Searched for: person:vargah03
in-biosketch:true
Turning Up the Volume: Continuous PSMA-PET Metrics Add Value for Outcome Prediction in Patients with mCRPC [Editorial]
Vargas, Hebert Alberto; Woo, Sungmin
PMID: 41914862
ISSN: 1527-1315
CID: 6021382
Navigating discordant findings in multimodality imaging of prostate cancer in the MRI and PSMA-PET era
Woo, Sungmin; Masci, Benedetta; Becker, Anton S; Tong, Angela; Friedman, Kent P; de Galiza Barbosa, Felipe; Caruso, Damiano; Laghi, Andrea; Vargas, Hebert Alberto
Various imaging modalities play key roles throughout the different stages of prostate cancer. Each imaging modality has different strengths and weaknesses and various scoring systems or frameworks are used to interpret their findings. Discordances between imaging modalities or interpretation frameworks, and even with clinicopathological findings are not uncommon. Discordances often lead to challenges in the decision-making process, especially with dynamically changing indications for newer imaging modalities. While more research is needed on harmonizing interpretations across different modalities, multidisciplinary team discussion is key to optimizing management of patients with prostate cancer when such discordances are present. In this comprehensive review, we take a deep dive in to these various discordances seen in clinical practice and explore their clinical implications.
PMID: 41182592
ISSN: 1826-6983
CID: 5959432
VI-RADS quality score: development and proposal of a scoring system by the American College of Radiology VI-RADS Steering Committee
Woo, Sungmin; Luk, Lyndon; Muglia, Valdair F; Briganti, Alberto; Efstathiou, Jason; Galgano, Samuel J; Redd, Bernadette; de Rooij, Maarten; Takeuchi, Mitsuru; Witjes, J Alfred; Vargas, H Alberto; Panebianco, Valeria
High-quality bladder MRI is essential for reliable detection and characterization of bladder tumors. While the Vesical Imaging Reporting and Data System (VI-RADS) was developed to standardize acquisition, interpretation, and reporting of MRI for bladder cancer staging, no universal scoring system has been established for quality assessment. A systematic review showed that existing efforts for bladder MRI quality assessment have largely relied on study-specific, subjective Likert-type scales, with substantial variability, hindering reproducibility and comparability across studies and institutions. In this paper, we describe a novel bladder MRI scoring system that was developed by the multidisciplinary American College of Radiology VI-RADS Steering Committee, the VI-RADS Quality Score. It provides stratification of quality scores-inadequate, adequate, and optimal-based on signal-to-noise ratio, ability to clearly visualize relevant anatomic landmarks, and assessments of common imaging artifacts, which can guide clinical decision-making. It also emphasizes per-sequence scores in addition to an overall assessment to support targeted MRI protocol optimization. The VI-RADS Quality Score will need to be prospectively validated and will facilitate reproducibility across institutions, build trust in bladder MRI within multidisciplinary teams, and accelerate widespread adoption of bladder MRI for bladder cancer imaging. KEY POINTS: Question While high-quality bladder MRI is essential for evaluating bladder cancer, no universal scoring system is established for quality assessment. Findings A systematic review showed that studies on bladder MRI quality had significant variability. A structured scoring system was developed by the multidisciplinary VI-RADS steering committee. Clinical relevance High-quality bladder MRI is essential for reliable evaluation of bladder cancer. The VI-RADS Steering Committee developed a scoring system for bladder MRI quality assessment. This is expected to facilitate reproducibility and build trust in bladder MRI within multidisciplinary teams.
