Try a new search

Format these results:

Searched for:

person:ahmedi05

in-biosketch:true

Total Results:

12


Technical aspects of radiation therapy for anal cancer

Scher, Eli D; Ahmed, Inaya; Yue, Ning J; Jabbour, Salma K
Historically treated with surgery, current practice recommends anal carcinoma to be treated with a combination of chemotherapy and radiation. This review will examine the anatomy, modes of disease spread and recurrence, and evaluate the existing evidence for treatment options for these tumors. An in-depth examination of specific radiation therapy (RT) techniques-such as conventional 3D-conformal RT and intensity-modulated RT-will be discussed along with modern dose constraints. RT field arrangement, patient setup, and recommended gross and clinical target volume (CTV) contours will be considered. Areas in need of further investigation, such as the role in treatment for positron emission tomography (PET) will be explored.
PMCID:4074958
PMID: 24982768
ISSN: 2078-6891
CID: 5325282

High dose radiotherapy to automated implantable cardioverter-defibrillator: a case report and review of the literature

Ahmed, Inaya; Zou, Wei; Jabbour, Salma K
We report a case of successful full-dose chemoradiotherapy to stage IIIB nonsmall cell lung cancer (NSCLC) in a 59-year-old man with extensive cardiac history and an automated implantable cardioverter-defibrillator (AICD) located within the radiotherapeutic field. In this case, the AICD was a St. Jude Medical Fortify Assura VR 1257-40Q ICD, and it was implanted prophylactically during bypass grafting. Although we do not recommend routine radiotherapy dose to exceed recommended current guidelines due to the potential risks to the patient, this is a situation where relocation of the device was not possible. Fortunately, our patient was not AICD-dependent; so following much discussion and deliberation, the decision was made to treat the patient with AICD in place. The patient completed definitive chemoradiotherapy with concurrent cisplatin and etoposide and thoracic irradiation to 69.6 Gy. The minimum, maximum, and mean doses to the AICD directly were 13.5 Gy, 52.4 Gy, and 29.3 Gy, respectively. The device withstood full thoracic radiation dose, and the patient denied cardiac symptoms during the time before, during, and after completion of therapy. We sought to offer this case for both teaching and guidance in practice and to contribute to the published literature currently available in this area.
PMCID:4170744
PMID: 25276450
ISSN: 2090-6706
CID: 5325292