Try a new search

Format these results:

Searched for:

in-biosketch:true

person:daneb01

Total Results:

112


Automated Radiology-Pathology Module Correlation Using a Novel Report Matching Algorithm by Organ System

Dane, Bari; Doshi, Ankur; Gfytopoulos, Soterios; Bhattacharji, Priya; Recht, Michael; Moore, William
OBJECTIVES AND RATIONALE/UNASSIGNED:Radiology-pathology correlation is time-consuming and is not feasible in most clinical settings, with the notable exception of breast imaging. The purpose of this study was to determine if an automated radiology-pathology report pairing system could accurately match radiology and pathology reports, thus creating a feedback loop allowing for more frequent and timely radiology-pathology correlation. METHODS:An experienced radiologist created a matching matrix of radiology and pathology reports. These matching rules were then exported to a novel comprehensive radiology-pathology module. All distinct radiology-pathology pairings at our institution from January 1, 2016 to July 1, 2016 were included (n = 8999). The appropriateness of each radiology-pathology report pairing was scored as either "correlative" or "non-correlative." Pathology reports relating to anatomy imaged in the specific imaging study were deemed correlative, whereas pathology reports describing anatomy not imaged with the particular study were denoted non-correlative. RESULTS:Overall, there was 88.3% correlation (accuracy) of the radiology and pathology reports (n = 8999). Subset analysis demonstrated that computed tomography (CT) abdomen/pelvis, CT head/neck/face, CT chest, musculoskeletal CT (excluding spine), mammography, magnetic resonance imaging (MRI) abdomen/pelvis, MRI brain, musculoskeletal MRI (excluding spine), breast MRI, positron emission tomography (PET), breast ultrasound, and head/neck ultrasound all demonstrated greater than 91% correlation. When further stratified by imaging modality, CT, MRI, mammography, and PET demonstrated excellent correlation (greater than 96.3%). Ultrasound and non-PET nuclear medicine studies demonstrated poorer correlation (80%). CONCLUSION/CONCLUSIONS:There is excellent correlation of radiology imaging reports and appropriate pathology reports when matched by organ system. Rapid, appropriate radiology-pathology report pairings provide an excellent opportunity to close feedback loop to the interpreting radiologist.
PMID: 29373209
ISSN: 1878-4046
CID: 2929142

Automated image quality evaluation of T2 -weighted liver MRI utilizing deep learning architecture

Esses, Steven J; Lu, Xiaoguang; Zhao, Tiejun; Shanbhogue, Krishna; Dane, Bari; Bruno, Mary; Chandarana, Hersh
PURPOSE: To develop and test a deep learning approach named Convolutional Neural Network (CNN) for automated screening of T2 -weighted (T2 WI) liver acquisitions for nondiagnostic images, and compare this automated approach to evaluation by two radiologists. MATERIALS AND METHODS: We evaluated 522 liver magnetic resonance imaging (MRI) exams performed at 1.5T and 3T at our institution between November 2014 and May 2016 for CNN training and validation. The CNN consisted of an input layer, convolutional layer, fully connected layer, and output layer. 351 T2 WI were anonymized for training. Each case was annotated with a label of being diagnostic or nondiagnostic for detecting lesions and assessing liver morphology. Another independently collected 171 cases were sequestered for a blind test. These 171 T2 WI were assessed independently by two radiologists and annotated as being diagnostic or nondiagnostic. These 171 T2 WI were presented to the CNN algorithm and image quality (IQ) output of the algorithm was compared to that of two radiologists. RESULTS: There was concordance in IQ label between Reader 1 and CNN in 79% of cases and between Reader 2 and CNN in 73%. The sensitivity and the specificity of the CNN algorithm in identifying nondiagnostic IQ was 67% and 81% with respect to Reader 1 and 47% and 80% with respect to Reader 2. The negative predictive value of the algorithm for identifying nondiagnostic IQ was 94% and 86% (relative to Readers 1 and 2). CONCLUSION: We demonstrate a CNN algorithm that yields a high negative predictive value when screening for nondiagnostic T2 WI of the liver. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2017.
PMID: 28577329
ISSN: 1522-2586
CID: 2591922

