Searched for: person:phillm07
in-biosketch:true
Assessing current capabilities and barriers to performing routine laboratory tests on patients with suspected high consequence infectious disease at frontline acute care hospitals
DiLorenzo, Madeline A; Lo Piccolo, Anthony Joseph; Bosk, Jared; Shapiro-Luft, Dina; Biddinger, Paul; Bhadelia, Nahid; Jausurawong, Tani; Sulmonte, Christopher; Mazo, Dana; Phillips, Michael; Jacobson, Jessica L; Mukherjee, Vikramjit; Chan, Justin
INTRODUCTION/BACKGROUND:Patients with a suspected high-consequence infectious disease (HCID), such as Ebola virus disease, may require routine laboratory testing to guide management. We assessed the capabilities of frontline hospitals and the barriers they face performing laboratory testing for patients with a suspected HCID. METHODS:A one-time confidential REDCap survey querying capabilities to safely perform laboratory tests that the Centers for Disease Control and Prevention considers critical for patients with a suspected HCID was sent to 95 institutions in Baltimore, MD, Boston, MA, New York City, NY, and Washington, DC, from January to May 2025. RESULTS:Fifty (53%) institutions responded, mostly teaching hospitals (96%), with 24% reporting prior experience evaluating a patient with suspected Ebola virus disease. While many hospitals could perform on-site blood gas (70%), hemoglobin/hematocrit (68%), and lactate (68%) tests on a suspected HCID patient, fewer could safely perform a chemistry panel (64%), a urinalysis (60%), a complete blood count with differential (56%), and a malaria rapid diagnostic test (RDT) (48%) on a suspected HCID patient. The five tests respondents most often considered extremely or very important were hemoglobin/hematocrit (91%), chemistry panel (90%), CBC with differential and platelet count (89%), malaria RDT (88%), and blood gas (88%). Reported barriers to performing routine laboratory testing included issues related to patient and staff safety, infection control, lack of appropriate space, and funding. CONCLUSIONS:Our survey identified several barriers to implementing safe laboratory testing. The inability to conduct these laboratory tests may result in delays in care when an HCID is suspected.
PMID: 42204991
ISSN: 1559-6834
CID: 6070378
A Multidisciplinary Triad Model for Modern Infection Prevention and Control Departments: Moving Beyond Manual Surveillance to Data Driven-Action
Thompson, Corinne; Guyton, Mary Elizabeth; Hochman, Sarah; Modi, Hemangi; Cho, Ilseung; Levine, Samuel; Albert, Debra; Dean, Ranekka; Phillips, Michael
PMID: 42070736
ISSN: 1527-3296
CID: 6030662
The authors' reply to Jensen et al's Letter to the Editor [Letter]
Kaul, Christina M; Haller, Matthew; Yang, Jenny; Solomon, Sadie; Khan, Maria R; Pitts, Robert A; Phillips, Michael S
PMID: 38623842
ISSN: 1559-6834
CID: 5655812
Factors associated with loss to follow-up in outpatient parenteral antimicrobial therapy: A retrospective cohort study
Kaul, Christina M; Haller, Matthew; Yang, Jenny; Solomon, Sadie; Khan, Maria R; Pitts, Robert A; Phillips, Michael S
We assessed factors associated with increased risk to loss of follow-up with infectious diseases staff in OPAT patients. Discharge to subacute healthcare facilities is strongly associated with loss to follow-up. We did not identify sociodemographic disparities. Poor communication between OPAT providers and subacute healthcare facilities remains a serious issue.
PMCID:10933499
PMID: 37782035
ISSN: 1559-6834
CID: 5650932
The Effectiveness of Ultraviolet Smart D60 in Reducing Contamination of Flexible Fiberoptic Laryngoscopes
Ezeh, Uche C; Achlatis, Efstratios; Crosby, Tyler; Kwak, Paul E; Phillips, Michael S; Amin, Milan R
OBJECTIVE:To compare the effectiveness of disinfection protocols utilizing a ultraviolet (UV) Smart D60 light system with Impelux™ technology with a standard Cidex ortho-phthalaldehyde (OPA) disinfection protocol for cleaning flexible fiberoptic laryngoscopes (FFLs). METHODS:Two hundred FFLs were tested for bacterial contamination after routine use, and another 200 FFLs were tested after disinfection with one of four methods: enzymatic detergent plus Cidex OPA (standard), enzymatic detergent plus UV Smart D60, microfiber cloth plus UV Smart D60, and nonsterile wipe plus UV Smart D60. Pre- and post-disinfection microbial burden levels and positive culture rates were compared using Kruskal-Wallis ANOVA and Fisher's two-sided exact, respectively. RESULTS:After routine use, approximately 56% (112/200) of FFLs were contaminated, with an average contamination level of 9,973.7 ± 70,136.3 CFU/mL. The standard reprocessing method showed no positive cultures. The enzymatic plus UV, microfiber plus UV, and nonsterile wipe plus UV methods yielded contamination rates of 4% (2/50), 6% (3/50), and 12% (6/50), respectively, with no significant differences among the treatment groups (p > 0.05). The pre-disinfection microbial burden levels decreased significantly after each disinfection technique (p < 0.001). The average microbial burden recovered after enzymatic plus UV, microfiber plus UV, and nonsterile wipe plus UV were 0.40 CFU/mL ± 2, 0.60 CFU/mL ± 2.4, and 12.2 CFU/mL ± 69.5, respectively, with no significant difference among the treatment groups (p > 0.05). Micrococcus species (53.8%) were most frequently isolated, and no high-concern organisms were recovered. CONCLUSION:Disinfection protocols utilizing UV Smart D60 were as effective as the standard chemical disinfection protocol using Cidex OPA. LEVEL OF EVIDENCE:NA Laryngoscope, 133:3512-3519, 2023.
