Subject- and resource-specific monitoring and proactive management of parallel radiofrequency transmission

Deniz, Cem M; Alon, Leeor; Brown, Ryan; Zhu, Yudong
PURPOSE: Develop a practical comprehensive package for proactive management of parallel radiofrequency (RF) transmission. METHODS: With a constrained optimization framework and predictive models from a prescan based multichannel calibration, we presented a method supporting design and optimization of parallel RF excitation pulses that accurately obey the forward/reflected peak and average power limits of the RF power amplifiers in parallel transmit imaging experiments and Bloch simulations. Moreover, local SAR limits were incorporated into the parallel RF excitation pulses using electromagnetic field simulations. Virtual transmit coils concept for minimization of reflected power (effecting subject-specific matching) was additionally demonstrated by leveraging experimentally calibrated power models. RESULTS: Incorporation of experimentally calibrated power prediction models resulted in accurate compliance with prescribed hardware and global specific absorption rate (SAR) limits. Incorporation of spatial average 10 g SAR models, facilitated by simplifying numerical approximations, provided assurance of patient safety. RF pulses designed with various constraints demonstrated excellent excitation fidelity-the normalized root-mean-square error of the simulated excitation profiles was 2.6% for the fully constrained pulses, comparable to that of the unconstrained pulses. An RF shimming example showed a reduction of the reflected-to-forward power ratio to 1.7% from a conventional approach's 8.1%. CONCLUSION: Using the presented RF pulse design method, effective proactive management of the multifaceted power and SAR limits was demonstrated in experimental and simulation studies. Magn Reson Med, 2015. (c) 2015 Wiley Periodicals, Inc.
PMCID:4721949
PMID: 26198052
ISSN: 1522-2594
CID: 1683892

Effects of Anatomical Differences on Electromagnetic Fields, SAR, and Temperature Change

Alon, Leeor; Deniz, Cem Murat; Carluccio, Giuseppe; Brown, Ryan; Sodickson, Daniel K; Collins, Christopher M
Electromagnetic field simulations are increasingly used to assure RF safety of patients during MRI exams. In practice, however, tissue property distribution of the patient being imaged is not known, but may be represented with a pre-existing model. Repeatedly, agreement in transmit magnetic (B1 +) field distributions between two geometries has been used to suggest agreement in heating distributions. Here we examine relative effects of anatomical differences on B1 + distribution, Specific Absorption Rate (SAR) and temperature change (DeltaT). Numerical simulations were performed for a single surface coil positioned adjacent a homogeneous phantom and bovine phantom, each with slight geometric variations, and adjacent two different human body models. Experimental demonstration was performed on a bovine phantom using MR thermometry and B1 + mapping. Simulations and experiments demonstrate that B1 + distributions in different samples can be well correlated, while notable difference in maximum SAR and DeltaT occur. This work illustrates challenges associated with utilizing simulations or experiments for RF safety assurance purposes. Reliance on B1 + distributions alone for validation of simulations and/or experiments with a sample or subject for assurance of safety in another should be performed with caution.
PMCID:4847547
PMID: 27134586
ISSN: 1552-5031
CID: 2101092

Radiofrequency energy deposition and radiofrequency power requirements in parallel transmission with increasing distance from the coil to the sample

Deniz, Cem M; Vaidya, Manushka V; Sodickson, Daniel K; Lattanzi, Riccardo
PURPOSE: We investigated global specific absorption rate (SAR) and radiofrequency (RF) power requirements in parallel transmission as the distance between the transmit coils and the sample was increased. METHODS: We calculated ultimate intrinsic SAR (UISAR), which depends on object geometry and electrical properties but not on coil design, and we used it as the reference to compare the performance of various transmit arrays. We investigated the case of fixing coil size and increasing the number of coils while moving the array away from the sample, as well as the case of fixing coil number and scaling coil dimensions. We also investigated RF power requirements as a function of lift-off, and tracked local SAR distributions associated with global SAR optima. RESULTS: In all cases, the target excitation profile was achieved and global SAR (as well as associated maximum local SAR) decreased with lift-off, approaching UISAR, which was constant for all lift-offs. We observed a lift-off value that optimizes the balance between global SAR and power losses in coil conductors. We showed that, using parallel transmission, global SAR can decrease at ultra high fields for finite arrays with a sufficient number of transmit elements. CONCLUSION: For parallel transmission, the distance between coils and object can be optimized to reduce SAR and minimize RF power requirements associated with homogeneous excitation. Magn Reson Med, 2015. (c) 2015 Wiley Periodicals, Inc.
PMCID:4561044
PMID: 25752250
ISSN: 0740-3194
CID: 1494622

