Searched for: in-biosketch:true
person:dj365
Image Quality Improvement in MRI of Cochlear Implants and Auditory Brainstem Implants After Metal Artifact Reduction Techniques
Winchester, Arianna; Cottrell, Justin; Kay-Rivest, Emily; Friedmann, David; McMenomey, Sean; Thomas Roland, J; Bruno, Mary; Hagiwara, Mari; Moonis, Gul; Jethanamest, Daniel
OBJECTIVE:Observe if metal artifact reduction (MAR) techniques applied to magnetic resonance imaging (MRI) performed on patients with cochlear implants (CI) or auditory brainstem implants (ABI) improves image quality. STUDY DESIGN/METHODS:Retrospective review. SETTING/METHODS:Tertiary care center. PATIENTS/METHODS:Patients with auditory implants who underwent clinical MRI before and after the application of MAR techniques previously described. INTERVENTIONS/METHODS:From September 2022 to March 2023, patients who underwent brain or internal auditory canal (IAC) MRI with and without MAR were identified. Sequences included T1 and T2 weighted with turbo-spin-echo (TSE) correction and fluid-attenuation inversion recovery (FLAIR). Images were analyzed for visualization of intracranial structures by two neuroradiologists. MAIN OUTCOME MEASURES/METHODS:Visibility of 14 structures graded on a four-point Likert scale. Average scores per structure and sequence were compared using paired two-tailed t-tests and change in mode score. RESULTS:Ten patients underwent pre- and post-MAR MRI. Six had a unilateral CI, three had a unilateral ABI, and one had an ABI and CI. Three patients had four devices with the internal magnet removed for both scans. All structures had significantly improved visibility on post-MAR scan except ipsilateral parietal and occipital lobes and contralateral inner ear. Mode score increased from 2 to 4 for the ipsilateral occipital lobe and from 3 to 4 for the ipsilateral semicircular canals, brainstem, and cerebellar peduncles. Significant improvement was seen in all sequences except for ipsilateral structures on T1w axial precontrast and contralateral structures on T1w coronal postcontrast. ABIs did not improve as much as CIs because they scored better on the pre-MAR scan. CONCLUSIONS:MAR techniques improve image quality for patients with MRI-compatible implants with magnets. Benefits may be more evident in CIs than ABIs.
PMID: 40307987
ISSN: 1537-4505
CID: 5833932
Hearing Preservation and Functional Outcomes After Resection of Epidermoid Lesions of the Cerebellopontine Angle With High Hearing Risk
Papazian, Michael; Cottrell, Justin; Yang, Jackie; Kay-Rivest, Emily; Friedmann, David R; Jethanamest, Daniel; Kondziolka, Douglas; Pacione, Donato; Sen, Chandranath; Golfinos, John G; Thomas Roland, J; McMenomey, Sean O
OBJECTIVES/OBJECTIVE:To assess a decade of experience of treating patients with high hearing risk cerebellopontine angle (CPA) epidermoid lesions and examine factors influencing postoperative outcomes, particularly hearing preservation. STUDY DESIGN/METHODS:Retrospective chart review. SETTING/METHODS:Single tertiary-referral center. PATIENTS/METHODS:Adults with CPA epidermoid lesions who presented with hearing loss or evidence of lesion involving vestibulocochlear nerve. INTERVENTIONS/METHODS:The studied intervention was microsurgical resection. MAIN OUTCOME MEASURES/METHODS:Main outcome measures included extent of resection, hearing preservation rate for patients with postoperative audiograms, and disease progression. RESULTS:Twenty-three adults with an average tumor volume of 15.63 ± 16.2 cm3 were included. Five lesions (22%) involved the full internal auditory canal (IAC), 11 (48%) had partial involvement, and 5 (22%) were IAC sparing. Most patients with IAC involvement (88%) had circumferential invasion of the canal. Patients underwent either a retrosigmoid (18, 79%) or combined retrolabyrinthine transpetrosal approach (5, 22%), and gross total resection was achieved in most cases (13, 57%). Of 12 patients with postoperative audiograms, 10 (83%) had preoperative hearing preserved. There was no statistically significant change in hearing scores with treatment based on preoperative extent of IAC involvement. Ten patients (43%) had residual lesions postoperatively, and 6 exhibited progression. One patient ultimately required reoperation 6 years after initial surgery. CONCLUSIONS:Preoperative hearing was preserved in the majority of the patients who underwent resection of CPA epidermoids via a retrosigmoid or transpetrosal approach. CPA epidermoids often invaded the IAC; however, degree of invasion was not associated with hearing outcomes.
