Try a new search

Format these results:

Searched for:

in-biosketch:true

person:willim33

Total Results:

242


Membranous Septum Length Predicts New Conduction Abnormalities in Surgical Aortic Valve Replacement: A Novel Predictor for Permanent Pacemaker Implantation After Surgical Aortic Valve Replacement

Nakashima, Makoto; Jilaihawi, Hasan; He, Yuxin; Williams, David; Pushkar, Illya; Williams, Mathew; Hisamoto, Kazuhiro
INTRODUCTION/BACKGROUND:The membranous septum (MS) length measured by cardiac computed tomography (CT) is useful for the prediction of permanent pacemaker implantation (PPMI) and new left bundle branch block (LBBB) after transcatheter aortic valve replacement. However, its predictive value for patients undergoing surgical aortic valve replacement (SAVR) is unknown. METHODS:A total of 2531 consecutive patients were registered in the institutional Society of Thoracic Surgeons database between July 2017 and June 2020. Patients who underwent non-SAVR procedures, had prior pacemaker/implantable cardioverter defibrillator, prior SAVR, no preprocedural CT assessment, or suboptimal CT imaging were excluded. RESULTS:(odds ratio: 9.165; 95% confidence interval: 1.644-51.080; P = 0.011) and MS length <1.5 mm (odds ratio: 14.449; 95% confidence interval: 1.632-127.954; P = 0.016) were independent predictors for new PPMI/LBBB. CONCLUSIONS:Short MS length on preoperative cardiac CT is a powerful and novel predictor for the risk of new PPMI/LBBB after SAVR. Special care should be taken in patients with short MS length to avoid suture-mediated trauma.
PMID: 38070251
ISSN: 1095-8673
CID: 5589792

1-Year Outcomes With Fourth-Generation Mitral Valve Transcatheter Edge-to-Edge Repair From the EXPAND G4 Study

von Bardeleben, Ralph Stephan; Mahoney, Paul; Morse, M Andrew; Price, Matthew J; Denti, Paolo; Maisano, Francesco; Rogers, Jason H; Rinaldi, Michael; De Marco, Federico; Rollefson, William; Chehab, Bassem; Williams, Mathew; Leurent, Guillaume; Asch, Federico M; Rodriguez, Evelio
BACKGROUND:The fourth-generation mitral transcatheter edge-to-edge repair (M-TEER) device introduced an improved clip deployment sequence, independent leaflet grasping, and 2 wider clip sizes to tailor the treatment of patients with mitral regurgitation (MR) for a broad range of anatomies. The 30-day safety and effectiveness of the fourth-generation M-TEER device were previously demonstrated. OBJECTIVES/OBJECTIVE:The aim of this study was to evaluate 1-year outcomes in a contemporary, real-world cohort of subjects treated with the MitraClip G4 system. METHODS:EXPAND G4 is an ongoing prospective, multicenter, international, single-arm study that enrolled subjects with primary and secondary MR. One-year outcomes included MR severity (echocardiographic core laboratory assessed), heart failure hospitalization, all-cause mortality, functional capacity (NYHA functional class), and quality of life (Kansas City Cardiomyopathy Questionnaire). RESULTS:A total of 1,164 subjects underwent M-TEER from 2020 to 2022. At 1 year, there was a durable reduction in MR to mild or less in 92.6% and to none or trace in 44.2% (P < 0.0001 vs baseline). Few subjects had major adverse events through 1 year (<2% for myocardial infarction, surgical reintervention, or single-leaflet device attachment). The 1-year Kaplan-Meier estimates for all-cause mortality and heart failure hospitalization were 12.3% and 16.9%. Significant improvements in functional capacity (NYHA functional class I or II in 82%; P < 0.0001 vs baseline) and quality of life (18.5-point Kansas City Cardiomyopathy Questionnaire overall summary score improvement; P < 0.0001) were observed. CONCLUSIONS:M-TEER with the fourth-generation M-TEER device was safe and effective at 1 year, with durable reductions in MR severity to ≤1+ in more than 90% of patients and concomitant improvements in functional status and quality of life.
PMID: 37877913
ISSN: 1876-7605
CID: 5609762

Very Late Sinus of Valsalva Sequestration After Transcatheter Aortic Valve Implantation in Native Aortic Annuli [Case Report]

