Try a new search

Format these results:

Searched for:

in-biosketch:true

person:ag1812

Total Results:

181


Transfusion Thresholds Can Be Safely Lowered in the Hip Fracture Patient: A Consecutive Series of 1,496 Patients

Konda, Sanjit R; Parola, Rown; Perskin, Cody R; Fisher, Nina D; Ganta, Abhishek; Egol, Kenneth A
INTRODUCTION/BACKGROUND:The purpose of this study is to identify optimal threshold hemoglobin (Hgb) and hematocrit (Hct) laboratory values to transfuse hip fracture patients. METHODS:A consecutive series of hip fracture patients were reviewed for demographic, clinical, and cost data. Patients receiving an allogeneic transfusion of packed red blood cells (pRBCs) were grouped based on last Hct or Hgb (H&H) value before first transfusion. Multivariate logistic regressions of H&H quantile were performed to predict "good outcomes," a composite binary variable defined as admissions satisfying (1) no major complications, (2) length of stay below top tertile, (3) cost below median, (4) no mortality within 30 days, and (5) no readmission within 30 days. Odds ratios (OR) for "good outcomes" were calculated for each H&H quantile. RESULTS:One thousand four hundred ninety-six hip fracture patients were identified, of which 598 (40.0%) were transfused with pRBCs. Patients first transfused at Hgb values from 7.55 to 7.85 g/dL (P = 0.043, OR = 2.70) or Hct values from 22.7 to 23.8% (P = 0.048, OR = 2.63) were most likely to achieve "good outcomes." DISCUSSION/CONCLUSIONS:The decision to transfuse patients should be motivated by Hgb and Hct laboratory test results, given that transfusion timing relative to surgery has been shown to not affect outcomes among patients matched by trauma risk score. Surgeons should aim to transfuse hip fracture patients at Hgb levels between 7.55 g/dL and 7.85 g/dL or Hct levels between 22.7% and 23.8%. These transfusion thresholds have the potential to lower healthcare costs without compromising quality, ultimately resulting in less costly, efficacious care for the patient. LEVEL OF EVIDENCE/METHODS:Level III.
PMID: 36727962
ISSN: 1940-5480
CID: 5420222

In response

Bi, Andrew S; Fisher, Nina D; Parola, Rown; Ganta, Abhishek; Egol, Kenneth A; Konda, Sanjit R
PMID: 36729658
ISSN: 1531-2291
CID: 5420312

Observational prospective unblinded case-control study to evaluate the effect of the Gamma3® distal targeting system for long nails on radiation exposure and time for distal screw placement

Konda, Sanjit R; Maseda, Meghan; Leucht, Philipp; Tejwani, Nirmal; Ganta, Abhishek; Egol, Kenneth A
PURPOSE/OBJECTIVE:To determine if the DTS decreases radiation exposure (primary outcome measure), fluoroscopy time (secondary outcome measure), and time to distal screw placement (secondary outcome measure) compared to the freehand "perfect circles" method when used for locking of cephalomedullary nails in the treatment of femur fractures METHODS: Fifty-eight patients with hip or femoral shaft fractures that were treated with a long cephalomedullary nail were enrolled in this study. Cohorts were determined based on the method of distal interlocking screw placement into either the "Perfect Circles" or "Distal Targeting" cohort. Time from cephalad screw placement to placement of final distal interlocking screw (seconds), radiation exposure (mGy), and fluoroscopy time (seconds) were compared between groups. Hospital quality measures were compared between cohorts. RESULTS:Use of the DTS resulted in 77% (4.3x) lower radiation exposure (p < 0.001), 64% (2.7x) lower fluoroscopy time (p < 0.001), and 60% (1.7x) lower intraoperative time from end of cephalad screw placement to end of distal interlocking screw placement (p < 0.001) compared to the freehand "perfect circles" method. There was no difference in 30-day or 90-day complication rates between cohorts. CONCLUSION/CONCLUSIONS:The Stryker Gamma3® Distal Targeting System is a safe, effective and efficient alternative to the freehand "perfect circles" method.
PMID: 36517283
ISSN: 1879-0267
CID: 5382252

Adaptive Risk Modeling: Improving Risk Assessment of Geriatric Hip Fracture Patients Throughout their Hospitalization

