Searched for: person:lw901
in-biosketch:yes
Fatigue reliability and failure modes of metal-ceramic, monolithic zirconia, and lithium disilicate implant-supported crowns cemented to titanium bases: A step-stress accelerated life testing study
Zampara, Eirini; Kontonasaki, Eleana; Bergamo, Edmara T P; Hirata, Ronaldo; Maluf, Caroline Vieira; Koltsakidis, Savvas; Tzetzis, Dimitrios; Vale, Marly; Bonfante, Estevam A; Jahangiri, Leila; Witek, Lukasz
STATEMENT OF PROBLEM/BACKGROUND:The fatigue behavior under clinically relevant loading conditions of implant-supported screw-retained crowns cemented to titanium bases fabricated from different restorative materials remains insufficiently understood. PURPOSE/OBJECTIVE:The purpose of this study was to evaluate the failure modes, fatigue reliability, and survival probabilities of metal-ceramic (MC), monolithic zirconia (3Y-TZP), and lithium disilicate (LD) single premolar implant-supported screw-retained crowns cemented to titanium bases using step-stress accelerated life testing (SSALT). MATERIAL AND METHODS/METHODS:Sixty crowns were bonded to titanium bases (UNP RH 4 mm, GH 2 mm; Adin Dental Implant Systems Ltd), connected to internal hexagon implants (4.2-mm platform diameter, 10-mm length; Touareg S, Adin Dental Implant Systems Ltd), embedded in acrylic resin blocks, and subjected to single-load-to-failure testing (n=6) to determine stress profiles for SSALT (n=54). Use-level probability Weibull curves were calculated to estimate reliability for a mission of 100 000 cycles at 200 and 300 N. Failed specimens underwent polarized light stereomicroscopy and scanning electron microscopy (SEM) for fractographic analysis. RESULTS:All specimens failed during SSALT loading profiles. Beta (β) values derived from use-level probability Weibull curves were greater than 1 for all groups, indicating fatigue-driven failure behavior. 3Y-TZP crowns demonstrated the highest fatigue reliability, with survival probabilities up to 98% at tested load levels (200 and 300 N). LD showed intermediate performance (93% at 200 N and 88% at 300 N), whereas MC crowns showed the lowest survival probabilities (86% at 200 N and 82% at 300 N). At 200 N, no statistically significant differences were observed among groups. At 300 N, 3Y-TZP crowns showed significantly higher survival probability than MC crowns (P=.038), while LD showed intermediate values and was not significantly different from either group. Fractographic analysis revealed material-specific fracture origins and crack propagation patterns. CONCLUSIONS:All crown types demonstrated high survival probabilities. 3Y-TZP crowns showed higher fatigue reliability than MC crowns, while LD crowns demonstrated intermediate performance.
PMID: 42888136
ISSN: 1097-6841
CID: 6074700
Injectable graphene oxide-PEG/collagen hydrogel enables controlled Atsttrin/TNFR2 signaling and 14-3-3ε-dependent bone regeneration under diabetic conditions
Moradi, Lida; Witek, Lukasz; Huang, Guiwu; Liu, Chuan-Ju
Atsttrin, a therapeutic derivative of progranulin, promotes tissue repair via TNFR2-mediated anti-inflammatory and regenerative signaling. Our group developed an injectable, thermoresponsive graphene oxide-polyethylene glycol/collagen type I hydrogel for sustained and localized delivery of Atsttrin and systematically evaluated its therapeutic efficacy in vitro and in vivo models. The hydrogel demonstrated favorable rheological properties, controlled degradation, high porosity, and sustained Atsttrin release over seven weeks. In vitro cytocompatibility assays confirmed its non-cytotoxic nature, which was further corroborated by long-term in vivo safety assessments indicating the absence of organ toxicity up to three months post-administration. Functional studies using wild-type and 14-3-3ε knockout bone marrow-derived mesenchymal stem cells revealed that Atsttrin significantly enhanced chondrogenic and osteogenic differentiation in WT cells, effects that were markedly reduced in KO cells. Hydrogel-encapsulated Atsttrin elicited more robust regenerative responses compared to administration of free Atsttrin, underscoring the critical role of controlled release in enhancing therapeutic efficacy. In vivo, Atsttrin-loaded hydrogels significantly accelerated fracture healing in both WT and diabetic mice, with diminished efficacy in 14-3-3ε-deficient models. Collectively, these results support an important role for 14-3-3ε in mediating the regenerative effects of Atsttrin and demonstrate the potential of the GO-PEG/Collagen I hydrogel as a localized delivery platform for bone repair.
