Searched for: in-biosketch:true
person:sonodt02
Systematic Video Documentation in Laparoscopic Colon Surgery Using a Checklist: A Feasibility and Compliance Pilot Study
O'Mahoney, Paul R A; Trencheva, Koiana; Zhuo, Changhua; Shukla, Parul J; Lee, Sang W; Sonoda, Toyooki; Milsom, Jeffrey W
BACKGROUND:High-quality images can be readily captured during laparoscopic colon surgery, but there are no guidelines for documentation of these video data or how to best measure surgical quality from an operative video. This study evaluates the feasibility and compliance in documenting key steps during laparoscopic right hemicolectomy and sigmoid colectomy. MATERIALS AND METHODS/METHODS:A retrospective review of previously recorded videos of patients undergoing laparoscopic right hemicolectomy or sigmoid colectomy from September to December 2011 in a single institution was performed. Patients' demographics, intraoperative features, postoperative complications, and variables for video recording and editing were collected. Compliance of key surgical steps was assessed using a checklist by two independent surgeons. RESULTS:Sixteen laparoscopic operations (seven right hemicolectomies and nine sigmoid colectomies) were recorded. Twelve (75%) were laparoscopic-assisted, and four (25%) were hand-assisted laparoscopic operations. Compliance with key surgical steps in laparoscopic right hemicolectomy and sigmoid colectomy was demonstrated in the majority of patients, with steps ranging in compliance from 42.9% to 100% and from 77.8% to 100%, respectively. The edited video had a median duration of 3 minutes 47 seconds (range, 1 minute 44 seconds-5 minutes 38 seconds) with a production time of nearly 1 hour and a resolution of 1440 × 1080 pixels. CONCLUSIONS:Key surgical steps during laparoscopic right hemicolectomy and sigmoid colectomy can be documented and edited into a short representative video. Standardization of this process should allow video documentation to improve quality in laparoscopic colon surgery.
PMID: 26375772
ISSN: 1557-9034
CID: 3525422
Reply to Letter: "Identifying Important Predictors for Anastomotic Leak After Colon and Rectal Resection: Prospective Study on 616 Patients" [Letter]
Trencheva, Koianka; Morrissey, Kevin P; Wells, Martin; Mancuso, Carol A; Lee, Sang W; Sonoda, Toyooki; Michelassi, Fabrizio; Charlson, Mary E; Milsom, Jeffrey W
PMID: 24487748
ISSN: 1528-1140
CID: 3525382
Reply to letter: "identifying important predictors for anastomotic leak after colon and rectal resection: prospective study on 616 patients" [Letter]
Trencheva, Koianka; Morrissey, Kevin P; Wells, Martin; Mancuso, Carol A; Lee, Sang W; Sonoda, Toyooki; Michelassi, Fabrizio; Charlson, Mary E; Milsom, Jeffrey W
PMID: 24100340
ISSN: 1528-1140
CID: 3525372
Prospective multicenter study of a synthetic bioabsorbable anal fistula plug to treat cryptoglandular transsphincteric anal fistulas
Stamos, Michael J; Snyder, Michael; Robb, Bruce W; Ky, Alex; Singer, Marc; Stewart, David B; Sonoda, Toyooki; Abcarian, Herand
BACKGROUND:Although interest in sphincter-sparing treatments for anal fistulas is increasing, few large prospective studies of these approaches have been conducted. OBJECTIVE:The study assessed outcomes after implantation of a synthetic bioabsorbable anal fistula plug. DESIGN/METHODS:A prospective, multicenter investigation was performed. SETTING/METHODS:The study was conducted at 11 colon and rectal centers. PATIENTS/METHODS:Ninety-three patients (71 men; mean age, 47 years) with complex cryptoglandular transsphincteric anal fistulas were enrolled. Exclusion criteria included Crohn's disease, an active infection, a multitract fistula, and an immunocompromised status. INTERVENTION/METHODS:Draining setons were used at the surgeon's discretion. Patients had follow-up evaluations at 1, 3, 6, and 12 months postoperatively. MAIN OUTCOME MEASURES/METHODS:The