Try a new search

Format these results:

Searched for:

in-biosketch:true

person:teterk01

Total Results:

24


Risk Factors For and Intra-operative Management of Intolerance to Flow Reversal in TCAR

Teter, Katherine; Rockman, Caron; Lamparello, Patrick; Macdonald, Sumaira; Garg, Karan; Barfield, Michael; Maldonado, Thomas S
OBJECTIVES/OBJECTIVE:In patients deemed high risk for carotid endarterectomy (CEA) who are indicated for treatment of carotid artery stenosis (CAS), transcarotid artery revascularization (TCAR) has been demonstrated as a safe and effective alternative to trans-femoral carotid artery stenting (TF-CAS). Compared to CEA, where approx. 12% of patients undergoing awake intervention do not tolerate internal carotid artery (ICA) clamping, only 1-2% of patients were observed to have intolerance to flow reversal during TCAR based on data from the ROADSTER1/2 trials. This study reviewed awake interventions from those trials to assess factors associated with intolerance to flow reversal and review how those cases were managed. METHODS:This is a retrospective review of prospectively collected data from Reverse Flow Used During Carotid Artery Stenting Procedure (ROADSTER) multicenter trial along with the subsequent post-approval (ROADSTER-2) trial. The subset of patients from both trials undergoing awake TCAR was analyzed to compare demographics, procedural details, and anatomic factors between patients who did and did not experience intolerance to reversal of flow to assess for predisposing factors. Patients were deemed intolerant to flow reversal at the discretion of the operator, often related to changes in completion of neurologic tasks, hemodynamic stability, or patient reported symptoms. RESULTS:103 patients from ROADSTER and 194 patients from ROADSTER-2 underwent TCAR under local/regional anesthesia. Of these, 8 patients had intolerance to flow reversal, though all cases were successfully completed. While intra-operative hemodynamic data was only available for 5 of the 8 intolerant patients, none experienced hypotension. 4 cases were completed under low flow reversal, 3 cases were successfully weaned from low to high flow over several minutes, and 1 case required general anesthesia. No significant association was found between intolerance to flow reversal and comorbidities including diabetes mellitus (DM), hypertension (HTN), hyperlipidemia (HLD), congestive heart failure (CHF), prior MI or angina, pre-op CAS-related symptoms, prior stroke, prior CAS or CEA, prior neck radiation, tandem stenosis, high cervical stenosis, or hostile neck (tables 1, 2). A trend towards significance was seen with chronic obstructive pulmonary disease (COPD) and contralateral carotid artery occlusion (p= 0.086 and 0.139, respectively). CONCLUSIONS:Despite intolerance to flow reversal, TCAR cases were successfully completed by adjusting reversal-of-flow rate and do not typically require conversion to GETA. While factors contributing to intolerance of flow reversal during TCAR remain poorly understood, this study identified a trend towards significance with an association of pre-existing COPD and contralateral carotid artery occlusion. Given the low number of patients who experienced this issue, a larger sample size is required to better elucidate these trends.
PMID: 34688872
ISSN: 1615-5947
CID: 5042142

Abdominal aortic aneurysm neck dilatation and sac remodeling in fenestrated compared to standard endovascular aortic repair

