Try a new search

Format these results:

Searched for:

person:appler01

Total Results:

60


Comparison of image quality between a narrow caliber transesophageal echocardiographic probe and the standard size probe during intraoperative evaluation

Reynolds, Harmony R; Spevack, Daniel M; Shah, Alan; Applebaum, Robert M; Kanchuger, Mark; Tunick, Paul A; Kronzon, Itzhak
BACKGROUND: Transesophageal echocardiography (TEE) has become an integral part of the evaluation and monitoring of patients during cardiac operation. Until recently, the smallest TEE probe with multiplane imaging measured 13 mm in diameter. This size is now standard for adult TEE probes. Recently, a new TEE probe has become available (MiniMulti TEE probe, Philips Medical Systems, Andover, Mass), which has a diameter of 8 mm. Although using a smaller probe is attractive, the quality of images it generates when used in adults has not yet been examined. OBJECTIVE: The purpose of this study was to compare TEE studies done with both probes. METHODS: After informed consent was obtained, full intraoperative TEE studies were performed in 20 patients with a small pediatric probe. The study was then repeated using a standard adult probe. The studies were read in random order by two experienced echocardiographers blinded to probe used. For each study, 18 anatomic cardiac structures and 5 Doppler patterns were subjectively graded as excellent (1), good (2), fair (3), or poor (4) in quality. The average score for each structure or Doppler profile was computed for each probe. RESULTS: The average score for all findings was lower (better) for the adult TEE probe (1.4 +/- 0.4 vs 1.7 +/- 0.4; P =.003). When each finding was compared separately, several cardiac structures (left ventricle [LV], pericardium, right ventricle [RV], interatrial septum, left atrium, left atrial appendage, mitral valve, aortic valve) had better scores with the adult probe, and the differences for the LV and RV were larger than those for the other findings (LV scores differed by 0.7, P =.0004; RV scores differed by 0.5, P =.01). There was no significant difference between probes when evaluating venous structures (coronary sinus, superior vena cava, pulmonary vein), the thoracic aorta, or the right atrium or tricuspid valve. In addition, Doppler patterns were not significantly different with the two probes. There were two findings that were missed with the small probe and seen with the adult probe (one aortic plaque and one left atrial appendage thrombus). CONCLUSIONS: In the adult, the larger probe provides better images, particularly of the RV and LV. In addition, important findings may be missed with the smaller probe. However, if the adult probe cannot be passed, the pediatric probe is a reasonable alternative
PMID: 15452470
ISSN: 0894-7317
CID: 45390

Revascularization alone for functional mitral regurgitation: A propensity case-match analysis of the off pump coronary artery bypass approach [Meeting Abstract]

Saunders, PC; Grossi, EA; Schwartz, CF; Applebaum, RM; Ribakove, GH; Culliford, AT; Galloway, AC; Colvin, SB
ISI:000189388501166
ISSN: 0735-1097
CID: 42552

Comparison of a small (pediatric) transesophageal echocardiography probe with a standard (adult) probe [Meeting Abstract]

Reynolds, HR; Spevack, DM; Shah, A; Applebaum, RM; Kanchuger, M; Tunick, PA; Kronzon, I
ISI:000189388501483
ISSN: 0735-1097
CID: 42452

Propensity case-matched analysis of off-pump coronary artery bypass grafting in patients with atheromatous aortic disease