Lepidic Predominant Pulmonary Lesions (LPL): CT-based Distinction From More Invasive Adenocarcinomas Using 3D Volumetric Density and First-order CT Texture Analysis

Alpert, Jeffrey B; Rusinek, Henry; Ko, Jane P; Dane, Bari; Pass, Harvey I; Crawford, Bernard K; Rapkiewicz, Amy; Naidich, David P
RATIONALE AND OBJECTIVES: This study aimed to differentiate pathologically defined lepidic predominant lesions (LPL) from more invasive adenocarcinomas (INV) using three-dimensional (3D) volumetric density and first-order texture histogram analysis of surgically excised stage 1 lung adenocarcinomas. MATERIALS AND METHODS: This retrospective study was institutional review board approved and Health Insurance Portability and Accountability Act compliant. Sixty-four cases of pathologically proven stage 1 lung adenocarcinoma surgically resected between September 2006 and October 2015, including LPL (n = 43) and INV (n = 21), were evaluated using high-resolution computed tomography. Quantitative measurements included nodule volume, percent solid volume (% solid), and first-order texture histogram analysis including skewness, kurtosis, entropy, and mean nodule attenuation within each histogram quartile. Binomial logistic regression models were used to identify the best set of parameters distinguishing LPL from INV. RESULTS: Univariate analysis of 3D volumetric density and histogram features was statistically significant between LPL and INV groups (P < .05). Accuracy of a binomial logistic model to discriminate LPL from INV based on size and % solid was 85.9%. With optimized probability cutoff, the model achieves 81% sensitivity, 76.7% specificity, and area under the receiver operating characteristic curve of 0.897 (95% confidence interval, 0.821-0.973). An additional model based on size and mean nodule attenuation of the third quartile (Hu_Q3) of the histogram achieved similar accuracy of 81.3% and area under the receiver operating characteristic curve of 0.877 (95% confidence interval, 0.790-0.964). CONCLUSIONS: Both 3D volumetric density and first-order texture analysis of stage 1 lung adenocarcinoma allow differentiation of LPL from more invasive adenocarcinoma with overall accuracy of 85.9%-81.3%, based on multivariate analyses of either size and % solid or size and Hu_Q3, respectively.
PMID: 28844845
ISSN: 1878-4046
CID: 2679872

Utility of CT Findings in the Diagnosis of Cecal Volvulus

Dane, Bari; Hindman, Nicole; Johnson, Evan; Rosenkrantz, Andrew B
OBJECTIVE: The objective of our study was to assess the utility of CT features in the diagnosis of cecal volvulus. MATERIALS AND METHODS: Forty-three patients undergoing CT for cecal volvulus and with surgical or clinical follow-up were included. Two radiologists (11 years and 1 year of experience) evaluated CT examinations for the following: whirl sign, abnormal cecal position, "bird beak" sign, severe cecal distention, mesenteric engorgement, a newly described "central appendix" sign (defined as abnormal appendix position near midline), and overall impression for cecal volvulus. Univariable and multivariable assessments were performed. Patients with CT examinations in which the appendix was not visible were excluded from calculations involving the central appendix sign. RESULTS: Fifty-one percent (n = 22) of patients had cecal volvulus. All CT findings were significantly more common in patients with cecal volvulus (p < 0.01) other than mesenteric engorgement for reader 1 (p = 0.332). Readers 1 and 2 identified the central appendix sign in 92.9% and 92.3% of patients with volvulus versus in 37.5 and 31.1% of patients without volvulus. The whirl sign exhibited a sensitivity for cecal volvulus of 90.9% for reader 1 and 95.5% for reader 2, and a specificity of 61.9% for both readers. Abnormal cecal position exhibited a sensitivity of 90.0% for reader 1 and 100.0% for reader 2 and a specificity of 66.7% and 38.1%. The bird beak sign exhibited a sensitivity of 86.4% for reader 1 and 100.0% for reader 2 and a specificity of 85.7% and 71.4%. Severe cecal distention exhibited a sensitivity of 100.0% for both readers and a specificity of 81.0% and 61.9%. Mesenteric engorgement exhibited a sensitivity of 40.9% for reader 1 and 100.0% for reader 2 and a specificity of 76.2% and 71.4%. The central appendix sign exhibited a sensitivity of 92.9% for reader 1 and 92.3% for reader 2 and a specificity of 62.5% and 68.8%. Overall impression exhibited a sensitivity of 100.0% for both readers and a specificity of 76.2% and 57.1%. At multivariable analysis, the AUC for cecal volvulus ranged from 0.787 to 0.931, and the whirl sign was an independent predictor of volvulus for both readers (p
PMID: 28777650
ISSN: 1546-3141
CID: 2656002

