monitoring should be performed if the regimen is given.
PMCID:7214283
PMID: 32407884
ISSN: 1556-3871
CID: 4431542