primary end point was healing of the fistula, defined as drainage cessation plus closure of the external opening, at 6 and 12 months. Secondary end points were fecal continence, duration of drainage from the fistula, pain, and adverse events during follow-up. RESULTS:Thirteen patients were lost to follow-up and 21 were withdrawn, primarily to undergo an alternative treatment. The fistula healing rates at 6 and 12 months were 41% (95% CI, 30%-52%; total n = 74) and 49% (95% CI, 38%-61%; total n = 73). Half the patients in whom a previous treatment failed had healing. By 6 months, the mean Wexner score had improved significantly (p = 0.0003). By 12 months, 93% of patients had no or minimal pain. Adverse events included 11 infections/abscesses, 2 new fistulas, and 8 total and 5 partial plug extrusions. The fistula healed in 3 patients with a partial extrusion. LIMITATIONS/CONCLUSIONS:The study was nonrandomized and had relatively high rates of loss to follow-up. CONCLUSION/CONCLUSIONS:Implantation of a synthetic bioabsorbable fistula plug is a reasonably efficacious treatment for complex transsphincteric anal fistulas, especially given the simplicity and low morbidity of the procedure.
PMID: 25664714
ISSN: 1530-0358
CID: 3525412
Laparoscopic resection of t4 colon cancers: is it feasible?
Shukla, Parul J; Trencheva, Koiana; Merchant, Chetan; Maggiori, Leon; Michelassi, Fabrizio; Sonoda, Toyooki; Lee, Sang W; Milsom, Jeffrey W
BACKGROUND:Laparoscopic surgical treatment of T4 cancers remains a concern that is mostly associated with technical feasibility, high conversion rate, inadequate oncologic clearance, and surgical outcome. OBJECTIVE:The purpose of this work was to evaluate the short- and long-term clinical and oncologic outcomes after laparoscopic and open surgeries for T4 colon cancers. DESIGN/METHODS:This was a retrospective study of patients with T4 colon cancer without metastasis (M0) who had laparoscopic or open surgery from 2003 to 2011. SETTING/METHODS:The study was conducted at a single institution. PATIENTS/METHODS:A total of 83 patients with pT4 colon cancer were included. MAIN OUTCOME MEASURES/METHODS:R0 resection rate, morbidity and mortality within 30 postoperative days, overall survival, and disease-free survival were measured. RESULTS:Laparoscopic surgery was performed on 61 and open surgery on 22 patients. The groups were similar in overall staging (p = 0.461), with 35 (42%) of the patients at stage 2 and 48 (58%) at stage 3. A complete R0 resection was achieved in 61 (100%) of the patients who underwent laparoscopic surgery and in 21 (96%) of the patients who underwent open surgery (p = 0.265). The average number of lymph nodes harvested was 21 in the laparoscopic group and 24 in the open group (p = 0.202). Thirty-day morbidity rate was similar between the groups (p = 0.467), and the mortality rate was 0. The length of hospital and postsurgical stay was significantly shorter in the laparoscopic group (p = 0.002 and p = 0.008). The 3-year overall survival rates between the groups were 82% (range, 71%-93%) for patients who underwent laparoscopic surgery and 81% (range, 61%-100%) for those who underwent open surgery (p = 0.525), and disease-free survival was 67% (range, 54%-79%) for laparoscopic surgery and 64% (range, 43%-86%) for open surgery (p = 0.848). The follow-up time was 40 ± 25 in months in the laparoscopic group and 34 ± 26 months in the open surgery group (p = 0.325). LIMITATIONS/CONCLUSIONS:This was a retrospective study at a single institution. CONCLUSIONS:The study shows that laparoscopic surgery is feasible in T4 colon cancers. With comparable clinical and oncologic outcomes, this study suggests that laparoscopy may be considered as an alternative approach for T4 colon cancers with the advantage of faster recovery (see Video, Supplemental Digital Content 1, http://links.lww.com/DCR/A156).
