Try a new search

Format these results:

Searched for:

in-biosketch:true

person:shapim06

Total Results:

143


Treatment of distal anterior cerebral artery aneurysms with the Pipeline Embolization Device

Nossek, Erez; Zumofen, Daniel W; Setton, Avi; Potts, Matthew B; Raz, Eytan; Shapiro, Maksim; Riina, Howard A; De Miquel, Maria Angeles; Chalif, David J; Nelson, Peter K
Aneurysms of the anterior cerebral artery (ACA) located distal to the anterior communicating artery complex (ACOM) remain challenging to treat with surgical clip reconstruction as well as with endovascular coil-embolization strategies. We have treated five complex geometry distal ACA aneurysms with endoluminal reconstruction using the Pipeline Embolization Device (PED). Two aneurysms were of the dysplastic fusiform type. Three aneurysms were of complex saccular configuration. Three aneurysms were treated electively at the outset with PED. One patient had previously undergone aborted clip reconstruction, and one was treated for recurrent aneurysm growth after coil embolization. The mean diameter of the ACA in this cohort was 1.96mm proximal to the aneurysm and 1.79mm distal to the aneurysmal segment. A single PED of 2.5mm inner diameter was the sole treatment in four cases. Two PEDs, telescopically overlapped across the aneurysm, were used in the remaining case. All devices were deployed successfully. No parent artery occlusion or stenosis was observed. In all cases an associated branch vessel arising from the vicinity of the aneurysm or incorporated into its neck was covered by the endoluminal construct. At follow-up angiography, robust antegrade flow was maintained in the jailed branch. One patient experienced asymptomatic, delayed occlusion of the jailed branch. Complete aneurysm occlusion was seen in all patients. We confirm that PED can be deployed in parent vessels smaller than 2mm diameter, and that endoluminal reconstruction with the PED may be a safe and effective treatment alternative for selected distal ACA aneurysms.
PMID: 27863970
ISSN: 1532-2653
CID: 2311092

Pipeline for uncoilable or failed aneurysms: 3-year follow-up results

Becske, Tibor; Potts, Matthew B; Shapiro, Maksim; Kallmes, David F; Brinjikji, Waleed; Saatci, Isil; McDougall, Cameron G; Szikora, Istvan; Lanzino, Giuseppe; Moran, Christopher J; Woo, Henry H; Lopes, Demetrius K; Berez, Aaron L; Cher, Daniel J; Siddiqui, Adnan H; Levy, Elad I; Albuquerque, Felipe C; Fiorella, David J; Berentei, Zsolt; Marosfoi, Miklos; Cekirge, Saruhan H; Nelson, Peter K
OBJECTIVE The long-term effectiveness of endovascular treatment of large and giant wide-neck aneurysms using traditional endovascular techniques has been disappointing, with high recanalization and re-treatment rates. Flow diversion with the Pipeline Embolization Device (PED) has been recently used as a stand-alone therapy for complex aneurysms, showing significant improvement in effectiveness while demonstrating a similar safety profile to stent-supported coil treatment. However, relatively little is known about its long-term safety and effectiveness. Here the authors report on the 3-year safety and effectiveness of flow diversion with the PED in a prospective cohort of patients with large and giant internal carotid artery aneurysms enrolled in the Pipeline for Uncoilable or Failed Aneurysms (PUFS) trial. METHODS The PUFS trial is a prospective study of 107 patients with 109 aneurysms treated with the PED. Primary effectiveness and safety end points were demonstrated based on independently monitored 180-day clinical and angiographic data. Patients were enrolled in a long-term follow-up protocol including 1-, 3-, and 5-year clinical and imaging follow-up. In this paper, the authors report the midstudy (3-year) effectiveness and safety data. RESULTS At 3 years posttreatment, 74 subjects with 76 aneurysms underwent catheter angiography as required per protocol. Overall, complete angiographic aneurysm occlusion was observed in 71 of these 76 aneurysms (93.4% cure rate). Five aneurysms were re-treated, using either coils or additional PEDs, for failure to occlude, and 3 of these 5 were cured by the 3-year follow-up. Angiographic cure with one or two treatments of Pipeline embolization alone was therefore achieved in 92.1%. No recanalization of a previously completely occluded aneurysm was noted on the 3-year angiograms. There were 3 (2.6%) delayed device- or aneurysm-related serious adverse events, none of which led to permanent neurological sequelae. No major or minor late-onset hemorrhagic or ischemic cerebrovascular events or neurological deaths were observed in the 6-month through 3-year posttreatment period. Among 103 surviving patients, 85 underwent functional outcome assessment in which modified Rankin Scale scores of 0-1 were demonstrated in 80 subjects. CONCLUSIONS Pipeline embolization is safe and effective in the treatment of complex large and giant aneurysms of the intracranial internal carotid artery. Unlike more traditional endovascular treatments, flow diversion results in progressive vascular remodeling that leads to complete aneurysm obliteration over longer-term follow-up without delayed aneurysm recanalization and/or growth. Clinical trial registration no.: NCT00777088 ( clinicaltrials.gov ).
PMID: 27739944
ISSN: 1933-0693
CID: 2278522

