Try a new search

Format these results:

Searched for:

person:fowles01

Total Results:

45


Use of Whole Exome Sequencing for the Identification of Ito Based Arrhythmia Mechanism and Therapy [Meeting Abstract]

Adelman, Sara H.; Sturm, Amy C.; Kline, Crystal F.; Glynn, Patric; Johnson, Benjamin L.; Curran, Jerry; Kilic, Ahmet; Higgins, Robert S.; Binkley, Philip F.; Janssen, Paul M.; Weiss, Raul; Raman, Subha V.; Fowler, Steven J.; Priori, Silvia G.; Hund, Thomas J.; Carnes, Cynthia A.; Mohler, Peter J.
ISI:000381010601030
ISSN: 0009-7322
CID: 2961732

Three-Dimensional Transesophageal Echocardiography to Facilitate Transseptal Puncture and Left Atrial Appendage Occlusion via Upper Extremity Venous Access

Aizer, Anthony; Young, Wilson; Saric, Muhamed; Holmes, Douglas; Fowler, Steven; Chinitz, Larry
PMID: 26286309
ISSN: 1941-3084
CID: 1732232

Use of whole exome sequencing for the identification of ito-based arrhythmia mechanism and therapy

Sturm, Amy C; Kline, Crystal F; Glynn, Patric; Johnson, Benjamin L; Curran, Jerry; Kilic, Ahmet; Higgins, Robert S D; Binkley, Philip F; Janssen, Paul M L; Weiss, Raul; Raman, Subha V; Fowler, Steven J; Priori, Silvia G; Hund, Thomas J; Carnes, Cynthia A; Mohler, Peter J
BACKGROUND: Identified genetic variants are insufficient to explain all cases of inherited arrhythmia. We tested whether the integration of whole exome sequencing with well-established clinical, translational, and basic science platforms could provide rapid and novel insight into human arrhythmia pathophysiology and disease treatment. METHODS AND RESULTS: We report a proband with recurrent ventricular fibrillation, resistant to standard therapeutic interventions. Using whole-exome sequencing, we identified a variant in a previously unidentified exon of the dipeptidyl aminopeptidase-like protein-6 (DPP6) gene. This variant is the first identified coding mutation in DPP6 and augments cardiac repolarizing current (Ito) causing pathological changes in Ito and action potential morphology. We designed a therapeutic regimen incorporating dalfampridine to target Ito. Dalfampridine, approved for multiple sclerosis, normalized the ECG and reduced arrhythmia burden in the proband by >90-fold. This was combined with cilostazol to accelerate the heart rate to minimize the reverse-rate dependence of augmented Ito. CONCLUSIONS: We describe a novel arrhythmia mechanism and therapeutic approach to ameliorate the disease. Specifically, we identify the first coding variant of DPP6 in human ventricular fibrillation. These findings illustrate the power of genetic approaches for the elucidation and treatment of disease when carefully integrated with clinical and basic/translational research teams.
PMCID:4599408
PMID: 26015324
ISSN: 2047-9980
CID: 1602982

Effect of Obstructive Sleep Apnea Treatment on Atrial Fibrillation Recurrence: A Meta-Analysis

Shukla, Ashish; Aizer, Anthony; Holmes, Douglas; Fowler, Steven; Park, David S; Bernstein, Scott; Bernstein, Neil; Chinitz, Larry
OBJECTIVES/OBJECTIVE:This study aimed to evaluate the cumulative effect of treatment of obstructive sleep apnea (OSA) with continuous positive airway pressure (CPAP) on atrial fibrillation (AF) recurrence. BACKGROUND:OSA is a known predictor for onset and recurrence of AF. The effect of treatment with CPAP on AF recurrence has been evaluated in small studies with varied outcomes. METHODS:We searched MEDLINE, EMBASE, CINAHL, Google Scholar, Cochrane Database of Systematic Reviews, and Cochrane Trials Register for relevant studies. Evaluation of AF recurrence in CPAP users and nonusers in patients with OSA was the primary outcome evaluated in this study. The secondary outcome was evaluation of AF recurrence in CPAP users and nonusers after pulmonary vein isolation (PVI). RESULTS: = 0%). The beneficial effect of CPAP use was statistically significant in both groups of patients: those who underwent catheter ablation with PVI and those who did not undergo ablation and were managed medically. No other study covariates had any significant association with these outcomes of AF reduction. CONCLUSIONS:The use of CPAP is associated with significant reduction in recurrence of AF in patients with OSA. This effect remains consistent and similar across patient populations irrespective of whether they undergo PVI.
PMID: 29759338
ISSN: 2405-5018
CID: 3114672

Genetically engineered SCN5A mutant pig hearts exhibit conduction defects and arrhythmias