Li, Chong; Teter, Katherine; Rockman, Caron; Garg, Karan; Cayne, Neal; Sadek, Mikel; Jacobowitz, Glenn; Silvestro, Michele; Ramkhelawon, Bhama; Maldonado, Thomas S
OBJECTIVE:Contemporary commercially available endovascular devices for the treatment of abdominal aortic aneurysm (AAA) include standard endovascular aortic repair (sEVAR) or fenestrated EVAR (fEVAR) endografts. However, aortic neck dilatation (AND) can occur in nearly 25% of patients following EVAR, resulting in loss of proximal seal with risk of aortic rupture. AND has not been well characterized in fEVAR, and direct comparisons studying AND between fEVAR and sEVAR have not been performed. This study aims to analyze AND in the infrarenal and suprarenal aortic segments, including seal zone, and quantify sac regression following fEVAR implantation compared to sEVAR. METHOD/METHODS:A retrospective review of prospectively collected data on 20 consecutive fEVAR patients (Cook Zenith® Fenestrated) and 20 sEVAR (Cook Zenith®) patients was performed. Demographic data, anatomic characteristics, procedural details, and clinical outcome were analyzed. Pre-operative, post-operative (1 month), and longest follow-up CT scan at an average of 29.3 months for fEVAR and 29.8 months for sEVAR were analyzed using a dedicated 3D workstation (iNtuition, TeraRecon Inc, Foster City, California). Abdominal aortic aneurysm neck diameter was measured in 5 mm increments, ranging from 20 mm above to 20 mm below the lowest renal artery. Sub-analysis comparing the fEVAR to the sEVAR group at 12 months and at greater than 30 months was performed. Standard statistical analysis was done. RESULTS:Demographic characteristics did not differ significantly between the two cohorts. The fEVAR group had a larger mean aortic diameter at the lowest renal artery, shorter infrarenal aortic neck length, increased prevalence of nonparallel neck shape, and longer AAA length. On follow-up imaging, the suprarenal aortic segment dilated significantly more at all locations in the fEVAR cohort, whereas the infrarenal aortic neck segment dilated significantly less compared to the sEVAR group. Compared to the sEVAR cohort, the fEVAR patients demonstrated significantly greater positive sac remodeling as evident by more sac diameter regression, and elongation of distance measured from the celiac axis to the most cephalad margin of the sac. Device migration, endoleak occurrence, re-intervention rate, and mortalities were similar in both groups. CONCLUSION/CONCLUSIONS:Compared to sEVAR, patients undergoing fEVAR had greater extent of suprarenal AND, consistent with a more diseased native proximal aorta. However, the infrarenal neck, which is shorter and also more diseased in fEVAR patients, appears more stable in the post-operative period as compared to sEVAR. Moreover, the fEVAR cohort had significantly greater sac shrinkage and improved aortic remodeling. The suprarenal seal zone in fEVAR may result in a previously undescribed increased level of protection against infrarenal neck dilatation. We hypothesize that the resultant decreased endotension conferred by better seal zone may be responsible for a more dramatic sac shrinkage in fEVAR.
PMID: 34859694
ISSN: 1708-539x
CID: 5069252

Low-frequency avoidable errors during transcarotid artery revascularization

Teter, Katherine; Lamparello, Patrick J; Barfield, Michael; Rockman, Caron B; Macdonald, Sumaira; Maldonado, Thomas S
OBJECTIVE:Transcarotid artery revascularization (TCAR) seems to be a safe and effective alternative to carotid endarterectomy (CEA) and transfemoral carotid artery stenting (TF-CAS). The TCAR system represents a paradigm shift in the management of carotid artery stenosis with potential for a significant decrease in periprocedural morbidity. However, as with CEA or TF-CAS, TCAR is associated with infrequent complications related to user technical error, most of which are preventable. Our goal is to describe these low-frequency events, and to provide guidelines for avoiding them. METHODS:The U.S. Food and Drug Administration (FDA) requires that all medical device manufacturers create a system for receiving, reviewing, and evaluating complaints (Code 21 of Federal Regulations 820.198). Silk Road Medical, Inc (Sunnyvale, Calif), has established a process by which all feedback, including complaints that may not meet FDA criteria, is captured and stored in a database for detailed analysis. More than 13,300 cases have been performed; submitted complaints were reviewed for incidents of serious injury and periprocedural complications, above and beyond the device-related events that must be reported to the FDA. RESULTS:A total of 13,334 patients have undergone TCAR worldwide between early 2011 and December 2019 using the SilkRoad device. Reported complications included 173 dissections (1.4% overall rate) of the common carotid artery at the access point, of which 22.5% were managed without intervention or with medical therapy alone and 24.3% were converted to CEA (considered failing safely). Errors in the location of stent deployment occurred in 16 cases (0.13%), with the most common site being the external carotid artery (75%). One wrong side carotid artery stent was placed in a patient with a high midline pattern of the bovine arch. Cranial nerve injury was reported in 11 cases (0.08%), only one of which persisted beyond 3 months. There have been three reported pneumothoraces and one reported chylothorax. Many of these errors can be recognized and prevented with careful attention to detail. CONCLUSIONS:In high-risk patients requiring treatment for carotid artery stenosis, TCAR has been proven as an alternative to TF-CAS with an excellent safety profile. As with CEA or TF-CAS, this procedure has the potential for infrequent complications, often as a result of user technical error. Although significant, these events can be avoided through a review of the collective experience to date and recognition of potential pitfalls, as we have described.
PMID: 33065241
ISSN: 1097-6809
CID: 4798402

Increased Aortic Sac Regression and Decreased Infrarenal Aortic Neck Dilation After Fenestrated Endovascular Aneurysm Repair Compared With Standard Endovascular Aneurysm Repair [Meeting Abstract]