PMID: 42906433
ISSN: 2772-9508
CID: 6074895
3D-Printed Poly(Lactic-co-Glycolic Acid) Binder-Based Self-Hardening Calcium Phosphate Bone Scaffolds
Sturm, Savanah R; Mirsky, Nicholas A; Sandino, Adriana I; Castellon, Maria; Desai, Anshumi J; Guanche, Isabella D; Johansson, Linh; Raymond, Yago; Nayak, Vasudev Vivekanand; Witek, Lukasz; Coelho, Paulo G
Three-dimensionally (3D)-printed alpha-tricalcium phosphate (α-TCP) scaffolds, fabricated through a low-temperature hydrothermal dissolution-precipitation process, replicate the structural and compositional features of native bone. Reinforcing hydrothermally processed α-TCP with poly(lactic-co-glycolic acid) (PLGA) as a binder has previously been shown to confer distinct mechanical advantages, supporting its potential as a viable material for bone regenerative scaffolds. Although the hydrothermal processing of α-TCP scaffolds and PLGA-based mechanical reinforcement have each been characterized individually in earlier studies, this work represents the first pre-clinical in vivo assessment of osseoconduction and biocompatibility of 3D-printed, PLGA-reinforced, self-hardening calcium phosphate scaffolds in a large translational animal model. A ceramic ink suitable for extrusion was prepared by combining a 30 wt/vol% poloxamer 407 solution with α-TCP powder at a 0.45 wt/wt ratio (CTRL). A second extrudable ink, consisting of an α-TCP ceramic suspension incorporating a 35 wt/wt% PLGA binder, was formulated at a 0.5 wt/wt ratio (EXP). Cylindrical scaffolds (6 mm × 6 mm) were fabricated at room temperature using a custom-built Direct Ink Write 3D printer, then hydrothermally treated via submersion in water and thermal consolidation at 121 °C. Osteotomies were created in the ilium of adult sheep, with two cylindrical defects (7 mm × 6 mm) per animal, each receiving either a CTRL or EXP scaffold. Animals were euthanized at 3 and 12 weeks post-surgery (n = 6 animals per time point), and samples were collected en bloc for analysis. For both scaffold formulations, hard tissue formed by 12 weeks displayed high cellularity and active vascularization, consistent with early woven bone formation. Quantitative analysis revealed no significant between-group differences in bone formation at either time point (p > 0.05). These findings indicate that 3D-printed, PLGA-reinforced, self-hardening α-TCP scaffolds are osseoconductive and biocompatible, supporting their potential use in orthopedic and craniomaxillofacial bone defect repair.
PMCID:13603544
PMID: 42791921
ISSN: 2306-5354
CID: 6073591
Postmortem Analysis of Osseointegration in Cementless Acetabular Components After Total Hip Arthroplasty: A Multimodal Study
Saba, Braden V; Schaffler, Benjamin; Martins de Souza, Bruno; Schaffer, Olivia; Fallah, Cameron; Alhaddad, Noor; Montague, Michael; Fritz, Jan; Hopper, Robert; Engh, Charles A; Witek, Lukasz; Schwarzkopf, Ran
INTRODUCTION/BACKGROUND:Press-fit acetabular components achieve long-term fixation through osseointegration, yet the extent of bone ingrowth necessary for durable stability in well-functioning implants remains unclear. Postmortem retrievals provide a unique opportunity to directly assess the bone-cup interface in clinically successful total hip arthroplasties (THAs). This study evaluated osseointegration and biomechanical fixation strength in deceased-donor acetabular components to better define the characteristics of stable long-term fixation. METHODS:Cadaver pelvis specimens containing uncemented THAs from a single institution were evaluated. There were 29 acetabular components that underwent axial pull-out testing using a universal testing machine. A total of seven of these were additionally processed for histologic evaluation, including dehydration, acrylic embedding, thin-sectioning, staining, and digital imaging. Osseointegration was quantified by bone-area fraction occupancy (%BAFO), representing the proportion of bone occupying the porous thread spaces of the cup. RESULTS:All 29 specimens failed through fracture of the ilium rather than at the bone-cup interface, indicating that the mechanical integrity of the osseointegrated construct exceeded that of the surrounding bone under axial tension. Among the seven histologically analyzed components, %BAFO ranged from 4.2 to 27.0% (mean 15.1%), despite all implants being clinically stable at the time of death. There were no significant linear correlations observed between %BAFO and time implanted, fracture load, or body mass index. A significant quadratic relationship between %BAFO and age was identified, peaking near 81 years. CONCLUSIONS:Cementless acetabular components exhibited strong fixation despite modest osseointegration, with failure occurring through host bone on axial testing. Durable biological fixation appears achievable with limited, but mechanically favorable bone ingrowth.