PMID: 25489691
ISSN: 1530-0358
CID: 3525402
Accuracy of CT enterography and magnetic resonance enterography imaging to detect lesions preoperatively in patients undergoing surgery for Crohn's disease
Seastedt, Kenneth P; Trencheva, Koiana; Michelassi, Fabrizio; Alsaleh, Doaa; Milsom, Jeffrey W; Sonoda, Toyooki; Lee, Sang W; Nandakumar, Govind
BACKGROUND:CT enterography and magnetic resonance enterography have emerged as first-line imaging technologies for the evaluation of the gastrointestinal tract in Crohn's disease. OBJECTIVE:The purpose of this work was to evaluate the accuracy of these imaging modalities to identify Crohn's disease lesions preoperatively. DESIGN/METHODS:This was a retrospective chart review. SETTINGS/METHODS:The study was conducted at a single institution. PATIENTS/METHODS:Seventy-six patients with Crohn's disease with preoperative CT enterography and/or magnetic resonance enterography were included in the study. MAIN OUTCOME MEASURES/METHODS:The number of stenoses, fistulas, and abscesses on CT enterography and/or magnetic resonance enterography before surgery were compared with operative findings. RESULTS:Forty patients (53%) were women, 46 (60%) underwent surgery for recurrent Crohn's disease, and 46 (57%) had previous abdominal surgery. Thirty-six (47%) had a preoperative CT enterography and 43 (57%) had a preoperative magnetic resonance enterography. CT enterography sensitivity was 75% for stenosis and 50% for fistula. MRE sensitivity was 68% for stenosis and 60% for fistula. The negative predictive values of CT enterography and magnetic resonance enterography for stenosis were very low (54% and 65%) and were 85% and 81% for fistula. CT enterography had 76% accuracy for stenosis and 79% for fistula; magnetic resonance enterography had 78% accuracy for stenosis and 85% for fistula. Both were accurate for abscess. False-negative rates for CT enterography were 50% for fistula and 25% for stenosis. False-negative rates for magnetic resonance enterography were 40% for fistula and 32% for stenosis. Unexpected intraoperative findings led to modification of the planned surgical procedure in 20 patients (26%). LIMITATIONS/CONCLUSIONS:This study was limited by its small sample size, its retrospective nature, and that some studies were performed at outside institutions. CONCLUSIONS:CT enterography and magnetic resonance enterography in patients with Crohn's disease were accurate for the identification of abscesses but not for fistulas or stenoses. Surgeons should search for additional lesions intraoperatively. Patients should be appropriately counseled regarding the need for unexpected interventions (see Video, Supplemental Digital Content 1, http://links.lww.com/DCR/A162).