Ibrahim, Homam; Chaus, Adib; Staniloae, Cezar; Jilaihawi, Hasan; Vainrib, Alan; Alkhalil, Ahmad; Neuberger, Peter; Saric, Muhammad; Williams, Mathew
Coronary artery obstruction caused by sinus sequestration is well described after transcatheter aortic valve implantation in failed bioprosthetic valves, which usually occurs during or shortly after the transcatheter aortic valve implantation procedure. We report the presentation, management, and outcomes of 2 cases of very late sinus sequestration in native aortic annuli, which has not been described before to our knowledge. (Level of Difficulty: Advanced.).
PMCID:10635892
PMID: 37954954
ISSN: 2666-0849
CID: 5611082

Outcomes of SAPIEN 3 Transcatheter Aortic Valve Replacement Compared With Surgical Valve Replacement in Intermediate-Risk Patients

Madhavan, Mahesh V; Kodali, Susheel K; Thourani, Vinod H; Makkar, Raj; Mack, Michael J; Kapadia, Samir; Webb, John G; Cohen, David J; Herrmann, Howard C; Williams, Mathew; Greason, Kevin; Pibarot, Philippe; Hahn, Rebecca T; Jaber, Wael; Xu, Ke; Alu, Maria; Smith, Craig R; Leon, Martin B
BACKGROUND:Previous studies demonstrated transcatheter aortic valve replacement (TAVR) with an earlier generation balloon-expandable valve to be noninferior to surgical aortic valve replacement (SAVR) for death and disabling stroke in intermediate-risk patients with symptomatic, severe aortic stenosis at 5 years. However, limited long-term data are available with the more contemporary SAPIEN 3 (S3) bioprosthesis. OBJECTIVES:The aim of this study was to compare 5-year risk-adjusted outcomes in intermediate-risk patients undergoing S3 TAVR vs SAVR. METHODS:Propensity score matching was performed to account for baseline differences in intermediate-risk patients undergoing S3 TAVR in the PARTNER 2 (Placement of Aortic Transcatheter Valves) S3 single-arm study and SAVR in the PARTNER 2A randomized clinical trial. The primary composite endpoint consisted of 5-year all-cause death and disabling stroke. RESULTS:A total of 783 matched pairs of intermediate-risk patients with severe aortic stenosis were studied. There were no differences in the primary endpoint between S3 TAVR and SAVR at 5 years (40.2% vs 42.7%; HR: 0.87; 95% CI: 0.74-1.03; P = 0.10). The incidence of mild or greater paravalvular regurgitation was more common after S3 TAVR. There were no differences in structural valve deterioration-related stage 2 and 3 hemodynamic valve deterioration or bioprosthetic valve failure. CONCLUSIONS:In this propensity-matched analysis of intermediate-risk patients, 5-year rates of death and disabling stroke were similar between S3 TAVR and SAVR. Rates of structural valve deterioration-related hemodynamic valve deterioration were similar, but paravalvular regurgitation was more common after S3 TAVR. Longer-term follow-up is needed to further evaluate differences in late adverse clinical events and bioprosthetic valve durability. (PII S3i [PARTNER II Trial: Placement of Aortic Transcatheter Valves II - S3 Intermediate], NCT03222128; PII A (PARTNER II Trial: Placement of Aortic Transcatheter Valves II - XT Intermediate and High Risk], NCT01314313).
PMID: 37407110
ISSN: 1558-3597
CID: 5536862

Expanding the Spectrum of TEER Suitability: Evidence From the EXPAND G4 Post Approval Study

