Try a new search

Format these results:

Searched for:

in-biosketch:true

person:grosse01

Total Results:

381


Failure of four bovine pericardial mitral prostheses

Saunders, Paul C; Grossi, Eugene A; Esposito, Rick A; Bizekis, Costas S; Strong, Michael D; Colvin, Stephen B
PMID: 14752441
ISSN: 0022-5223
CID: 42602

Advances in mitral valve reconstruction

Chapter by: Schwartz CF; Grossi EA; Sharony R; Saunders PC; Colvin SB; Galloway AC
in: Current therapy in thoracic and cardiovascular surgery by Yang SC; Cameron DE [Eds]
St. Louis : Mosby, 2004
pp. ?-?
ISBN: 0323014577
CID: 3836

Anterior leaflet resection of the mitral valve

Saunders, Paul C; Grossi, Eugene A; Schwartz, Charles F; Grau, Juan B; Ribakove, Greg H; Culliford, Alfred T; Applebaum, Robert M; Galloway, Aubrey C; Colvin, Steven B
Triangular resection is a reconstructive option for treatment of anterior leaflet mitral disease with segmental prolapse. In our experience, it is a safe and reproducible technique, associated with low rates of recurrent MR or need for reoperation, as well as decreased likelihood for systolic anterior motion after mitral repair. We review our experience with this technique over a 25-year experience with mitral valve reconstruction
PMID: 15197696
ISSN: 1043-0679
CID: 45685

Substernal epicardial echocardiography: review of a new technique [Case Report]

Reynolds, Harmony R; Nayar, Ambika C; McAleer, Eileen P; Schwartz, Jesse D; Tunick, Paul A; Applebaum, Robert M; Colvin, Stephen B; Culliford, Alfred T; Galloway, Aubrey C; Grossi, Eugene A; Ribakove, Gregory H; Kronzon, Itzhak
BACKGROUND: Patients after cardiac operation pose a challenge to the treating physician-these patients may become critically ill and are among the most difficult to image using transthoracic echocardiography. Several factors contribute to this, including difficulties in positioning the patient, inability of the patient to cooperate with instructions, surgical dressings, and hyperinflated lungs. Transesophageal echocardiography may be performed when transthoracic echocardiography is not diagnostic; however, transesophageal echocardiography is semi-invasive and does not lend itself to prolonged or repeated monitoring. METHODS: Recently, a new approach to echocardiography for use in the patient after operation has been introduced with the modification of the standard mediastinal drainage tube to allow for substernal epicardial echocardiography (SEE). The SEE tube has 2 lumens. The first allows for routine mediastinal drainage and the second has a blind end that permits the insertion of a standard transesophageal echocardiographic probe for high-resolution imaging as often as is desired over the period during which the mediastinal tube is in place. CONCLUSION: This article reviews the technique of SEE including a description of the method of performance of SEE (with representative images), a review of the published literature on this new modality, examples of clinical use, and a discussion of the advantages, indications, and limitations of SEE with an eye toward future directions for research
PMID: 14608297
ISSN: 0894-7317
CID: 42051

Transatrial dual chamber biventricular pacemaker-defibrillator placement in a patient with SVC obstruction [Case Report]

Pua, Bradley B; Saunders, Paul C; Lapietra, Angelo; Colvin, Stephen B; Collins, Jack; Grossi, Eugene A
A patient with severe congestive heart failure and obstruction of the superior vena cava required biventricular pacing and ICD therapy. Via right minithoracotomy, a transatrial approach for lead placement was successfully utilized to provide cardiac resynchronization and ICD placement. This technique for pacing lead placement is reviewed and its application for biventricular pacemaker-defibrillator placement is reported
PMID: 14516350
ISSN: 0147-8389
CID: 39051

