Try a new search

Format these results:

Searched for:

person:fieree01

Total Results:

110


Removal of partial Fourier-induced Gibbs (RPG) ringing artifacts in MRI

Lee, Hong-Hsi; Novikov, Dmitry S; Fieremans, Els
PURPOSE/OBJECTIVE:To investigate and remove Gibbs-ringing artifacts caused by partial Fourier (PF) acquisition and zero filling interpolation in MRI data. THEORY AND METHODS/UNASSIGNED:Gibbs ringing of fully sampled data, leading to oscillations around tissue boundaries, is caused by the symmetric truncation of k-space. Such ringing can be removed by conventional methods, with the local subvoxel shifts method being the state-of-the-art. However, the asymmetric truncation of k-space in routinely used PF acquisitions leads to additional ringings of wider intervals in the PF sampling dimension that cannot be corrected solely based on magnitude images reconstructed via zero filling. Here, we develop a pipeline for the Removal of PF-induced Gibbs ringing (RPG) to remove ringing patterns of different periods by applying the conventional method twice. The proposed pipeline is validated on numerical phantoms, demonstrated on in vivo diffusion MRI measurements, and compared with the conventional method and neural network-based approach. RESULTS:For PF = 7/8 and 6/8, Gibbs-ringings and subsequent bias in diffusion metrics induced by PF acquisition and zero filling are robustly removed by using the proposed RPG pipeline. For PF = 5/8, however, ringing removal via RPG leads to excessive image blurring due to the interplay of image phase and convolution kernel. CONCLUSIONS:RPG corrects Gibbs-ringing artifacts in magnitude images of PF acquired data and reduces the bias in quantitative MR metrics. Considering the benefit of PF acquisition and the feasibility of ringing removal, we suggest applying PF = 6/8 when PF acquisition is necessary.
PMID: 34227142
ISSN: 1522-2594
CID: 4932162

Connectome 2.0: Developing the next-generation ultra-high gradient strength human MRI scanner for bridging studies of the micro-, meso- and macro-connectome

Huang, Susie Y; Witzel, Thomas; Keil, Boris; Scholz, Alina; Davids, Mathias; Dietz, Peter; Rummert, Elmar; Ramb, Rebecca; Kirsch, John E; Yendiki, Anastasia; Fan, Qiuyun; Tian, Qiyuan; Ramos-Llordén, Gabriel; Lee, Hong-Hsi; Nummenmaa, Aapo; Bilgic, Berkin; Setsompop, Kawin; Wang, Fuyixue; Avram, Alexandru V; Komlosh, Michal; Benjamini, Dan; Magdoom, Kulam Najmudeen; Pathak, Sudhir; Schneider, Walter; Novikov, Dmitry S; Fieremans, Els; Tounekti, Slimane; Mekkaoui, Choukri; Augustinack, Jean; Berger, Daniel; Shapson-Coe, Alexander; Lichtman, Jeff; Basser, Peter J; Wald, Lawrence L; Rosen, Bruce R
The first phase of the Human Connectome Project pioneered advances in MRI technology for mapping the macroscopic structural connections of the living human brain through the engineering of a whole-body human MRI scanner equipped with maximum gradient strength of 300 mT/m, the highest ever achieved for human imaging. While this instrument has made important contributions to the understanding of macroscale connectional topology, it has also demonstrated the potential of dedicated high-gradient performance scanners to provide unparalleled in vivo assessment of neural tissue microstructure. Building on the initial groundwork laid by the original Connectome scanner, we have now embarked on an international, multi-site effort to build the next-generation human 3T Connectome scanner (Connectome 2.0) optimized for the study of neural tissue microstructure and connectional anatomy across multiple length scales. In order to maximize the resolution of this in vivo microscope for studies of the living human brain, we will push the diffusion resolution limit to unprecedented levels by (1) nearly doubling the current maximum gradient strength from 300 mT/m to 500 mT/m and tripling the maximum slew rate from 200 T/m/s to 600 T/m/s through the design of a one-of-a-kind head gradient coil optimized to minimize peripheral nerve stimulation; (2) developing high-sensitivity multi-channel radiofrequency receive coils for in vivo and ex vivo human brain imaging; (3) incorporating dynamic field monitoring to minimize image distortions and artifacts; (4) developing new pulse sequences to integrate the strongest diffusion encoding and highest spatial resolution ever achieved in the living human brain; and (5) calibrating the measurements obtained from this next-generation instrument through systematic validation of diffusion microstructural metrics in high-fidelity phantoms and ex vivo brain tissue at progressively finer scales with accompanying diffusion simulations in histology-based micro-geometries. We envision creating the ultimate diffusion MRI instrument capable of capturing the complex multi-scale organization of the living human brain - from the microscopic scale needed to probe cellular geometry, heterogeneity and plasticity, to the mesoscopic scale for quantifying the distinctions in cortical structure and connectivity that define cyto- and myeloarchitectonic boundaries, to improvements in estimates of macroscopic connectivity.
PMID: 34464739
ISSN: 1095-9572
CID: 4998402