Rogers, Jason H; Asch, Federico; Sorajja, Paul; Mahoney, Paul; Price, Matthew J; Maisano, Francesco; Denti, Paolo; Morse, Michael A; Rinaldi, Michael; Bedogni, Francesco; De Marco, Federico; Rollefson, William; Chehab, Bassem; Williams, Mathew R; Leurent, Guillaume; Morikawa, Takao; Asgar, Anita W; Rodriguez, Evelio; von Bardeleben, Ralph Stephan; Kar, Saibal
BACKGROUND:Anatomical and clinical criteria to define mitral transcatheter edge-to-edge repair (TEER) "unsuitability" have been proposed on the basis of a Heart Valve Collaboratory consensus opinion from physician experience with early-generation TEER devices but lacked an evidence-based approach. OBJECTIVES:The aim of this study was to explore the spectrum of TEER suitability using echocardiographic and clinical outcomes from the EXPAND G4 real-world postapproval study. METHODS:EXPAND G4 is a global, prospective, multicenter, single-arm study that enrolled 1,164 subjects with mitral regurgitation (MR) treated with the MitraClip G4 System. Three groups were defined using the Heart Valve Collaboratory TEER unsuitability criteria: 1) risk of stenosis (RoS); 2) risk of inadequate MR reduction (RoIR); and 3) subjects with baseline moderate or less MR (MMR). A TEER-suitable (TS) group was defined by the absence of these characteristics. Endpoints included independent core laboratory-assessed echocardiographic characteristics, procedural outcomes, MR reduction, NYHA functional class, Kansas City Cardiomyopathy Questionnaire score, and major adverse events through 30 days. RESULTS:Subjects in the RoS (n = 56), RoIR (n = 54), MMR (n = 326), and TS (n = 303) groups had high 30-day MR reduction rates (≤1+: RoS 97%, MMR 93%, and TS 91%; ≤2+: RoIR 94%). Thirty-day improvements in functional capacity (NYHA functional class I or II at 30 days vs baseline: RoS 94% vs 29%, RoIR 88% vs 30%, MMR 79% vs 26%, and TS 83% vs 33%) and quality of life (change in Kansas City Cardiomyopathy Questionnaire score: RoS +27 ± 26, RoIR +16 ± 26, MMR +19 ± 26, and TS +19 ± 24) were safely achieved in all groups, with low major adverse events (<3%) and all-cause mortality (RoS 1.8%, RoIR 0%, MMR 1.5%, and TS 1.3%). CONCLUSIONS:Patients previously deemed TEER unsuitable can be safely and effectively treated with the mitral TEER fourth-generation device.
PMID: 37380229
ISSN: 1876-7605
CID: 5538662

Real-World Outcomes of Fourth-Generation Mitral Transcatheter Repair: 30-Day Results From EXPAND G4

von Bardeleben, Ralph Stephan; Rogers, Jason H; Mahoney, Paul; Price, Matthew J; Denti, Paolo; Maisano, Francesco; Rinaldi, Michael; Rollefson, William A; De Marco, Federico; Chehab, Bassem; Williams, Mathew R; Asch, Federico M; Rodriguez, Evelio
BACKGROUND:The fourth-generation MitraClip G4 System builds on the previous NTR/XTR system with additional wider clip sizes (NTW and XTW), an independent grasping feature, and an improved clip deployment sequence. OBJECTIVES:The primary objective of this study was to assess the safety and performance of the MitraClip G4 System within a contemporary real-world setting. METHODS:EXPAND G4 is a prospective, multicenter, international, single-arm, postapproval study that enrolled patients with primary (degenerative) mitral regurgitation (MR) and secondary (functional) MR at 60 centers. Follow-up of the full cohort has been conducted through 30 days. Echocardiograms were analyzed by an echocardiography core laboratory. Study outcomes included MR severity, functional capacity measured by NYHA functional class, quality of life measured using the Kansas City Cardiomyopathy Questionnaire, major adverse event rates, and all-cause mortality. RESULTS:In EXPAND G4, 1,141 subjects with primary MR and secondary MR were treated from March 2021 to February 2022. Implantation and acute procedural success rates were 98.0% and 96.2%, respectively, with a mean of 1.4 ± 0.6 clips implanted per subject. MR was significantly reduced at 30 days compared with baseline (98% achieved MR ≤ 2+, and 91% achieved MR ≤ 1+; P < 0.0001). Functional capacity and quality of life were substantially improved, with 83% of patients achieving NYHA functional class I or II. Likewise, an 18-point improvement was observed in Kansas City Cardiomyopathy Questionnaire summary scores compared with baseline. The composite major adverse event rate was 2.7%, and the all-cause death rate was 1.3% at 30 days. CONCLUSIONS:This study demonstrates for the first time the effectiveness and safety of MitraClip G4 System at 30 days in a cohort of >1,000 patients with MR in a contemporary, real-world setting.
PMID: 37380228
ISSN: 1876-7605
CID: 5538652

Economic Outcomes of Transcatheter Versus Surgical Aortic Valve Replacement in Patients with Severe Aortic Stenosis and Low Surgical Risk: Results from the PARTNER 3 Trial

