Searched for: in-biosketch:true
person:bamird01
Device-Associated Thrombus with Watchman FLX Left Atrial Appendage Closure Device: A Report of Two Cases [Case Report]
Dhaduk, Nehal; Vainrib, Alan F; Bamira, Daniel; Ro, Richard; Aizer, Anthony; Chinitz, Larry; Saric, Muhamed
• Individual cases of Watchman FLX DAT are scare in literature. • The Watchman FLX has shown lower rates of DAT than the Watchman 2.0. • Thrombus formation is still possible in rare instances with the Watchman FLX.
PMCID:10307589
PMID: 37396475
ISSN: 2468-6441
CID: 5538982
Transesophageal Echocardiographic Screening for Structural Heart Interventions
Ro, Richard; Bamira, Daniel; Bernard, Samuel; Vainrib, Alan; Ibrahim, Homam; Staniloae, Cezar; Williams, Mathew R; Saric, Muhamed
PURPOSE OF REVIEW/OBJECTIVE:Percutaneous structural interventions have provided patients with an effective therapeutic option, and its growth has been aided by echocardiography. We describe the vital role that transesophageal echocardiography (TEE) plays in screening patients prior to their procedure. RECENT FINDINGS/RESULTS:A multimodality imaging approach is employed by the valve team, but TEE plays a unique role in diagnosis and planning. Utilization of all TEE views and features such as biplane, 3D imaging, and multiplanar reconstruction ensures accurate assessment of the structural lesion of interest. The role of TEE remains essential in the planning of structural interventions, and these studies should be performed in a systematic and comprehensive manner.
PMID: 36680732
ISSN: 1534-3170
CID: 5405192
Taking Command of 3D Stitching Artifacts: From an Annoyance to an Easy Tool for Navigating 3D Transesophageal Echocardiography
Maidman, Samuel D; Bamira, Daniel; Ro, Richard; Vainrib, Alan F; Saric, Muhamed
Despite many recent advances in three-dimensional (3D) transesophageal (TEE) imagining, the process of orienting 3D TEE images is nonintuitive and uses assumptions based on idealized anatomy. Correlating two-dimensional (2D) TEE cross-sectional images to 3D reconstructions remains an additional challenge. Here, we suggest the repurposing of the stitching artifact generated in 2-beat ECG-gated 3D TEE as a means of exactly orienting 3D images within a patient's unique anatomy. In this article, we demonstrate this application of this strategy to assess a normal mitral valve (MV), to localize scallops of mitral valve prolapse and to visualize typical left atrial appendage 2D cuts in a 3D space. By taking command of stitching artifacts, cardiac imagers can successfully navigate the complex structures of the heart for optimal, individualized echocardiographic views.
PMID: 36174809
ISSN: 1097-6795
CID: 5334502
Mitral Valve-in-Ring Leaflet Thrombosis: A Multimodality Imaging Primer [Case Report]
Hayes, Dena E; Bamira, Daniel; Vainrib, Alan F; Staniloae, Cezar; Jilaihawi, Hasan; Williams, Mathew; Saric, Muhamed
PMCID:9510672
PMID: 36172479
ISSN: 2468-6441
CID: 5334432
Response to Letter to the Editor: Multimodality Imaging of Sinus Venosus Atrial Septal Defect: A Challenging Diagnosis in Adults
Qiu, Jessica K; Bamira, Daniel; Vainrib, Alan F; Latson, Larry A; Halpern, Dan G; Chun, Anne; Saric, Muhamed
PMCID:9120830
PMID: 35602979
ISSN: 2468-6441
CID: 5283782
Multimodality Imaging of Sinus Venosus Atrial Septal Defect: A Challenging Diagnosis in Adults [Case Report]
Qiu, Jessica K; Bamira, Daniel; Vainrib, Alan F; Latson, Larry A; Halpern, Dan G; Chun, Anne; Saric, Muhamed
PMCID:9120852
PMID: 35602989
ISSN: 2468-6441
CID: 5232842
Native mitral valve staphylococcus endocarditis with a very unusual complication: Ruptured posterior mitral valve leaflet aneurysm [Case Report]
Maidman, Samuel D; Kiefer, Nicholas J; Bernard, Samuel; Freedberg, Robin S; Rosenzweig, Barry P; Bamira, Daniel; Vainrib, Alan F; Ro, Richard; Neuburger, Peter J; Basu, Atreyee; Moreira, Andre L; Latson, Larry A; Loulmet, Didier F; Saric, Muhamed
Infective endocarditis (IE) is a life-threatening disease associated with in-hospital mortality of nearly one in five cases. IE can destroy valvular tissue, which may rarely progress to aneurysm formation, most commonly at the anterior leaflet in instances of mitral valve involvement. We present a remarkable case of a patient with IE and a rare complication of a ruptured aneurysm of the posterior leaflet of the mitral valve. Two- and Three-dimensional transesophageal echocardiography, intra-operative videography, and histopathologic analysis revealed disruption at this unusual location-at the junction of the P2 and P3 scallops, surrounded by an annular abscess.
