Try a new search

Format these results:

Searched for:

person:vp594

in-biosketch:true

Total Results:

49


Assessing the impact of an orientation week on acclimation to radiology residency

Prabhu, Vinay; Rispoli, Joanne M; Chhor, Chloe M; Mercado, Cecilia L; Fefferman, Nancy R
PURPOSE/OBJECTIVE:Acclimating residents to radiology residency requires attention to new responsibilities, educational material, and social cohesion. To this end, we instituted a structured orientation week for incoming residents and assessed its impact. PROCEDURES/METHODS:During the first weeks of July 2016 and 2017, first year residents attended a five day orientation free of clinical duties, consisting of didactics, hands-on training sessions, and social events. After two orientation cohorts, residents who completed orientation week, and two cohorts who had not, were given a voluntary, anonymous survey using Likert scale questions (1 [worst] to 5 [best]) regarding preparedness for responsibilities, learning, and social cohesion. Residents were asked which components were or would have been helpful. Independent samples t-tests were performed to evaluate differences between the two groups (two-tailed p < 0.05). FINDINGS/RESULTS:21/37 (57%) residents participated. Higher percentages of residents who participated in the orientation week gave scores ≥4 when asked about preparedness for rotations (70% vs. 36%), learning new material (80% vs. 36%), and class cohesiveness (90% vs. 70%). Mean scores on these questions were also higher for these residents with regards to: preparedness for new responsibilities (3.7 vs. 2.9), learning new material (3.8 vs. 2.9), and class cohesiveness (4.5 vs. 3.8), with differences approaching significance (p = 0.09-0.15). Individual components receiving most votes of ≥4 were social outings, resident lunches, didactic lectures, and PACS training. CONCLUSION/CONCLUSIONS:A weeklong orientation program free of clinical duties was valued by residents and contributed to acclimation to new responsibilities, education, and social cohesion.
PMID: 32387799
ISSN: 1873-4499
CID: 4430812

Twitter Response to the 2018 United States Preventive Services Task Force Guidelines on Prostate Cancer Screening [Letter]

Ke, Yaohan; Taylor, Jacob; Gao, Lynn Lingshan; Wang, Hezhi; Zhao, Han; Byrne, Nataliya; Modgil, Vaibhav; Butaney, Mohit; Makarov, Danil V; Prabhu, Vinay; Loeb, Stacy
Prostate cancer screening reduces advanced disease and prostate cancer death but is controversial due to downstream harms including unnecessary biopsies and overtreatment. In 2012 the United States Preventive Services Task Force (USPSTF) recommended against screening men for prostate cancer, a practice common since the early 1990's. This dramatic policy change was opposed by many physicians and patient groups. Our group reported on the Twitter response within 24 hours of these guidelines, showing a missed opportunity for greater advocacy since the majority of tweets did not express an opinion.
PMID: 30811805
ISSN: 1464-410x
CID: 3703732

Preoperative Imaging for Facial Transplant: A Guide for Radiologists

Prabhu, Vinay; Plana, Natalie M; Hagiwara, Mari; Diaz-Siso, J Rodrigo; Lui, Yvonne W; Davis, Adam J; Sliker, Clint W; Shapiro, Maksim; Moin, Adnaan S; Rodriguez, Eduardo D
Facial transplant (FT) is a viable option for patients with severe craniomaxillofacial deformities. Transplant imaging requires coordination between radiologists and surgeons and an understanding of the merits and limitations of imaging modalities. Digital subtraction angiography and CT angiography are critical to mapping vascular anatomy, while volume-rendered CT allows evaluation of osseous defects and landmarks used for surgical cutting guides. This article highlights the components of successful FT imaging at two institutions and in two index cases. A deliberate stepwise approach to performance and interpretation of preoperative FT imaging, which consists of the modalities and protocols described here, is essential to seamless integration of the multidisciplinary FT team. ©RSNA, 2019 See discussion on this article by Lincoln .
PMID: 31125293
ISSN: 1527-1323
CID: 3921042