Galper, Benjamin Z; Chinnakondepalli, Khaja M; Wang, Kaijun; Magnuson, Elizabeth A; Lu, Michael; Thourani, Vinod H; Kodali, Susheel; Makkar, Raj; Herrmann, Howard C; Kapadia, Samir; Williams, Mathew; Webb, John; Smith, Craig R; Mack, Michael J; Leon, Martin B; Cohen, David J
BACKGROUND:In patients with severe symptomatic aortic stenosis at low surgical risk, transfemoral transcatheter aortic valve replacement (TAVR) with the SAPIEN 3 valve has been shown to reduce the composite of death, stroke, or rehospitalization at 2-year follow-up compared with surgical aortic valve replacement (SAVR). Whether TAVR is cost-effective compared with SAVR for low-risk patients remains uncertain. METHODS:Between 2016 and 2017, 1000 low-risk patients with aortic stenosis were randomly assigned to TAVR with the SAPIEN 3 valve or SAVR in the PARTNER 3 trial (Placement of Aortic Transcatheter Valves). Of these patients, 929 underwent valve replacement, were enrolled in the United States, and were included in the economic substudy. Procedural costs were estimated using measured resource use. Other costs were determined by linkage with Medicare claims or by regression models when linkage was not feasible. Health utilities were estimated using the EuroQOL 5-item questionnaire. With the use of a Markov model informed by in-trial data, lifetime cost-effectiveness from the perspective of the US health care system was estimated in terms of cost per quality-adjusted life-year gained. RESULTS:Although procedural costs were nearly $19 000 higher with TAVR, total index hospitalization costs were only $591 more with TAVR compared with SAVR. Follow-up costs were lower with TAVR such that TAVR led to 2-year cost savings of $2030/patient compared with SAVR (95% CI, -$6222 to $1816) and a gain of 0.05 quality-adjusted life-years (95% CI, -0.003 to 0.102). In our base-case analysis, TAVR was projected to be an economically dominant strategy with a 95% probability that the incremental cost-effectiveness ratio for TAVR would be <$50 000/quality-adjusted life-year gained (consistent with high economic value from a US health care perspective). These findings were sensitive to differences in long-term survival, however, such that a modest long-term survival advantage with SAVR would render SAVR cost-effective (although not cost saving) compared with TAVR. CONCLUSIONS:For patients with severe aortic stenosis and low surgical risk similar to those enrolled in the PARTNER 3 trial, transfemoral TAVR with the SAPIEN 3 valve is cost saving compared with SAVR at 2 years and is projected to be economically attractive in the long run as long as there are no substantial differences in late death between the 2 strategies. Long-term follow-up will be critical to ultimately determine the preferred treatment strategy for low-risk patients from both a clinical and economic perspective.
PMID: 37154049
ISSN: 1524-4539
CID: 5507932

1-Year Outcomes of Transcatheter Tricuspid Valve Repair

Kodali, Susheel K; Hahn, Rebecca T; Davidson, Charles J; Narang, Akhil; Greenbaum, Adam; Gleason, Patrick; Kapadia, Samir; Miyasaka, Rhonda; Zahr, Firas; Chadderdon, Scott; Smith, Robert L; Grayburn, Paul; Kipperman, Robert M; Marcoff, Leo; Whisenant, Brian; Gonzales, Mike; Makkar, Raj; Makar, Moody; O'Neill, William; Wang, Dee Dee; Gray, William A; Abramson, Sandra; Hermiller, James; Mitchel, Lucas; Lim, D Scott; Fowler, Dale; Williams, Mathew; Pislaru, Sorin V; Dahou, Abdellaziz; Mack, Michael J; Leon, Martin B; Eleid, Mackram F
BACKGROUND:Surgical management of isolated tricuspid regurgitation (TR) is associated with high morbidity and mortality, thereby creating a significant need for a lower-risk transcatheter solution. OBJECTIVES:The single-arm, multicenter, prospective CLASP TR (Edwards PASCAL TrAnScatheter Valve RePair System in Tricuspid Regurgitation [CLASP TR] Early Feasibility Study) evaluated 1-year outcomes of the PASCAL transcatheter valve repair system (Edwards Lifesciences) to treat TR. METHODS:Study inclusion required a previous diagnosis of severe or greater TR and persistent symptoms despite medical treatment. An independent core laboratory evaluated echocardiographic results, and a clinical events committee adjudicated major adverse events. The study evaluated primary safety and performance outcomes, with echocardiographic, clinical, and functional endpoints. Study investigators report 1-year all-cause mortality and heart failure hospitalization rates. RESULTS:Sixty-five patients were enrolled: mean age of 77.4 years; 55.4% female; and 97.0% with severe to torrential TR. At 30 days, cardiovascular mortality was 3.1%, the stroke rate was 1.5%, and no device-related reinterventions were reported. Between 30 days and 1 year, there were an additional 3 cardiovascular deaths (4.8%), 2 strokes (3.2%), and 1 unplanned or emergency reintervention (1.6%). One-year postprocedure, TR severity significantly reduced (P < 0.001), with 31 of 36 (86.0%) patients achieving moderate or less TR; 100% had at least 1 TR grade reduction. Freedom from all-cause mortality and heart failure hospitalization by Kaplan-Meier analyses were 87.9% and 78.5%, respectively. Their New York Heart Association functional class significantly improved (P < 0.001) with 92% in class I or II, 6-minute walk distance increased by 94 m (P = 0.014), and overall Kansas City Cardiomyopathy Questionnaire scores improved by 18 points (P < 0.001). CONCLUSIONS:The PASCAL system demonstrated low complication and high survival rates, with significant and sustained improvements in TR, functional status, and quality of life at 1 year. (Edwards PASCAL TrAnScatheter Valve RePair System in Tricuspid Regurgitation [CLASP TR] Early Feasibility Study [CLASP TR EFS]; NCT03745313).
PMID: 37137586
ISSN: 1558-3597
CID: 5509092

