Deactivating cochlear implant electrodes to improve speech perception: A computational approach

Sagi, Elad; Svirsky, Mario A
A potential bottleneck to improving speech perception performance in cochlear implant (CI) users is that some of their electrodes may poorly encode speech information. Several studies have examined the effect of deactivating poorly encoding electrodes on speech perception with mixed results. Many of these studies focused on identifying poorly encoding electrodes by some measure (e.g. electrode discrimination, pitch ordering, threshold, CT-guided, masked modulation detection), but provide inconsistent criteria about which electrodes, and how many, should be deactivated, and without considering how speech information becomes distributed across the electrode array. The present simulation study addresses this issue using computational approaches. Previously validated models were used to generate predictions of speech scores as a function of all possible combinations of active electrodes in a 22-electrode array in three groups of hypothetical subjects representative of relatively better, moderate, and poorer performing CI users. Using high-performance computing, over 500 million predictions were generated. Although deactivation of the poorest encoding electrodes sometimes resulted in predicted benefit, this benefit was significantly less relative to predictions resulting from model-optimized deactivations. This trend persisted when using novel stimuli (i.e. other than those used for optimization) and when using different processing strategies. Optimum electrode deactivation patterns produced an average predicted increase in word scores of 10% with some scores increasing by more than 20%. Optimum electrode deactivation patterns typically included 11 to 19 (out of 22) active electrodes, depending on the performance group. Optimal active electrode combinations were those that maximized discrimination of speech cues, maintaining 80%-100% of the physical span of the array. The present study demonstrates the potential for further improving CI users' speech scores with appropriate selection of active electrodes.
PMID: 30396747
ISSN: 1878-5891
CID: 3455692

A potential neurophysiological correlate of electric-acoustic pitch matching in adult cochlear implant users: Pilot data

Tan, Chin-Tuan; Martin, Brett A; Svirsky, Mario A
The overall goal of this study was to identify an objective physiological correlate of electric-acoustic pitch matching in unilaterally implanted cochlear implant (CI) participants with residual hearing in the non-implanted ear. Electrical and acoustic stimuli were presented in a continuously alternating fashion across ears. The acoustic stimulus and the electrical stimulus were either matched or mismatched in pitch. Auditory evoked potentials were obtained from nine CI users. Results indicated that N1 latency was stimulus-dependent, decreasing when the acoustic frequency of the tone presented to the non-implanted ear was increased. More importantly, there was an additional decrease in N1 latency in the pitch-matched condition. These results indicate the potential utility of N1 latency as an index of pitch matching in CI users.
PMCID:6123823
PMID: 29508662
ISSN: 1754-7628
CID: 2992042

Effect of Pulse Rate on Loudness Discrimination in Cochlear Implant Users

Azadpour, Mahan; McKay, Colette M; Svirsky, Mario A
Stimulation pulse rate affects current amplitude discrimination by cochlear implant (CI) users, indicated by the evidence that the JND (just noticeable difference) in current amplitude delivered by a CI electrode becomes larger at higher pulse rates. However, it is not clearly understood whether pulse rate would affect discrimination of speech intensities presented acoustically to CI processors, or what the size of this effect might be. Intensity discrimination depends on two factors: the growth of loudness with increasing sound intensity and the loudness JND (or the just noticeable loudness increment). This study evaluated the hypothesis that stimulation pulse rate affects loudness JND. This was done by measuring current amplitude JNDs in an experiment design based on signal detection theory according to which loudness discrimination is related to internal noise (which is manifested by variability in loudness percept in response to repetitions of the same physical stimulus). Current amplitude JNDs were measured for equally loud pulse trains of 500 and 3000 pps (pulses per second) by increasing the current amplitude of the target pulse train until it was perceived just louder than a same-rate or different-rate reference pulse train. The JND measures were obtained at two presentation levels. At the louder level, the current amplitude JNDs were affected by the rate of the reference pulse train in a way that was consistent with greater noise or variability in loudness perception for the higher pulse rate. The results suggest that increasing pulse rate from 500 to 3000 pps can increase loudness JND by 60 % at the upper portion of the dynamic range. This is equivalent to a 38 % reduction in the number of discriminable steps for acoustic and speech intensities.
PMCID:5962473
PMID: 29532190
ISSN: 1438-7573
CID: 2992622

A Smartphone Application for Customized Frequency Table Selection in Cochlear Implants

