Searched for: in-biosketch:true
person:cecchf01
Relation of right ventricular pacing in tetralogy of Fallot to electrical resynchronization
Stephenson, Elizabeth A; Cecchin, Frank; Alexander, Mark E; Triedman, John K; Walsh, Edward P; Berul, Charles I
Prolonged QRS duration is a marker of increased sudden death risk in tetralogy of Fallot. Right ventricular pacing increased QRS duration in this population and could be counteracted with optimization of the atrioventricular interval in a subset of patients, potentially offering right ventricular resynchronization in patients with baseline right bundle branch block. Effective pacing therapy may require site-specific placement of pacing leads and precise pacemaker programming.
PMID: 15165940
ISSN: 0002-9149
CID: 497902
Ablation of atrioventricular nodal reentrant tachycardia in tricuspid atresia [Case Report]
Khairy, Paul; Seslar, Stephen P; Triedman, John K; Cecchin, Frank
A 31-year-old woman with tricuspid atresia and a palliative Waterston shunt presented with intractable poorly tolerated supraventricular tachycardia. Electrophysiologic evaluation was consistent with AV nodal reentrant tachycardia. The fast pathway region was mapped electroanatomically during tachycardia and with constant rate ventricular pacing. Successful radiofrequency ablation was achieved by placement of lesions in an area adjacent and inferior to the His-bundle electrogram on the left side of the septum.
PMID: 15175070
ISSN: 1045-3873
CID: 497912
Recent advances in pacemaker and implantable defibrillator therapy for young patients
Walsh, Edward P; Cecchin, Frank
PURPOSE OF REVIEW: This review is intended to highlight major clinical advances over the past year related to (1). biventricular pacing as a treatment for dilated myopathy, (2). growing clinical experience with implantable cardioverter defibrillators in pediatrics, (3). technical advances in standard antibradycardia pacing, and (4). an appraisal of the newly updated ACC/AHA/NASPE guidelines for device implant in children and adolescents. RECENT FINDINGS: Complex rhythm devices are being used more frequently in children. Biventricular pacing to improve ventricular contractility is a rapidly evolving technology that has now been applied to children and young adults with intraventricular conduction delay, such as bundle branch block after cardiac surgery. Implantable defibrillators are also being used for an expanding list of conditions, although lead dysfunction is seen as a fairly common complication in active young patients. Guidelines for device implantation have been developed, but the weight of evidence remains somewhat limited by the paucity of pediatric data in this field. SUMMARY: Thanks to refinements in lead design and generator technology, coupled with rapidly expanding clinical indications, pacemakers and implantable defibrillators have become increasingly important components of cardiac therapy for young patients. Expanded multicenter clinical studies will be needed to develop more objective guidelines for use of this advanced technology.
PMID: 15075732
ISSN: 0268-4705
CID: 497922
Implications of implantable cardioverter defibrillator therapy in congenital heart disease and pediatrics
Alexander, Mark E; Cecchin, Frank; Walsh, Edward P; Triedman, John K; Bevilacqua, Laura M; Berul, Charles I
INTRODUCTION: The incidence of appropriate and inappropriate discharges, indicators of system failure, and clinical implications of implantable cardioverter defibrillator (ICD) therapy in children and young adults with heart disease is poorly defined. METHODS AND RESULTS: In a retrospective study at a single medical center, a total of 90 ICD procedures were performed in 76 patients younger than age 30 years (median 16 years, range 1-30): 42% with congenital heart disease, 33% with primary electrical disease, 17% with hypertrophic cardiomyopathy, and 8% with idiopathic dilated cardiomyopathy. Indications for ICD included arrest or sustained ventricular tachycardia (n = 27), and combinations of syncope (n = 32), palpitations (n = 17), spontaneous ventricular arrhythmia (n = 40), inducible ventricular tachycardia (n = 36), or severe hypertrophic cardiomyopathy. Transvenous dual-chamber ICDs were implanted in 29 patients. Subcutaneous arrays or epicardial patches were used in 9 patients. Over a median 2-year follow-up, 28% of patients received appropriate shocks for ventricular tachycardia (median 13 months to first shock) and 25% experienced inappropriate shocks for multiple causes (median 16 months). With multivariate analysis, growth strongly correlated with lead failure (odds ratio 73, 3.5-1530, P = 0.006). Complications occurred in 29 patients, including lead failure in 16 (21%), ICD "storm" with sequential shocks in 5, and infection in 2 patients. No deaths were attributable to ICD placement or subsequent device failure. CONCLUSION: ICD therapy can effectively manage malignant arrhythmias in selected pediatric and congenital heart patients. Spurious shocks or ICD storm may increase morbidity and emphasize the need for concomitant medical and ablative therapy. ICD lead failure was relatively frequent in this population.
