Subcutaneous Versus Transvenous Implantable Defibrillator in Patients with Hypertrophic Cardiomyopathy

Jankelson, Lior; Garber, Leonid; Sherrid, Mark; Massera, Daniele; Jones, Paul; Barbhaiya, Chirag; Holmes, Douglas; Knotts, Robert; Bernstein, Scott; Spinelli, Michael; Park, David; Aizer, Anthony; Chinitz, Larry
BACKGROUND:Hypertrophic cardiomyopathy (HCM) is the most prevalent inherited cardiomyopathy. Implantable Cardioverter Defibrillator (ICD) is important for prevention of sudden cardiac death (SCD) in patients at high risk. In recent years the subcutaneous ICD (S-ICD) has emerged as a viable alternative to the transvenous ICD (TV-ICD). The S-ICD does not require intravascular access, but cannot provide antitachycardia pacing therapy (ATP). OBJECTIVE:To assess the real world incidence of ICD therapy in patients with HCM implanted with TV-ICD versus S-ICD. METHODS:We compared the incidence of ATP and shock therapies between all HCM patients with S-ICD and TV-ICD enrolled in the Boston Scientific ALTITUDE database. Cumulative Kaplan Meier incidence was used to compare therapy free survival and Cox proportional hazard ratios were calculated. We performed an unmatched as well as propensity match analysis. RESULTS:We included 2047 patients with TV-ICD and 626 patients with S-ICD followed for an average of 1650.5±1038.5 and 933.4±550.6 days, respectively. Patients with HCM and TV-ICD had significantly higher rate of device therapy as compared to those with S-ICD (32.7 vs. 14.5 therapies /100 patient year; p<0.001), driven by a high incidence of ATP therapy in the TV-ICD group which accounted for more than 67% of therapies delivered. Shock incidence was similar between groups, both in the general and in the matched cohorts. CONCLUSIONS:Patients with HCM and S-ICD had significantly lower therapy rate than patients with TV-ICD without difference in shock therapy, suggesting potentially unnecessary ATP therapy. Empiric ATP programing in patients with HCM may be unbeneficial.
PMID: 35038570
ISSN: 1556-3871
CID: 5131402

Repetitive nonreentrant ventriculoatrial synchrony inducing atrial fibrillation in setting of dofetilide [Case Report]

Garber, Leonid; Shulman, Eric; Kushnir, Alexander; Saraon, Tajinderpal; Park, David S; Chinitz, Larry A
PMCID:9123322
PMID: 35607350
ISSN: 2214-0271
CID: 5232852

Outcomes of posterior wall isolation with pulmonary vein isolation for paroxysmal atrial fibrillation

Jankelson, Lior; Garber, Leonid; Shulman, Eric; Cohen, Roi Bar; Peterson, Connor; Wadhwani, Lalit; Nadeau-Routhier, Charles; Xia, Yuhe; Barbhaiya, Chirag; Holmes, Douglas; Knotts, Robert; Bernstein, Scott; Kushnir, Alexander; Spinelli, Michael; Park, David; Aizer, Anthony; Chinitz, Larry
BACKGROUND:Prior studies have shown that addition of posterior wall isolation (PWI) may reduce atrial fibrillation recurrence in patients with persistent atrial fibrillation. No data on PWI in paroxysmal AF (pAF) patients with normal left atrial voltage is available, to date. OBJECTIVE:This study sought to evaluate the efficacy of PWI in addition to pulmonary vein isolation (PVI) in patients presenting with pAF and normal left atrial voltage. METHODS:Consecutive patient registry analysis was performed on all patients with pAF and normal left atrial voltage undergoing initial radiofrequency ablation from November 1, 2018 to November 15, 2019. Primary endpoint was recurrence of atrial arrhythmia including AF, atrial tachycardia (AT) or atrial flutter (AFL). RESULTS:A total of 321 patients were studied, 214 in the PVI group and 107 in the PWI+PVI group. Recurrence of any atrial arrhythmia occurred in 18.2% of patients in the PVI group and 16.8% in the PVI+PWI cohort (p=0.58). At one year, recurrence was 14.0% in the PVI group and 15.0% in the PWI+PVI group (p=0.96). There was a lower AT/AFL recurrence in the PVI+PWI group, not reaching significance (3.7% in the PWI+PVI group vs. 7.9% in PVI group, p=0.31). Need for carina lesions predicted recurrence in the PVI-only group. CONCLUSIONS:Addition of PWI to PVI in pAF patients undergoing their first ablation did not reduce the frequency of atrial arrhythmia recurrence. This warrants further study in a prospective trial. This article is protected by copyright. All rights reserved.
PMID: 34911157
ISSN: 1540-8167
CID: 5093072