Jethanamest, Daniel; Azadpour, Mahan; Zeman, Annette M; Sagi, Elad; Svirsky, Mario A
HYPOTHESIS: A novel smartphone-based software application can facilitate self-selection of frequency allocation tables (FAT) in postlingually deaf cochlear implant (CI) users. BACKGROUND: CIs use FATs to represent the tonotopic organization of a normal cochlea. Current CI fitting methods typically use a standard FAT for all patients regardless of individual differences in cochlear size and electrode location. In postlingually deaf patients, different amounts of mismatch can result between the frequency-place function they experienced when they had normal hearing and the frequency-place function that results from the standard FAT. For some CI users, an alternative FAT may enhance sound quality or speech perception. Currently, no widely available tools exist to aid real-time selection of different FATs. This study aims to develop a new smartphone tool for this purpose and to evaluate speech perception and sound quality measures in a pilot study of CI subjects using this application. METHODS: A smartphone application for a widely available mobile platform (iOS) was developed to serve as a preprocessor of auditory input to a clinical CI speech processor and enable interactive real-time selection of FATs. The application's output was validated by measuring electrodograms for various inputs. A pilot study was conducted in six CI subjects. Speech perception was evaluated using word recognition tests. RESULTS: All subjects successfully used the portable application with their clinical speech processors to experience different FATs while listening to running speech. The users were all able to select one table that they judged provided the best sound quality. All subjects chose a FAT different from the standard FAT in their everyday clinical processor. Using the smartphone application, the mean consonant-nucleus-consonant score with the default FAT selection was 28.5% (SD 16.8) and 29.5% (SD 16.4) when using a self-selected FAT. CONCLUSION: A portable smartphone application enables CI users to self-select frequency allocation tables in real time. Even though the self-selected FATs that were deemed to have better sound quality were only tested acutely (i.e., without long-term experience with them), speech perception scores were not inferior to those obtained with the clinical FATs. This software application may be a valuable tool for improving future methods of CI fitting.
PMCID:5556943
PMID: 28806335
ISSN: 1537-4505
CID: 2669212

Cochlear implants and electronic hearing

Svirsky, Mario
ISI:000407102700022
ISSN: 1945-0699
CID: 2675482

Enhancing Intervention for Residual Rhotic Errors Via App-Delivered Biofeedback: A Case Study

Byun, Tara McAllister; Campbell, Heather; Carey, Helen; Liang, Wendy; Park, Tae Hong; Svirsky, Mario
Purpose: Recent research suggests that visual-acoustic biofeedback can be an effective treatment for residual speech errors, but adoption remains limited due to barriers including high cost and lack of familiarity with the technology. This case study reports results from the first participant to complete a course of visual-acoustic biofeedback using a not-for-profit iOS app, Speech Therapist's App for /r/ Treatment. Method: App-based biofeedback treatment for rhotic misarticulation was provided in weekly 30-min sessions for 20 weeks. Within-treatment progress was documented using clinician perceptual ratings and acoustic measures. Generalization gains were assessed using acoustic measures of word probes elicited during baseline, treatment, and maintenance sessions. Results: Both clinician ratings and acoustic measures indicated that the participant significantly improved her rhotic production accuracy in trials elicited during treatment sessions. However, these gains did not transfer to generalization probes. Conclusions: This study provides a proof-of-concept demonstration that app-based biofeedback is a viable alternative to costlier dedicated systems. Generalization of gains to contexts without biofeedback remains a challenge that requires further study. App-delivered biofeedback could enable clinician-research partnerships that would strengthen the evidence base while providing enhanced treatment for children with residual rhotic errors. Supplemental Material: https://doi.org/10.23641/asha.5116318.
PMCID:5544407
PMID: 28655050
ISSN: 1558-9102
CID: 2613622

Self-Selection of Frequency Tables with Bilateral Mismatches in an Acoustic Simulation of a Cochlear Implant

Fitzgerald, Matthew B; Prosolovich, Ksenia; Tan, Chin-Tuan; Glassman, E Katelyn; Svirsky, Mario A
BACKGROUND: Many recipients of bilateral cochlear implants (CIs) may have differences in electrode insertion depth. Previous reports indicate that when a bilateral mismatch is imposed, performance on tests of speech understanding or sound localization becomes worse. If recipients of bilateral CIs cannot adjust to a difference in insertion depth, adjustments to the frequency table may be necessary to maximize bilateral performance. PURPOSE: The purpose of this study was to examine the feasibility of using real-time manipulations of the frequency table to offset any decrements in performance resulting from a bilateral mismatch. RESEARCH DESIGN: A simulation of a CI was used because it allows for explicit control of the size of a bilateral mismatch. Such control is not available with users of CIs. STUDY SAMPLE: A total of 31 normal-hearing young adults participated in this study. DATA COLLECTION AND ANALYSIS: Using a CI simulation, four bilateral mismatch conditions (0, 0.75, 1.5, and 3 mm) were created. In the left ear, the analysis filters and noise bands of the CI simulation were the same. In the right ear, the noise bands were shifted higher in frequency to simulate a bilateral mismatch. Then, listeners selected a frequency table in the right ear that was perceived as maximizing bilateral speech intelligibility. Word-recognition scores were then assessed for each bilateral mismatch condition. Listeners were tested with both a standard frequency table, which preserved a bilateral mismatch, or with their self-selected frequency table. RESULTS: Consistent with previous reports, bilateral mismatches of 1.5 and 3 mm yielded decrements in word recognition when the standard table was used in both ears. However, when listeners used the self-selected frequency table, performance was the same regardless of the size of the bilateral mismatch. CONCLUSIONS: Self-selection of a frequency table appears to be a feasible method for ameliorating the negative effects of a bilateral mismatch. These data may have implications for recipients of bilateral CIs who cannot adapt to a bilateral mismatch, because they suggest that (1) such individuals may benefit from modification of the frequency table in one ear and (2) self-selection of a "most intelligible" frequency table may be a useful tool for determining how the frequency table should be altered to optimize speech recognition.
PMCID:5563263
PMID: 28534729
ISSN: 2157-3107
CID: 2574732