PMID: 15028076
ISSN: 1045-3873
CID: 497932
Indications and techniques of pediatric cardiac pacing [Guideline]
Berul, Charles I; Cecchin, Frank
There are special challenges associated with the use of transvenous pacemakers in children. For example, a child's chest cavity or vascular dimensions could be too small to host the generator and leads available or required. If leads are implanted, they may stretch as the child grows. This increases the risk that the leads will later dislodge or fracture. Moreover, children requiring pacemakers often have coexisting congenital heart defects and the structural abnormalities of those could hinder easy placement of the pacing system. This article will first review the indications for permanent pacing in children and will then describe the unique challenges associated with such use.
PMID: 15030277
ISSN: 1477-9072
CID: 497942
Circadian and seasonal variation of malignant arrhythmias in a pediatric and congenital heart disease population
Stephenson, Elizabeth A; Collins, Kathryn K; Dubin, Anne M; Epstein, Michael R; Hamilton, Robert M; Kertesz, Naomi J; Alexander, Mark E; Cecchin, Frank; Triedman, John K; Walsh, Edward P; Berul, Charles I
INTRODUCTION: Recent studies in adult populations have revealed seasonal variation in the frequency of acute cardiovascular events, including life-threatening arrhythmias, demonstrating increased events during winter and early spring. Trends in the time of day that arrhythmias occur also were noted. We sought to establish whether pediatric and young adult congenital heart disease implantable cardioverter defibrillator (ICD) recipients have circadian or seasonal variability in shock frequency, similar to adult populations. METHODS AND RESULTS: Data from ICD patients at six pediatric centers in North America were analyzed to assess the timing of life-threatening arrhythmias. The populations consisted of children and adults with congenital heart disease and ICDs placed for malignant arrhythmias. Data were considered in 46 patients who received appropriate therapy (total 139 episodes) for ventricular tachycardia or ventricular fibrillation. Multiple variables were analyzed, including time of day, day of week, and month of year. In contrast to previously studied adult patients, fewer events occurred in the early morning (7.5%), with the most therapies occurring between 6 P.M. and midnight (35%). An increased frequency of therapies was observed in the fall and winter (September-January), representing 60% of all appropriate shocks. Unlike adult populations, Mondays did not have an increased frequency of malignant arrhythmias. CONCLUSION: Pediatric and adult congenital heart disease populations have moderate seasonal and 24-hour variation in ICD event rate, with some distinctly different peaks than those seen in typical adult ICD populations. These findings suggest circadian variation in arrhythmia vulnerability that may differ from conventional occupational, physical, or emotional stressors. (J Cardiovasc Electrophysiol, Vol. 13, pp.
PMID: 12435187
ISSN: 1045-3873
CID: 497952
Atrioventricular nodal reentrant tachycardia in children: effect of slow pathway ablation on fast pathway function
Van Hare, George F; Chiesa, Nancy A; Campbell, Robert M; Kanter, Ronald J; Cecchin, Frank
INTRODUCTION: Prior studies in adults have shown significant shortening of the fast pathway effective refractory period after successful slow pathway ablation. As differences between adults and children exist in other characteristics of AV nodal reentrant tachycardia (AVNRT), we sought to characterize the effect of slow pathway ablation or modification in a multicenter study of pediatric patients. METHODS AND RESULTS: Data from procedures in pediatric patients were gathered retrospectively from five institutions. Entry criteria were age <21 years, typical AVNRT inducible with/without isoproterenol infusion, and attempted slow pathway ablation or modification. Dual AV nodal pathways were defined as those with > or =50 msec jump in A2-H2 with a 10-msec decrease in A1-A2. Successful ablation was defined as elimination of AVNRT inducibility. A total of 159 patients (age 4.4 to 21 years, mean 13.1) were studied and had attempted slow pathway ablation. AVNRT was inducible in the baseline state in 74 (47%) of 159 patients and with isoproterenol in the remainder. Dual AV nodal pathways were noted in 98 (62%) of 159 patients in the baseline state. Ablation was successful in 154 (97%) of 159 patients. In patients with dual AV nodal pathways and successful slow pathway ablation, the mean fast pathway effective refractory period was 343+/-68 msec before ablation and 263+/-64 msec after ablation. Mean decrease in the fast pathway effective refractory period was 81+/-82 msec (P < 0.0001) and was not explained by changes in autonomic tone, as measured by changes in sinus cycle length during the ablation procedure. Electrophysiologic measurements were correlated with age. Fast pathway effective refractory period was related to age both before (P = 0.0044) and after ablation (P < 0.0001). AV block cycle length was related to age both before (P = 0.0005) and after ablation (P < 0.0001). However, in dual AV nodal pathway patients, the magnitude of change in the fast pathway effective refractory period after ablation was not related to age. CONCLUSION: Lack of clear dual AV node physiology is common in pediatric patients with inducible AVNRT (38%). Fast pathway effective refractory period shortens substantially in response to slow pathway ablation. The magnitude of change is large compared with adult reports and is not completely explained by changes in autonomic tone. Prospective studies in children using autonomic blockade are needed.