PMID: 42069020
ISSN: 1532-8406
CID: 6029862
Extended hydrothermal aging and glass infiltration on minimally processed recycled 3Y-TZP: microstructural and optical properties
Strazzi-Sahyon, Henrico B; Silva, Bruna M; Campos, Tiago M B; Dos Santos, Claudinei; Piza, Mariana M T; Bergamo, Edmara T P; Tebcherani, Sergio M; Witek, Lukasz; Coelho, Paulo G; Yamaguchi, Satoshi; Bonfante, Estevam A
This study evaluated the effects of glass infiltration and hydrothermal aging on the microstructural and optical properties of minimally processed recycled 3Y-TZP. Unprocessed 3Y-TZP remnants were milled into powder, compacted into discs, and sintered. Specimens were divided into six groups according to glass infiltration and hydrothermal aging (immediate, 50 h, and 100 h at 134 °C/2.2 bar). Particle size was measured by laser diffraction. Density and optical properties (contrast ratio and translucency) were longitudinally evaluated on the same specimens using Archimedes' principle and reflectance measurements (n = 10), whereas crystalline phases (Raman spectroscopy, n = 3), surface and cross-sectional morphology (n = 3), and elemental composition (n = 3) were analyzed on independent specimens allocated to each experimental condition. Color stability and translucency variation were compared with perceptibility (PT = 0.81; TPT = 0.62) and acceptability (AT = 1.77; TAT = 2.62) thresholds (n = 10). Density data were analyzed using one-way repeated-measures ANOVA, while optical properties were analyzed using two-way repeated-measures ANOVA, followed by Tukey's post hoc test. Mean particle size of recycled powder was 1.61 μm. Relative densities for immediate, 50 h, and 100 h groups were 99.68%, 99.24%, and 99.04%. Raman spectra revealed predominance of tetragonal-cubic phases in immediate non-infiltrated group, while monoclinic phase prevailed in others. SEM showed homogeneous surfaces. EDS confirmed zirconium, yttrium, and hafnium in non-infiltrated groups, and silicon, aluminum, sodium, potassium, and calcium in infiltrated. Non-infiltrated groups showed lower contrast ratio and greater translucency than infiltrated, independent of aging. Aging minimally affected optical properties, except infiltrated specimens, where translucency was higher immediately than after 50-100 h. All groups exhibited color and translucency variation below perceptibility and acceptability thresholds. Prolonged hydrothermal degradation influenced the microstructural and optical features of recycled 3Y-TZP, while glass infiltration further modified these characteristics, reducing translucency while increasing opacity and color stability.