PMID: 37485725
ISSN: 1531-4995
CID: 5609162
The evaluation of electrolyzed water, sodium dichloroisocyanurate, and peracetic acid with hydrogen peroxide for the disinfection of patient room surfaces
Solomon, Sadie; Stachel, Anna; Kelly, Anne; Mraz, Joe; Aguilar, Peter; Gardner, Julia; Medefindt, Judith; Horrocks, Amy; Sterling, Stephanie; Aguero-Rosenfeld, Maria; Phillips, Michael
BACKGROUND:). METHODS:The study was conducted at 2 New York City hospitals (1,082 total beds) over an 18-month period. The 3 chemicals were applied by housekeeping personnel following the hospital protocol; the use of electrostatic sprayers was incorporated into EW and NaDCC. In randomly selected rooms, 5 surfaces were sampled for microbial colony counts after cleaning. Data analyses were performed using negative binomial logistic regression. RESULTS:(difference not significant). CONCLUSIONS:The use of NaDCC for surface disinfection resulted in the lowest bacterial colony counts on patient room high touch surfaces in our study.
PMID: 35777575
ISSN: 1527-3296
CID: 5281502
The impact of COVID-19 monoclonal antibodies on clinical outcomes: A retrospective cohort study
Nagler, Arielle R; Horwitz, Leora I; Jones, Simon; Petrilli, Christopher M; Iturrate, Eduardo; Lighter, Jennifer L; Phillips, Michael; Bosworth, Brian P; Polsky, Bruce; Volpicelli, Frank M; Dapkins, Isaac; Viswanathan, Anand; François, Fritz; Kalkut, Gary
DISCLAIMER/CONCLUSIONS:In an effort to expedite the publication of articles, AJHP is posting manuscripts online as soon as possible after acceptance. Accepted manuscripts have been peer-reviewed and copyedited, but are posted online before technical formatting and author proofing. These manuscripts are not the final version of record and will be replaced with the final article (formatted per AJHP style and proofed by the authors) at a later time. PURPOSE/OBJECTIVE:Despite progress in the treatment of coronavirus disease 2019 (COVID-19), including the development of monoclonal antibodies (mAbs), more clinical data to support the use of mAbs in outpatients with COVID-19 is needed. This study is designed to determine the impact of bamlanivimab, bamlanivimab/etesevimab, or casirivimab/imdevimab on clinical outcomes within 30 days of COVID-19 diagnosis. METHODS:A retrospective cohort study was conducted at a single academic medical center with 3 campuses in Manhattan, Brooklyn, and Long Island, NY. Patients 12 years of age or older who tested positive for COVID-19 or were treated with a COVID-19-specific therapy, including COVID-19 mAb therapies, at the study site between November 24, 2020, and May 15, 2021, were included. The primary outcomes included rates of emergency department (ED) visit, inpatient admission, intensive care unit (ICU) admission, or death within 30 days from the date of COVID-19 diagnosis. RESULTS:A total of 1,344 mAb-treated patients were propensity matched to 1,344 patients with COVID-19 patients who were not treated with mAb therapy. Within 30 days of diagnosis, among the patients who received mAb therapy, 101 (7.5%) presented to the ED and 79 (5.9%) were admitted. Among the patients who did not receive mAb therapy, 165 (12.3%) presented to the ED and 156 (11.6%) were admitted (relative risk [RR], 0.61 [95% CI, 0.50-0.75] and 0.51 [95% CI, 0.40-0.64], respectively). Four mAb patients (0.3%) and 2.64 control patients (0.2%) were admitted to the ICU (RR, 01.51; 95% CI, 0.45-5.09). Six mAb-treated patients (0.4%) and 3.37 controls (0.3%) died and/or were admitted to hospice (RR, 1.61; 95% CI, 0.54-4.83). mAb therapy in ambulatory patients with COVID-19 decreases the risk of ED presentation and hospital admission within 30 days of diagnosis.