PMID: 39951666
ISSN: 1537-4505
CID: 5793992
Performance After Cochlear Reimplantation Using a Different Manufacturer
Cottrell, Justin; Spitzer, Emily; Winchester, Arianna; Dunn-Johnson, Camille; Gantz, Bruce; Rathgeb, Susan; Shew, Matthew; Herzog, Jacques; Buchman, Craig; Friedmann, David; Jethanamest, Daniel; McMenomey, Sean; Waltzman, Susan; Thomas Roland, J
OBJECTIVE:To better understand cochlear implant (CI) performance after reimplantation with a different device manufacturer. STUDY DESIGN/METHODS:Multisite retrospective review. SETTING/METHODS:Tertiary referral centers. PATIENTS/METHODS:Patients older than 4 years who received a CI and subsequently underwent CI reimplantation with a different manufacturer over a 20-year period. INTERVENTION/METHODS:Reimplantation. MAIN OUTCOME MEASURE/METHODS:The primary outcome was difference in the best CNC score obtained with the primary CI, compared with the most recent CNC score obtained after reimplantation. RESULTS:Twenty-nine patients met the criteria at three centers. The best average CNC score achieved by adult patients after primary cochlear implantation was 46.2% (n = 16), measured an average of 14 months (range: 3-36 mo) postoperatively. When looking at the most recent CNC score of adult patients before undergoing reimplantation, the average CNC score dropped to 19.2% (n = 17). After reimplantation, the average 3- to 6-month CNC score was 48.3% (n = 12), with most recent average CNC score being 44.4% (n = 17) measured an average of 19 months (range: 3-46 mo) postoperatively. There was no statistically significant difference (p = 0.321; t11 = 0.48) identified in performance between the best CNC score achieved by adult patients after primary cochlear implantation, and the most recent score achieved after reimplantation (n = 12). Analysis of prerevision and postrevision speech performance was not possible in pediatric patients (<18 yr old) because of differences in tests administered. CONCLUSION/CONCLUSIONS:Patients undergoing reimplantation with a different manufacturer achieved CNC score performance comparable to their best performance with their original device.
PMID: 39264919
ISSN: 1537-4505
CID: 5690552
Characterizing Cochlear Implant Trans-Impedance Matrix Heatmaps in Patients With Abnormal Anatomy
Cottrell, Justin; Winchester, Arianna; Friedmann, David; Jethanamest, Daniel; Spitzer, Emily; Svirsky, Mario; Waltzman, Susan B; Shapiro, William H; McMenomey, Sean; Roland, J Thomas
OBJECTIVE:To characterize transimpedance matrix (TIM) heatmap patterns in patients at risk of labyrinthine abnormality to better understand accuracy and possible TIM limitations. STUDY DESIGN/METHODS:Retrospective review of TIM patterns, preoperative, and postoperative imaging. SETTING/METHODS:Tertiary referral center. PATIENTS/METHODS:Patients undergoing cochlear implantation with risk of labyrinthine abnormality. INTERVENTION/METHODS:None. RESULTS:Seventy-seven patients were evaluated. Twenty-five percent (n = 19) of patients had a TIM pattern variant identified. These variants were separated into 10 novel categories. Overall, 9% (n = 6) of electrodes were malpositioned on intraoperative x-ray, of which 50% (n = 3) were underinserted, 17% (n = 1) were overinserted, 17% (n = 1) had a tip foldover, and 17% (n = 1) had a coiled electrode. The number of patients with a variant TIM pattern and normal x-ray was 18% (n = 14), and the number of patients with normal TIM pattern and malposition noted on x-ray was 3% (n = 2; both were electrode underinsertions that were recognized due to open circuits and surgical visualization).A newly defined skip heat pattern was identified in patients with IP2/Mondini malformation and interscalar septum width <0.5 mm at the cochlear pars ascendens of the basal turn. CONCLUSIONS:This study defines novel patterns for TIM heatmap characterization to facilitate collaborative and comparative research moving forward. In doing so, it highlights a new pattern termed skip heat, which corresponds with a deficient interscalar septum of the cochlea pars ascendens of the basal turn in patients with IP2 malformation. Overall, the data assist the surgeon in better understanding the implications and limitations of TIM patterns within groups of patients with risk of labyrinthine abnormalities.