PMID: 40830701
ISSN: 1432-1084
CID: 5908962
Identification of Key Anatomical Structures on MRI During Prostate Stereotactic Body Radiotherapy For Dose Avoidance to Reduce Erectile Dysfunction Risk
Woo, Sungmin; Becker, Anton S; Tong, Angela; Vargas, Hebert Alberto; Schiff, Peter B; Byun, David J; Zelefsky, Michael J
Post-radiotherapy erectile dysfunction (ED) can significantly impact the quality of life of patients with prostate cancer (PCa). Critical anatomical structures, such as the neurovascular bundle (NVB), internal pudendal arteries (IPA), penile bulb, and corporal tissues track in close proximity to the prostate, making them susceptible to radiation-related damage. This study aimed to evaluate the anatomical patterns of these structures and their relationship with the prostate, and to provide comprehensive illustrative examples on MRI. Consecutive patients with PCa who underwent MRI-linear accelerator (LINAC)-based stereotactic body radiotherapy (SBRT) in January-December 2024 were included. NVB patterns were classified into 3 categories: (1) "classical" with discrete NVB elements, (2) "adherent", dispersed and adherent to prostatic capsule, and (3) "absent". The smallest distance between the IPA and the prostate capsule and membranous urethral length (MUL), serving as a surrogate for distance between corporal tissue and prostatic apex, were also measured. These MRI findings were compared between prostate volumes >40 and <40 ml and between MRI/pathological features of the dominant intraprostatic lesion. A total of 160 men (median age 70 years, interquartile range [IQR] 64-76) were included. The most common NVB pattern was "classic" (80.0-85.0%), followed by the "adherent" NVB pattern (13.8-18.1%). The median smallest distance between the IPA and prostate was 2.3 cm (IQR 1.8-2.8 cm), with 3.1-3.8% less than 1.0 cm. The median MUL was 1.5 cm (IQR, 1.2-1.8 cm), with 2.5% of patients less than 1.0 cm. No significant association was found between these MRI features and prostate volume or other variables (p = 0.09-0.99). In conclusion, most PCa patients demonstrated favorable anatomy for potential dose sparing of critical structures. Comprehensive MRI illustrations are provided to help radiation oncologists recognize the location, trajectory, and relationship of these structures, facilitating their contouring and ultimately aiding in achieving meaningful dose reductions to these erectile function structures.
PMID: 40602715
ISSN: 1879-8519
CID: 5888102
Implementing a Combined Lesion Measurement Tool in Hybrid PET Imaging to Reduce Clicks in Routine Clinical Practice: a Single-Center Brief Report
Becker, Anton S; Lindow, Norbert; Noorily, Ariella; Masci, Benedetta; Woo, Sungmin; Leithner, Doris; Friedman, Kent; Mayerhoefer, Marius E; Westerhoff, Malte; Vargas, H Alberto
OBJECTIVE:To develop a tool for the clinical hybrid imaging workflow which combines morphologic and functional measurements. And to quantify the number of clicks saved per positron emission tomography/computed tomography (PET/CT) interpretation. METHODS:A tool was developed where a volume of interest (VOI) is automatically created around line distance measurements. VOI statistics for both PET and CT component, and line distances are generated and displayed. Usage data for the first two months after introduction of the tool was analyzed. RESULTS:Eleven radiologists and nuclear medicine physicians used the tool in 364 PET/CTs. In 19% of examinations, the novel tool was the only tool that needed to be used. The novel combined tool was used 1001 times, whereas the traditional spherical VOI had been placed 1131 times. The usage ratio of new to traditional tool differed significantly between examinations with ≤ 6 annotations (ratio 1.0) versus > 6 annotations (ratio 0.63, p = 0.030). The average number of saved clicks per PET/CT was estimated at 16.5. CONCLUSION/CONCLUSIONS:A novel combined measurement tool for hybrid imaging was implemented and saved on average 16.5 clicks per examination. These improvements contribute to a smoother workflow and demonstrate the positive impact of thoughtful software design in medical practice.
PMID: 41381982
ISSN: 1573-689x
CID: 5977942
Navigating the Scoring Systems and Interpretation Frameworks of Prostate-specific Membrane Antigen PET
Woo, Sungmin; Masci, Benedetta; Rowe, Steven P; Caruso, Damiano; Laghi, Andrea; Burger, Irene A; Fanti, Stefano; Herrmann, Ken; Eiber, Matthias; Loeb, Stacy; Vargas, Hebert Alberto
Prostate-specific membrane antigen (PSMA) PET is a powerful tool for prostate cancer staging and restaging, providing higher sensitivity and specificity than conventional imaging. The recognition of interpretive pitfalls led to the development of various scoring systems and frameworks, which in turn created challenges for consistent interpretation. The Prostate Cancer Molecular Imaging Standardized Evaluation (PROMISE) version 2 classification integrates the five-point PRIMARY score for assessing local disease, the molecular imaging TNM stage for disease extent, and the PSMA expression score to assess eligibility for PSMA-targeted radioligand therapy. The PSMA Reporting and Data System (PSMA-RADS) classifies PSMA PET/CT findings on the basis of the likelihood of presence of prostate cancer. For assessing therapy response, PSMA PET Progression (PPP) criteria focus on new lesions and clinical or biochemical progression, whereas Response Evaluation Criteria in PSMA PET/CT (RECIP 1.0) assess new lesions and changes in total PSMA-positive total tumor volume. The European Association of Nuclear Medicine (EANM) E-PSMA guideline and EANM-Society of Nuclear Medicine and Molecular Imaging procedure guidelines provide standardized reporting recommendations, incorporating elements from existing systems such as PROMISE, PSMA-RADS, and PPP. Nevertheless, such systems can be essential for optimizing prostate cancer management and facilitating communication among imaging professionals, clinicians, and patients. This article outlines these systems and discusses potential strengths and weaknesses.