Sharony, Ram; Grossi, Eugene A; Saunders, Paul C; Galloway, Aubrey C; Applebaum, Robert; Ribakove, Greg H; Culliford, Alfred T; Kanchuger, Marc; Kronzon, Itzhak; Colvin, Stephen B
OBJECTIVE: Atheromatous aortic disease is a risk factor for excessive mortality and stroke in patients undergoing coronary artery bypass grafting. Outcomes of off-pump coronary artery bypass grafting and coronary artery bypass grafting with cardiopulmonary bypass in patients with severe atheromatous aortic disease were compared by propensity case-match methods. METHODS: Routine intraoperative transesophageal echocardiography identified 985 patients undergoing isolated coronary artery bypass grafting with severe atheromatous disease in the aortic arch or ascending aorta. Off-pump coronary artery bypass grafting was performed in 281 patients (28.5%). Propensity matched-pairs analysis was used to match patients undergoing off-pump coronary artery bypass grafting (n = 245) with patients undergoing coronary artery bypass grafting with cardiopulmonary bypass. RESULTS: Univariate analysis revealed decreased hospital mortality (16/245, 6.5% vs 28/245, 11.4%; P =.058) and stroke prevalence (4/245, 1.6% vs 14/245, 5.7%; P =.03) in off-pump coronary artery bypass grafting compared with coronary artery bypass grafting with cardiopulmonary bypass. Freedom from any postoperative complication was higher in off-pump coronary artery bypass grafting compared with coronary artery bypass grafting with cardiopulmonary bypass (226/245, 92.2% vs 196/245, 80.0%; P <.001). Multivariable analysis of preoperative risk factors showed that increased hospital mortality was associated with coronary artery bypass grafting with cardiopulmonary bypass (odds ratio = 2.7; P =.01), fewer grafts (P =.05), acute myocardial infarction (odds ratio = 11.5; P <.001), chronic obstructive pulmonary disease (odds ratio = 2.4; P =.03), previous cardiac surgery (odds ratio = 10.2, P =.05), and peripheral vascular disease (odds ratio = 2.1; P =.05). Cardiopulmonary bypass was the only independent risk factor for stroke (odds ratio = 3.6, P =.03). At 36 months' follow-up, comparable survival was observed in the off-pump coronary artery bypass grafting and coronary artery bypass grafting with cardiopulmonary bypass groups (74% vs 72%). Multivariable analysis revealed that renal disease (P <.001), advanced age (P <.001), previous myocardial infarction (P =.03), and lower number of grafts (P =.02) were independent risks for late mortality. CONCLUSIONS: Patients with severe atherosclerotic aortic disease who undergo off-pump coronary artery bypass grafting have a significantly lower prevalence of hospital mortality, perioperative stroke, and overall complications than matched patients who underwent coronary artery bypass grafting with cardiopulmonary bypass. Routine intraoperative transesophageal echocardiography identifies severe atheromatous aortic disease and directs the choice of surgical technique
PMID: 14762348
ISSN: 0022-5223
CID: 42050

Semirigid partial annuloplasty band allows dynamic mitral annular motion and minimizes valvular gradients: an echocardiographic study

Sharony, Ram; Saunders, Paul C; Nayar, Ambika; McAleer, Eileen; Galloway, Aubrey C; Delianides, Julie; Schwartz, Charles F; Applebaum, Robert M; Kronzon, Itzhak; Colvin, Stephen B; Grossi, Eugene A
BACKGROUND: Traditional mitral annuloplasty devices include both rigid rings, which restrict annular motion, and soft rings and bands, which can locally deform. Conflicting data exist regarding their impact on annular dynamics. We studied mitral annuloplasty with a semirigid partial band and with a nearly complete rigid ring. METHODS: Intraoperative three-dimensional transesophageal echocardiograms (n = 14) and predischarge transthoracic echocardiograms were retrospectively analyzed in patients undergoing mitral valve repair for degenerative disease with either a rigid ring (n = 77) or a semirigid partial band (n = 38). Each transesophageal echocardiogram was analyzed with TomTec three-dimensional software to produce cardiac cycle frame planimetry and to measure device geometry. Actual device sizes provided reference dimensions. Blinded analysis of Doppler data from transthoracic echocardiograms was performed. RESULTS: Validation of the quantitative transesophageal echocardiogram methodology revealed a 1.3% +/- 0.3% (mean +/- standard error of the mean) underestimation of actual linear dimension. With the semirigid partial band, systolic valve orifice area and intertrigonal distance decreased from 6.14 +/- 0.37 to 5.55 +/- 0.24 cm(2) (-9.6%; p = 0.01) and from 2.69 +/- 0.08 to 2.55 +/- 0.13 cm (-5.2%; p = 0.03), respectively. Systolic anterior-posterior distance decreased from 2.1 +/- 0.10 to 1.95 +/- 0.06 cm (-7.1%; p = 0.01) compared with diastole. In contrast, rigid ring orifice area was unchanged (4.12 +/- 0.15 to 4.10 +/- 0.16 cm(2); -0.5%; p = 0.48) during the cardiac cycle. Transthoracic echocardiography revealed significantly lower mitral inflow gradients with semirigid partial band (mean gradients compared with rigid ring, 4.0 +/- 0.3 versus 5.0 +/- 0.3 mm Hg; p = 0.02; peak gradients, 8.9 +/- 0.5 versus 11.1 +/- 0.5 mm Hg; p = 0.01). CONCLUSIONS: Three-dimensional transesophageal echocardiographic measurements of annular dynamics are valid and reliable when discrete annuloplasty devices are present. In contrast to the rigid ring, the semirigid partial band permits more physiologic geometric changes and is associated with lower postoperative mitral valve gradients
PMID: 14759429
ISSN: 0003-4975
CID: 42597