Li, C; Teter, K; Rockman, C; Garg, K; Cayne, N; Veith, F; Sadek, M; Maldonado, T
Objective: Aortic neck dilation (AND) can occur in nearly 25% of patients after EVAR, resulting in loss of proximal seal and aortic rupture. Fenestrated endovascular aneurysm repair (FEVAR) affords increased treatment options for patients with shorter infrarenal aortic necks; however, AND has not been well characterized in these patients. This study sought to compare AND in patients undergoing FEVAR vs standard endovascular aneurysm repair (EVAR).
Method(s): Retrospective review was conducted of prospectively collected data of 20 consecutive FEVAR patients (Cook Zenith fenestrated; Cook Medical, Bloomington, Ind) and 20 EVAR patients (Cook Zenith). Demographic and anatomic characteristics, procedural details, and clinical outcome were analyzed. Preoperative, 1-month postoperative, and longest follow-up computed tomography scans were analyzed using a dedicated three-dimensional workstation. Abdominal aortic aneurysm (AAA) neck diameter was measured in 5-mm increments from the lowest renal artery. Standard statistical analysis was performed.
Result(s): Demographic characteristics did not differ significantly between the two cohorts. The FEVAR group had larger mean aortic diameter at the lowest renal artery, shorter infrarenal aortic neck length, increased prevalence of nonparallel neck shape, and longer AAA length (Table). On follow-up imaging, the suprarenal aortic segment dilated significantly more at all suprarenal locations in the FEVAR cohort, whereas the infrarenal aortic neck segment dilated significantly less compared with the EVAR group (Table). The FEVAR group demonstrated significantly greater sac regression vs the EVAR group. Positive aortic remodeling, as evidenced by increased distance from the celiac axis to the most cephalad margin of the AAA, occurred to a more significant degree in the FEVAR cohort. Device migration, endoleak occurrence, and need for reintervention were similar in both groups.
Conclusion(s): Compared with EVAR, patients undergoing FEVAR had greater extent of suprarenal AND, consistent with a more diseased native proximal aorta. However, the infrarenal neck, which is shorter and also more diseased in FEVAR patients, appears more stable in the postoperative period compared with EVAR cases. Moreover, the FEVAR cohort had significantly greater sac shrinkage and improved aortic remodeling. The suprarenal seal zone in FEVAR may confer a previously undescribed increased level of protection against infrarenal neck dilation and lessen endotension, resulting in more rapid and dramatic sac shrinkage and contributing to a more durable aortic repair. [Formula presented]
Copyright
EMBASE:2008357459
ISSN: 1097-6809
CID: 5184292

Increased Dead Space Ventilation and Refractory Hypercapnia in Patients With Coronavirus Disease 2019: A Potential Marker of Thrombosis in the Pulmonary Vasculature [Case Report]

Oppenheimer, Beno W; Bakker, Jan; Goldring, Roberta M; Teter, Katherine; Green, David L; Berger, Kenneth I
Objectives/UNASSIGNED:Mortality rates in intubated coronavirus disease 2019 patients remain markedly elevated. Some patients develop sudden refractory hypercapnia and hypoxemia not explained by worsening pulmonary parenchymal disease. This case series highlights clinical findings and management of coronavirus disease 2019 patients with refractory hypercapnia despite maximal/optimal ventilatory support. Hypercapnia could not be explained by worsening lung disease or other common factors, and thus, a pulmonary vascular etiology was suggested. The pillars of management were targeted to improve pulmonary vascular patency via aggressive anticoagulation and support right ventricular function. Data Sources/UNASSIGNED:Four consecutive patients with confirmed coronavirus disease 2019 infection with sudden hypercapnia and hypoxemia were included. Data Synthesis/UNASSIGNED:removal was discontinued in three patients over the ensuing 3 weeks, and one patient was discharged home. Conclusions/UNASSIGNED:We speculate that thromboinflammation with pulmonary microvasculature occlusion leads to a sudden increase in dead space and shunt resulting in severe hypercapnia and hypoxemia in coronavirus disease 2019 patients. Early identification of these physiologic and clinical biomarkers could trigger the institution of therapies aiming to reverse the hypercoagulable state and support right ventricular function.
PMCID:7515611
PMID: 33063042
ISSN: 2639-8028
CID: 4641672

