Foreign Body Emboli following Cerebrovascular Interventions: Clinical, Radiographic, and Histopathologic Features
Shapiro, M; Ollenschleger, M D; Baccin, C; Becske, T; Spiegel, G R; Wang, Y; Song, X; Raz, E; Zumofen, D; Potts, M; Nelson, P K
Foreign material emboli following cerebral, cardiac, and peripheral catheterizations have been reported since the mid-1990s. Catheter coatings have been frequently implicated. The most recent surge of interest in this phenomenon within the neurointerventional community is associated with procedures using flow-diversion devices for the treatment of cerebral aneurysms. Following coil-supported Pipeline embolization in 4 cases and stent-supported coiling in 1, 5 patients developed multiple subcentimeter enhancing lesions, usually with surrounding edema and variable magnetic susceptibility in the vascular territories of the treated aneurysms. Conventional angiography findings were unrevealing. Laboratory work-up showed mild CSF protein elevation with no leukocytosis. Brain biopsy in 2 cases revealed granulomatous angiitis encasing foreign material, identical in stain appearance to a polyvinylpyrrolidone catheter coating. Corticosteroid administration typically produced clinical improvement. A heterogeneous radiographic and clinical course was noted, with rise and fall in the number of enhancing lesions in 2 patients and persistence in others. The etiology may be related to widespread adoption of increasingly sophisticated catheterization techniques.
PMID: 26294650
ISSN: 1936-959x
CID: 1732492
Use of Pipeline Embolization Devices for treatment of a direct carotid-cavernous fistula
Nossek, E; Zumofen, D; Nelson, E; Raz, E; Potts, M B; Desousa, K G; Tanweer, O; Shapiro, M; Becske, T; Riina, Howard A
BACKGROUND: The use of minimally porous endoluminal devices (MPEDs) such as the Pipeline Embolization Device (PED) has been described for the treatment of brain aneurysms. The benefit of using MPEDs to assist embolization of a direct high-flow carotid cavernous fistula resulting from a ruptured cavernous carotid artery aneurysm is not well documented. METHODS: We describe our experience with deploying a tailored multidevice PED construct across the cavernous internal carotid artery (ICA) wall defect in combination with transarterial coil embolization using the "jailed microcatheter" technique. RESULTS: A 59-year-old woman presented with acute left-sided ophthalmoplegia. Diagnostic cerebral angiography demonstrated a ruptured giant cavernous carotid aneurysm with fistulous outflow via the ipsilateral left superior ophthalmic vein and into the pterygoid venous plexi bilaterally. Via the Marksman microcatheter, a total of three PEDs measuring 4.5 mm x 18 mm, 4.5 mm x 20 mm, and 4.75 mm x 16 mm were telescoped within the ICA across the aneurysm neck. Coiling of the aneurysm fundus and cavernous sinus via the "jailed" Rapidtransit microcatheter was subsequently achieved. A 2-year follow-up digital subtraction angiography (DSA) demonstrated stable obliteration of the aneurysm and the fistula, coincident with complete resolution of the patient's symptoms. CONCLUSIONS: Based on our long-term clinical and angiographic results, we advocate that the presented method be a valid treatment option for selected cases.
PMID: 25981434
ISSN: 0942-0940
CID: 1630972
Endoluminal Reconstruction for Nonsaccular Aneurysms of the Proximal Posterior Cerebral Artery with the Pipeline Embolization Device
Zumofen, D W; Shapiro, M; Becske, T; Raz, E; Potts, M B; Riina, H A; Nelson, P K
BACKGROUND AND PURPOSE: Treatment options for nonsaccular posterior cerebral artery aneurysms include a range of surgical and endovascular reconstructive and deconstructive methods. However, no truly satisfactory treatment option is available to date for lesions arising from the P1 and P2 segments. The purpose of the present case series is to investigate both the efficacy and safety of the Pipeline Embolization Device in treating these challenging aneurysms. MATERIALS AND METHODS: We present a series of 6 consecutive patients who underwent endoluminal reconstruction with the Pipeline Embolization Device for nonsaccular P1 or P2 segment aneurysms between January 2009 and June 2013. RESULTS: Aneurysm location included the P1 segment in 2 patients and the P2 segment in 4 patients. Mean aneurysm diameter was 23 mm (range, 5-44 mm). Mean length of the arterial segment involved was 10 mm (range, 6-19 mm). Clinical presentation included mass effect in 4 patients and perforator stroke and subacute aneurysmal subarachnoid hemorrhage in 1 patient each. Endovascular reconstruction was performed by using 1 Pipeline Embolization Device in 5 patients and 2 overlapping Pipeline Embolization Devices in the remaining patient. Angiographic aneurysm occlusion was immediate in 1 patient, within 6 months in 4 patients, and within 1 year in the remaining patient. Index symptoms resolved in 4 patients and stabilized in the remaining 2. No new permanent neurologic sequelae and no aneurysm recurrence were recorded during the mean follow-up period of 613 days (range, 540-725 days). CONCLUSIONS: Endovascular reconstruction with the Pipeline Embolization Device for nonsaccular aneurysms arising from the P1 and P2 segments compares favorably with historical treatment options in terms of occlusion rate, margin of safety, and neurologic outcome.