Esper, Garrett W; Meltzer-Bruhn, Ariana T; Ganta, Abhishek; Egol, Kenneth A; Konda, Sanjit R
INTRODUCTION/BACKGROUND:The purpose of this study was twofold: 1. To assess how adaptive modeling, accounting for development of inpatient complications, affects the predictive capacity of the risk tool to predict inpatient mortality for a cohort of geriatric hip fracture patients. 2. To compare how risk triaging of secondary outcomes is affected by adaptive modeling. We hypothesize that adaptive modeling will improve the predictive capacity of the model and improve the ability to risk triage secondary outcomes. METHODS:and comparative analyses were conducted. RESULTS:experienced the highest rate of mortality, readmission, ICU admission, with longer lengths of stay and higher hospital costs. DISCUSSION/CONCLUSIONS:can better identify patients at risk for developing complications whose mortality and readmission risk profile increase significantly, allowing their new risk classification to inform higher levels of care. While this may increase length of stay and total costs, it may improve outcomes in both the short and long-term. LEVEL OF EVIDENCE/METHODS:III.
PMID: 36464503
ISSN: 1879-0267
CID: 5378562

Intra-articular fracture patterns associated with tibial shaft fractures: more than just the posterior malleolus

Fisher, Nina D; Bi, Andrew S; Parola, Rown; Ganta, Abhishek; Konda, Sanjit; Egol, Kenneth A
BACKGROUND:The association of tibial shaft fractures (TSFs) with posterior malleolar fractures is well described. The purpose of this study was to identify specific radiographic parameters that are predictive of any pattern of associated distal intra-articular fractures in TSFs. METHODS:All TSFs presenting over a 6-year period were identified. A radiographic review of plain radiographs and CT scans included: identification of any associated ankle fracture, classification using the OTA System, measurements of the TSF obliquity angle (FOA), relative distance from distal extent of the TSF to plafond (DFP%), and presence and level of any associated fibular fractures. Patients with and without associated ankle fractures were statistically compared. Multivariate logistic regression determined independent predictors of associated ankle fractures. RESULTS:405 TSFs in 397 patients were identified, with 145 TSFs with associated distal intra-articular fractures. There were 94 (23.2%) posterior malleolar fractures, 19 (13.1%) medial malleolar fractures, 42 (29.0%) lateral malleolar fractures involving the syndesmosis and 14 (9.7%) Chaput fragments. Multivariate regression demonstrated AO/OTA classification type 42-A1, 42-B1 or 42-C1 (OR 2.3 [95% CI 1.3-4.0]; p = 0.003), FOA greater than 45° (OR 2.7 [95% CI 1.5-4.8]; p = 0.001) and DFP% less than 33% (OR 4.1 [95% CI 2.0-9.0]; p = 0.005) were independent correlates of associated ankle fractures regardless of mechanism of injury. CONCLUSIONS:Different patterns of intra-articular fractures beyond posterior malleolar fractures can occur in TSFs. Fracture angles greater than 45° and extent into the distal 33% of the tibial shaft are independent predictors of distal intra-articular fractures in TSFs regardless of mechanism of injury. LEVEL OF EVIDENCE/METHODS:Diagnostic Level III.
PMID: 36323912
ISSN: 1432-1068
CID: 5358652

The Lateral Femoral Cutaneous and Over the Hip (LOH) Block for the Surgical Management of Hip Fractures: A Safe and Effective Anesthetic Strategy

Deemer, Alexa R; Furgiuele, David L; Ganta, Abhishek; Leucht, Philipp; Konda, Sanjit; Tejwani, Nirmal C; Egol, Kenneth A
OBJECTIVES/OBJECTIVE:To examine the efficacy of regional anesthesia with sedation only for a variety of hip fractures using the newly described lateral femoral cutaneous with over the hip Block (LOH Block). DESIGN/METHODS:Retrospective. SETTING/METHODS:Level-I Trauma CenterPatients/Participants: 40 patients who presented between 11/2021 and 02/2022 for fixation of OTA/AO 31.A1-3 and 31.B1-3 fractures. Matched cohorts of 40 patients who received general anesthesia and 40 patients who received spinal anesthesia for hip fracture fixation were also used. INTERVENTION/METHODS:Operative fixation under LOH block and sedation only. The LOH block is a regional hip analgesic that targets the lateral femoral cutaneous nerve, articular branches of femoral nerve (FN) and accessory obturator nerve (AON). MAIN OUTCOME MEASUREMENTS/METHODS:Demographics, intraoperative characteristics, anesthesia-related complications, hospital quality metrics, and short-term mortality and reoperation rates. RESULTS:A total of 120 patients (40 each: general, spinal, LOH block) were compared. The cohorts were similar in age, race, BMI, gender, CCI, trauma risk score, ambulatory status at baseline, fracture type, and surgical fixation technique performed. Physiologic parameters during surgery were more stable in the LOH block group (p<0.05). Total OR time and anesthesia time were shortest for the LOH block cohort (p<0.05). Patients in the LOH block cohort also had lower post-operative pain scores (p<0.05). Length of hospital stay was shortest for patients in the LOH block cohort (p<0.05), and at time of discharge, patients in the LOH block cohort ambulated the furthest (p<0.05). No differences were found in regards to anesthesia-related complications, palliative care consults, major and minor hospital complications, discharge disposition, reoperation and readmission rates, and mortality rates. CONCLUSIONS:The LOH block is safe and effective anesthesia for the treatment of all types of hip fractures in the elderly requiring surgery. In addition, this block may decrease post-operative pain and length of hospital stay, and also allow for greater ambulation in the early post-operative period for hip fracture patients. LEVEL OF EVIDENCE/METHODS:Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
PMID: 36253914
ISSN: 1531-2291
CID: 5360312