PMID: 34923683
ISSN: 1540-8175
CID: 5108652
Cor Pulmonale from Concomitant Human Immunodeficiency Virus Infection and Methamphetamine Use [Case Report]
Maidman, Samuel D; Sulica, Roxana; Freedberg, Robin S; Bamira, Daniel; Vainrib, Alan F; Ro, Richard; Latson, Larry A; Saric, Muhamed
PMCID:8370868
PMID: 34430775
ISSN: 2468-6441
CID: 5148322
Two cases of acute endocarditis misdiagnosed as COVID-19 infection
Hayes, Dena E; Rhee, David W; Hisamoto, Kazuhiro; Smith, Deane; Ro, Richard; Vainrib, Alan F; Bamira, Daniel; Zhou, Fang; Saric, Muhamed
The COVID-19 pandemic has presented countless new challenges for healthcare providers including the challenge of differentiating COVID-19 infection from other diseases. COVID-19 infection and acute endocarditis may present similarly, both with shortness of breath and vital sign abnormalities, yet they require very different treatments. Here, we present two cases in which life-threatening acute endocarditis was initially misdiagnosed as COVID-19 infection during the height of the pandemic in New York City. The first was a case of Klebsiella pneumoniae mitral valve endocarditis leading to papillary muscle rupture and severe mitral regurgitation, and the second a case of Streptococcus mitis aortic valve endocarditis with heart failure due to severe aortic regurgitation. These cases highlight the importance of careful clinical reasoning and demonstrate how cognitive errors may impact clinical reasoning. They also underscore the limitations of real-time reverse transcription-polymerase chain reaction (RT-PCR) for SARS-CoV-2 testing and illustrate the ways in which difficulty interpreting results may also influence clinical reasoning. Accurate diagnosis of acute endocarditis is critical given that surgical intervention can be lifesaving in unstable patients.
PMID: 33715241
ISSN: 1540-8175
CID: 4817282
Long-term outcomes after transcatheter aortic valve replacement with minimal contrast in chronic kidney disease
Rzucidlo, Justyna; Jaspan, Vita; Paone, Darien; Jilaihawi, Hasan; Xia, Yuhe; Kapitman, Anna; Nakashima, Makoto; He, Yuxin; Ibrahim, Homam; Pushkar, Illya; Neuburger, Peter J; Saric, Muhamed; Bamira, Daniel; Paschke, Sonja; Kalish, Chloe; Staniloae, Cezar; Shah, Binita; Williams, Mathew
BACKGROUND:Patients with renal insufficiency have poor short-term outcomes after transcatheter aortic valve replacement (TAVR). METHODS:Retrospective chart review identified 575 consecutive patients not on hemodialysis who underwent TAVR between September 2014 and January 2017. Outcomes were defined by VARC-2 criteria. Primary outcome of all-cause mortality was evaluated at a median follow-up of 811 days (interquartile range 125-1,151). RESULTS:Preprocedural glomerular filtration rate (GFR) was ≥60 ml/min in 51.7%, 30-60 ml/min in 42.1%, and < 30 ml/min in 6.3%. Use of transfemoral access (98.8%) and achieved device success (91.0%) did not differ among groups, but less contrast was used with lower GFR (23 ml [15-33], 24 ml [14-33], 13 ml [8-20]; p < .001). Peri-procedural stroke (0.7%, 2.1%, 11.1%; p < .001) was higher with lower GFR. Core lab analysis of preprocedural computed tomography scans of patients who developed a peri-procedural stroke identified potential anatomic substrate for stroke in three out of four patients with GFR 30-60 ml/min and all three with GFR <30 ml/min (severe atheroma was the most common subtype of anatomical substrate present). Compared to GFR ≥60 ml/min, all-cause mortality was higher with GFR 30-60 ml/min (HR 1.61 [1.00-2.59]; aHR 1.61 [0.91-2.83]) and GFR <30 ml/min (HR 2.41 [1.06-5.48]; aHR 2.34 [0.90-6.09]) but not significant after multivariable adjustment. Follow-up echocardiographic data, available in 63%, demonstrated no difference in structural heart valve deterioration over time among groups. CONCLUSIONS:Patients with baseline renal insufficiency remain a challenging population with poor long-term outcomes despite procedural optimization with a transfemoral-first and an extremely low-contrast approach.
PMID: 33180381
ISSN: 1522-726x
CID: 4665422