Learning from failure: persistence of aneurysms following pipeline embolization

Shapiro, Maksim; Becske, Tibor; Nelson, Peter K
OBJECTIVE A detailed analysis was performed of anterior circulation aneurysms treated with a Pipeline Embolization Device (PED) that did not progress to complete occlusion by 1-year follow-up. Angiography was performed with the purpose of identifying specific factors potentially responsible for these failed outcomes. METHODS From among the first 100 patients with anterior circulation aneurysms, 92 underwent 1-year follow-up angiography and were individually studied through review of their pre- and postembolization studies. RESULTS Nineteen aneurysms (21%) remained unoccluded at 12 months. Independent predictors of treatment failure, identified by logistic regression analysis, were found to be fusiform aneurysm morphology, decreasing dome-to-neck ratio, and the presence of a preexisting laser-cut stent. Further examination of individual cases identified several common mechanisms-device malapposition, inadequate coverage of the aneurysm neck with persistent exchange across the device, and the incorporation of a branch vessel into the aneurysm fundus-potentially contributing to failed treatment in these settings. CONCLUSIONS Attention to specific features of the aneurysm and device construct can frequently identify cases predisposed to treatment failure and suggest strategies to maximize favorable outcomes.
PMID: 27153168
ISSN: 1933-0693
CID: 2101322

Percutaneous Retrieval of an Embolized Kyphoplasty Cement Fragment From the Pulmonary Artery: A Case Report and Literature Review

Lamparello, Nicole A; Jaswani, Vijay; DeSousa, Keith; Shapiro, Maksim; Kovacs, Sandor
We present a case of a 41-year-old man with symptomatic pulmonary cement embolism following percutaneous vertebral augmentation, which was successfully retrieved via a percutaneous endovascular approach, a novel technique with only two prior cases reported. Cement leakage, including venous embolization of cement into the cardiopulmonary circulation, is a known potential complication following percutaneous kyphoplasty and vertebroplasty. While many patients with pulmonary cement embolism are asymptomatic and likely go undiagnosed, others experience respiratory distress and hemodynamic compromise requiring surgical and medical intervention. The optimal management for pulmonary cement embolism must be tailored to fit each individual patient, dependent upon the acuity of the clinical presentation, coexisting patient comorbidities, and the risks of systemic anticoagulation. In our patient, cement migration was visualized in real-time during vertebral augmentation. Endovascular retrieval by our Interventional Radiology section obviated the need for anticoagulation therapy or more invasive open surgical procedures.
PMCID:5065278
PMID: 27761188
ISSN: 1943-0922
CID: 2280052

Posterior Spinal Artery Aneurysm Presenting with Leukocytoclastic Vasculitis

Hill, Travis C; Tanweer, Omar; Thomas, Cheddhi; Engler, John; Shapiro, Maksim; Becske, Tibor; Huang, Paul P
Rupture of isolated posterior spinal artery (PSA) aneurysms is a rare cause of subarachnoid hemorrhage (SAH) that presents unique diagnostic challenges owing to a nuanced clinical presentation. Here, we report on the diagnosis and management of the first known case of an isolated PSA aneurysm in the context of leukocytoclastic vasculitis. A 53-year-old male presented to an outside institution with acute bilateral lower extremity paralysis 9 days after admission for recurrent cellulitis. Early magnetic resonance imaging was read as negative and repeat imaging 15 days after presentation revealed SAH and a compressive spinal subdural hematoma. Angiography identified a PSA aneurysm at T9, as well as other areas suspicious for inflammatory or post-hemorrhagic reactive changes. The patient underwent a multilevel laminectomy for clot evacuation and aneurysm resection to prevent future hemorrhage and to establish a diagnosis. The postoperative course was complicated by medical issues and led to the diagnosis of leukocytoclastic vasculitis that may have predisposed the patient to aneurysm development. Literature review reveals greater mortality for cervical lesions than thoracolumbar lesions and that the presence of meningitic symptoms portents better functional outcome than symptoms of cord compression. The outcome obtained in this case is consistent with outcomes reported in the literature.
PMCID:4842908
PMID: 27114966
ISSN: 2234-8565
CID: 2091992

Foreign Body Emboli following Cerebrovascular Interventions: Clinical, Radiographic, and Histopathologic Features