Park, David S; Cerrone, Marina; Morley, Gregory; Vasquez, Carolina; Fowler, Steven; Liu, Nian; Bernstein, Scott A; Liu, Fang-Yu; Zhang, Jie; Rogers, Christopher S; Priori, Silvia G; Chinitz, Larry A; Fishman, Glenn I
SCN5A encodes the alpha subunit of the major cardiac sodium channel NaV1.5. Mutations in SCN5A are associated with conduction disease and ventricular fibrillation (VF); however, the mechanisms that link loss of sodium channel function to arrhythmic instability remain unresolved. Here, we generated a large-animal model of a human cardiac sodium channelopathy in pigs, which have cardiac structure and function similar to humans, to better define the arrhythmic substrate. We introduced a nonsense mutation originally identified in a child with Brugada syndrome into the orthologous position (E558X) in the pig SCN5A gene. SCN5AE558X/+ pigs exhibited conduction abnormalities in the absence of cardiac structural defects. Sudden cardiac death was not observed in young pigs; however, Langendorff-perfused SCN5AE558X/+ hearts had an increased propensity for pacing-induced or spontaneous VF initiated by short-coupled ventricular premature beats. Optical mapping during VF showed that activity often began as an organized focal source or broad wavefront on the right ventricular (RV) free wall. Together, the results from this study demonstrate that the SCN5AE558X/+ pig model accurately phenocopies many aspects of human cardiac sodium channelopathy, including conduction slowing and increased susceptibility to ventricular arrhythmias.
PMCID:4382241
PMID: 25500882
ISSN: 0021-9738
CID: 1410832

Atrial fibrillation ablation in patients with known sludge in the left atrial appendage

Hajjiri, Mohammed; Bernstein, Scott; Saric, Muhamed; Benenstein, Ricardo; Aizer, Anthony; Dym, Glenn; Fowler, Steven; Holmes, Douglas; Bernstein, Neil; Mascarenhas, Mark; Park, David; Chinitz, Larry
PURPOSE: Transesophageal echocardiography (TEE) is routinely used to assess for thrombus in the left atrium (LA) and left atrial appendage (LAA) in patients undergoing atrial fibrillation (AF) ablation. However, little is known about the outcome of AF ablation in patients with documented LAA sludge. We hypothesize that AF ablation can be performed safely in a proportion of patients with sludge in the LAA and may have a significant benefit for these patients. METHODS: We performed a retrospective analysis of all patients undergoing AF ablation at New York University Langone Medical Center (NYULMC) from January 1st 2011 to June 30, 2013. Patients with sludge found on their TEE immediately prior to AF ablation were identified and followed for stroke, AF recurrence, procedural complications, major bleeding, or death. RESULTS: Among 1,076 patients who underwent AF ablation, 8 patients (mean age 69 +/- 13 years; 75 % men) with sludge were identified. Patients with sludge in their LAA had no incidence of early or late occurrence of stroke during mean follow-up of 10 months. One patient had a left groin hematoma, and two patients had atrial tachycardias that needed a repeat ablation. TEE at the time of repeat ablation demonstrated the presence of spontaneous echo contrast (smoke) and resolution of sludge. There were no deaths. CONCLUSION: In a cohort of eight patients with LAA sludge who underwent AF ablation, no significant thromboembolic events occurred during or after the procedure. AF ablation can be performed safely and may be beneficial in these patients. Larger studies are warranted to better determine the most appropriate management route.
PMID: 24752792
ISSN: 1383-875x
CID: 909162

Spinal cord stimulation protects against atrial fibrillation induced by tachypacing

Bernstein, Scott A; Wong, Brian; Vasquez, Carolina; Rosenberg, Stuart P; Rooke, Ryan; Kuznekoff, Laura M; Lader, Joshua M; Mahoney, Vanessa M; Budylin, Tatyana; Alvstrand, Marie; Rakowski-Anderson, Tammy; Bharmi, Rupinder; Shah, Riddhi; Fowler, Steven; Holmes, Douglas; Farazi, Taraneh G; Chinitz, Larry A; Morley, Gregory E
BACKGROUND: Spinal cord stimulation (SCS) has been shown to modulate atrial electrophysiology and confer protection against ischemia and ventricular arrhythmias in animal models. OBJECTIVE: To determine whether SCS reduces the susceptibility to atrial fibrillation (AF) induced by tachypacing (TP). METHODS: In 21 canines, upper thoracic SCS systems and custom cardiac pacing systems were implanted. Right atrial and left atrial effective refractory periods were measured at baseline and after 15 minutes of SCS. Following recovery in a subset of canines, pacemakers were turned on to induce AF by alternately delivering TP and searching for AF. Canines were randomized to no SCS therapy (CTL) or intermittent SCS therapy on the initiation of TP (EARLY) or after 8 weeks of TP (LATE). AF burden (percent AF relative to total sense time) and AF inducibility (percentage of TP periods resulting in AF) were monitored weekly. After 15 weeks, echocardiography and histology were performed. RESULTS: Effective refractory periods increased by 21 +/- 14 ms (P = .001) in the left atrium and 29 +/- 12 ms (P = .002) in the right atrium after acute SCS. AF burden was reduced for 11 weeks in EARLY compared with CTL (P <.05) animals. AF inducibility remained lower by week 15 in EARLY compared with CTL animals (32% +/- 10% vs 91% +/- 6%; P <.05). AF burden and inducibility were not significantly different between LATE and CTL animals. There were no structural differences among any groups. CONCLUSIONS: SCS prolonged atrial effective refractory periods and reduced AF burden and inducibility in a canine AF model induced by TP. These data suggest that SCS may represent a treatment option for AF.
PMCID:3634125
PMID: 22554859
ISSN: 1547-5271
CID: 177139

Narrow complex tachycardia with cycle length variability-what is the mechanism?