PMCID:9619808
PMID: 36242772
ISSN: 1535-2900
CID: 5361302
Lack of Seasonal and Temporal Variability in Total Hip Arthroplasty Surgical Site Infections
Roof, Mackenzie A; Hutzler, Lorraine; Stachel, Anna; Friedlander, Scott; Phillips, Michael; Bosco, Joseph A
BACKGROUND:Surgical site infections (SSIs) are a signifi- cant cause of morbidity and mortality following total joint arthroplasty (TJA). While many risk factors are known, the seasonal and temporal associations of SSI are less under- stood. Understanding the associations can help reduce SSI rates. METHODS:We tracked rates of deep surgical site infec- tions (dSSIs) following total hip arthroplasty (THA) at a single large urban academic medical center from January 2009 through August 2018. Using a Poisson regression, we determined the monthly and seasonal variability of dSSIs. We also calculated the change in dSSI rate over the entire 9.67-year study period. RESULTS:In total, 15,703 THA cases between January 2009 and August 2018 were analyzed. There was no signifi- cant difference in the dSSI rate following THA in fall, winter, or spring as compared to summer. Similarly, there was no significant difference in dSSIs in July as compared to other months of the year. The average rate of dSSIs following THA was 1.04 (SD, 0.90) per 100 patients. The dSSI rate following THA decreased over the study period (r = 0.93, 95% CI: 0.84-1.03) but did not reach statistical significance. CONCLUSION/CONCLUSIONS:This study demonstrated a non-significant, albeit decreasing, rate of dSSIs following THA over the study period. Contrary to previous reports, there was no difference in the dSSI rate in the summer months as compared to other seasons. The month of the year also does not appear to be a significant risk factor for SSIs, calling into question previous reports arguing for the importance of the "July effect."
PMID: 36403949
ISSN: 2328-5273
CID: 5371862
Mitigation of nontuberculous mycobacteria in hospital water: challenges for infection prevention
Kaul, Christina M; Chan, Justin; Phillips, Michael S
PURPOSE OF REVIEW:The purpose of this review is to summarize recent literature on nontuberculous mycobacteria in water of healthcare systems. Despite improvement in identification techniques and emergence of infection prevention and control programs, nontuberculous mycobacteria remain present in hospital water systems, causing outbreaks and pseudo-outbreaks in healthcare settings. RECENT FINDINGS:Waterborne outbreaks and pseudo-outbreaks of nontuberculous mycobacteria continue to affect hospitals. Improvements in methods of identification and investigation, including MALDI-TOF and whole genome sequencing with evaluation of single nucleotide polymorphisms, have been used successfully in outbreak and pseudo-outbreak investigations. Recent studies have shown control of outbreaks in immunocompromised patients through the use of sterile water for consumption, as well as control of pseudo-outbreaks by using sterile water for procedures. Construction activities have been implicated in outbreaks and pseudo-outbreaks of nontuberculous mycobacteria. Water management programs are now required by the Joint Commission, which will likely improve water risk mitigation. SUMMARY:Improvement in detection and identification of nontuberculous mycobacteria has led to increasing recognition of waterborne outbreaks and pseudo-outbreaks. Water management programs are of vital importance in infection prevention.
PMID: 35849523
ISSN: 1473-6527
CID: 5278592
Assessment of risk factors associated with outpatient parenteral antimicrobial therapy (OPAT) complications: A retrospective cohort study
Kaul, Christina M; Haller, Matthew; Yang, Jenny; Solomon, Sadie; Wang, Yaojie; Wu, Rong; Meng, Yu; Pitts, Robert A; Phillips, Michael S
OBJECTIVE/UNASSIGNED:To characterize factors associated with increased risk of outpatient parenteral antimicrobial therapy (OPAT) complication. DESIGN/UNASSIGNED:Retrospective cohort study. SETTING/UNASSIGNED:Four hospitals within NYU Langone Health (NYULH). PATIENTS/UNASSIGNED:All patients aged ≥18 years with OPAT episodes who were admitted to an acute-care facility at NYULH between January 1, 2017, and December 31, 2020, who had an infectious diseases consultation during admission. RESULTS/UNASSIGNED:< .001). CONCLUSIONS/UNASSIGNED:Discharge to an SARC is strongly associated with increased risks of readmission for OPAT-related complications and CRBSI. Loss to follow-up with the infectious diseases service is strongly associated with increased risk of readmission and CRBSI. CRBSI prevention during SARC admission is a critically needed public health intervention. Further work must be done for patients undergoing OPAT to improve their follow-up retention with the infectious diseases service.
PMCID:9672913
PMID: 36406163
ISSN: 2732-494x
CID: 5383982