PURPOSE OF REVIEW/OBJECTIVE:To review the current literature and summarize the main principles found between viral infections and the subsequent production of autoantibodies. RECENT FINDINGS/RESULTS:We concentrate on recent findings involving three viral agents, one of which is Epstein-Barr virus, which has been associated with many autoimmune diseases and is classically considered to induce systemic lupus erythematosus. As we will discuss, this occurs through molecular mimicry between Epstein-Barr virus nuclear antigen 1 and lupus-specific antigens such as Ro, La or dsDNA, through induction of Toll-like receptor hypersensitivity by Epstein-Barr virus latent membrane protein 2A or by creating immortal B and T cells by loss of apoptosis. Hepatitis B virus was found to share amino acid sequences with different autoantigens. Tissue damage and the release of intracellular components is just another example of the autoantibody production caused by this virus. Cytomegalovirus has often been controversially associated with several autoimmune diseases and, although is the least understood viral infection of the three, appears to be somewhat suspicious. SUMMARY/CONCLUSIONS:Understanding the infectious origin of autoimmune diseases is important as we aim to identify high-risk patients and disrupt this process with vaccines or other medications, ultimately delaying or even preventing the evolution of autoimmune diseases.
PMID: 17917546
ISSN: 1040-8711
CID: 6013822
Evaluation of the BioPlex 2200 ANA screen: analysis of 510 healthy subjects: incidence of natural/predictive autoantibodies
Shovman, O; Gilburd, B; Barzilai, O; Shinar, E; Larida, B; Zandman-Goddard, G; Binder, S R; Shoenfeld, Y
The BioPlex 2200 ANA Screen is a fully automated system that determines levels for 13 different autoimmune antibodies of established clinical significance. The objective of this study was to determine the specificity of the BioPlex 2200 ANA Screen assay and to analyze the antibody profile samples collected from healthy subjects against comparative ELISA and IIF screening methods. A total of 510 specimens were randomly selected from a cohort of apparently healthy blood bank donors. Samples were distributed to five age brackets. All samples were tested using Bio-Rad's ANA Screen kit. Specificity was compared to IIF and ELISA results. Most of the samples were found negative in all ANA screening systems (84.5% by IIF, 92.5% by BioPlex 2200 ANA Screen kit, and 94.5% by ELISA). The frequency of positive results was highest (15.5%) using IIF, in comparison to almost similar results (5.5% vs. 7.5%) achieved by ANA ELISA and BioPlex 2200 ANA Screen kits. The positive rate of autoantibodies was significantly reduced when analyzed by different combinations of ANA screen assays (from 2.35% using IIF + BioPlex ANA Screen tests to 0.98% by using all three tests). Using the BioPlex 2200 ANA Screen system, we were able to identify samples with high levels of individual antibodies: anti-dsDNA at 20-63 IU/mL, antichromatin at 4-8 AI, anti-SmRNP at 2-6 AI, and anti-RNPA at 2-4.5 AI. Importantly, from 7 IIF and ELISA positive sera, 5 of these were also BioPlex 2200 positive, suggesting that the BioPlex is seeing the samples that are of the greatest interest, using the established techniques. The specificity of the BioPlex 2200 ANA Screen analysis of 13 different analytes (dsDNA, centromere B, chromatin, Jo1, ribosomal P, RNP 68, RNP A, Scl-70, Sm, SmPNP, SS-A52, SS-A60, SS-B) is comparable (P < 0.252) to the ELISA ANA screening test. Like the ELISA, the BioPlex 2200 has a lower (P < 0.001) positive rate than IIF for the autoantibody screening.
PMID: 16014555
ISSN: 0077-8923
CID: 6013772