PMID: 39190800
ISSN: 1537-4505
CID: 5689822
Cochlear Apex Triangulation Utilizing Ct Measures And Middle Ear Landmarks
Cottrell, Justin; Landsberger, David; Breen, Matt; Lebowitz, Joseph; Hagiwara, Mari; Moonis, Gul; Shapiro, William; Friedmann, David R; Jethanamest, Daniel; McMenomey, Sean; Roland, J Thomas
OBJECTIVE/UNASSIGNED:To better characterize the cochlear apex in relation to surgically relevant landmarks to guide surgeons and improve procedural success of apical electrode placement. STUDY DESIGN/UNASSIGNED:Retrospective image analysis. SETTING/UNASSIGNED:Tertiary referral center. PATIENTS/UNASSIGNED:Cochlear implant recipients with available preoperative computed tomography (CT) imaging. INTERVENTION/UNASSIGNED:None. MAIN OUTCOME MEASURE/UNASSIGNED:Cochlear dimensions and cochlear apex distance measures to surgically relevant middle ear landmarks and critical structures. RESULTS/UNASSIGNED:Eighty-two temporal bone CT scans were analyzed utilizing multiplanar reformats. The average lateral width of promontory bone over the cochlear apex was 1.2 mm (standard deviation [SD], 0.3). The anteroposterior distance from the round window (avg, 4.2 mm; SD, 0.5), oval window (avg, 3.3 mm; SD, 0.3), cochleariform process (avg, 2.3; SD, 0.5), and superior-inferior distance from the cochleariform process (avg, -0.9; SD, 0.8) to the cochlear apex were measured. The relationship of the cochlear apex to critical structures was highly variable.A newly developed stapes vector was created and found to mark the posterior/superior boundary of the apex in 94% of patients. When a vector parallel to the stapes vector was drawn through the round window, it marked the anterior/inferior boundary of the cochlear apex in 89% of patients. CONCLUSIONS/UNASSIGNED:This study assists in characterizing cochlear apex anatomy and its relation to surrounding structures as a means of improving procedural accuracy and reducing trauma during apical cochleostomy. Understanding both distance relationships and expected boundaries of the apex could help to inform future surgical approaches.
PMCID:11424059
PMID: 39328867
ISSN: 2766-3604
CID: 5803062
Patient Characteristics Impacting Adherence to Serial Observation for Vestibular Schwannomas
Wang, Ronald S; Asfour, Leena; Yang, Wenqing; Zhang, Yan; Santacatterina, Michele; Jethanamest, Daniel
OBJECTIVE:To examine patient characteristics that impact serial observation adherence among vestibular schwannoma (VS) patients. STUDY DESIGN/METHODS:Retrospective chart review. SETTING/METHODS:Single tertiary care center. METHODS:We selected for VS patients from 201 to 2020 who elected for serial observation as initial management. Patients under 18, with previous management, bilateral or intralabyrinthine VS, and neurofibromatosis type 2 were excluded. Demographics, tumor characteristics, and follow-up status were extracted. Single and multiple logistic regression was used to identify patient characteristics impacting follow-up. RESULTS:We identified 507 VS patients who chose serial observation as initial management. Most were female (56.0%), white (73.0%), and married (72.8%). The mean age was 59.3 and most had private insurance (56.4%). Median Charlson Comorbidity Index was 2.00. Mean pure tone audiometry (PTA) average was 41.7 Hz. Average tumor size was 9.04 mm. Of 507 patients, 358 (70.6%) returned for at least one follow-up. On multiple logistic regression analysis, patients with private insurance (odds ratio [OR]: 0.39, confidence interval [CI]: 0.22-0.68; P = .001), racial minority background (OR: 0.54, CI: 0.35-0.83; P = .005), worse PTA averages (OR: 0.99, CI: 0.98-1.00; P = .044), and older age at diagnosis (OR: 0.97, CI: 0.95-1.00; P = .038) were less likely to follow-up. CONCLUSION/CONCLUSIONS:Private health insurance, racial minority background, worse PTA average, and older age were associated with decreased follow-up among adult VS patients electing serial observation. Patients with these characteristics may require additional support to ensure serial observation adherence.