Simultaneous Multislice for Accelerating Diffusion MRI in Clinical Neuroradiology Protocols

Hoch, M J; Bruno, M; Pacione, D; Lui, Y W; Fieremans, E; Shepherd, T M
BACKGROUND AND PURPOSE/OBJECTIVE:Diffusion MR imaging sequences essential for clinical neuroradiology imaging protocols may be accelerated with simultaneous multislice acquisitions. We tested whether simultaneous multislice-accelerated diffusion data were clinically equivalent to standard acquisitions. MATERIALS AND METHODS/METHODS:; 60 directions). The corticospinal tract and arcuate fasciculus ipsilateral to the lesion were generated using the same ROIs and then blindly assessed by a neurosurgeon for anatomic fidelity, perceived quality, and impact on surgical management. Tract volumes were compared for spatial overlap. RESULTS:Two-slice simultaneous multislice diffusion reduced acquisition times from 141 to 45 seconds for routine diffusion and from 7.5 to 5.9 minutes for diffusion tractography using 3T MR imaging. The simultaneous multislice-accelerated diffusion sequence was rated equivalent for diagnostic utility despite reductions to perceived image quality. Simultaneous multislice-accelerated diffusion tractography was rated clinically equivalent. Dice similarity coefficients between routine and simultaneous multislice-generated corticospinal tract and arcuate fasciculus tract volumes were 0.78 (SD, 0.03) and 0.71 (SD, 0.05), respectively. CONCLUSIONS:-space-resolution diffusion acquisitions required for translating advanced diffusion models into clinical practice.
PMID: 33985946
ISSN: 1936-959x
CID: 4868222

Nanostructure-specific X-ray tomography reveals myelin levels, integrity and axon orientations in mouse and human nervous tissue

Georgiadis, Marios; Schroeter, Aileen; Gao, Zirui; Guizar-Sicairos, Manuel; Liebi, Marianne; Leuze, Christoph; McNab, Jennifer A; Balolia, Aleezah; Veraart, Jelle; Ades-Aron, Benjamin; Kim, Sunglyoung; Shepherd, Timothy; Lee, Choong H; Walczak, Piotr; Chodankar, Shirish; DiGiacomo, Phillip; David, Gergely; Augath, Mark; Zerbi, Valerio; Sommer, Stefan; Rajkovic, Ivan; Weiss, Thomas; Bunk, Oliver; Yang, Lin; Zhang, Jiangyang; Novikov, Dmitry S; Zeineh, Michael; Fieremans, Els; Rudin, Markus
Myelin insulates neuronal axons and enables fast signal transmission, constituting a key component of brain development, aging and disease. Yet, myelin-specific imaging of macroscopic samples remains a challenge. Here, we exploit myelin's nanostructural periodicity, and use small-angle X-ray scattering tensor tomography (SAXS-TT) to simultaneously quantify myelin levels, nanostructural integrity and axon orientations in nervous tissue. Proof-of-principle is demonstrated in whole mouse brain, mouse spinal cord and human white and gray matter samples. Outcomes are validated by 2D/3D histology and compared to MRI measurements sensitive to myelin and axon orientations. Specificity to nanostructure is exemplified by concomitantly imaging different myelin types with distinct periodicities. Finally, we illustrate the method's sensitivity towards myelin-related diseases by quantifying myelin alterations in dysmyelinated mouse brain. This non-destructive, stain-free molecular imaging approach enables quantitative studies of myelination within and across samples during development, aging, disease and treatment, and is applicable to other ordered biomolecules or nanostructures.
PMID: 34011929
ISSN: 2041-1723
CID: 4877382