Aizer, A; Holmes, DS; Fowler, SJ; Chinitz, LA
PMID: 21684352
ISSN: 1547-5271
CID: 161151

Spinal cord stimulation protects against tachypacing-induced atrial fibrillation [Meeting Abstract]

Bernstein, S A; Wong, B; Vasquez, C; Rosenberg, S P; Rooke, R; Kuznekoff, L; Lader, J M; Mahoney, V M; Budylin, T; Alvstrand, M; Rakowski-Anderson, T; Bharmi, R; Shah, R; Fowler, S; Holmes, D; Farazi, T G; Chinitz, L A; Morley, G E
Introduction: Spinal cord stimulation (SCS) has been shown to modulate atrial electrophysiology and confer protection against ischemia and ventricular arrhythmias in animal models. We hypothesized that SCS would reduce the susceptibility to tachypacing (TP) induced atrial fibrillation (AF). Methods: In 21 canines, an upperthoracicSCS system (EonC Model 3688, Octrode Model 3186, St. Jude Medical, Piano TX) and custom cardiac pacing system (PM, Model 5386 or 2215-36, St. Jude Medical, Sylmar CA) were implanted. Atrial effective refractory periods (ERPs) in the high right atrium (RA) and distal coronary sinus (LA) were measured at baseline and after 15 min of SCS, after which AV nodal ablation was performed. Following recovery in a subset of canines, PM was turned on to create TP induced AF by alternately delivering TP and searching for AF. TP was interrupted by detection of AF and resumed after return to sinus rhythm. Upon initiation of TP, canines were randomized to no SCS therapy (CTL, n=6) or intermittent SCS therapy (SCS-ON, n=4) and followed for 15 weeks. AF burden, defined as the percent of time in AF relative to the total sense time, and AF inducibility, defined as the percent of TP periods resulting in AF induction, were monitored weekly. Data are presented as mean +/- standard error. Results: ERPs were significantly longer after SCS compared to baseline, byan average of21 +/-14ms (p=0.001) in LA and 29+/-12ms (p=0.002) in RA. The AF burden was significantly decreased by 34 percentage points at week 15in SCS-ON compared to CTL (56 +/- 21% vs 90 +/- 12%, p<0.05). AF inducibility was significantly reduced by 60 percentage points at week 15 in SCS-ON compared to CTL (32 +/- 10% vs 91 +/- 6%, p<0.05). Conclusions: SCS prolonged atrial ERPs and reduced AF burden and inducibility in a canine atrial TP induced AF model. These data suggest that SCS therapy may represent a treatment option for AF
EMBASE:70739223
ISSN: 1547-5271
CID: 166946

Contact sensing provides a highly accurate means to titrate radiofrequency ablation lesion depth

Holmes, Douglas; Fish, Jeffrey M; Byrd, Israel A; Dando, Jeremy D; Fowler, Steven J; Cao, Hong; Jensen, James A; Puryear, Harry A; Chinitz, Larry A
BACKGROUND: Transmural lesions are essential for efficacious ablation. There are, however, no accurate means to estimate lesion depth. OBJECTIVE: Explore use of the electrical coupling index (ECI) from the EnSite Contact System as a potential variable for lesion depth estimation. METHODS: Radiofrequency (RF) ablation lesions were created in atria and the thighs of swine using an irrigated RF catheter. Power was 30 W for 20 or 30 seconds intracardiac and 30-50 W for 10-60 seconds for the thigh. Intracardiac, the percentage change in ECI during ablation was compared with transmurality and collateral damage occurrence. For the thigh model, an algorithm estimating lesion depth was derived. Factors included: power, duration, and change in the ECI subcomponents (DeltaECI+) during ablation. The DeltaECI+ algorithm was compared to one using power and duration (PD) alone. RESULTS: Intracardiac, lesions with >/=12% reduction in ECI were more likely to be transmural (92.3% vs. 59.4%, P < 0.001). Twenty-second lesions were less likely to cause collateral damage compared to 30 seconds (33% vs. 70%, P = 0.003), while transmurality was similar. With the thigh model, DeltaECI+ had a better correlation than the PD algorithm (P < 0.01). Accuracy of the DeltaECI+ algorithm was unimproved with inclusion of tip orientation, while PD improved (R(2) = 0.64). DISCUSSION: Change in ECI provides evidence of transmural versus nontransmural swine intracardiac atrial lesions. A lesion depth estimation algorithm using ECI subcomponents is unaffected by tip orientation and is more accurate than using PD alone. CONCLUSION: Use of ECI as a factor in a lesion depth algorithm may provide clinically valuable information regarding the efficacy of intracardiac RF ablation lesions
PMID: 21114704
ISSN: 1540-8167
CID: 136471