Shapiro, M; Ollenschleger, M D; Baccin, C; Becske, T; Spiegel, G R; Wang, Y; Song, X; Raz, E; Zumofen, D; Potts, M; Nelson, P K
Foreign material emboli following cerebral, cardiac, and peripheral catheterizations have been reported since the mid-1990s. Catheter coatings have been frequently implicated. The most recent surge of interest in this phenomenon within the neurointerventional community is associated with procedures using flow-diversion devices for the treatment of cerebral aneurysms. Following coil-supported Pipeline embolization in 4 cases and stent-supported coiling in 1, 5 patients developed multiple subcentimeter enhancing lesions, usually with surrounding edema and variable magnetic susceptibility in the vascular territories of the treated aneurysms. Conventional angiography findings were unrevealing. Laboratory work-up showed mild CSF protein elevation with no leukocytosis. Brain biopsy in 2 cases revealed granulomatous angiitis encasing foreign material, identical in stain appearance to a polyvinylpyrrolidone catheter coating. Corticosteroid administration typically produced clinical improvement. A heterogeneous radiographic and clinical course was noted, with rise and fall in the number of enhancing lesions in 2 patients and persistence in others. The etiology may be related to widespread adoption of increasingly sophisticated catheterization techniques.
PMID: 26294650
ISSN: 1936-959x
CID: 1732492

Endoluminal Reconstruction for Nonsaccular Aneurysms of the Proximal Posterior Cerebral Artery with the Pipeline Embolization Device

Zumofen, D W; Shapiro, M; Becske, T; Raz, E; Potts, M B; Riina, H A; Nelson, P K
BACKGROUND AND PURPOSE: Treatment options for nonsaccular posterior cerebral artery aneurysms include a range of surgical and endovascular reconstructive and deconstructive methods. However, no truly satisfactory treatment option is available to date for lesions arising from the P1 and P2 segments. The purpose of the present case series is to investigate both the efficacy and safety of the Pipeline Embolization Device in treating these challenging aneurysms. MATERIALS AND METHODS: We present a series of 6 consecutive patients who underwent endoluminal reconstruction with the Pipeline Embolization Device for nonsaccular P1 or P2 segment aneurysms between January 2009 and June 2013. RESULTS: Aneurysm location included the P1 segment in 2 patients and the P2 segment in 4 patients. Mean aneurysm diameter was 23 mm (range, 5-44 mm). Mean length of the arterial segment involved was 10 mm (range, 6-19 mm). Clinical presentation included mass effect in 4 patients and perforator stroke and subacute aneurysmal subarachnoid hemorrhage in 1 patient each. Endovascular reconstruction was performed by using 1 Pipeline Embolization Device in 5 patients and 2 overlapping Pipeline Embolization Devices in the remaining patient. Angiographic aneurysm occlusion was immediate in 1 patient, within 6 months in 4 patients, and within 1 year in the remaining patient. Index symptoms resolved in 4 patients and stabilized in the remaining 2. No new permanent neurologic sequelae and no aneurysm recurrence were recorded during the mean follow-up period of 613 days (range, 540-725 days). CONCLUSIONS: Endovascular reconstruction with the Pipeline Embolization Device for nonsaccular aneurysms arising from the P1 and P2 segments compares favorably with historical treatment options in terms of occlusion rate, margin of safety, and neurologic outcome.
PMID: 25792531
ISSN: 1936-959x
CID: 1669452

Use of Pipeline Embolization Devices for treatment of a direct carotid-cavernous fistula

Nossek, E; Zumofen, D; Nelson, E; Raz, E; Potts, M B; Desousa, K G; Tanweer, O; Shapiro, M; Becske, T; Riina, Howard A
BACKGROUND: The use of minimally porous endoluminal devices (MPEDs) such as the Pipeline Embolization Device (PED) has been described for the treatment of brain aneurysms. The benefit of using MPEDs to assist embolization of a direct high-flow carotid cavernous fistula resulting from a ruptured cavernous carotid artery aneurysm is not well documented. METHODS: We describe our experience with deploying a tailored multidevice PED construct across the cavernous internal carotid artery (ICA) wall defect in combination with transarterial coil embolization using the "jailed microcatheter" technique. RESULTS: A 59-year-old woman presented with acute left-sided ophthalmoplegia. Diagnostic cerebral angiography demonstrated a ruptured giant cavernous carotid aneurysm with fistulous outflow via the ipsilateral left superior ophthalmic vein and into the pterygoid venous plexi bilaterally. Via the Marksman microcatheter, a total of three PEDs measuring 4.5 mm x 18 mm, 4.5 mm x 20 mm, and 4.75 mm x 16 mm were telescoped within the ICA across the aneurysm neck. Coiling of the aneurysm fundus and cavernous sinus via the "jailed" Rapidtransit microcatheter was subsequently achieved. A 2-year follow-up digital subtraction angiography (DSA) demonstrated stable obliteration of the aneurysm and the fistula, coincident with complete resolution of the patient's symptoms. CONCLUSIONS: Based on our long-term clinical and angiographic results, we advocate that the presented method be a valid treatment option for selected cases.
PMID: 25981434
ISSN: 0942-0940
CID: 1630972