PMID: 25380001
ISSN: 1530-0358
CID: 3525392
Dynamic article: long-term outcomes of patients undergoing combined endolaparoscopic surgery for benign colon polyps
Lee, Sang W; Garrett, Kelly A; Shin, Joong H; Trencheva, Koiana; Sonoda, Toyooki; Milsom, Jeffrey W
BACKGROUND:Patients with large benign colon polyps not amenable to endoscopic removal commonly undergo resections. Polyp removal using combined endolaparoscopic surgery may be an effective alternative to bowel resection in select patients. OBJECTIVE:The aim of this study was to evaluate short-term and long-term outcomes of patients who underwent endolaparoscopy at our institution. DATA SOURCES/METHODS:Medical records and a prospectively maintained database were reviewed. STUDY SELECTION/METHODS:This study constituted a retrospective review of consecutive patients who underwent endolaparoscopy for benign polyps from 2003 to 2012. INTERVENTIONS/METHODS:Combined endolaparoscopic surgery was performed. MAIN OUTCOME MEASURES/METHODS:The primary outcomes measured were success rate, rate of recurrence, rate of malignancy, length of stay, and complication rate. RESULTS:A total of 75 patients were taken to the operating room with the intention of endolaparoscopy. The most common indications were large polyp size and difficult location. Based on intraoperative findings, 10 patients were suspected of having cancer and underwent immediate laparoscopic colectomy. Of 65 attempted cases, 48 patients (74%) underwent successful combined endolaparoscopic surgery. Median follow-up time was 65 (8-87) months. Patients in whom combined endolaparoscopic surgery was unsuccessful were converted to colectomy (2 open, 15 laparoscopic). Two patients were converted because of concerns of cancer and 15 because of technical difficulties. Median operative time for successful endolaparoscopy was 145 (50-249) minutes. The complication rate was 4.4% (2/48). Median length of stay was 1 (0-6) day for endolaparoscopy vs 5 (3-19) days for those converted to colectomy. Median polyp size was 3 (1.0-7.0) cm. One patient was found to have cancer on final pathology, but refused to have further surgery. Sensitivity and specificity of predicting malignancy based on clinical findings were 33% (4/12) and 98.5% (64/65). Four of 5 patients who had recurrence (10%) after endolaparoscopy had complete endoscopic polypectomy. One patient required delayed laparoscopic colectomy for a second recurrence. LIMITATIONS/CONCLUSIONS:This study was limited by its retrospective nature. CONCLUSIONS:Combined endolaparoscopic surgery appears to be a safe and effective alternative to colectomy in all parts of the colon in patients who have benign polyps not removable with colonoscopy alone.
PMID: 23739193
ISSN: 1530-0358
CID: 3525362
Identifying important predictors for anastomotic leak after colon and rectal resection: prospective study on 616 patients
Trencheva, Koianka; Morrissey, Kevin P; Wells, Martin; Mancuso, Carol A; Lee, Sang W; Sonoda, Toyooki; Michelassi, Fabrizio; Charlson, Mary E; Milsom, Jeffrey W
OBJECTIVE:The purpose of this study was to identify patient, clinical, and surgical factors that may predispose patients to anastomotic leak (AL) after large bowel surgery. BACKGROUND:Anastomotic leak is still one of the most devastating complications following colorectal surgery. Knowledge about factors predisposing patients to AL is vital to its early detection, decision making for surgical time, managing preoperative risk factors, and postoperative complications. METHODS:This was a prospective observational, quality improvement study in a cohort of 616 patients undergoing colorectal resection in a single institution with the main outcome being AL within 30 days postoperatively. Some of the predictor variables were age, sex, Charlson Comorbidity Index (CCI), radiation and chemotherapy, immunomodulator medications, albumin, preoperative diagnoses, surgical procedure(s), surgical technique (laparoscopic vs open), anastomotic technique (staple vs handsewn), number of major arteries ligated at surgery, surgeon's experience, presence of infectious condition at surgery, intraoperative adverse events, and functional status using 36-Item Short Form General Health Survey. RESULTS:Of the 616 patients, 53.4% were female. The median age of the patients was 63 years and the mean body mass index was 25.9 kg/m. Of them, 80.3% patients had laparoscopic surgery and 19.5% had open surgery. AL occurred in 5.7% (35) patients. In multivariate analysis, significant independent predictors for leak were anastomoses less than 10 cm from the anal verge, CCI of 3 or more, high inferior mesenteric artery ligation (above left colic artery), intraoperative complications, and being of the male sex. CONCLUSIONS:Multiple risk factors exist that predispose patients to ALs. These risk factors should be considered before and during the surgical care of colorectal patients.