Pitch Matching between Electrical Stimulation of a Cochlear Implant and Acoustic Stimuli Presented to a Contralateral Ear with Residual Hearing

Tan, Chin-Tuan; Martin, Brett; Svirsky, Mario A
BACKGROUND: Cochlear implants (CIs) successfully restore hearing in postlingually deaf adults, but in doing so impose a frequency-position function in the cochlea that may differ from the physiological one. PURPOSE: The CI-imposed frequency-position function is determined by the frequency allocation table programmed into the listener's speech processor and by the location of the electrode array along the cochlea. To what extent can postlingually deaf CI users successfully adapt to the difference between physiological and CI-imposed frequency-position functions? RESEARCH DESIGN: We attempt to answer the question by combining behavioral measures of electroacoustic pitch matching (PM) and measures of electrode location within the cochlea. STUDY SAMPLE: The participants in this study were 16 adult CI users with residual hearing who could match the pitch of acoustic pure tones presented to their unimplanted ears to the pitch resulting from stimulation of different CI electrodes. DATA COLLECTION AND ANALYSIS: We obtained data for four to eight apical electrodes from 16 participants with CIs (most of whom were long-term users), and estimated electrode insertion angle for 12 of these participants. PM functions in this group were compared with the two frequency-position functions discussed above. RESULTS: Taken together, the findings were consistent with the possibility that adaptation to the frequency-position function imposed by CIs does happen, but it is not always complete. CONCLUSIONS: Some electrodes continue to be perceived as higher pitched than the acoustic frequencies with which they are associated despite years of listening experience after cochlear implantation.
PMCID:5435235
PMID: 28277210
ISSN: 2157-3107
CID: 2476332

Contribution of formant frequency information to vowel perception in steady-state noise by cochlear implant users

Sagi, Elad; Svirsky, Mario A
Cochlear implant (CI) recipients have difficulty understanding speech in noise even at moderate signal-to-noise ratios. Knowing the mechanisms they use to understand speech in noise may facilitate the search for better speech processing algorithms. In the present study, a computational model is used to assess whether CI users' vowel identification in noise can be explained by formant frequency cues (F1 and F2). Vowel identification was tested with 12 unilateral CI users in quiet and in noise. Formant cues were measured from vowels in each condition, specific to each subject's speech processor. Noise distorted the location of vowels in the F2 vs F1 plane in comparison to quiet. The best fit model to subjects' data in quiet produced model predictions in noise that were within 8% of actual scores on average. Predictions in noise were much better when assuming that subjects used a priori knowledge regarding how formant information is degraded in noise (experiment 1). However, the model's best fit to subjects' confusion matrices in noise was worse than in quiet, suggesting that CI users utilize formant cues to identify vowels in noise, but to a different extent than how they identify vowels in quiet (experiment 2).
PMCID:5392095
PMID: 28253672
ISSN: 1520-8524
CID: 2471552

Self-Reported Usage, Functional Benefit, and Audiologic Characteristics of Cochlear Implant Patients Who Use a Contralateral Hearing Aid

Neuman, Arlene C; Waltzman, Susan B; Shapiro, William H; Neukam, Jonathan D; Zeman, Annette M; Svirsky, Mario A
Ninety-four unilateral CI patients with bimodal listening experience (CI plus HA in contralateral ear) completed a questionnaire that focused on attitudes toward hearing aid use postimplantation, patterns of usage, and perceived bimodal benefits in daily life. Eighty participants continued HA use and 14 discontinued HA use at the time of the questionnaire. Participant responses provided useful information for counseling patients both before and after implantation. The majority of continuing bimodal (CI plus HA) participants reported adapting to using both devices within 3 months and also reported that they heard better bimodally in quiet, noisy, and reverberant conditions. They also perceived benefits including improved sound quality, better music enjoyment, and sometimes a perceived sense of acoustic balance. Those who discontinued HA use found either that using the HA did not provide additional benefit over the CI alone or that using the HA degraded the signal from the CI. Because there was considerable overlap in the audiograms and in speech recognition performance in the unimplanted ear between the two groups, we recommend that unilateral CI recipients are counseled to continue to use the HA in the contralateral ear postimplantation in order to determine whether or not they receive functional or perceived benefit from using both devices together.
PMCID:5435367
PMID: 28351216
ISSN: 2331-2165
CID: 2508302