Contemporary Outcomes Following Transcatheter Edge-to-Edge Repair: 1-Year Results From the EXPAND Study

Kar, Saibal; von Bardeleben, Ralph Stephan; Rottbauer, Wolfgang; Mahoney, Paul; Price, Matthew J; Grasso, Carmelo; Williams, Mathew; Lurz, Philipp; Ahmed, Mustafa; Hausleiter, Jörg; Chehab, Bassem; Zamorano, Jose L; Asch, Federico M; Maisano, Francesco
BACKGROUND:The third-generation MitraClip NTR/XTR transcatheter edge-to-edge repair system was introduced to assist in leaflet grasping with the longer clip arms of MitraClip XTR and to improve ease of use with the modified delivery catheter. OBJECTIVES/OBJECTIVE:The EXPAND study evaluated contemporary real-world outcomes in subjects with mitral regurgitation (MR) treated with the third-generation MitraClip NTR/XTR transcatheter edge-to-edge repair system. METHODS:EXPAND is a prospective, multicenter, international, single-arm study that enrolled patients with primary MR and secondary MR at 57 centers. Follow-up was conducted through 12 months. Echocardiograms were analyzed by an echocardiographic core laboratories. Study outcomes included: MR severity, functional capacity measured by New York Heart Association functional class, quality of life measured by Kansas City Cardiomyopathy Questionnaire, heart failure hospitalizations, all-cause mortality. RESULTS:1,041 patients were enrolled from April 2018 through March 2019, of which 50.5% had primary or mixed etiology. Implant success was 98.9%; 1.5 ± 0.6 clips were implanted per subject. Significant MR reduction from baseline (≥MR 3+: 56.0%) to 30 days (≤MR 1+:88.8%) was maintained through 1 year (MR ≤1+: 89.2%). A total of 84.5% and 93.0% of subjects in primary MR and secondary MR, respectively, had ≤1+ MR at 1 year. Significant improvements were observed in clinical outcomes (New York Heart Association functional class I/II in 80.3%, +21.6 improvement in Kansas City Cardiomyopathy Questionnaire score) at 1 year. All-cause mortality and heart failure hospitalizations at 1 year were 14.9% and 18.9%, respectively, which was significantly lower than previous studies. CONCLUSIONS:The study demonstrates treatment with the third-generation system resulted in substantial reduction of MR in a contemporary real-world practice, compared with the results of earlier EVEREST and COAPT trials.(The MitraClip® EXPAND Study of the Next Generation of MitraClip® Devices [EXPAND]; NCT03502811).
PMID: 36922046
ISSN: 1876-7605
CID: 5448922

Transesophageal Echocardiographic Screening for Structural Heart Interventions

Ro, Richard; Bamira, Daniel; Bernard, Samuel; Vainrib, Alan; Ibrahim, Homam; Staniloae, Cezar; Williams, Mathew R; Saric, Muhamed
PURPOSE OF REVIEW/OBJECTIVE:Percutaneous structural interventions have provided patients with an effective therapeutic option, and its growth has been aided by echocardiography. We describe the vital role that transesophageal echocardiography (TEE) plays in screening patients prior to their procedure. RECENT FINDINGS/RESULTS:A multimodality imaging approach is employed by the valve team, but TEE plays a unique role in diagnosis and planning. Utilization of all TEE views and features such as biplane, 3D imaging, and multiplanar reconstruction ensures accurate assessment of the structural lesion of interest. The role of TEE remains essential in the planning of structural interventions, and these studies should be performed in a systematic and comprehensive manner.
PMID: 36680732
ISSN: 1534-3170
CID: 5405192