A method for safety testing of radiofrequency/microwave-emitting devices using MRI

Alon, Leeor; Cho, Gene Y; Yang, Xing; Sodickson, Daniel K; Deniz, Cem M
PURPOSE: Strict regulations are imposed on the amount of radiofrequency (RF) energy that devices can emit to prevent excessive deposition of RF energy into the body. In this study, we investigated the application of MR temperature mapping and 10-g average specific absorption rate (SAR) computation for safety evaluation of RF-emitting devices. METHODS: Quantification of the RF power deposition was shown for an MRI-compatible dipole antenna and a non-MRI-compatible mobile phone via phantom temperature change measurements. Validation of the MR temperature mapping method was demonstrated by comparison with physical temperature measurements and electromagnetic field simulations. MR temperature measurements alongside physical property measurements were used to reconstruct 10-g average SAR. RESULTS: The maximum temperature change for a dipole antenna and the maximum 10-g average SAR were 1.83 degrees C and 12.4 W/kg, respectively, for simulations and 1.73 degrees C and 11.9 W/kg, respectively, for experiments. The difference between MR and probe thermometry was <0.15 degrees C. The maximum temperature change and the maximum 10-g average SAR for a cell phone radiating at maximum output for 15 min was 1.7 degrees C and 0.54 W/kg, respectively. CONCLUSION: Information acquired using MR temperature mapping and thermal property measurements can assess RF/microwave safety with high resolution and fidelity. Magn Reson Med, 2014. (c) 2014 Wiley Periodicals, Inc.
PMCID:4442746
PMID: 25424724
ISSN: 0740-3194
CID: 1359712

Finite Element Analysis Applied to 3-T MR Imaging of Proximal Femur Microarchitecture: Lower Bone Strength in Patients with Fragility Fractures Compared with Control Subjects

Chang, Gregory; Honig, Stephen; Brown, Ryan; Deniz, Cem M; Egol, Kenneth A; Babb, James S; Regatte, Ravinder R; Rajapakse, Chamith S
Purpose To determine the feasibility of using finite element analysis applied to 3-T magnetic resonance (MR) images of proximal femur microarchitecture for detection of lower bone strength in subjects with fragility fractures compared with control subjects without fractures. Materials and Methods This prospective study was institutional review board approved and HIPAA compliant. Written informed consent was obtained. Postmenopausal women with (n = 22) and without (n = 22) fragility fractures were matched for age and body mass index. All subjects underwent standard dual-energy x-ray absorptiometry. Images of proximal femur microarchitecture were obtained by using a high-spatial-resolution three-dimensional fast low-angle shot sequence at 3 T. Finite element analysis was applied to compute elastic modulus as a measure of strength in the femoral head and neck, Ward triangle, greater trochanter, and intertrochanteric region. The Mann-Whitney test was used to compare bone mineral density T scores and elastic moduli between the groups. The relationship (R2) between elastic moduli and bone mineral density T scores was assessed. Results Patients with fractures showed lower elastic modulus than did control subjects in all proximal femur regions (femoral head, 8.51-8.73 GPa vs 9.32-9.67 GPa; P = .04; femoral neck, 3.11-3.72 GPa vs 4.39-4.82 GPa; P = .04; Ward triangle, 1.85-2.21 GPa vs 3.98-4.13 GPa; P = .04; intertrochanteric region, 1.62-2.18 GPa vs 3.86-4.47 GPa; P = .006-.007; greater trochanter, 0.65-1.21 GPa vs 1.96-2.62 GPa; P = .01-.02), but no differences in bone mineral density T scores. There were weak relationships between elastic moduli and bone mineral density T scores in patients with fractures (R2 = 0.25-0.31, P = .02-.04), but not in control subjects. Conclusion Finite element analysis applied to high-spatial-resolution 3-T MR images of proximal femur microarchitecture can allow detection of lower elastic modulus, a marker of bone strength, in subjects with fragility fractures compared with control subjects. MR assessment of proximal femur strength may provide information about bone quality that is not provided by dual-energy x-ray absorptiometry. (c) RSNA, 2014.
PMCID:4263634
PMID: 24689884
ISSN: 0033-8419
CID: 895822