PMID: 25792531
ISSN: 1936-959x
CID: 1669452
Anterior Choroidal Artery Patency and Clinical Follow-Up after Coverage with the Pipeline Embolization Device
Raz, E; Shapiro, M; Becske, T; Zumofen, D W; Tanweer, O; Potts, M B; Riina, H A; Nelson, P K
BACKGROUND AND PURPOSE: Endoluminal reconstruction with the Pipeline Embolization Device is an effective treatment option for select intracranial aneurysms. However, concerns for the patency of eloquent branch arteries covered by the Pipeline Embolization Device have been raised. We aimed to examine the patency of the anterior choroidal artery and clinical sequelae after ICA aneurysm treatment. MATERIALS AND METHODS: We prospectively analyzed all patients among our first 157 patients with ICA aneurysms treated by the Pipeline Embolization Device who required placement of at least 1 device across the ostium of the anterior choroidal artery. The primary outcome measure was angiographic patency of the anterior choroidal artery at last follow-up. Age, sex, type of aneurysm, neurologic examination data, number of Pipeline Embolization Devices used, relationship of the anterior choroidal artery to the aneurysm, and completeness of aneurysm occlusion on follow-up angiograms were also analyzed. RESULTS: Twenty-nine aneurysms requiring placement of at least 1 Pipeline Embolization Device (median = 1, range = 1-3) across the anterior choroidal artery ostium were identified. At angiographic follow-up (mean = 15.1 months; range = 12-39 months), the anterior choroidal artery remained patent, with antegrade flow in 28/29 aneurysms (96.5%), while 24/29 (82.7%) of the target aneurysms were angiographically occluded by 1-year follow-up angiography. Anterior choroidal artery occlusion, with retrograde reconstitution of the vessel, was noted in a single case. A significant correlation between the origin of the anterior choroidal artery from the aneurysm dome and failure of the aneurysms to occlude following treatment was found. CONCLUSIONS: After placement of 36 Pipeline Embolization Devices across 29 anterior choroidal arteries (median = 1 device, range = 1-3 devices), 1 of 29 anterior choroidal arteries was found occluded on angiographic follow-up. The vessel occlusion did not result in persistent clinical sequelae. Coverage of the anterior choroidal artery origin with the Pipeline Embolization Device, hence, may be considered reasonably safe when deemed necessary for aneurysm treatment.
PMID: 25572948
ISSN: 0195-6108
CID: 1432982
Cavernous Carotid Aneurysms in the Era of Flow Diversion: A Need to Revisit Treatment Paradigms
Tanweer, O; Raz, E; Brunswick, A; Zumofen, D; Shapiro, M; Riina, H A; Fouladvand, M; Becske, T; Nelson, P K
BACKGROUND AND PURPOSE: Recent techniques of endoluminal reconstruction with flow-diverting stents have not been incorporated into treatment algorithms for cavernous carotid aneurysms. This study examines the authors' institutional experience and a systematic review of the literature for outcomes and complications using the Pipeline Embolization Device in unruptured cavernous carotid aneurysms. MATERIALS AND METHODS: A retrospective search for cavernous carotid aneurysms from a prospectively collected data base of aneurysms treated with the Pipeline Embolization Device at our institution was performed. Baseline demographic, clinical, and laboratory values; intrainterventional data; and data at all follow-up visits were collected. A systematic review of the literature for complication data was performed with inquiries sent when clarification of data was needed. RESULTS: Forty-three cavernous carotid aneurysms were included in the study. Our mean radiographic follow-up was 2.05 years. On last follow-up, 88.4% of the aneurysms treated had complete or near-complete occlusion. Aneurysm complete or near-complete occlusion rates at 6 months, 12 months, and 36 months were 81.4%, 89.7%, and 100%, respectively. Of patients with neuro-ophthalmologic deficits on presentation, 84.2% had improvement in their visual symptoms. Overall, we had a 0% mortality rate and a 2.3% major neurologic complication rate. Our systematic review of the literature yielded 227 cavernous carotid aneurysms treated with the Pipeline Embolization Device with mortality and morbidity rates of 0.4% and 3.1%, respectively. CONCLUSIONS: Endoluminal reconstruction with flow diversion for large unruptured cavernous carotid aneurysms can yield high efficacy with low complications. Further long-term data will be helpful in assessing the durability of the cure; however, we advocate a revisiting of current management paradigms for cavernous carotid aneurysms.