PMID: 38520200
ISSN: 1097-6817
CID: 5641062
Cochlear Implantation in Children Under 9 Months of Age: Safety and Efficacy
Cottrell, Justin; Spitzer, Emily; Friedmann, David; Jethanamest, Daniel; McMenomey, Sean; Roland, J Thomas; Waltzman, Susan
OBJECTIVE:To assess the safety of cochlear implants (CIs) in children under 9 months of age to better understand expected postoperative complication rates, and to provide a preliminary look at efficacy. STUDY DESIGN/METHODS:Single-center retrospective review. SETTING/METHODS:Tertiary referral center. PATIENTS/METHODS:Children 5 to 8 months of age who received a CI between 2011 and 2021. INTERVENTIONS/METHODS:Therapeutic-CI. MAIN OUTCOME MEASURES/METHODS:The primary outcome was 6-month postoperative complication rate. Secondary outcomes included length of stay, device explantation/reimplantation, rehabilitation supports, and hearing and language outcomes. Complications of children implanted under than 9 months of age was compared with a cohort of children implanted 9 to 18 months of age between the years 2011 and 2016 using a chi-squared test (p < 0.05). RESULTS:One hundred six children under 9 months of age were implanted (204 CIs) at a mean age of 6.6 months (range: 5-8). Postoperative complications occurred in 28 patients (26%) and were often minor. There were no mortalities. There was no statistically significant difference in complications, including reimplantation rates, between patients implanted under 9 months of age and those implanted 9 to 18 months of age. Speech discrimination outcomes were excellent, and mean spoken language outcomes were near normative for typically developing children. CONCLUSIONS:Cochlear implantation can be a safe and effective treatment option for children 5 to 8 months of age. Early hearing screening and referral for infants to receive appropriate intervention will continue to play a critical role in optimizing speech and language outcomes.
PMID: 38082466
ISSN: 1537-4505
CID: 5589152
Characterizing Hearing Outcomes Following Treatment of Cerebellopontine Angle Meningiomas
Papazian, Michael; Cottrell, Justin; Pan, Lydia; Kay-Rivest, Emily; Friedmann, David R.; Jethanamest, Daniel; Kondziolka, Douglas; Pacione, Donato; Sen, Chandranath; Golfinos, John G.; Roland, J. Thomas; McMenomey, Sean O.
Objectives To characterize treatment and hearing outcomes for cerebellopontine angle (CPA) meningiomas with inherent risks of hearing loss and identify predictors of hearing loss for surgically treated lesions. Design Retrospective chart review. Setting Tertiary care medical center. Participants Adult patients with CPA meningiomas impinging upon cranial nerve VIII and/or pretreatment hearing loss managed with microsurgery or stereotactic radiosurgery (SRS) with Gamma Knife at our center between 2012 and 2023. Main Outcome Measures Hearing preservation rate was determined from analysis of patients with pretreatment serviceable hearing for whom hearing-preserving treatment was attempted. Surgical patients were further analyzed using multivariable Cox proportional hazards regression models to identify factors predictive of postoperative hearing loss. Results We identified 80 patients with CPA meningiomas meeting inclusion criteria who were managed with either microsurgery (43, 54%) or radiosurgery (37, 46%). Following SRS, hearing was preserved in 88% of cases. Following microsurgery, hearing was preserved in 71% of patients-all patients who lost hearing had tumors involving the internal auditory canal (IAC). Among surgical patients only, multivariable analysis accounting for preoperative hearing, recurrence status, lesion size, and patient age, the preoperative imaging finding that the CPA meningioma surrounded the vestibulocochlear nerve was significantly associated with hearing loss (hazard ratio: 10.3, 95% confidence interval: 1.3-81.4, p = 0.02). Conclusion Most patients with meningiomas of the CPA can experience preservation of hearing, even when there is risk of hearing loss based on pretreatment evaluation. IAC invasion and surrounding of eighth nerve by tumor may portend poorer hearing outcomes in surgically managed patients.