Population net benefit of prostate MRI with high spatiotemporal resolution contrast-enhanced imaging: A decision curve analysis

Prabhu, Vinay; Rosenkrantz, Andrew B; Otazo, Ricardo; Sodickson, Daniel K; Kang, Stella K
BACKGROUND:The value of dynamic contrast-enhanced (DCE) sequences in prostate MRI compared with noncontrast MRI is controversial. PURPOSE/OBJECTIVE:To evaluate the population net benefit of risk stratification using DCE-MRI for detection of high-grade prostate cancer (HGPCA), with or without high spatiotemporal resolution DCE imaging. STUDY TYPE/METHODS:Decision curve analysis. POPULATION/METHODS:Previously published patient studies on MRI for HGPCA detection, one using DCE with golden-angle radial sparse parallel (GRASP) images and the other using standard DCE-MRI. FIELD STRENGTH/SEQUENCE/UNASSIGNED:GRASP or standard DCE-MRI at 3 T. ASSESSMENT/RESULTS:Each study reported the proportion of lesions with HGPCA in each Prostate Imaging Reporting and Data System version 2 (PI-RADS v2) category (1-5), before and after reclassification of peripheral zone lesions from PI-RADS 3-4 based on contrast-enhanced images. This additional risk stratifying information was translated to population net benefit, when biopsy was hypothetically performed for: all lesions, no lesions, PI-RADS ≥3 (using NC-MRI), and PI-RADS ≥4 on DCE. STATISTICAL TESTS/UNASSIGNED:Decision curve analysis was performed for both GRASP and standard DCE-MRI data, translating the avoidance of unnecessary biopsies and detection of HGPCA to population net benefit. We standardized net benefit values for HGPCA prevalence and graphically summarized the comparative net benefit of biopsy strategies. RESULTS:For a clinically relevant range of risk thresholds for HGPCA (>11%), GRASP DCE-MRI with biopsy of PI-RADS ≥4 lesions provided the highest net benefit, while biopsy of PI-RADS ≥3 lesions provided highest net benefit at low personal risk thresholds (2-11%). In the same range of risk thresholds using standard DCE-MRI, the optimal strategy was biopsy for all lesions (0-15% risk threshold) or PI-RADS ≥3 on NC-MRI (16-33% risk threshold). DATA CONCLUSION/UNASSIGNED:GRASP DCE-MRI may potentially enable biopsy of PI-RADS ≥4 lesions, providing relatively preserved detection of HGPCA and avoidance of unnecessary biopsies compared with biopsy of all PI-RADS ≥3 lesions. J. Magn. Reson. Imaging 2019.
PMID: 30629317
ISSN: 1522-2586
CID: 3579942

Simple preoperative radiation safety interventions significantly lower radiation doses during central venous line placement in children

Choi, Beatrix Hyemin; Yaya, Kamalou; Prabhu, Vinay; Fefferman, Nancy; Mitchell, Beverly; Kuenzler, Keith A; Ginsburg, Howard B; Fisher, Jason C; Tomita, Sandra
PURPOSE/OBJECTIVE:The purpose of this study was to reduce radiation exposure during pediatric central venous line (CVL) placement by implementing a radiation safety process including a radiation safety briefing and a job-instruction model with a preradiation time-out. METHODS:We reviewed records of all patients under 21 who underwent CVL placement in the operating room covering 22 months before the intervention through 10 months after 2013-2016. The intervention consisted of a radiation safety briefing by the surgeon to the intraoperative staff before each case and a radiation safety time-out. We measured and analyzed the dose area product (DAP), total radiation time pre- and postintervention, and the use of postprocedural chest radiograph. RESULTS:, P < 0.001) and a 73% decrease in the median radiation time (28 vs 7.6 s, P < 0.001). Additionally, there was a significant reduction in use of confirmatory CXR (95% vs 15%, P < 0.01). CONCLUSION/CONCLUSIONS:A preoperative radiation safety briefing and a radiation safety time-out supported by a job-instruction model were effective in significantly lowering the absorbed doses of radiation in children undergoing CVL insertion. TYPE OF STUDY/METHODS:Case-control study. LEVEL OF EVIDENCE/METHODS:Level III.
PMID: 30415958
ISSN: 1531-5037
CID: 3456542