PMID: 22968068
ISSN: 1528-1140
CID: 3525342
Improved access and visibility during stapling of the ultra-low rectum: a comparative human cadaver study between two curved staplers
Rivadeneira, David E; Verdeja, Juan Carlos; Sonoda, Toyooki
UNLABELLED/: BACKGROUND:The purpose of this study was to compare in human cadavers the applicability of a commonly used stapling device, the CONTOUR® curved cutter (CC) (Ethicon Endo-Surgery, Cincinnati, OH) to a newly released, curved stapler, the Endo GIA™ Radial Reload with Tri-Staple™ Technology (RR) (Covidien, New Haven, CT) METHODS: Four experienced surgeons performed deep pelvic dissection with total mesorectal excision (TME) of the rectum in twelve randomized male cadavers. Both stapling devices were applied to the ultra-low rectum in coronal and sagittal configurations. Extensive measurements were recorded of anatomic landmarks for each cadaver pelvis along with various aspects of access, visibility, and ease of placement for each device. RESULTS:The RR reached significantly lower into the pelvis in both the coronal and sagittal positions compared to the CC. The median distance from the pelvic floor was 1.0 cm compared to 2.0 cm in the coronal position, and 1.0 cm versus 3.3 cm placed sagitally, p < 0.0001. Surgeons gave a higher visibility rating with less visual impediment in the sagittal plane using the RR Stapler. Impediment of visibility occurred in only 10% (5/48) of RR applications in the coronal position, compared to a rate of 48% (23/48) using the CC, p = 0.0002. CONCLUSIONS:The RR device performed significantly better when compared to the CC stapler in regards to placing the stapler further into the deep pelvis and closer to the pelvic floor, while causing less obstructing of visualization.
PMID: 23148602
ISSN: 1750-1164
CID: 3525352
Evaluation of the safety, efficacy, and versatility of a new surgical energy device (THUNDERBEAT) in comparison with Harmonic ACE, LigaSure V, and EnSeal devices in a porcine model
Milsom, Jeffrey; Trencheva, Koiana; Monette, Sebastien; Pavoor, Raghava; Shukla, Parul; Ma, Junjun; Sonoda, Toyooki
BACKGROUND:THUNDERBEAT™ (TB) (Olympus, Japan) simultaneously delivers ultrasonically generated frictional heat energy and electrically generated bipolar energy. The aim of this study was to evaluate the versatility, bursting pressure, thermal spread, and dissection time of the TB compared with commercially available devices: Harmonic(®) ACE (HA) (Ethicon Endo-Surgery, USA), LigaSure™ V (LIG) (Covidien, USA), and EnSeal(®) (Ethicon). METHODS:An acute study was done with 10 female Yorkshire pigs (weighing 30-35 kg). Samples 2 cm long of small (2-3 mm)-, medium (4-5 mm)-, and large (6-7 mm)-diameter vessels were created. One end of the sample was sent for histological evaluation, and the other was used for burst pressure testing in a blinded fashion. Versatility was defined as the performance of the surgical instrument based on the following five variables, using a score from 1 to 5 (1=worst, 5=best), adjusted by coefficient of variable importance with weighted distribution: hemostasis, 0.275; histologic sealing, 0.275; cutting, 0.2; dissection, 0.15; and tissue manipulation, 0.1. There were 80 trials per vessel group and 60 trials per instrument group, giving a total of 240 samples. RESULTS:Versatility score was higher (P<.01) and dissection time was shorter (P<.01) using TB compared with the other three devices. Bursting pressure was similar among TB and the other three instruments. Thermal spread at surgery was similar between TB and HA (P=.4167), TB and EnSeal (P=.6817), and TB and LIG (P=.8254). Difference in thermal spread was noted between EnSeal and HA (P=.0087) and HA and LIG (P=.0167). CONCLUSION/CONCLUSIONS:TB has a higher versatility compared with the other instruments tested with faster dissection speed, similar bursting pressure, and acceptable thermal spread. This new energy device is an appealing, safe alternative for cutting, coagulation, and tissue dissection during surgery and should decrease time and increase versatility during surgical procedures.
PMID: 22364404
ISSN: 1557-9034
CID: 3525332