PMID: 25147199
ISSN: 0195-6108
CID: 1165082
Building multidevice pipeline constructs of favorable metal coverage: a practical guide
Shapiro, M; Raz, E; Becske, T; Nelson, P K
BACKGROUND AND PURPOSE: The advent of low-porosity endoluminal devices, also known as flow diverters, exemplified by the Pipeline in the United States, produced the greatest paradigm shift in cerebral aneurysm treatment since the introduction of detachable coils. Despite robust evidence of efficacy and safety, key questions regarding the manner of their use remain unanswered. Recent studies demonstrated that the Pipeline device geometry can dramatically affect its metal coverage, emphasizing the negative effects of oversizing the device relative to its target vessels. This follow-up investigation focuses on the geometry and coverage of multidevice constructs. MATERIALS AND METHODS: A number of Pipeline devices were deployed in tubes of known diameters and photographed, and the resultant coverage was determined by image segmentation. Multidevice segmentation images were created to study the effects of telescoped devices and provide an estimate of coverages resulting from device overlap. RESULTS: Double overlap yields a range of metal coverage, rather than a single value, determined by the diameters of both devices, the size of the recipient artery, and the degree to which strands of the overlapped devices are coregistered with each other. The potential variation in coverage is greatest during overlap of identical-diameter devices, for example, ranging from 24% to 41% for two 3.75-mm devices deployed in a 3.5-mm vessel. Overlapping devices of progressively different diameters produce correspondingly more uniform ranges of coverage, though reducing the maximum achievable value, for example, yielding a 33%-34% range for 3.75- and 4.75-mm devices deployed in the same 3.5-mm vessel. CONCLUSIONS: Rational strategies for building multidevice constructs can achieve favorable geometric outcomes.
PMID: 24676003
ISSN: 0195-6108
CID: 1131572
Non-saccular vertebrobasilar aneurysms and dolichoectasia: a systematic literature review
Shapiro, Maksim; Becske, Tibor; Riina, Howard A; Raz, Eytan; Zumofen, Daniel; Nelson, Peter K
BACKGROUND AND OBJECTIVE: Treatment of non-saccular vertebrobasilar aneurysms remains highly challenging despite significant recent advances in endovascular techniques. Establishing the natural history of this heterogeneous disease, as best as currently available data allows, is crucial to help guide counseling and management. METHODS: A review of the literature was conducted to identify publications describing the presentation and natural history of vertebrobasilar dolichoectasia and non-saccular aneurysms. RESULTS: Nine studies of 440 patients met the analysis inclusion criteria. The majority of patients presented with ischemia, mass effect, or incidentally; hemorrhage was uncommon and overlapped with the population of vertebrobasilar dissection. Overall mortality was approximately 40% after 7 years of follow-up, with 43% of these deaths resulting from non-neurologic causes. Neurologic course was dominated by ischemic stroke rather than hemorrhage. Mass effect prognosis was especially poor, with 40% mortality after approximately 4 years. Incidentally discovered lesions which remain morphologically stable have a favorable long term course. CONCLUSIONS: Initial clinical presentation is a strong predictor of subsequent disease course. Although overall prognosis is poor, nearly half of all deaths resulted from non-neurologic causes, underscoring the importance of comprehensive medical management. Aneurysms characterized by expansion, established mass effect, or hemorrhage have a poor natural history, and may be considered for invasive treatment, which is increasingly endovascular in nature. Lesions presenting with ischemia or incidentally are likely best addressed with aggressive neurologic and overall medical management.