Robustness of first-order texture features on 3t liver mri [Meeting Abstract]

Prabhu, V; Bruno, M; Gillingham, N; Chandarana, H
Purpose: To determine the impact of DWI and T2WI acquisition parameters on first-order hepatic texture measures at 3T MRI.
Material(s) and Method(s): Five healthy volunteers (3 M/2F, mean 40 years old) were prospectively imaged at 3T using baseline liver free-breathing DWI and T2WI acquisition twice to assess scan-rescan repeatability. Three modifications to acquisition parameters were also performed individually: decreased averages (2 vs. 4); lower resolution (DWI: 128x96 vs. 192x144 and T2WI: 192x192 vs. 320x320); and increased slice thickness (8 vs. 4 mm). A single reader placed four co-registered hepatic ROIs using 3D Slicer v4.8.1 (https://urldefense.proofpoint.com/v2/url?u=http-3A__www.slicer.org&d=DwIFAg&c=j5oPpO0eBH1iio48DtsedeElZfc04rx3ExJHeIIZuCs&r=EQR3KLkQ5UWCWWT7EfebH2P_dJeKQhvwk7yvrJe5GJY&m=VVljDEDjGLS_4z5jZ0uX9AVqXkAPM24hpGmZl06It_E&s=TQM-Y7ippXB-a-cXGwkMg-DnVAXTLHOB9hyiAIzdwXQ&e= ). 10 first-order histogram texture features (average of the four ROI) were compared to baseline acquisition. Percent difference (%diff) and coefficient of variance (CV) were computed using MedCalc.
Result(s): For ADC, 8 out of 10 parameters were repeat-able with <10% scan-rescan %diff; Skewness and Minimum were least repeatable with >10% scan-rescan %diff. Entropy was the only parameter that had < 10% CV and %diff for all acquisition schemes; all other parameters had >10% CV for at least one modified acquisition scheme. Skewness, Minimum, and Variance had the largest average CV. Change in slice thickness had the largest impact on most texture features. For T2WI, 9 out of 10 parameters were repeatable with <10% scan-rescan %diff; Skewness had >10% scan-rescan %diff. Entropy and Uniformity were the only two parameters that had <15% CV and %diff for all acquisition schemes. Change in slice thickness had the largest impact on most texture features.
Conclusion(s): ADC and T2WI first-order hepatic texture features, except for entropy, depend on acquisition parameters. Care must be taken to maintain identical acquisition schemes to compare changes in these features, such as after treatment
EMBASE:629939208
ISSN: 2366-0058
CID: 4226092

Preserved Cochlear CISS Signal is a Predictor for Hearing Preservation in Patients Treated for Vestibular Schwannoma With Stereotactic Radiosurgery