Rebooting atrial fibrillation ablation in the COVID-19 pandemic

Barbhaiya, Chirag R; Wadhwani, Lalit; Manmadhan, Arun; Selim, Ahmed; Knotts, Robert J; Kushnir, Alexander; Spinelli, Michael; Jankelson, Lior; Bernstein, Scott; Park, David; Holmes, Douglas; Aizer, Anthony; Chinitz, Larry A
PURPOSE/OBJECTIVE:Catheter ablation procedures for atrial fibrillation (AF) were significantly curtailed during the peak of coronavirus disease 2019 (COVID-19) pandemic to conserve healthcare resources and limit exposure. There is little data regarding peri-procedural outcomes of medical procedures during the COVID-19 pandemic. We enacted protocols to safely reboot AF ablation while limiting healthcare resource utilization. We aimed to evaluate acute and subacute outcomes of protocols instituted for reboot of AF ablation during the COVID-19 pandemic. METHODS:Perioperative healthcare utilization and acute procedural outcomes were analyzed for consecutive patients undergoing AF ablation under COVID-19 protocols (2020 cohort; n=111) and compared to those of patients who underwent AF ablation during the same time period in 2019 (2019 cohort; n=200). Newly implemented practices included preoperative COVID-19 testing, selective transesophageal echocardiography (TEE), utilization of venous closure, and same-day discharge when clinically appropriate. RESULTS:Pre-ablation COVID-19 testing was positive in 1 of 111 patients. There were 0 cases ablation-related COVID-19 transmission and 0 major complications in either cohort. Pre-procedure TEE was performed in significantly fewer 2020 cohort patients compared to the 2019 cohort patients (68.4% vs. 97.5%, p <0.001, respectively) despite greater prevalence of persistent arrhythmia in the 2020 cohort. Same-day discharge was achieved in 68% of patients in the 2020 cohort, compared to 0% of patients in the 2019 cohort. CONCLUSIONS:Our findings demonstrate the feasibility of safe resumption of complex electrophysiology procedures during the COVID-19 pandemic, reducing healthcare utilization and maintaining quality of care. Protocols instituted may be generalizable to other types of procedures and settings.
PMID: 33543350
ISSN: 1572-8595
CID: 4776662

Time to diagnosis of acute complications after cardiovascular implantable electronic device insertion and optimal timing of discharge within the first 24 hours