Imaging Genitourinary Trauma

Dane, Bari; Baxter, Alexander B; Bernstein, Mark P
Contrast-enhanced multidetector computed tomography (MDCT) has become a critical tool in the evaluation of the trauma patient. MDCT can quickly and accurately assess trauma patients for renal, ureteral, and bladder injuries. Moreover, CT guides clinical management triaging patients to those requiring discharge, observation, angioembolization, and surgery. Recognition of urinary tract trauma on initial scan acquisition should prompt delayed excretory phase imaging to identify urine leaks. Urethral and testicular trauma are imaged with retrograde urethrography and sonography, respectively.
PMID: 28126218
ISSN: 1557-8275
CID: 2418682

Multidetector Computed Tomography Evaluation of Mesenteric Venous Thrombosis Following Laparoscopic Bariatric Surgery

Dane, Bari; Clark, Jaclyn; Megibow, Alec
OBJECTIVE: The purpose of this study is to review multidetector computed tomography (CT) imaging findings of mesenteric venous thrombosis occurring following bariatric surgery. To our knowledge, this complication has not been described in the radiologic literature. METHODS: Multidetector CT examinations of 6 patients known to have developed mesenteric venous thrombosis after laparoscopic bariatric surgery were reviewed. The thrombus was characterized, and associated imaging findings including presence of mesenteric edema, small bowel edema, and thrombotic complications were described. RESULTS: Four patients underwent laparoscopic sleeve gastrectomy approximately 12 days before CT diagnosis of mesenteric thrombosis and 2 patients had a laparoscopic Roux-en-Y gastric bypass approximately 11 years before imaging diagnosis of mesenteric thrombosis.The thrombus occupied the entire length of the superior mesenteric vein in all cases. Extension into jejunal branches was present in 4 cases. The thrombus was completely occlusive in 4 of 6 patients. CONCLUSIONS: Mesenteric venous thrombosis is an increasingly recognized complication of laparoscopic bariatric surgery. Awareness demands that postbariatric surgery patients with acute abdominal pain be studied with intravenous contrast material.
PMID: 27680412
ISSN: 1532-3145
CID: 2262632

Imaging of Spine Trauma

Dane, Bari; Bernstein, Mark P
PMID: 27287950
ISSN: 1558-4658
CID: 2136672

PET/CT vs. non-contrast CT alone for surveillance 1-year post lobectomy for stage I non-small-cell lung cancer

Dane, Bari; Grechushkin, Vadim; Plank, April; Moore, William; Bilfinger, Thomas
(18)F-FDG PET/CT was compared with non-contrast chest CT in monitoring for recurrence 1-year after lobectomy of stage 1 non-small-cell lung cancer (NSCLC). For surveillance after treatment with curative intent, current (April 2012) National Comprehensive Cancer network guidelines recommend chest CT with or without contrast every 6-12 months for 2 years, then non-contrast chest CT annually. PET/CT is not currently indicated for routine follow-up. One hundred patients receiving surveillance PET/CT 1-year after lobectomy for the treatment of stage 1a or 1b NSCLC were included in the study. Exclusion criteria included the presence or interval diagnosis of a second malignancy, or surgical treatment more radical than single lobectomy. The non-contrast CT obtained from the 1-year PET/CT was interpreted by an experienced chest radiologist blinded to the PET/CT for evidence of recurrence using the following findings: pulmonary nodule, pleural effusion, pleural mass, adenopathy, and extrathoracic mass. The ecision about recurrence was made solely from the non-contrast CT without PET/CT findings. This was compared with the determination made with PET/CT. The reference standard for determination of recurrence was the multi-disciplinary tumor board who had access to all imaging and clinical data. Recurrence at 1 year was documented in 16 of 90 patients. All 16 recurrences were documented with PET/CT and 9 were found with non-contrast CT. Five of the 7 recurrences missed with non-contrast CT were extrathoracic metastases. Sensitivity of CT and PET/CT for recurrence was 56.3% and 100%, respectively (p = 0.015). Specificity of CT and PET/CT for recurrence was 95.9% and 93.2%, respectively (p = 0.62).
PMCID:3784804
PMID: 24116349
ISSN: 2160-8407
CID: 1057262