Improving Cephalad Lag Screw Placement in the Femoral Head During Cephalomedullary Nailing Using a Novel Augmented Reality System

Konda, Sanjit R; Solasz, Sara; Derken, Meghan; Ganta, Abhishek; Egol, Kenneth A
OBJECTIVES/OBJECTIVE:To measure the effect of a novel augmented reality software designed to aid in lag screw placement into the femoral head for cephalomedullary nails. DESIGN/METHODS:Retrospective cohort study. SETTING/METHODS:Single level I trauma center. PATIENTS/METHODS:Between November 2017 and December 2020, 114 consecutive patients with a hip fracture that underwent repair with a cephalomedullary nail by one of two orthopedic trauma surgeons were reviewed. Fracture classifications included OTA/AO 31-A1, 31-A2, 31-A3, and 31-B3. INTERVENTION/METHODS:The first 57 patients underwent fracture repair without the software (control) and the subsequent 57 patients underwent repair with use of the augmented reality software (AR). MAIN OUTCOME MEASUREMENTS/METHODS:Tip apex distance (TAD) and femoral head zone (AP: superior, center, inferior; Lateral: anterior, center, posterior) were measured using standardized techniques. RESULTS:The mean TAD was lower for the AR vs. control cohort (10.7±2.9 mm vs 15.4±3.8 mm; p<0.001). TAD <10mm for AR vs. control: 25 (43.9%) vs. 3 (5.3%), p<0.001. TAD <15mm for AR vs. control: 50 (87.7%) vs. 44 (77.2%), p<0.001. On the AP view center position was achieved in 50.9% vs. 7.0% of cases for the AR vs. control cohort, respectively. On the lateral view, center position was achieved in 68.4% vs. 12.3% of cases for the AR vs. control cohort, respectively. CONCLUSION/CONCLUSIONS:This study suggests that use of the novel augmented reality software for assistance in lag screw positioning within the femoral head improves overall TAD and ability to achieve the center-center position.
PMID: 36219771
ISSN: 1531-2291
CID: 5360942

Fracture obliquity angle and distance from plafond: novel radiographic predictors of posterior malleolar involvement in tibial shaft fractures

Fisher, Nina D; Bi, Andrew S; Parola, Rown; Ganta, Abhishek; Konda, Sanjit R; Egol, Kenneth A
BACKGROUND:The purpose of this study was to identify specific radiographic parameters that are predictive of associated PM fractures in TSFs. METHODS:All TSFs presenting over a 6-year period were identified. A review of plain radiographs and CT scans included: identification of an isolated PM fracture, AO/OTA classification, measurements of the fracture obliquity angle (FOA), absolute and relative distance from distal extent of fracture to plafond (DFP and DFP%), and presence and level of associated fibular fractures. Patients with and without PM fractures were compared. Multivariate logistic regression determined independent correlates of PM fractures and cutoff values for FOA and DFP%. RESULTS:A total of 405 TSFs in 397 patients were identified, and 94 TSFs (23.2%) had an associated PM fracture. The majority (85.1%) of TSFs with PM fractures were AO/OTA type 42-A1, 42-B1 or 42-C1 (p < 0.001). The mean FOA was 60.9 ± 12.1° in the PM group versus 40.8 ± 18.9° in the non-PM group (p < 0.001). The mean DFP was 5.9 ± 2.7 cm in the PM group versus 11.9 ± 7.9 cm in the non-PM group (p < 0.001). Multivariate regression demonstrated that AO/OTA classification type 42-A1, 42-B1 or 42-C1 (OR 4.7 [95% CI 2.4-9.8]; p < 0.001), FOA greater than 45° (OR 4.4 [95% CI 1.9-10.9]; p = 0.001) and fracture extension to the distal third of the tibia (DFP% < 33%; OR 18.3 [95% CI 3.8-330.4]; p = 0.005) were independent correlates of PMs fractures regardless of mechanism of injury or fibula fracture presence or location (AUROC 0.83 [95% CI 0.80-0.87]). Separate multivariate regression showed for every 1° increase in FOA, PM fracture odds increase 6% per degree and for every 1 cm increase in DFP odds of PM fracture decreased by 15%. CONCLUSIONS:Spiral fractures (simple, wedge or complex), fracture angles greater than 45° and extension into the distal 1/3 of the tibial shaft are independent predictors of PM fractures in TSFs regardless of mechanism of injury.
PMID: 36036819
ISSN: 1432-1068
CID: 5332012