Wadhwani, Lalit; Occhipinti, Karen; Selim, Ahmed; Manmadhan, Arun; Kushnir, Alexander; Barbhaiya, Chirag; Jankelson, Lior; Holmes, Douglas; Bernstein, Scott; Spinelli, Michael; Knotts, Robert; Park, David S; Chinitz, Larry A; Aizer, Anthony
BACKGROUND:More than 3 million cardiovascular implantable electronic devices (CIEDs) are implanted annually. There are minimal data regarding the timing of diagnosis of acute complications after implantation. It remains unclear whether patients can be safely discharged less than 24 hours postimplantation. OBJECTIVE:The purpose of this study was to determine the precise timing of acute complication diagnosis after CIED implantation and optimal timing for same-day discharge. METHODS:A retrospective cohort analysis of adults 18 years or older who underwent CIED implantation at a large urban quaternary care medical center between June 1, 2015, and March 30, 2020, was performed. Standard of care included overnight observation and chest radiography 6 and 24 hours postprocedure. Medical records were reviewed for the timing of diagnosis of acute complications. Acute complications included pneumothorax, hemothorax, pericardial effusion, lead dislodgment, and implant site hematoma requiring surgical intervention. RESULTS:A total of 2421 patients underwent implantation. Pericardial effusion or cardiac tamponade was diagnosed in 13 patients (0.53%), pneumothorax or hemothorax in 19 patients (0.78%), lead dislodgment in 11 patients (0.45%), and hematomas requiring surgical intervention in 5 patients (0.2%). Of the 48 acute complications, 43 (90%) occurred either within 6 hours or more than 24 hours after the procedure. Only 3 acute complications identified between 6 and 24 hours required intervention during the index hospitalization (0.12% of all cases). CONCLUSION/CONCLUSIONS:Most acute complications are diagnosed either within the first 6 hours or more than 24 hours after implantation. With rare exception, patients can be considered for discharge after 6 hours of appropriate monitoring.
PMID: 34517119
ISSN: 1556-3871
CID: 5026662

ICD shocks and complications in patients with inherited arrhythmia syndromes

Siskin, Matthew; Cerrone, Marina; Shokr, Mohamed; Aizer, Anthony; Barbhaiya, Chirag; Dai, Matthew; Bernstein, Scott; Holmes, Douglas; Knotts, Robert; Park, David S; Spinelli, Michael; Chinitz, Larry A; Jankelson, Lior
Background/UNASSIGNED:There is limited information on the long-term outcomes of ICDs in patients with inherited arrhythmia syndromes. Methods/UNASSIGNED:Prospective registry study of inherited arrhythmia patients with an ICD. Incidence of therapies and complications were measured as 5-year cumulative incidence proportions and analyzed with the Kaplan-Meier method. Incidence was compared by device indication, diagnosis type and device type. Cox-regression analysis was used to identify predictors of appropriate shock and device complication. Results/UNASSIGNED:123 patients with a mean follow up of 6.4 ± 4.8 years were included. The incidence of first appropriate shock was 56.52% vs 24.44%, p < 0.05 for cardiomyopathy and channelopathy patients, despite similar ejection fraction (61% vs 60%, p = 0.6). The incidence of first inappropriate shock was 13.46% vs 56.25%, p < 0.01 for single vs. multi-lead devices. The incidence of first lead complication was higher for multi-lead vs. single lead devices, 43.75% vs. 17.31%, p = 0.04. Patients with an ICD for secondary prevention were more likely to receive an appropriate shock than those with primary prevention indication (HR 2.21, CI 1.07-4.56, p = 0.03). Multi-lead devices were associated with higher risk of inappropriate shock (HR 3.99, CI 1.27-12.52, p = 0.02), with similar appropriate shock risk compared to single lead devices. In 26.5% of patients with dual chamber devices, atrial sensing or pacing was not utilized. Conclusion/UNASSIGNED:The rate of appropriate therapies and ICD complications in patients with inherited arrhythmia is high, particularly in cardiomyopathies with multi-lead devices. Risk-benefit ratio should be carefully considered when assessing the indication and type of device in this population.
PMCID:8569698
PMID: 34765721
ISSN: 2352-9067
CID: 5050742

Endoscopy-guided transesophageal echocardiography for large esophageal varices: Use of the "Double Barrel" technique [Case Report]