Ureteral rupture from aberrant Foley catheter placement: a case report [Case Report]

Baker, Kevin S; Dane, Bari; Edelstein, Yudell; Malhotra, Ajay; Gould, Elaine
We present the case of a 59 year old female with history of severe neurologic dysfunction from advanced multiple sclerosis who presented with lethargy and oliguria several hours after urethral Foley catheterization. A contrast-enhanced CT scan of the abdomen/pelvis showed an aberrantly placed Foley catheter with its balloon inflated in the proximal left ureter, a rare complication of Foley catheterization with only 5 other cases reported. Incomplete ureteral rupture was demonstrated and confirmed by a followup CT scan in the urographic phase. One of our institution's Interventional Radiologists then placed a nephroureteral stent across the injured ureter to facilitate healing. The patient expired 9 days after the procedure from unrelated sepsis from a chronic stage IV decubitus ulcer, so long term monitoring could not be performed. Following description of our case, we conduct a literature review of presentations, imaging characteristics, and treatment of ureteral Foley catheter placement.
PMCID:3557132
PMID: 23372873
ISSN: 1943-0922
CID: 1057272

Interleaved carbon minibeams: an experimental radiosurgery method with clinical potential

Dilmanian, F Avraham; Rusek, Adam; Fois, Giovanna R; Olschowka, John; Desnoyers, Nicolle R; Park, Jane Y; Dioszegi, Istvan; Dane, Bari; Wang, Ruiliang; Tomasi, Dardo; Lee, Hedok; Hurley, Sean D; Coyle, Patricia K; Meek, Allen G; O'Banion, M Kerry
PURPOSE: To evaluate the efficacy of "interleaved carbon minibeams" for ablating a 6.5-mm target in a rabbit brain with little damage to the surrounding brain. The method is based on the well-established tissue-sparing effect of arrays of thin planes of radiation. METHODS AND MATERIALS: Broad carbon beams from the National Aeronautics and Space Agency Space Radiation Facility at Brookhaven National Laboratory were segmented into arrays of parallel, horizontal, 0.3-mm-thick planar beams (minibeams). The minibeams' gradual broadening in tissues resulted in 0.525-mm beam thickness at the target's proximal side in the spread-out Bragg peak. Interleaving was therefore implemented by choosing a 1.05 mm beam spacing on-center. The anesthetized rabbit, positioned vertically on a stage capable of rotating about a vertical axis, was exposed to arrays from four 90 degrees angles, with the stage moving up by 0.525 mm in between. This produced a solid radiation field at the target while exposing the nontargeted tissues to single minibeam arrays. The target "physical" absorbed dose was 40.2 Gy. RESULTS: The rabbit behaved normally during the 6-month observation period. Contrast magnetic resonance imaging and hematoxylin and eosin histology at 6 months showed substantial focal target damage with little damage to the surrounding brain. CONCLUSION: We plan to evaluate the method's therapeutic efficacy by comparing it with broad-beam carbon therapy in animal models. The method's merits would combine those of carbon therapy (i.e., tight target dose because of the carbon's Bragg-peak, sharp dose falloff, and high relative biological effectiveness at the target), together with the method's low impact on the nontargeted tissues. The method's smaller impact on the nontargeted brain might allow carbon therapy at higher target doses and/or lower normal tissue impact, thus leading to a more effective treatment of radioresistant tumors. It should also make the method more amenable to administration in either a single dose fraction or in a small number of fractions.
PMID: 22342299
ISSN: 0360-3016
CID: 1057282