Feasibility of three-dimensional MRI of proximal femur microarchitecture at 3 tesla using 26 receive elements without and with parallel imaging

Chang, Gregory; Deniz, Cem M; Honig, Stephen; Rajapakse, Chamith S; Egol, Kenneth; Regatte, Ravinder R; Brown, Ryan
PURPOSE: High-resolution imaging of deeper anatomy such as the hip is challenging due to low signal-to-noise ratio (SNR), necessitating long scan times. Multi-element coils can increase SNR and reduce scan time through parallel imaging (PI). We assessed the feasibility of using a 26-element receive coil setup to perform 3 Tesla (T) MRI of proximal femur microarchitecture without and with PI. MATERIALS AND METHODS: This study had institutional review board approval. We scanned 13 subjects on a 3T scanner using 26 receive-elements and a three-dimensional fast low-angle shot (FLASH) sequence without and with PI (acceleration factors [AF] 2, 3, 4). We assessed SNR, depiction of individual trabeculae, PI performance (1/g-factor), and image quality with PI (1 = nonvisualization to 5 = excellent). RESULTS: SNR maps demonstrate higher SNR for the 26-element setup compared with a 12-element setup for hip MRI. Without PI, individual proximal femur trabeculae were well-depicted, including microarchitectural deterioration in osteoporotic subjects. With PI, 1/g values for the 26-element/12-element receive-setup were 0.71/0.45, 0.56/0.25, and 0.44/0.08 at AF2, AF3, and AF4, respectively. Image quality was: AF1, excellent (4.8 +/- 0.4); AF2, good (4.2 +/- 1.0); AF3, average (3.3 +/- 1.0); AF4, nonvisualization (1.4 +/- 0.9). CONCLUSION: A 26-element receive-setup permits 3T MRI of proximal femur microarchitecture with good image quality up to PI AF2. J. Magn. Reson. Imaging 2014;40:229-238. (c) 2013 Wiley Periodicals, Inc.
PMCID:4004721
PMID: 24711013
ISSN: 1053-1807
CID: 1042112

MRI of the hip at 7T: Feasibility of bone microarchitecture, high-resolution cartilage, and clinical imaging

Chang, Gregory; Deniz, Cem M; Honig, Stephen; Egol, Kenneth; Regatte, Ravinder R; Zhu, Yudong; Sodickson, Daniel K; Brown, Ryan
PURPOSE: To demonstrate the feasibility of performing bone microarchitecture, high-resolution cartilage, and clinical imaging of the hip at 7T. MATERIALS AND METHODS: This study had Institutional Review Board approval. Using an 8-channel coil constructed in-house, we imaged the hips of 15 subjects on a 7T magnetic resonance imaging (MRI) scanner. We applied: 1) a T1-weighted 3D fast low angle shot (3D FLASH) sequence (0.23 x 0.23 x 1-1.5 mm3 ) for bone microarchitecture imaging; 2) T1-weighted 3D FLASH (water excitation) and volumetric interpolated breath-hold examination (VIBE) sequences (0.23 x 0.23 x 1.5 mm3 ) with saturation or inversion recovery-based fat suppression for cartilage imaging; 3) 2D intermediate-weighted fast spin-echo (FSE) sequences without and with fat saturation (0.27 x 0.27 x 2 mm) for clinical imaging. RESULTS: Bone microarchitecture images allowed visualization of individual trabeculae within the proximal femur. Cartilage was well visualized and fat was well suppressed on FLASH and VIBE sequences. FSE sequences allowed visualization of cartilage, the labrum (including cartilage and labral pathology), joint capsule, and tendons. CONCLUSION: This is the first study to demonstrate the feasibility of performing a clinically comprehensive hip MRI protocol at 7T, including high-resolution imaging of bone microarchitecture and cartilage, as well as clinical imaging. J. Magn. Reson. Imaging 2013;. (c) 2013 Wiley Periodicals, Inc.
PMCID:3962810
PMID: 24115554
ISSN: 1053-1807
CID: 571382