Minimally invasive aortic valve surgery in the elderly: a case-control study

Sharony, Ram; Grossi, Eugene A; Saunders, Paul C; Schwartz, Charles F; Ribakove, Greg H; Culliford, Alfred T; Ursomanno, Patricia; Baumann, F Gregory; Galloway, Aubrey C; Colvin, Stephen B
INTRODUCTION: Although minimally invasive aortic valve surgery (MIAVR) is performed in many centers, few studies have compared its results to a standard sternotomy (SS) approach. We assessed the hypothesis that, when compared with SS in the elderly population, MIAVR has similar morbidity and mortality and allows faster hospital recovery. METHODS AND RESULTS: From January 1995 through February 2002, 515 patients over age 65 underwent isolated aortic valve replacement. Using data gathered prospectively, 189 MIAVR patients were matched with 189 SS patients by age, ventricular function, valvular pathology, urgency of operation, diabetes, previous cardiac surgery, renal disease, and history of stroke. In each group, 56.1% of patients underwent non-elective procedures, and 28% were >or=80 years old. Hospital mortality (6.9%) and freedom from postoperative morbidity (82.5% versus 81.5%, P=0.79) were similar. Multivariate analysis revealed that urgent procedures [Odds Ratio (OR)=3.97; P=0.03], congestive heart failure (OR=3.94; P=0.03), and ejection fraction <30% (OR=4.16; P=0.03) were significant predictors of hospital mortality. Prolonged length of stay was associated with age (P=0.05), preoperative stroke (OR=3.5,P=0.001), CHF (OR=2.2, P=0.004), and sternotomy approach (OR=2.3,P=0.002) by multivariate analysis. More MIAVR patients were discharged home (52.6% versus 38.6%,P=0.03) rather than to rehabilitation facilities. Three year actuarial survival revealed no difference between groups. CONCLUSIONS: Minimally invasive aortic valve surgery is safe in elderly patients, with morbidity and mortality comparable to sternotomy approach. The shorter hospital stay and greater percentage of patients discharged home after MIAVR reflect enhanced recovery with this technique
PMID: 12970207
ISSN: 1524-4539
CID: 39075

Off-pump coronary artery bypass grafting reduces mortality and stroke in patients with atheromatous aortas: a case control study

Sharony, Ram; Bizekis, Costas S; Kanchuger, Marc; Galloway, Aubrey C; Saunders, Paul C; Applebaum, Robert; Schwartz, Charles F; Ribakove, Greg H; Culliford, Alfred T; Baumann, F Gregory; Kronzon, Itzhak; Colvin, Stephen B; Grossi, Eugene A
BACKGROUND: Patients with severe atheromatous aortic disease (AAD) who undergo coronary artery bypass (CABG) have an increased risk of death and stroke. We hypothesized that in these high risk patients, off-pump coronary artery bypass (OPCAB) technique is associated with lower morbidity and mortality. METHODS AND RESULTS: Between June 1993 and January 2002, 5737 patients undergoing CABG had routine intra-operative TEE with 913 (15.9%) found to have severe AAD in the aortic arch or ascending aorta. Of these, 211 patients who underwent OPCAB were matched with 211 on-pump CABG patients by age, ejection fraction, history of stroke, cerebrovascular disease, diabetes, renal disease, nonelective operation, and previous cardiac surgery. Hospital mortality was 11.4% (24/211) for on-pump CABG and 3.8% (8/211) for OPCAB (P=0.003). Multivariate analysis revealed that increased mortality was associated with on-pump CABG (P=0.001), acute MI (P=0.03), number of grafts (P=0.01), age (P=0.01), history of stroke or cerebrovascular disease (P=0.04), CHF (P=0.02), and peripheral vascular disease (P=0.03). Multivariate analysis showed that OPCAB technique was associated with decreased stroke (P=0.05). Freedom from any complication was 78.7% for on-pump CABG and 91.9% for OPCAB (P<0.001). At 36 month follow-up multivariate analysis revealed that increased mortality was associated with age (P=0.001), previous MI (P=0.03), and renal disease (P=0.04), whereas increased survival was associated with increased number of grafts (P=0.001) and OPCAB (P=0.01). CONCLUSIONS: OPCAB surgery in patients with severe AAD is associated with lower risk of death, stroke and complications and improved mid-term survival. Routine intra-operative TEE allows identification of these patients and directs choice of appropriate surgical technique
PMID: 12970201
ISSN: 1524-4539
CID: 39076

Mitral valve in ischemic versus idiopathic dilated cardiomyopathy [Letter]

Grossi, Eugene A; Sharony, Ram; Colvin, Stephen B
PMID: 14502200
ISSN: 0022-5223
CID: 78732