SCOPUS:85204132363
ISSN: 2193-6331
CID: 5716162
Bilateral cochlear implantation after immunotherapy-related profound hearing loss: A case report [Case Report]
Schlacter, Jamie A; Kay-Rivest, Emily; McMenomey, Sean O; Roland, J Thomas; Friedmann, David R; Jethanamest, Daniel
OBJECTIVES:Immune-checkpoint inhibitors (ICI) are being utilized with increasing frequency and may be linked to neurologic and audiovestibular toxicities. This report aimed to describe a case of ICI-induced sensorineural hearing loss ultimately requiring bilateral cochlear implantation. METHODS:A 42-year-old female with stage IV metastatic melanoma of the perianal skin was treated with ipilimumab (blocker of cytotoxic T-lymphocyte associated protein 4 [CTLA-4]) and nivolumab (anti-programmed cell death protein 1 [PD1]). After 21 weeks of therapy, she developed sudden vertigo and bilateral hearing loss. A full workup including MRI and lumbar puncture ruled out intracranial parenchymal metastases, leptomeningeal metastases, stroke and intracranial infection. ICI-associated aseptic meningoencephalitis was therefore diagnosed. The patient received systemic steroids as well as intratympanic steroids, which temporarily improved hearing, but eventually developed permanent, bilateral profound sensorineural hearing loss. RESULTS:The patient received bilateral cochlear implants and has demonstrated good performance one year after implantation. DISCUSSION:ICI are being increasingly used to treat a variety of advanced malignancies. This is the first report of bilateral cochlear implants in the context of profound hearing loss after an immunotherapy induced meningoencephalitis. CONCLUSION:ICI carries the risk of potential ototoxicity, including profound SNHL as depicted in our case. Cochlear implantation proved to be beneficial and may be considered in patients with ICI-related hearing loss.
PMID: 36988037
ISSN: 1754-7628
CID: 5591702
Prospective Assessment of Otologic Adverse Events due to Teprotumumab: Preliminary Results
Kay-Rivest, Emily; Belinsky, Irina; Kozlova, Anna; Byrd, Erin; McMenomey, Sean O; Jethanamest, Daniel
OBJECTIVE:To assess a series of patients receiving teprotumumab therapy and objectively quantify the rates of otologic adverse events. STUDY DESIGN:A prospective cohort study of adult patients receiving teprotumumab between May 2020 and January 2022. SETTING:Tertiary referral center. METHODS:Prior to treatment initiation, an ototoxicity-specific audiometric battery was completed, which included conventional audiometry (frequencies 250-8000 Hz), ultrahigh-frequency audiometry (9000-20,000 Hz), tympanometry, speech discrimination scores, and distortion product otoacoustic emissions (DPOAEs). Testing was then repeated after treatment completion. RESULTS:In total, 35 patients were recruited, with a median (range) age of 48.5 years (21-74), and 8 (22.8%) were male. The most common subjective symptom reported was a hearing decline (25.7%), followed by aural fullness (17.1%) and tinnitus (14.3%). Fourteen patients had both pre- and posttreatment audiometric data. Among them, 3 patients (21.4%) were found to have changes in standard frequency audiometry, and 10 (71.4%) had changes in high-frequency audiometry, with 2 patients having changes in both. Less than half (n = 5) of the 11 patients with changes in standard or high-frequency pure tone hearing noted subjective hearing decline. Changes in DPOAE were noted in 4 patients out of 13 (30.7%). Two patients discontinued treatment due to hearing decline. Finally, 3 patients (8.6%) were diagnosed with patulous eustachian tube (PET) by an otolaryngologist, and another 3 patients are suspected to have PET based on symptom description during ophthalmologic follow-up. CONCLUSION:In our cohort, a high incidence of otologic symptoms was found to be associated with teprotumumab usage. Subjective hearing decline, changes in ultrahigh-frequency hearing as well as eustachian tube dysfunction may be encountered and suggest the potential ototoxicity of teprotumumab.
PMID: 36939482
ISSN: 1097-6817
CID: 5462732