PMID: 42624969
ISSN: 1618-1255
CID: 6071568
Dipyridamole-Coated 3D-Printed β-Tricalcium Phosphate Scaffolds: Spectrophotometric Characterization, Drug Release Kinetics, and In Vitro Evaluation to Guide Critical-Sized Bone Defect Repair Studies
Rasane, Purva; Nayak, Vasudev Vivekanand; Weerasinghe Arachchige, Lahiru Chamara; Rice, Eleni; Ashin, Zeinab Fotouhi; Venkatesan, Bharath; Varanasi, Venu; Ono, Noriaki; Young, Simon; Witek, Lukasz
Critical-sized bone defects remain a significant clinical challenge, and dipyridamole (DIPY)-coated 3D-tricalcium phosphate (β-TCP) scaffolds have shown promising osteogenic efficacy in preclinical models. However, the literature on the systematic physicochemical characterization of this scaffold system, including optimization of DIPY loading parameters, release kinetics, and surface properties, is lacking. This study addresses these gaps by characterizing DIPY-loaded 3D-printed β-TCP scaffolds across solid and porous architectures, three coating concentrations (10, 100, and 1000 µM), and three coating volumes (250, 500, and 1000 µL). Under static PBS conditions, drug release over 21 days was quantifiable only at 1000 µM, and release-kinetics modeling (zero-order, Higuchi, and Korsmeyer-Peppas) was therefore restricted to this highest concentration. At 1000 µM, both scaffold types showed biphasic release profiles, with standard empirical models reasonably approximating the overall kinetics, while not fully capturing the biphasic behavior over the entire duration. Porous scaffolds showed significant volume-dependent release (p = 0.002, η
PMCID:13514228
PMID: 42646199
ISSN: 2079-4983
CID: 6071738
Light-based vat-polymerization of electroconductive gelatin methacryloyl composite hydrogels for soft tissue interfacing
Elkhoury, Kamil; Zhou, Jiarui; Usmani, Sadaf; Nagarajan, Vinod; Menon, Abhay; Boitet, Maylis; Hacquebord, Jacques H; Witek, Lukasz; Ramadi, Khalil; Vijayavenkataraman, Sanjairaj
Conductive hydrogels have emerged as promising materials for soft tissue interfacing by combining tissue-like mechanical compliance with electrical conductivity, thereby enabling improved electrical communication with electroactive biological tissues. This work presents an electroconductive composite hydrogel fabricated via light-based vat-polymerization by integrating a choline-based bio-ionic liquid (IL) with gelatin methacryloyl (GelMA). The resulting hydrogels demonstrate tunable conductivity, structural integrity, and high print fidelity when fabricated using digital light processing (DLP) light-based 3D printing. Electrical conductivity was optimized at 20% v/v IL concentration, with the hydrogels demonstrating stable performance for over 28 days. A food-grade photoabsorber was integrated into the formulation to improve DLP resolution and was effectively removed after printing process. The hydrogels supported the human mesenchymal stem cells' viability and proliferation, confirming their cytocompatibility. They also promoted enhanced maturation of primary neurons, demonstrating a supportive microenvironment for neural cells. In vivo implantation of indocyanine green-loaded hydrogels exhibited sustained stability and robust retention of signal over a period of 4 weeks, with histological analysis indicating seamless integration with surrounding tissues. Impedance spectroscopy at both gut and spinal cord interfaces illustrated that GelMA/IL composites achieved the lowest impedance across a range of frequencies, outperforming both GelMA-only and tissue-only conditions. Collectively, these findings position light-based vat-polymerized electroconductive composites as a promising platform for the development of anatomically conformal materials tailored for soft tissue interfacing.