PMID: 23843444
ISSN: 1759-8478
CID: 463792
Temporary stent scaffolding during aneurysm coiling
Zumofen, Daniel W; Sahasrabudhe, Nikhil; Riina, Howard A; Raz, Eytan; Shapiro, Maksim; Becske, Tibor; Nelson, Peter K
We report a case of temporary Solitaire FR stent (Covidien, Mansfield, MA, USA) scaffolding to reduce coil herniation during embolization of a large neck anterior communicating artery aneurysm. In contrast to classic stent-assisted coiling, the fully retrievable stent is recaptured prior to detachment of the last coil. The presented technical nuance hence does not require institution of prolonged antiplatelet coverage. But the door is left open for coil-repositioning in case of coil basket instability. Permanent stent redeployment remains a fall-back option if critical hardware conflict occurs. In comparison to classic balloon remodeling, the presented method may offer easier distal access, particularly in tortuous arterial anatomy. Temporary occlusion of the parent artery, side branches, and perforators is also avoided. Given its specific potential advantages, temporary stent scaffolding using the fully retrievable Solitaire FR device may find its niche as a bailout option, primarily in a very specific subset of distally located wide neck aneurysms.
PMID: 24331624
ISSN: 0967-5868
CID: 759432
Variable porosity of the pipeline embolization device in straight and curved vessels: a guide for optimal deployment strategy
Shapiro, M; Raz, E; Becske, T; Nelson, P K
BACKGROUND AND PURPOSE: Low-porosity endoluminal devices for the treatment of intracranial aneurysms, also known as flow diverters, have been in experimental and clinical use for close to 10 years. Despite rigorous evidence of their safety and efficacy in well-controlled trials, a number of key factors concerning their use remain poorly defined. Among these, none has received more attention to date than the debate on how many devices are optimally required to achieve a safe, effective, and economical outcome. Additional, related questions concern device sizing relative to the parent artery and optimal method of deployment of the devices. While some or all of these issues may be ultimately answered on an empiric basis via subgroup analysis of growing treatment cohorts, we believe that careful in vitro examination of relevant device properties can also help guide its in vivo use. MATERIALS AND METHODS: We conducted a number of benchtop experiments to investigate the varied porosity of Pipeline Embolization Devices deployed in a simulated range of parent vessel diameters and applied these results toward conceptualizing optimal treatment strategies of fusiform and wide-neck aneurysms. RESULTS: The results of our studies confirm a predictable parabolic variability in device porosity based on the respective comparative sizes of the device and recipient artery, as well as device curvature. Even modest oversizing leads to a significant increase in porosity. CONCLUSIONS: The experiments demonstrate various deleterious effects of device oversizing relative to the parent artery and provide strategies for addressing size mismatches when they are unavoidable.
PMID: 24072622
ISSN: 0195-6108
CID: 953932
Toward an Endovascular Internal Carotid Artery Classification System
Shapiro, M; Becske, T; Riina, H A; Raz, E; Zumofen, D; Jafar, J J; Huang, P P; Nelson, P K
SUMMARY:Does the world need another ICA classification scheme? We believe so. The purpose of proposed angiography-driven classification is to optimize description of the carotid artery from the endovascular perspective. A review of existing, predominantly surgically-driven classifications is performed, and a new scheme, based on the study of NYU aneurysm angiographic and cross-sectional databases is proposed. Seven segments - cervical, petrous, cavernous, paraophthlamic, posterior communicating, choroidal, and terminus - are named. This nomenclature recognizes intrinsic uncertainty in precise angiographic and cross-sectional localization of aneurysms adjacent to the dural rings, regarding all lesions distal to the cavernous segment as potentially intradural. Rather than subdividing various transitional, ophthalmic, and hypophyseal aneurysm subtypes, as necessitated by their varied surgical approaches and risks, the proposed classification emphasizes their common endovascular treatment features, while recognizing that many complex, trans-segmental, and fusiform aneurysms not readily classifiable into presently available, saccular aneurysm-driven schemes, are being increasingly addressed by endovascular means. We believe this classification may find utility in standardizing nomenclature for outcome tracking, treatment trials and physician communication.
PMID: 23928138
ISSN: 0195-6108
CID: 681202