Endovenous laser ablation: A comprehensive review

Teter, Katherine A; Kabnick, Lowell S; Sadek, Mikel
OBJECTIVE:To provide an evidence-based overview of endovenous laser ablation and describe its role as an effective and durable technique for the management of superficial venous insufficiency. METHODS:The published literature on the treatment of varicose veins using endovenous laser ablation was reviewed. The literature search focused on the history of endovenous laser ablation, its safety and durability, known complications, and differences in outcomes based on the iterations of fiber type and laser wavelength. RESULTS:Treatment safety and efficacy of endovenous laser ablation appear to be based on the amount of energy administered over a defined distance, or the linear endovenous energy density. The ideal linear endovenous energy density varies with the laser wavelength and fiber-type. Post-operative pain and bruising may be reduced by the use of higher wavelength fibers or the use of radial or jacket-tip fibers as compared to bare-tip fibers. The incidence of endothermal heat-induced thrombosis remains low and has declined with increasing experience. Reports have demonstrated a greater than 90% technical success rate with saphenous endovenous laser ablation, long-term durability of ablation, and commensurate improvement in quality of life. CONCLUSIONS:Endovenous laser ablation is a safe and durable treatment option for the management of incompetent superficial and perforator veins of the lower extremities. As an endothermal technology, it remains a key component of the standard of care for the treatment of chronic venous insufficiency.
PMID: 32631172
ISSN: 1758-1125
CID: 4518922

Intraoperative Management and Factors Contributing to Intolerance of Reversal of Flow in Transcarotid Artery Revascularization [Meeting Abstract]

Teter, K; Rockman, C; Lamparello, P; Garg, K; Barfield, M; Jacobowitz, G; Maldonado, T S
Objective: In patients deemed high risk for carotid endarterectomy (CEA) who are indicated for treatment of carotid artery stenosis (CAS), transcarotid artery revascularization (TCAR) has been demonstrated to be a safe and effective alternative to transfemoral CAS. Compared with CEA, in which approximately 12% of patients undergoing awake intervention do not tolerate internal carotid artery clamping, only 1% to 2% of patients were observed to have intolerance to flow reversal during TCAR based on data from the Safety and Efficacy Study for Reverse Flow Used During Carotid Artery Stenting Procedure (ROADSTER) 1 and 2 trials. This study reviewed awake interventions from those trials to assess factors associated with intolerance to flow reversal and to review how those cases were managed.
Method(s): This is a retrospective review of prospectively collected data from the ROADSTER multicenter trial along with the subsequent postapproval (ROADSTER 2) trial. The subset of patients from both trials undergoing awake TCAR was analyzed to compare demographics, procedural details, and anatomic factors between patients who did and did not experience intolerance to reversal of flow to assess for predisposing factors. Patients were deemed intolerant to flow reversal at the discretion of the operator, often related to changes in completion of neurologic tasks, hemodynamic stability, or patient-reported symptoms.
Result(s): There were 103 patients from ROADSTER and 194 patients from ROADSTER 2 who underwent TCAR under local/regional anesthesia. Of these, eight patients had intolerance to flow reversal, although all cases were successfully completed. Four cases were completed under low-flow reversal, three cases were successfully weaned from low to high flow during several minutes, and one case required general anesthesia. No significant association was found between intolerance to flow reversal and comorbidities including diabetes mellitus, hypertension, hyperlipidemia, congestive heart failure, prior myocardial infarction or angina, preoperative CAS-related symptoms, prior stroke, prior CAS or CEA, prior neck irradiation, tandem stenosis, high cervical stenosis, or hostile neck (Tables I and II). A trend toward significance was seen with chronic obstructive pulmonary disease (P =.086) and contralateral carotid artery occlusion (P =.139).
Conclusion(s): Despite intolerance to flow reversal, most cases were successfully completed by adjusting reversal of flow rate and did not require conversion to general endotracheal anesthesia. Whereas factors contributing to intolerance of flow reversal during TCAR remain poorly understood, this study identified a trend toward significance with an association of pre-existing chronic obstructive pulmonary disease and contralateral carotid artery occlusion. Given the low number of patients who experienced this issue, a larger sample size is required to better elucidate these trends. [Formula presented] [Formula presented]
Copyright
EMBASE:2006737413
ISSN: 1097-6809
CID: 4521792

Aspiration thrombectomy for the management of acute deep venous thrombosis in the setting of venous thoracic outlet syndrome

Teter, Katherine; Arko, Frank; Muck, Patrick; Lamparello, Patrick J; Khaja, Minhaj S; Huasen, Bella; Sadek, Mikel; Maldonado, Thomas S
PMID: 31888420
ISSN: 1708-539x
CID: 4251272