Does mechanism of injury impact the outcome of operative fixation of geriatric proximal humerus fractures

Ganta, Abhishek; Solasz, Sara; Drake, Jack; Littlefield, Connor; Konda, Sanjit; Egol, Kenneth
BACKGROUND:The purpose of this study is to determine the effects of energy mechanism on outcomes following repair of proximal humerus fractures (PHF) in the middle aged and geriatric population. METHODS:Two hundred sixty-nine patients who presented to our academic medical center between 2006 and 2020, and underwent operative treatment of a proximal humerus fracture were prospectively enrolled in an IRB-approved database. Patients above 55 were divided into high energy (motor vehicle accident, pedestrian struck, or fall > 2 stairs) or low energy mechanisms (fall from standing or < 2 stairs). Of 97 patients with complete documentation and follow-up, 72 were included in the low velocity (LV) group and 25 were included in the high velocity (HV) group. Demographic information, primary injury details, healing and time to union, range of motion (ROM), complications, and need for reoperation were assessed at initial presentation and subsequent follow-up appointments. RESULTS:Mean age, BMI, and gender were significantly different between the LV and HV cohorts (p = 0.01, 0.04, 0.01). OTA/AO fracture patterns were similar between the groups. (p = 0.14). Bony healing and complications occurred with similar frequency between groups (p = 1.00, 0.062). The most common complications in the LV and HV groups included avascular necrosis (9.7%, 16.0%), and screw penetration (4.2%, 12.0%), while the HV group also had rotator cuff issues including weakness and tendonitis (12.0%). There was no significant difference in need for reoperation between cohorts (p = 0.45). Time to healing, shoulder ROM, and DASH scores did not differ between each group. CONCLUSIONS:Energy and mechanism demonstrates similar outcomes in operatively treated proximal humerus fractures. These factors should not play a role in decisions for surgery in these patients and can help guide patient expectations.
PMID: 36098793
ISSN: 1434-3916
CID: 5332812

Fixed-angle plate fixation and autogenous iliac crest graft for repair of distal metaphyseal femoral nonunion

Landes, Emma K; Konda, Sanjit R; Leucht, Philipp; Ganta, Abhishek; Egol, Kenneth A
PURPOSE/OBJECTIVE:To analyze clinical, radiographic and patient-reported outcomes of distal metaphyseal femoral nonunions treated with fixed-angle plates and screws. METHODS:All patients presenting with a distal metaphyseal femoral fracture nonunion repaired with fixed-angle plating from one urban level 1 trauma center and an orthopedic specialty hospital were identified. Baseline demographic, injury information, and outcomes (healing rates, Short Musculoskeletal Function Assessment, range of motion, and post-operative pain levels) at 12 months following nonunion repair were collected. Outcomes were evaluated between patients fixed with a blade plate and with a locking plate. RESULTS:Of these 31 patients, 27 (87.1%) healed after their index nonunion surgery, 2 (6.5%) healed after one reoperation, 1 (3.2%) healed after 2 reoperations, and 1 (3.2%) had a persistent nonunion but did not want further treatment. At one-year follow-up, the group demonstrated a significant improvement in functional recovery with a mean difference of 14.5 points (p = 0.007) when compared to status before fixed-angle fixation of the nonunion. There was also a significant change in patient-reported pain levels using the VAS scale with a mean difference of 2.0 points (p = 0.009). At one-year follow-up, 11 (39.3%) had full knee range of motion (0-130), 11 (39.3%) had flexion greater than 90 and less than 120°, and 6 (21.4%) had range of motion less than 90°. CONCLUSION/CONCLUSIONS:Patients who undergo fixed angle plating and autogenous bone grafting for distal femoral metapyseal nonunions demonstrate improved functional outcomes and VAS pain score at one year follow up.
PMID: 35980539
ISSN: 1432-1068
CID: 5300132