Anterior leaflet resection of the mitral valve

Saunders, Paul C; Grossi, Eugene A; Schwartz, Charles F; Grau, Juan B; Ribakove, Greg H; Culliford, Alfred T; Applebaum, Robert M; Galloway, Aubrey C; Colvin, Steven B
Triangular resection is a reconstructive option for treatment of anterior leaflet mitral disease with segmental prolapse. In our experience, it is a safe and reproducible technique, associated with low rates of recurrent MR or need for reoperation, as well as decreased likelihood for systolic anterior motion after mitral repair. We review our experience with this technique over a 25-year experience with mitral valve reconstruction
PMID: 15197696
ISSN: 1043-0679
CID: 45685

Substernal epicardial echocardiography: review of a new technique [Case Report]

Reynolds, Harmony R; Nayar, Ambika C; McAleer, Eileen P; Schwartz, Jesse D; Tunick, Paul A; Applebaum, Robert M; Colvin, Stephen B; Culliford, Alfred T; Galloway, Aubrey C; Grossi, Eugene A; Ribakove, Gregory H; Kronzon, Itzhak
BACKGROUND: Patients after cardiac operation pose a challenge to the treating physician-these patients may become critically ill and are among the most difficult to image using transthoracic echocardiography. Several factors contribute to this, including difficulties in positioning the patient, inability of the patient to cooperate with instructions, surgical dressings, and hyperinflated lungs. Transesophageal echocardiography may be performed when transthoracic echocardiography is not diagnostic; however, transesophageal echocardiography is semi-invasive and does not lend itself to prolonged or repeated monitoring. METHODS: Recently, a new approach to echocardiography for use in the patient after operation has been introduced with the modification of the standard mediastinal drainage tube to allow for substernal epicardial echocardiography (SEE). The SEE tube has 2 lumens. The first allows for routine mediastinal drainage and the second has a blind end that permits the insertion of a standard transesophageal echocardiographic probe for high-resolution imaging as often as is desired over the period during which the mediastinal tube is in place. CONCLUSION: This article reviews the technique of SEE including a description of the method of performance of SEE (with representative images), a review of the published literature on this new modality, examples of clinical use, and a discussion of the advantages, indications, and limitations of SEE with an eye toward future directions for research
PMID: 14608297
ISSN: 0894-7317
CID: 42051

Off-pump coronary artery bypass grafting reduces mortality and stroke in patients with atheromatous aortas: a case control study

Sharony, Ram; Bizekis, Costas S; Kanchuger, Marc; Galloway, Aubrey C; Saunders, Paul C; Applebaum, Robert; Schwartz, Charles F; Ribakove, Greg H; Culliford, Alfred T; Baumann, F Gregory; Kronzon, Itzhak; Colvin, Stephen B; Grossi, Eugene A
BACKGROUND: Patients with severe atheromatous aortic disease (AAD) who undergo coronary artery bypass (CABG) have an increased risk of death and stroke. We hypothesized that in these high risk patients, off-pump coronary artery bypass (OPCAB) technique is associated with lower morbidity and mortality. METHODS AND RESULTS: Between June 1993 and January 2002, 5737 patients undergoing CABG had routine intra-operative TEE with 913 (15.9%) found to have severe AAD in the aortic arch or ascending aorta. Of these, 211 patients who underwent OPCAB were matched with 211 on-pump CABG patients by age, ejection fraction, history of stroke, cerebrovascular disease, diabetes, renal disease, nonelective operation, and previous cardiac surgery. Hospital mortality was 11.4% (24/211) for on-pump CABG and 3.8% (8/211) for OPCAB (P=0.003). Multivariate analysis revealed that increased mortality was associated with on-pump CABG (P=0.001), acute MI (P=0.03), number of grafts (P=0.01), age (P=0.01), history of stroke or cerebrovascular disease (P=0.04), CHF (P=0.02), and peripheral vascular disease (P=0.03). Multivariate analysis showed that OPCAB technique was associated with decreased stroke (P=0.05). Freedom from any complication was 78.7% for on-pump CABG and 91.9% for OPCAB (P<0.001). At 36 month follow-up multivariate analysis revealed that increased mortality was associated with age (P=0.001), previous MI (P=0.03), and renal disease (P=0.04), whereas increased survival was associated with increased number of grafts (P=0.001) and OPCAB (P=0.01). CONCLUSIONS: OPCAB surgery in patients with severe AAD is associated with lower risk of death, stroke and complications and improved mid-term survival. Routine intra-operative TEE allows identification of these patients and directs choice of appropriate surgical technique
PMID: 12970201
ISSN: 1524-4539
CID: 39076