Anterior Choroidal Artery Patency and Clinical Follow-Up after Coverage with the Pipeline Embolization Device

Raz, E; Shapiro, M; Becske, T; Zumofen, D W; Tanweer, O; Potts, M B; Riina, H A; Nelson, P K
BACKGROUND AND PURPOSE: Endoluminal reconstruction with the Pipeline Embolization Device is an effective treatment option for select intracranial aneurysms. However, concerns for the patency of eloquent branch arteries covered by the Pipeline Embolization Device have been raised. We aimed to examine the patency of the anterior choroidal artery and clinical sequelae after ICA aneurysm treatment. MATERIALS AND METHODS: We prospectively analyzed all patients among our first 157 patients with ICA aneurysms treated by the Pipeline Embolization Device who required placement of at least 1 device across the ostium of the anterior choroidal artery. The primary outcome measure was angiographic patency of the anterior choroidal artery at last follow-up. Age, sex, type of aneurysm, neurologic examination data, number of Pipeline Embolization Devices used, relationship of the anterior choroidal artery to the aneurysm, and completeness of aneurysm occlusion on follow-up angiograms were also analyzed. RESULTS: Twenty-nine aneurysms requiring placement of at least 1 Pipeline Embolization Device (median = 1, range = 1-3) across the anterior choroidal artery ostium were identified. At angiographic follow-up (mean = 15.1 months; range = 12-39 months), the anterior choroidal artery remained patent, with antegrade flow in 28/29 aneurysms (96.5%), while 24/29 (82.7%) of the target aneurysms were angiographically occluded by 1-year follow-up angiography. Anterior choroidal artery occlusion, with retrograde reconstitution of the vessel, was noted in a single case. A significant correlation between the origin of the anterior choroidal artery from the aneurysm dome and failure of the aneurysms to occlude following treatment was found. CONCLUSIONS: After placement of 36 Pipeline Embolization Devices across 29 anterior choroidal arteries (median = 1 device, range = 1-3 devices), 1 of 29 anterior choroidal arteries was found occluded on angiographic follow-up. The vessel occlusion did not result in persistent clinical sequelae. Coverage of the anterior choroidal artery origin with the Pipeline Embolization Device, hence, may be considered reasonably safe when deemed necessary for aneurysm treatment.
PMID: 25572948
ISSN: 0195-6108
CID: 1432982

Cavernous Carotid Aneurysms in the Era of Flow Diversion: A Need to Revisit Treatment Paradigms

Tanweer, O; Raz, E; Brunswick, A; Zumofen, D; Shapiro, M; Riina, H A; Fouladvand, M; Becske, T; Nelson, P K
BACKGROUND AND PURPOSE: Recent techniques of endoluminal reconstruction with flow-diverting stents have not been incorporated into treatment algorithms for cavernous carotid aneurysms. This study examines the authors' institutional experience and a systematic review of the literature for outcomes and complications using the Pipeline Embolization Device in unruptured cavernous carotid aneurysms. MATERIALS AND METHODS: A retrospective search for cavernous carotid aneurysms from a prospectively collected data base of aneurysms treated with the Pipeline Embolization Device at our institution was performed. Baseline demographic, clinical, and laboratory values; intrainterventional data; and data at all follow-up visits were collected. A systematic review of the literature for complication data was performed with inquiries sent when clarification of data was needed. RESULTS: Forty-three cavernous carotid aneurysms were included in the study. Our mean radiographic follow-up was 2.05 years. On last follow-up, 88.4% of the aneurysms treated had complete or near-complete occlusion. Aneurysm complete or near-complete occlusion rates at 6 months, 12 months, and 36 months were 81.4%, 89.7%, and 100%, respectively. Of patients with neuro-ophthalmologic deficits on presentation, 84.2% had improvement in their visual symptoms. Overall, we had a 0% mortality rate and a 2.3% major neurologic complication rate. Our systematic review of the literature yielded 227 cavernous carotid aneurysms treated with the Pipeline Embolization Device with mortality and morbidity rates of 0.4% and 3.1%, respectively. CONCLUSIONS: Endoluminal reconstruction with flow diversion for large unruptured cavernous carotid aneurysms can yield high efficacy with low complications. Further long-term data will be helpful in assessing the durability of the cure; however, we advocate a revisiting of current management paradigms for cavernous carotid aneurysms.
PMID: 25147199
ISSN: 0195-6108
CID: 1165082