PMID: 41363980
ISSN: 1527-1315
CID: 5977222
Evaluating extraprostatic extension of prostate cancer: pragmatic integration of MRI and PSMA-PET/CT
Woo, Sungmin; Freedman, Daniel; Becker, Anton S; Leithner, Doris; Charbel, Charlotte; Mayerhoefer, Marius E; Friedman, Kent P; Tong, Angela; Wise, David R; Taneja, Samir S; Zelefsky, Michael J; Vargas, Hebert Alberto
PURPOSE/OBJECTIVE:To explore pragmatic approaches integrating MRI and PSMA-PET/CT for evaluating extraprostatic extension (EPE) of prostate cancer (PCa). METHODS:>12). Diagnostic performance was tested with receiver operating characteristic (ROC) curves and compared using DeLong and McNemar tests. RESULTS:>12 among which 87.5% (7/8) were corrected upgraded and had pathological EPE. CONCLUSION/CONCLUSIONS:Several pragmatic approaches were explored for integrating MRI and PSMA-PET/CT to assess EPE in PCa. Combining morphological information from MRI and PSMA expression on PET/CT demonstrated good diagnostic performance and may be a simple pragmatic integrated method that can be used.
PMID: 40252100
ISSN: 2366-0058
CID: 5829182
Correction to: Pictorial review of multiparametric MRI in bladder urothelial carcinoma with variant histology: pearls and pitfalls
Arita, Yuki; Woo, Sungmin; Ruby, Lisa; Kwee, Thomas C; Shigeta, Keisuke; Ueda, Ryo; Nalavenkata, Sunny; Edo, Hiromi; Miyai, Kosuke; Das, Jeeban; Causa Andrieu, Pamela I; Vargas, Hebert Alberto
PMID: 40312491
ISSN: 2366-0058
CID: 5834242
Evaluating Benefits of Peristomal Mesh Placement at the Time of Radical Cystectomy and Ileal Conduit Formation: A Phase 3, Randomized Controlled Trial
Donahue, Timothy F; Assel, Melissa; Cha, Eugene K; Goh, Alvin; Pietzak, Eugene; Dalbagni, Guido; Vickers, Andrew; Vargas, Hebert Alberto; Fleming, Stephen; Bochner, Bernard H
PURPOSE/UNASSIGNED:Stomal complications after ileal conduit urinary diversion are challenging and can negatively affect quality of life after radical cystectomy. Parastomal hernias (PHs) develop in up to half of patients; 30% to 75% are symptomatic, and up to one-third require surgical repair. Recurrence rates after local tissue repair are high, and relocation of the stoma requires closure of the original defect, placing both sites at risk for hernias. MATERIALS AND METHODS/UNASSIGNED:The primary aim of this randomized phase 3 trial was to test whether prophylactic placement of a parastomal mesh at ileal conduit formation reduced radiographic PH (rPH) rate compared with standard techniques without mesh; final rPH assessment was at 24 months. Ultrapro semiabsorbable mesh was placed in a sublay position dorsal to rectus muscle and anterior to posterior rectus sheath. RESULTS/UNASSIGNED:= .2). CONCLUSIONS/UNASSIGNED:We were unable to identify a clinical benefit to prophylactic parastomal mesh placement. Based on these findings, mesh at the time of conduit creation should not be used to avoid PH formation.
PMID: 40779615
ISSN: 1527-3792
CID: 5951322
PSMA PET/CT Reporting: Real-Life Inconsistencies, Heterogeneity, and Underutilization of Scoring Systems and Interpretation Frameworks
Vargas, Hebert Alberto; Fanti, Stefano; Herrmann, Ken; Eiber, Mathias; Rowe, Steven P; Rivera, Adrian; Pitsoulakis, Evangelia; Becker, Anton; Woo, Sungmin; Loeb, Stacy
PMID: 41085399
ISSN: 1527-1315
CID: 5954662