Assessment of myofiber microstructure changes due to atrophy and recovery with time-dependent diffusion MRI

Lemberskiy, Gregory; Feiweier, Thorsten; Gyftopoulos, Soterios; Axel, Leon; Novikov, Dmitry S; Fieremans, Els
Current clinical MRI evaluation of musculature largely focuses on nonquantitative assessments (including T1-, T2- and PD-weighted images), which may vary greatly between imaging systems and readers. This work aims to determine the efficacy of a quantitative approach to study the microstructure of muscles at the cellular level with the random permeable barrier model (RPBM) applied to time-dependent diffusion tensor imaging (DTI) for varying diffusion time. Patients (N = 15, eight males and seven females) with atrophied calf muscles due to immobilization of one leg in a nonweight-bearing cast, were enrolled after providing informed consent. Their calf muscles were imaged with stimulated echo diffusion for DTI, T1-mapping and RPBM modeling. Specifically, After cast removal, both calf muscles (atrophied and contralateral control leg) were imaged with MRI for all patients, with follow-up scans to monitor recovery of the atrophied leg for six patients after 4 and 8 weeks. We compare RPBM-derived microstructural metrics: myofiber diameter, a, and sarcolemma permeability, κ, along with macroscopic anatomical parameters (muscle cross-sectional area, fiber orientation, <θ>, and T1 relaxation). ROC analysis was used to compare parameters between control and atrophied muscle, while the Friedman test was used to evaluate the atrophied muscle longitudinally. We found that the RPBM framework enables measurement of microstructural parameters from diffusion time-dependent DTI, of which the myofiber diameter is a stronger predictor of intramuscular morphological changes than either macroscopic (anatomical) measurements or empirical diffusion parameters. This work demonstrates the potential of RPBM to assess pathological changes in musculature that seem undetectable with standard diffusion and anatomical MRI.
PMID: 34002901
ISSN: 1099-1492
CID: 4876922

Measurement of cellular-interstitial water exchange time in tumors based on diffusion-time-dependent diffusional kurtosis imaging

Zhang, Jin; Lemberskiy, Gregory; Moy, Linda; Fieremans, Els; Novikov, Dmitry S; Kim, Sungheon Gene
PURPOSE/OBJECTIVE:) in tumors, both in animals and in humans. METHODS:) by adjusting the diffusion gradient strength. The tDKI data at each diffusion time t were used for a weighted linear least-squares fit method to estimate the diffusion-time-dependent diffusivity, D(t), and diffusional kurtosis, K(t). RESULTS:median and IQR of the two breast cancers were 70 (94) and 106 (92) ms. CONCLUSION/CONCLUSIONS:The results of this proof-of-concept study substantiate the feasibility of using tDKI to measure cellular-interstitial water exchange time without using an exogenous contrast agent.
PMID: 33634508
ISSN: 1099-1492
CID: 4795052

Training a neural network for Gibbs and noise removal in diffusion MRI

Muckley, Matthew J; Ades-Aron, Benjamin; Papaioannou, Antonios; Lemberskiy, Gregory; Solomon, Eddy; Lui, Yvonne W; Sodickson, Daniel K; Fieremans, Els; Novikov, Dmitry S; Knoll, Florian
PURPOSE/OBJECTIVE:To develop and evaluate a neural network-based method for Gibbs artifact and noise removal. METHODS:A convolutional neural network (CNN) was designed for artifact removal in diffusion-weighted imaging data. Two implementations were considered: one for magnitude images and one for complex images. Both models were based on the same encoder-decoder structure and were trained by simulating MRI acquisitions on synthetic non-MRI images. RESULTS:Both machine learning methods were able to mitigate artifacts in diffusion-weighted images and diffusion parameter maps. The CNN for complex images was also able to reduce artifacts in partial Fourier acquisitions. CONCLUSIONS:The proposed CNNs extend the ability of artifact correction in diffusion MRI. The machine learning method described here can be applied on each imaging slice independently, allowing it to be used flexibly in clinical applications.
PMID: 32662910
ISSN: 1522-2594
CID: 4528102

The brain after COVID-19: Compensatory neurogenesis or persistent neuroinflammation?