Prabhu, Vinay; Kondziolka, Douglas; Hill, Travis C; Benjamin, Carolina G; Shinseki, Matthew S; Golfinos, John G; Roland, J Thomas; Fatterpekar, Girish M
BACKGROUND:Hearing preservation is a goal for many patients with vestibular schwannoma. We examined pretreatment magnetic resonance imaging (MRI) and posttreatment hearing outcome after stereotactic radiosurgery. METHODS:From 2004 to 2014, a cohort of 125 consecutive patients with vestibular schwannoma (VS) treated via stereotactic radiosurgery (SRS) were retrospectively reviewed. MRIs containing three-dimensional constructive interference in steady state or equivalent within 1 year before treatment were classified by two radiologists for pretreatment characteristics. "Good" hearing was defined as American Academy of Otolaryngology-Head and Neck Surgery class A. Poor hearing outcome was defined as loss of good pretreatment hearing after stereotactic radiosurgery. RESULTS:Sixty-one patients met criteria for inclusion. Most had tumors in the distal internal auditory canal (55%), separated from the brainstem (63%), oval shape (64%) without cysts (86%), and median volume of 0.85 ± 0.55 cm. Pretreatment audiograms were performed a median of 108 ± 173 days before stereotactic radiosurgery; 38% had good pretreatment hearing. Smaller tumor volume (p < 0.005) was the only variable associated with good pretreatment hearing. 49 (80%) patients had posttreatment audiometry, with median follow-up of 197 ± 247 days. Asymmetrically decreased pretreatment cochlear CISS signal on the side of the VS was the only variable associated with poor hearing outcome (p = 0.001). Inter-rater agreement on cochlear three-dimensional constructive interference in steady state preservation was 91%. CONCLUSIONS:Decreased cochlear CISS signal may indicate a tumor's association with the cochlear neurovascular bundle, influencing endolymph protein concentration and creating an inability to preserve hearing. This important MRI characteristic can influence planning, counseling, and patient selection for vestibular schwannoma treatment.
PMID: 29561382
ISSN: 1537-4505
CID: 3001482

Prostate Cancer: Diffusion-weighted MR Imaging for Detection and Assessment of Aggressiveness-Comparison between Conventional and Kurtosis Models

Tamada, Tsutomu; Prabhu, Vinay; Li, Jianhong; Babb, James S; Taneja, Samir S; Rosenkrantz, Andrew B
Purpose To compare standard diffusion-weighted (DW) imaging and diffusion kurtosis (DK) imaging for prostate cancer (PC) detection and characterization in a large patient cohort, with attention to the potential added value of DK imaging. Materials and Methods This retrospective institutional review board-approved study received a waiver of informed consent. Two hundred eighty-five patients with PC underwent 3.0-T phased-array coil prostate magnetic resonance (MR) imaging, including a DK imaging sequence (b values 0, 500, 1000, 1500, and 2000 sec/mm2) before prostatectomy. Maps of apparent diffusion coefficient (ADC) and diffusional kurtosis (K) were derived by using maximal b values of 1000 and 2000 sec/mm2, respectively. Mean ADC and K were obtained from volumes of interest (VOIs) placed on each patient's dominant tumor and benign prostate tissue. Metrics were compared between benign and malignant tissue, between Gleason score (GS) /= 3 + 4 tumors, and between GS /= 4 + 3 tumors by using paired t tests, analysis of variance, receiver operating characteristic (ROC) analysis, and exact tests. Results ADC and K showed significant differences for benign versus tumor tissues, GS /= 3 + 4 tumors, and GS /= 4 + 3 tumors (P < .001 for all). ADC and K were highly correlated (r = -0.82; P < .001). Area under the ROC curve was significantly higher (P = .002) for ADC (0.921) than for K (0.902) for benign versus malignant tissue but was similar for GS /= 3 + 4 tumors (0.715-0.744) and GS /= 4 + 3 tumors (0.694-0.720) (P > .15). ADC and K were concordant for these various outcomes in 80.0%-88.6% of patients; among patients with discordant results, ADC showed better performance than K for GS /= 4 + 3 tumors (P = .016) and was similar to K for other outcomes (P > .136). Conclusion ADC and K were highly correlated, had similar diagnostic performance, and were concordant for the various outcomes in the large majority of cases. These observations did not show a clear added value of DK imaging compared with standard DW imaging for clinical PC evaluation. (c) RSNA, 2017 Online supplemental material is available for this article.
PMID: 28394755
ISSN: 1527-1315
CID: 2528142