Routine intraoperative transesophageal echocardiography identifies patients with atheromatous aortas: Impact on "off-pump" coronary artery bypass and perioperative stroke

Grossi, Eugene A; Bizekis, Costas S; Sharony, Ram; Saunders, Paul C; Galloway, Aubrey C; Lapietra, Angelo; Applebaum, Robert M; Esposito, Rick A; Ribakove, Greg H; Culliford, Alfred T; Kanchuger, Marc; Kronzon, Itzhak; Colvin, Stephen B
BACKGROUND: Patients with severe atheromatous aortic disease (AAD) undergoing coronary artery bypass grafting (CABG) have increased operative risks. The 'off-pump' CABG (OPCAB) technique was evaluated in patients given the diagnosis of severe AAD by routine transesophageal echocardiography. METHODS: A total of 5737 patients underwent CABG, with 913 having transesophageal echocardiography findings of severe AAD. Of the patients with severe AAD, 678 (74.3%) had conventional CABG and 235 (25.7%) had OPCAB. RESULTS: Hospital mortality was 8.7% for conventional CABG and 5.1% for OPCAB (P =.08). Multivariate analysis revealed that increased mortality was significantly associated with acute myocardial infarction, conventional CABG, age, renal disease, history of stroke, and ejection fraction < 30%. Neurologic complications occurred in 6.3% of patients undergoing CABG and in 2.1% undergoing OPCAB (P =.01). Freedom from any complication was significantly greater with OPCAB. CONCLUSION: Routine intraoperative transesophageal echocardiography identifies patients with severe AAD. In these patients, OPCAB technique is associated with a lower risk of death, stroke, and all complications
PMID: 12835662
ISSN: 0894-7317
CID: 36724

Aortic valve replacement in patients with impaired ventricular function

Sharony, Ram; Grossi, Eugene A; Saunders, Paul C; Schwartz, Charles F; Ciuffo, Giovanni B; Baumann, F Gregory; Delianides, Julie; Applebaum, Robert M; Ribakove, Greg H; Culliford, Alfred T; Galloway, Aubrey C; Colvin, Stephen B
BACKGROUND: Patients with reduced ventricular function undergoing aortic valve replacement have increased operative risks, but the impact of valvular pathophysiology and other risk factors has not been clearly defined. METHODS: From June 1992 through June 2002, 1,402 consecutive patients underwent isolated aortic valve surgery with or without coronary artery bypass grafting; of these patients, 416 had an ejection fraction less than 40% and are the subject of this report. These patients (mean age, 68.6) had severe stenosis (62.5%), severe regurgitation (30.3%), or mixed disease (7.2%). Aortic valve replacement plus coronary artery bypass grafting was performed in 48.4% of patients, and 27% had previous cardiac surgery. Follow-up included echocardiography and survival analysis. RESULTS: Hospital mortality was 10.1% (42 of 416), with no difference between aortic stenosis (9.6%) and regurgitation (11.1%). Multivariate analysis revealed that age (p = 0.002) and renal disease (odds ratio = 4.2; 95% confidence interval, 1.9 to 9.3; p = 0.001) were independently associated predictors of mortality. Valvular pathophysiology had no impact on mortality. Peripheral vascular disease, multivessel coronary disease, and renal disease were associated risks for any postoperative complication. Peripheral vascular disease (odds ratio = 12.3, p = 0.02), history of cerebrovascular disease (odds ratio = 4.8, p = 0.038), and diabetes (odds ratio = 2.7, p = 0.04) were associated risks for stroke. The ejection fraction was more than 40% in 52% of the patients who had postoperative echocardiography (mean follow-up, 6 months). Actuarial survival revealed no difference between pathophysiologic groups. CONCLUSIONS: Aortic valve surgery in patients with impaired ventricular function carries an acceptable operative risk that can be stratified by age and comorbidities. The type of valvular pathophysiology does not significantly affect mortality
PMID: 12822620
ISSN: 0003-4975
CID: 36725