Activation of mitogen-activated protein kinases during preparation of vein grafts and modulation by a synthetic inhibitor

Bizekis, Costas; Pintucci, Giuseppe; Derivaux, Christopher C; Saponara, Fiorella; Kim, Jin-Hee; Hyman, Kevin M; Sharony, Ram; Grossi, Eugene A; Baumann, F Gregory; Mignatti, Paolo; Galloway, Aubrey C
OBJECTIVE: Long-term durability of saphenous vein grafts used for coronary artery bypass grafting is limited by neointimal formation. Arterial vascular injury is known to activate intracellular mitogen-activated protein kinases, including extracellular signal-regulated kinases and c-jun N-terminal kinases, that affect cell differentiation, proliferation, migration, and apoptosis. This study tests the hypothesis that these mitogen-activated protein kinases are activated in saphenous veins during preparation for coronary artery bypass grafting. METHODS: Saphenous veins were harvested from 10 patients undergoing coronary artery bypass grafting. A specimen from each vein was placed in ice-cold lysis buffer immediately after harvesting (t = 0). The remaining tissue was incubated at room temperature in normal saline, 0.1% dimethylsulfoxide (vehicle), or 50 mmol/L PD98059 (mitogen-activated protein kinase kinase-1/2 inhibitor) until the vein was grafted (mean 50 minutes). To study kinetics of intracellular signaling pathways, canine saphenous veins were harvested, and mitogen-activated protein kinases and PI-3 kinase pathways were studied after different incubation time intervals. Extracted proteins were analyzed by Western blotting or in vitro kinase assay. RESULTS: The human saphenous veins showed elevated levels of active extracellular signal-regulated kinase after harvesting (t = 0) and prior to implant (t = 1). Incubation with PD98059 resulted in decreased activation of extracellular signal-regulated kinase. Kinetics of canine saphenous veins showed extracellular signal-regulated kinase and c-jun N-terminal kinase activation, in a time-dependent manner, along with activation of the growth factor-regulated PI3 kinase pathway. CONCLUSIONS: This study characterizes activation of extracellular signal-regulated kinases and c-jun N-terminal kinases during vein graft preparation and demonstrates the ability to inhibit extracellular signal-regulated kinase activation by simple incubation with a specific inhibitor. Further studies are needed to evaluate the significance of these findings with respect to graft durability.
PMID: 14502136
ISSN: 0022-5223
CID: 156047

Routine intraoperative transesophageal echocardiography identifies patients with atheromatous aortas: Impact on "off-pump" coronary artery bypass and perioperative stroke

Grossi, Eugene A; Bizekis, Costas S; Sharony, Ram; Saunders, Paul C; Galloway, Aubrey C; Lapietra, Angelo; Applebaum, Robert M; Esposito, Rick A; Ribakove, Greg H; Culliford, Alfred T; Kanchuger, Marc; Kronzon, Itzhak; Colvin, Stephen B
BACKGROUND: Patients with severe atheromatous aortic disease (AAD) undergoing coronary artery bypass grafting (CABG) have increased operative risks. The 'off-pump' CABG (OPCAB) technique was evaluated in patients given the diagnosis of severe AAD by routine transesophageal echocardiography. METHODS: A total of 5737 patients underwent CABG, with 913 having transesophageal echocardiography findings of severe AAD. Of the patients with severe AAD, 678 (74.3%) had conventional CABG and 235 (25.7%) had OPCAB. RESULTS: Hospital mortality was 8.7% for conventional CABG and 5.1% for OPCAB (P =.08). Multivariate analysis revealed that increased mortality was significantly associated with acute myocardial infarction, conventional CABG, age, renal disease, history of stroke, and ejection fraction < 30%. Neurologic complications occurred in 6.3% of patients undergoing CABG and in 2.1% undergoing OPCAB (P =.01). Freedom from any complication was significantly greater with OPCAB. CONCLUSION: Routine intraoperative transesophageal echocardiography identifies patients with severe AAD. In these patients, OPCAB technique is associated with a lower risk of death, stroke, and all complications
PMID: 12835662
ISSN: 0894-7317
CID: 36724