Role of High-Resolution Dynamic Contrast-Enhanced MRI with Golden-Angle Radial Sparse Parallel Reconstruction to Identify the Normal Pituitary Gland in Patients with Macroadenomas

Sen, R; Sen, C; Pack, J; Block, K T; Golfinos, J G; Prabhu, V; Boada, F; Gonen, O; Kondziolka, D; Fatterpekar, G
BACKGROUND AND PURPOSE: Preoperative localization of the pituitary gland with imaging in patients with macroadenomas has been inadequately explored. The pituitary gland enhancing more avidly than a macroadenoma has been described in the literature. Taking advantage of this differential enhancement pattern, our aim was to evaluate the role of high-resolution dynamic MR imaging with golden-angle radial sparse parallel reconstruction in localizing the pituitary gland in patients undergoing trans-sphenoidal resection of a macroadenoma. MATERIALS AND METHODS: A retrospective study was performed in 17 patients who underwent trans-sphenoidal surgery for pituitary macroadenoma. Radial volumetric interpolated brain examination sequences with golden-angle radial sparse parallel technique were obtained. Using an ROI-based method to obtain signal-time curves and permeability measures, 3 separate readers identified the normal pituitary gland distinct from the macroadenoma. The readers' localizations were then compared with the intraoperative location of the gland. Statistical analyses were performed to assess the interobserver agreement and correlation with operative findings. RESULTS: The normal pituitary gland was found to have steeper enhancement-time curves as well as higher peak enhancement values compared with the macroadenoma (P < .001). Interobserver agreement was almost perfect in all 3 planes (kappa = 0.89). In the 14 cases in which the gland was clearly identified intraoperatively, the correlation between the readers' localization and the true location derived from surgery was also nearly perfect (kappa = 0.95). CONCLUSIONS: This study confirms our ability to consistently and accurately identify the normal pituitary gland in patients with macroadenomas with the golden-angle radial sparse parallel technique with quantitative permeability measurements and enhancement-time curves.
PMCID:6080601
PMID: 28495945
ISSN: 1936-959x
CID: 2548692

Using Twitter to Assess the Public Response to the United States Preventive Services Task Force Guidelines on Lung Cancer Screening with Low Dose Chest CT

Khasnavis, Siddharth; Rosenkrantz, Andrew B; Prabhu, Vinay
To use Twitter to assess the immediate public response to the United States Preventive Services Task Force (USPSTF) 2013 draft guidelines on lung cancer screening with low-dose chest CT (LDCT). The number of tweets including the phrases "lung cancer screening," "lung CT," "chest CT," "low dose computed tomography," "low dose CT," or "LDCT" was recorded for 6 days before and after guidelines release. A systematic sample of 172 tweets from the week following release was coded for user type, tweet opinion, linked article source, and article opinion. Following guidelines' release, the number of daily tweets increased from 13 +/- 8 to 311 +/- 395. The 172 tweets in the week following release were tweeted by 166 unique users including: news organizations/online news gathering accounts (34.9%), general public (21.7%), physicians (12.0%, 6 radiologists), and businesses (11.4%). 23.3% of tweets provided opinion on the guidelines (50.0% favorable, 27.5% concerned toward screening). Most (91.3%) tweets contained links to a total of 46 unique articles, which were authored by lay press (41.3%), non-peer-reviewed medical press (32.6%), and hospital/medical practice websites (10.9%). Among these, 50.0% were favorable, citing mortality reduction (87.0%), published data supporting screening (50.0%), and early detection (43.5%), while 28.3% expressed concern, including false positives (58.9%) and radiation risk (39.1%). Twitter activity rose rapidly after the USPSTF draft guidelines on LDCT. Most users were non-physicians and frequently cited non-peer-reviewed articles. Users maintained an overall favorable view of screening, while expressing various concerns. Considerable opportunity exists for greater radiologist engagement in this online public dialog.
PMCID:5422226
PMID: 28091834
ISSN: 1618-727x
CID: 2413742