Rhee, David W; Nayar, Ambika C; Yan, Joe L; Gausman, Valerie; Park, David S; Vareedayah, Ashley A
Rhythm control strategies in patients with esophageal varices and atrial arrhythmias pose a unique challenge. The left atrium should be imaged for a thrombus prior to attempting cardioversion or ablation, but the presence of varices is a relative contraindication for transesophageal echocardiography. We present a safe, novel technique of evaluating for left atrial thrombus with simultaneous transesophageal echocardiography and esophagogastroduodenoscopy using slim probes in a patient with large, high-risk esophageal varices, and symptomatic atrial flutter with rapid ventricular rates despite medical therapy.
PMID: 34713478
ISSN: 1540-8175
CID: 5042812

Any Way You Splice It, We Need Better Risk Prediction Tools for Sudden Cardiac Death [Comment]

Park, David S
PMID: 34556283
ISSN: 2405-5018
CID: 5039432

Early onset epilepsy and sudden unexpected death in epilepsy with cardiac arrhythmia in mice carrying the early infantile epileptic encephalopathy 47 gain-of-function FHF1(FGF12) missense mutation

Velíšková, Jana; Marra, Christopher; Liu, Yue; Shekhar, Akshay; Park, David S; Iatckova, Vasilisa; Xie, Ying; Fishman, Glenn I; Velíšek, Libor; Goldfarb, Mitchell
OBJECTIVE:Fibroblast growth factor homologous factors (FHFs) are brain and cardiac sodium channel-binding proteins that modulate channel density and inactivation gating. A recurrent de novo gain-of-function missense mutation in the FHF1(FGF12) gene (p.Arg52His) is associated with early infantile epileptic encephalopathy 47 (EIEE47; Online Mendelian Inheritance in Man database 617166). To determine whether the FHF1 missense mutation is sufficient to cause EIEE and to establish an animal model for EIEE47, we sought to engineer this mutation into mice. METHODS:protein. RESULTS:mice prior to seizure. SIGNIFICANCE/CONCLUSIONS:1.6 functional axis underlying altered brain sodium channel gating in epileptic encephalopathy.
PMID: 33982289
ISSN: 1528-1167
CID: 4867612

Lesion Sequence and Catheter Spatial Stability Affect Lesion Quality Markers in Atrial Fibrillation Ablation

Jankelson, Lior; Dai, Matthew; Aizer, Anthony; Bernstein, Scott; Park, David S; Holmes, Douglas; Chinitz, Larry A; Barbhaiya, Chirag
OBJECTIVES/OBJECTIVE:This study sought to analyze high-frequency catheter excursion in relation to lesion quality markers in 20 consecutive patients undergoing first-time radiofrequency (RF) ablation for paroxysmal atrial fibrillation (AF). BACKGROUND:Ablation therapy for AF requires the delivery of durable lesions. The extent to which lesion sequence, catheter spatial stability, and anatomic location influence lesion formation during RF ablation of AF is not well understood. METHODS:Three-dimensional spatial excursion of the ablation catheter sampled at 60 Hz during pre-specified pairs of RF lesions was extracted from the CARTO3 System (Biosense Webster Inc., Irvine, California) and analyzed by using custom-developed MATLAB software (MathWorks, Natick, Massachusetts) to define precise catheter spatial stability during RF ablation. Ablation parameters including bipolar electrogram amplitude reduction, impedance decline and transmurality-associated unipolar electrogram (TUE) as evidence of lesion transmurality during lesion placement were recorded and analyzed. RESULTS:We collected 437,760 position data points during lesion placement. Ablation catheter spatial stability and lesion formation parameters varied considerably by anatomic location. Lesions placed immediately had similar bipolar electrogram amplitude reduction, smaller impedance decline, but higher likelihood of achieving TUE compared to delayed lesions. Greater catheter spatial stability correlated with lesser impedance decline. CONCLUSIONS:Lesion sequence, ablation catheter spatial stability, and anatomic location are important modifiers of RF lesion formation. Lesions placed immediately are more likely to exhibit TUE. Greater ablation catheter stability is associated with lesser impedance decline but greater likelihood of TUE.
PMID: 33516716
ISSN: 2405-5018
CID: 4775692