PMID: 42492710
ISSN: 1879-0003
CID: 6071584
Mechanical Constriction of the Maxilla Alters Nasal Architecture
Teixeira, Cristina C; Uribe-Querol, Eileen; Garzón, Daniel L; Sangsuwon, Chinapa; Nervina, Jeanne; Abdullah, Fanar; Alikhani, Mona; Galindo-Solano, Nuria; Serrano-Bello, Janeth; Pérez-Sánchez, Lucia; Witek, Lukasz; Villagómez-Olea, Guillermo; Marichi-Rodríguez, Francisco J; Alikhani, Mani
PMCID:13410686
PMID: 42513341
ISSN: 2077-0383
CID: 6070508
Comparative Histological Evaluation of Collagen Matrix Architectures for Soft Tissue Augmentation in the Oral Cavity: A Preclinical Canine Model
Shah, Hana; Iglesias, Nicholas J; Munkwitz, Sara E; Slavin, Blaire V; Stauber, Zachary M; Ehlen, Quinn T; Nayak, Vasudev Vivekanand; Thaller, Seth R; Witek, Lukasz; Coelho, Paulo G
Intraoral soft-tissue defects are traditionally managed with autogenous connective tissue grafts, though donor site morbidity has driven interest in xenogeneic collagen matrices as alternatives. However, the impact of matrix architecture on soft-tissue integration remains poorly understood. This study compared soft-tissue responses to a sheet-form collagen matrix (ShCM) and a spongy collagen matrix (SpCM) placed beneath full-thickness flaps in a beagle mandibular defect model. Standardized bilateral defects were created in 23 skeletally mature female beagles. Defects were then assigned to serve as the negative control (sham) or were treated with porcine collagen matrix in (i) sheet form (ShCM) (Regenity Biosciences, Oakland, NJ, USA), or (ii) porous/spongy form (SpCM) (Fibro-Gide®, Geistlich Pharma North America, West Windsor Township, NJ, USA). The mandibular sites that received no surgical intervention served as positive controls. Experimental conditions were randomized and interpolated within each animal to minimize anatomical site bias and evaluated histologically at 4- (n = 7), 8- (n = 7), and 12-weeks (n = 9) postoperatively. Histologic sections were evaluated for matrix presence, inflammation, subepithelial healing, and matrix thickness. At 4 weeks, both matrices were present, though SpCM showed significantly higher inflammation scores (p = 0.013). By 8 weeks, ShCM demonstrated greater resorption (p = 0.003) alongside an organized collagen layer with fibroblasts and new microvessels, while SpCM remained thick and porous, with a persistent fibrous capsule and elevated inflammation versus both ShCM (p = 0.002) and sham (p = 0.009). At 12 weeks, inflammation declined and subepithelial healing improved similarly across matrix groups. These findings suggest matrix architecture influences soft-tissue healing outcomes in the oral cavity. Sheet-form matrices may be preferable where biocompatibility and predictable integration are priorities, while spongy matrices may better support long-term space maintenance and tissue ingrowth. However, clinical studies are needed to confirm these translational implications.
PMCID:13295686
PMID: 42351907
ISSN: 2306-5354
CID: 6056252
Rasping in Rhinoplasty: Bone Healing Outcomes With Manual Versus Piezoelectric-Assisted Techniques
Shah, Hana; Munkwitz, Sara E; Iglesias, Nicholas J; Wu, Shangtao; Brochu, Baylee M; Nayak, Vasudev Vivekanand; Jabori, Sinan; Thaller, Seth R; Witek, Lukasz; Coelho, Paulo G
There has been an increasing trend in using piezoelectric devices in craniofacial surgery to selectively cut bone and reduce collateral soft tissue trauma. Although the benefits of piezosurgery have been well demonstrated for osteotomies, its impact on bone healing during rasping remains understudied. This study evaluated bone regeneration following medial maxillary rasping performed with a manual rasp (MR) compared with piezotome-assisted rasping (PR) in a skeletally mature sheep model. Bilateral defects (rasps: ∼2 cm x ∼2 cm) were created along the coronal plane on the anterodorsal aspect of the nasal bone, with PR used on the anatomic right side and MR on the anatomic left side. Nondecalcified histologic processing and analysis was performed on the nasomaxillary bone at 3 and 12 weeks postoperatively (n=6 sheep/timepoint). At 3 weeks, MR-treated defects showed smoother, intact bone defect margins with minimal bone deposition. PR-treated defects displayed more irregular margins with scattered bone fragments, consistent with ultrasonic microfracturing. By 12 weeks, both techniques demonstrated comparable healing patterns with a regenerating nasal bone contour, maturation of bone architecture, visible osteocytes, and no evidence of bone fragments or inflammatory infiltrates. Semiquantitative scoring of osteogenesis revealed statistically homogenous findings between MR and PR usage (p=0.63 at 3 weeks; p=1.00 at 12 weeks). Within the limits of this model, piezotome-assisted rasping altered early bone surface topography but did not impair long-term bone regeneration compared with manual rasping. This provides preclinical support for piezotome use as an alternative bone-modifying technique in rhinoplasty.
PMID: 41557018
ISSN: 1536-3732
CID: 5988262