Goldberg, Elkhonon; Podell, Kenneth; Sodickson, Daniel K; Fieremans, Els
PMCID:7773850
PMID: 33409480
ISSN: 2589-5370
CID: 4771262

Improved Task-based Functional MRI Language Mapping in Patients with Brain Tumors through Marchenko-Pastur Principal Component Analysis Denoising

Ades-Aron, Benjamin; Lemberskiy, Gregory; Veraart, Jelle; Golfinos, John; Fieremans, Els; Novikov, Dmitry S; Shepherd, Timothy
Background Functional MRI improves preoperative planning in patients with brain tumors, but task-correlated signal intensity changes are only 2%-3% above baseline. This makes accurate functional mapping challenging. Marchenko-Pastur principal component analysis (MP-PCA) provides a novel strategy to separate functional MRI signal from noise without requiring user input or prior data representation. Purpose To determine whether MP-PCA denoising improves activation magnitude for task-based functional MRI language mapping in patients with brain tumors. Materials and Methods In this Health Insurance Portability and Accountability Act-compliant study, MP-PCA performance was first evaluated by using simulated functional MRI data with a known ground truth. Right-handed, left-language-dominant patients with brain tumors who successfully performed verb generation, sentence completion, and finger tapping functional MRI tasks were retrospectively identified between January 2017 and August 2018. On the group level, for each task, histograms of z scores for original and MP-PCA denoised data were extracted from relevant regions and contralateral homologs were seeded by a neuroradiologist blinded to functional MRI findings. Z scores were compared with paired two-sided t tests, and distributions were compared with effect size measurements and the Kolmogorov-Smirnov test. The number of voxels with a z score greater than 3 was used to measure task sensitivity relative to task duration. Results Twenty-three patients (mean age ± standard deviation, 43 years ± 18; 13 women) were evaluated. MP-PCA denoising led to a higher median z score of task-based functional MRI voxel activation in left hemisphere cortical regions for verb generation (from 3.8 ± 1.0 to 4.5 ± 1.4; P < .001), sentence completion (from 3.7 ± 1.0 to 4.3 ± 1.4; P < .001), and finger tapping (from 6.9 ± 2.4 to 7.9 ± 2.9; P < .001). Median z scores did not improve in contralateral homolog regions for verb generation (from -2.7 ± 0.54 to -2.5 ± 0.40; P = .90), sentence completion (from -2.3 ± 0.21 to -2.4 ± 0.37; P = .39), or finger tapping (from -2.3 ± 1.20 to -2.7 ± 1.40; P = .07). Individual functional MRI task durations could be truncated by at least 40% after MP-PCA without degradation of clinically relevant correlations between functional cortex and functional MRI tasks. Conclusion Denoising with Marchenko-Pastur principal component analysis led to higher task correlations in relevant cortical regions during functional MRI language mapping in patients with brain tumors. © RSNA, 2020 Online supplemental material is available for this article.
PMID: 33289611
ISSN: 1527-1315
CID: 4708782

Realistic Microstructure Simulator (RMS): Monte Carlo simulations of diffusion in three-dimensional cell segmentations of microscopy images

Lee, Hong-Hsi; Fieremans, Els; Novikov, Dmitry S
BACKGROUND:Monte Carlo simulations of diffusion are commonly used as a model validation tool as they are especially suitable for generating the diffusion MRI signal in complicated tissue microgeometries. New method: Here we describe the details of implementing Monte Carlo simulations in three-dimensional (3d) voxelized segmentations of cells in microscopy images. Using the concept of the corner reflector, we largely reduce the computational load of simulating diffusion within and exchange between multiple cells. Precision is further achieved by GPU-based parallel computations. RESULTS:Our simulation result of diffusion in the exemplified white matter axons segmented from a mouse brain demonstrates its power and value in validations of biophysical models. Furthermore, we provide the theoretical background for implementing a discretized diffusion process, and consider the finite-step effects of the particle-membrane reflection and permeation events, needed for efficient simulation of interactions with irregular boundaries, variable diffusion coefficient, and exchange. Comparison with existing methods: To our knowledge, this is the first Monte Carlo pipeline for MR signal simulations in a substrate composed of numerous realistic cells, accounting for their permeable and irregularly-shaped membranes. CONCLUSIONS:effects and flow.
PMID: 33279478
ISSN: 1872-678x
CID: 4708422