Presentation and Management of Inferior Vena Cava Thrombosis

Teter, Katherine; Schrem, Ezra; Ranganath, Neel; Adelman, Mark; Berger, Jeffrey; Sussman, Rebecca; Ramkhelawon, Bhama; Rockman, Caron; Maldonado, Thomas S
BACKGROUND:Inferior vena cava thrombosis (IVCT), although rare, has a potential for significant morbidity and mortality. IVCT is often a result of IVC filter thrombosis, but it can also occur de novo. Although anticoagulation remains the standard of care, endovascular techniques to restore IVC patency have become key adjunctive therapies in recent years. This study examines a single-center experience with diagnosis and management of IVCT. METHODS:A retrospective Institutional Review Board-approved review of a single-center institutional database was screened to identify IVCT thrombosis using International Classification of Diseases code 453.2 over a 3-year period. Etiology of IVCT was separated into 2 groups: those with IVC thrombosis in the setting of prior IVC filter place and those in whom IVCT occurred de novo. Patient demographics, presenting characteristics, and management of IVCT were examined. Treatment options included expectant management with anticoagulation versus catheter-directed thrombolysis (CDT), mechanical thrombectomy, stenting, or a combination. For those who underwent intervention, technical success, defined as restoration of IVC patency, was assessed. RESULTS:Forty-one unique patients were identified with radiographically confirmed diagnosis of ICVT (mean age 61, range 25-91; 21 female, 51.2%). Eighteen (43.9%) patients presented with thrombosed IVC filter. Risk factors for venous thromboembolism included tobacco usage, current or prior smoking (n = 17, 41.5%), history of prior deep vein thrombosis (n = 25, 61.0%), malignancy (n = 17, 41.5%), use of hormonal supplements (n = 3, 7.3%), known thrombophilia (n = 4, 9.8%), and obesity (body mass index: mean 29, range 18.8-58.53). Eleven patients (26.8%) presented with pulmonary embolism (PE), and of those 63.6% had IVC filter thrombosis (n = 7). Risk of PE was not significantly different between those patients presenting with a thrombosed IVC filter compared to those with de novo IVCT (38.9% vs. 17.4%, P = 0.12) Management of IVCT included anticoagulation alone (n = 27, 65.9%), CDT (n = 5, 12.2%), mechanical thrombolysis (n = 10, 24.4%), and adjunctive IVC stent (n = 3, 7.3%). Among the 14 (34.1%) patients who had intervention for IVCT, patency was restored in 12 patients (85.7%). CONCLUSIONS:IVCT is a rare event and is associated with known risk factors for venous thromboembolism. PE can occur in roughly 25% of patients presenting with IVCT. Presence of a filter does not appear to confer an advantage in preventing PE when IVCT occurs. Although majority of IVCT is managed with anticoagulation alone, endovascular interventions, including lysis and stenting, can safely restore patency in most properly selected patients.
PMID: 30982504
ISSN: 1615-5947
CID: 3807542

A systematic review of venous aneurysms by anatomic location

Teter, Katherine A; Maldonado, Thomas M; Adelman, Mark A
OBJECTIVE:Venous aneurysms are uncommon vascular abnormalities that may be identified anywhere in the body. Historically, they were often misdiagnosed as soft tissue lesions, but with the advent of readily available noninvasive imaging (such as duplex ultrasound), they can now be easily identified. Our aim was to review the presentation of venous aneurysms, available imaging modalities for defining them, and management. METHODS:The English-language literature before March 2017 was reviewed, and only reports of primary venous aneurysms of the deep veins were included. Reports were subdivided on the basis of the location of the venous aneurysm, and reports containing sample imaging studies were referenced from Elsevier publications. RESULTS:In total, our review identified reports of 35 head and neck venous aneurysms, 42 thoracic venous aneurysms, 152 intra-abdominal venous aneurysms, and 279 venous aneurysms of the extremities. Venous aneurysms of the lower extremity deep veins were most likely to be manifested by venous thromboembolic events, with approximately 25% to 50% of popliteal vein aneurysms presenting with pulmonary embolism. Diagnosis can be made by duplex ultrasound, computed tomography venography, magnetic resonance venography, or invasive venography. Management varies by location; most thoracic and head and neck aneurysms are observed, whereas venous aneurysms of the extremities are treated with surgical intervention, given the potential for venous thromboembolism. Few reports describe endovascular management of these lesions, so open surgical intervention remains the standard of care. CONCLUSIONS:Venous aneurysms are rare vascular malformations that occur throughout the body. Many are identified on routine imaging ordered for other indications, whereas venous aneurysms of the deep veins of the extremities are often manifested with venous thromboembolism. Management of these lesions is determined largely by location and the potential morbidity and mortality of the untreated aneurysms vs surgery; aneurysms of the head and neck and thorax are managed with observation and serial imaging over time, whereas those of the abdomen and extremities are treated with surgical intervention. Endovascular techniques continue to lack a defined role in their management, and the standard of care remains open repair, when indicated.
PMID: 29661366
ISSN: 2213-3348
CID: 3042682