Design and Application of Combined 8-Channel Transmit and 10-Channel Receive Arrays and Radiofrequency Shimming for 7-T Shoulder Magnetic Resonance Imaging

Brown, Ryan; Deniz, Cem Murat; Zhang, Bei; Chang, Gregory; Sodickson, Daniel K; Wiggins, Graham C
OBJECTIVE: The objective of the study was to investigate the feasibility of 7-T shoulder magnetic resonance imaging by developing transmit and receive radiofrequency (RF) coil arrays and exploring RF shim methods. MATERIALS AND METHODS: A mechanically flexible 8-channel transmit array and an anatomically conformable 10-channel receive array were designed and implemented. The transmit performance of various RF shim methods was assessed through local flip angle measurements in the right and left shoulders of 6 subjects. The receive performance was assessed through signal-to-noise ratio measurements using the developed 7-T coil and a baseline commercial 3-T coil. RESULTS: The 7-T transmit array driven with phase-coherent RF shim weights provided adequate B1 efficiency and uniformity for turbo spin echo shoulder imaging. B1 twisting that is characteristic of high-field loop coils necessitates distinct RF shim weights in the right and left shoulders. The 7-T receive array provided a 2-fold signal-to-noise ratio improvement over the 3-T array in the deep articular shoulder cartilage. CONCLUSIONS: Shoulder imaging at 7-T is feasible with a custom transmit/receive array either in a single-channel transmit mode with a fixed RF shim or in a parallel transmit mode with a subject-specific RF shim.
PMCID:4036121
PMID: 24056112
ISSN: 0020-9996
CID: 571392

A Fast Method to Estimate SAR Distribution from Temperature Images Highly Affected by Noise [Meeting Abstract]

Carluccio, Giuseppe; Knoll, Florian; Deniz, Cem Murat; Alon, Leeor; Collins, Chistopher Michael
ORIGINAL:0014708
ISSN: 1524-6965
CID: 4534582

Maximum efficiency radiofrequency shimming: Theory and initial application for hip imaging at 7 tesla

Deniz, Cem Murat; Brown, Ryan; Lattanzi, Riccardo; Alon, Leeor; Sodickson, Daniel K; Zhu, Yudong
Radiofrequency shimming with multiple channel excitation has been proposed to increase the transverse magnetic field uniformity and reduce specific absorption rate at high magnetic field strengths (>/=7 T) where high-frequency effects can make traditional single channel volume coils unsuitable for transmission. In the case of deep anatomic regions and power-demanding pulse sequences, optimization of transmit efficiency may be a more critical requirement than homogeneity per se. This work introduces a novel method to maximize transmit efficiency using multiple channel excitation and radiofrequency shimming. Shimming weights are calculated in order to obtain the lowest possible net radiofrequency power deposition into the subject for a given transverse magnetic field strength. The method was demonstrated in imaging studies of articular cartilage of the hip joint at 7 T. We show that the new radiofrequency shimming method can enable reduction in power deposition while maintaining an average flip angle or adiabatic condition in the hip cartilage. Building upon the improved shimming, we further show that the signal-to-noise ratio in hip cartilage at 7 T can be substantially greater than that at 3 T, illustrating the potential benefits of high field hip imaging. Magn Reson Med, 2012. (c) 2012 Wiley Periodicals, Inc.
PMCID:3478493
PMID: 22714835
ISSN: 0740-3194
CID: 221072