PMID: 11942583
ISSN: 1045-3873
CID: 497962
Is arrhythmia detection by automatic external defibrillator accurate for children?: sensitivity and specificity of an automatic external defibrillator algorithm in 696 pediatric arrhythmias
Cecchin, F; Jorgenson, D B; Berul, C I; Perry, J C; Zimmerman, A A; Duncan, B W; Lupinetti, F M; Snyder, D; Lyster, T D; Rosenthal, G L; Cross, B; Atkins, D L
BACKGROUND: Use of automatic external defibrillators (AEDs) in children aged <8 years is not recommended. The purpose of this study was to develop an ECG database of shockable and nonshockable rhythms from a broad age range of pediatric patients and to test the accuracy of the Agilent Heartstream FR2 Patient Analysis System for sensitivity and specificity. METHODS AND RESULTS: Children aged =12 years who either developed arrhythmias or were at risk for developing arrhythmias were studied. Two sources were used for the database: children whose rhythms were recorded prospectively via a modified AED and children who had arrhythmias captured on paper and digitized for subsequent analysis. The rhythms were divided into 5-second strips, classified by 3 reviewers, and then assessed by the AED analysis algorithm. A total of 696 five-second rhythm strips from 191 children (81 female and 110 male) aged 1 day to 12 years (median 3.0 years) were analyzed. There was 100% specificity for nonshockable rhythms. Sensitivity for ventricular fibrillation was 96%. CONCLUSIONS: There was excellent AED rhythm analysis sensitivity and specificity in all age groups for ventricular fibrillation and nonshockable rhythms. The high specificity and sensitivity indicate that there is a very low risk of an inappropriate shock and that the AED correctly identifies shockable rhythms, making the algorithm both safe and effective for children.
PMID: 11369689
ISSN: 1524-4539
CID: 1878482
Congenital heart block: development of late-onset cardiomyopathy, a previously underappreciated sequela
Moak, J P; Barron, K S; Hougen, T J; Wiles, H B; Balaji, S; Sreeram, N; Cohen, M H; Nordenberg, A; Van Hare, G F; Friedman, R A; Perez, M; Cecchin, F; Schneider, D S; Nehgme, R A; Buyon, J P
OBJECTIVE: We report 16 infants with complete congenital heart block (CHB) who developed late-onset dilated cardiomyopathy despite early institution of cardiac pacing. BACKGROUND: Isolated CHB has an excellent prognosis following pacemaker implantation. Most early deaths result from delayed initiation of pacing therapy or hemodynamic abnormalities associated with congenital heart defects. METHODS: A multi-institutional study was performed to identify common clinical features and possible risk factors associated with late-onset dilated cardiomyopathy in patients born with congenital CHB. RESULTS: Congenital heart block was diagnosed in utero in 12 patients and at birth in four patients. Ten of 16 patients had serologic findings consistent with neonatal lupus syndrome (NLS). A pericardial effusion was evident on fetal ultrasound in six patients. In utero determination of left ventricular (LV) function was normal in all. Following birth, one infant exhibited a rash consistent with NLS and two had elevated hepatic transaminases and transient thrombocytopenia. In the early postnatal period, LV function was normal in 15 patients (shortening fraction [SF] = 34 +/- 7%) and was decreased in one (SF = 20%). A cardiac pacemaker was implanted during the first two weeks of life in 15 patients and at seven months in one patient. Left ventricular function significantly decreased during follow-up (14 days to 9.3 years, SF = 9% +/- 5%). Twelve of 16 patients developed congestive heart failure before age 24 months. Myocardial biopsy revealed hypertrophy in 11 patients, interstitial fibrosis in 11 patients, and myocyte degeneration in two patients. Clinical status during follow-up was guarded: four patients died from congestive heart failure; seven required cardiac transplantation; one was awaiting cardiac transplantation; and four exhibited recovery of SF (31 +/- 2%). CONCLUSIONS: Despite early institution of cardiac pacing, some infants with CHB develop LV cardiomyopathy. Patients with CHB require close follow-up not only of their cardiac rate and rhythm, but also ventricular function
PMID: 11153745
ISSN: 0735-1097
CID: 73547