Try a new search

Format these results:

Searched for:

person:kh19

Total Results:

98


Reliability of multifocal electroretinograms and Humphrey visual field thresholds in patients with retinitis pigmentosa [Meeting Abstract]

Clemens, CJ; Seiple, W; Holopigian, K; Carr, RE
ISI:000223338202276
ISSN: 0146-0404
CID: 48934

An examination of local ON- and OFF-System responses in patients with progressive cone dystrophy using long duration LED stimulation [Meeting Abstract]

Holopigian, K; Wynn, P; Clemens, CJ; Seiple, W; Carr, RE; Hood, DC
ISI:000223338202323
ISSN: 0146-0404
CID: 48935

Rod and cone photoreceptor function in patients with cone dystrophy

Holopigian, Karen; Greenstein, Vivienne C; Seiple, William; Hood, Donald C; Carr, Ronald E
PURPOSE: To determine the extent of rod and cone photoreceptor dysfunction in patients with cone dystrophy using psychophysical and electrophysiological tests. METHODS: Ten patients with cone dystrophy participated. Rod and cone system psychophysical thresholds were measured as a function of retinal eccentricity. Bright-flash full-field electroretinograms were obtained under dark-adapted (rod-mediated) and light-adapted (cone-mediated) conditions. The a-wave data were fitted with a model based on photopigment transduction to obtain values for log Rmax (maximum response) and log S (sensitivity). b-Wave parameters were also examined by fitting a nonlinear, saturating function (the Naka-Rushton equation) to the rod-mediated responses. Oscillatory potentials were measured to the cone-mediated high-intensity flashes. RESULTS: On average, the rod-mediated psychophysical thresholds were elevated by 0.5 log unit. These threshold elevations did not differ significantly with retinal eccentricity. In contrast, cone-mediated psychophysical thresholds were elevated up to 3.0 log units. Threshold elevation was greatest in the central retinal locations. For rod-mediated conditions, the a-wave Rmax parameter was significantly reduced in three patients; the a-wave log S parameter was within normal limits. The rod-mediated b-wave Rmax parameter was reduced in six patients; log k was abnormal in one patient. For cone-mediated conditions, the a-wave Rmax parameter was reduced in six patients and the a-wave log S parameter was reduced in two patients. The cone system oscillatory potentials were abnormal in nine patients. CONCLUSIONS: Patients with cone dystrophy show different patterns of psychophysical rod versus cone system sensitivity losses with retinal eccentricity. The full-field electrophysiological data indicate that most of the patients had abnormal cone photoreceptor function. Some patients also showed rod photoreceptor abnormalities. The rod system changes were smaller than the cone system changes
PMID: 14691184
ISSN: 0146-0404
CID: 42630

Electrophysiology

Holopigian, Karen; Hood, Donald C
Numerous electrophysiologic tests are available for use in the clinic. When properly recorded and analyzed, these tests provide important diagnostic and prognostic information about the site and nature of the disease process. If the results from these tests are combined with psychophysical findings (color vision, acuity, visual fields), their usefulness in defining disease can be further extended
PMID: 12809161
ISSN: 0896-1549
CID: 93711

M-versus P-function: Relationship to visual field loss in patients with open angle glaucoma [Meeting Abstract]

Badr, AA; Zemon, VM; Greenstein, VC; Clemens, CJ; Holopigian, K; Seiple, W
ISI:000184606800026
ISSN: 0146-0404
CID: 55412

Local ON and OFF system responses in patients with progressive cone dystrophy [Meeting Abstract]

Holopigian, K; Seiple, W; Clemens, CJ; Rozenbaum, I; Carr, RE
ISI:000184606800503
ISSN: 0146-0404
CID: 55417

The retinotopic distribution of localized attention assessed using the multifocal visual evoked potential [Meeting Abstract]

Kirzhner, M; Nam, JN; Clemens, CJ; Holopigian, K
ISI:000184607001590
ISSN: 0146-0404
CID: 55466

Reliability of perimetry: Measures of acuity, contrast sensitivity, and luminance detection [Meeting Abstract]

Nam, JN; Kirzhner, M; Clemens, CJ; Holopigian, K; Seiple, W
ISI:000184607002363
ISSN: 0146-0404
CID: 55467

Multifocal electroretinography as a function of age: the importance of normative values for older adults

Seiple, William; Vajaranant, Thasarat S; Szlyk, Janet P; Clemens, Colleen; Holopigian, Karen; Paliga, Jennifer; Badawi, David; Carr, Ronald E
PURPOSE: To determine the influence of age on local electroretinographic responses in humans. METHODS: Multifocal electroretinograms (mfERGs) were obtained from 62 normally sighted subjects ranging in age from 21 to 81 years. A stimulus array of 103 scaled hexagons was used to measure electrical signals within a retinal area approximately 46 degrees in diameter. Commonly reported mfERG methods were used to quantify the responses: peak-to-peak amplitudes and implicit times, scalar product amplitude, and amplitude and time scales derived from the algorithm of Hood and Li, published in 1997. RESULTS: Regression analysis showed significant linear relationships of amplitude and timing measures with age. The rates of losses were 10.5% per decade for peak-to-peak amplitude, 11.7% per decade for scalar product amplitude, and 9.5% per decade for a-scale. The rate of amplitude reduction was highest in the central 3 degrees. Age had less influence on implicit time measures. The rates of timing losses were 1.4% per decade for the N1 component and 1.0% per decade for both the P1 component and the t-scale measure. Using predicted interval ranges, the age was calculated at which 50% of the expected values would fall below the lower 95% prediction interval band of younger subjects. CONCLUSIONS: The age-associated mfERG alterations are presented to emphasize the importance of appropriate normative data in interpretation of mfERGs
PMID: 12657622
ISSN: 0146-0404
CID: 39262

The effect of variably tinted spectacle lenses on visual performance in cataract subjects

Naidu, Srilata; Lee, Jason E; Holopigian, Karen; Seiple, William H; Greenstein, Vivienne C; Stenson, Susan M
PURPOSE: A body of clinical and laboratory evidence suggests that tinted spectacle lenses may have an effect on visual performance. The aim of this study was to quantify the effects of spectacle lens tint on the visual performance of 25 subjects with cataracts. METHODS: Cataracts were scored based on best-corrected acuity and by comparison with the Lens Opacity Classification System (LOCS III) plates. Visual performance was assessed by measuring contrast sensitivity with and without glare (Morphonome software version 4.0). The effect of gray, brown, yellow, green and purple tinting was evaluated. RESULTS: All subjects demonstrated an increase in contrast thresholds under glare conditions regardless of lens tint. However, brown and yellow lens tints resulted in the least amount of contrast threshold increase. Gray lens tint resulted in the largest contrast threshold increase. CONCLUSIONS: Individuals with lenticular changes may benefit from brown or yellow spectacle lenses under glare conditions
PMID: 12769150
ISSN: 1542-2321
CID: 39215