Try a new search

Format these results:

Searched for:

in-biosketch:true

person:moyl02

Total Results:

263


Stimulated echo diffusion tensor imaging (STEAM-DTI) with varying diffusion times as a probe of breast tissue

Teruel, Jose R; Cho, Gene Y; Moccaldi Rt, Melanie; Goa, Pal E; Bathen, Tone F; Feiweier, Thorsten; Kim, Sungheon G; Moy, Linda; Sigmund, Eric E
PURPOSE: To explore the application of diffusion tensor imaging (DTI) for breast tissue and breast pathologies using a stimulated-echo acquisition mode (STEAM) with variable diffusion times. MATERIALS AND METHODS: In this Health Insurance Portability and Accountability Act-compliant study, approved by the local institutional review board, eight patients and six healthy volunteers underwent an MRI examination at 3 Tesla including STEAM-DTI with several diffusion times ranging from 68.5 to 902.5 ms. A DTI model was fitted to the data for each diffusion time, and parametric maps of mean diffusivity, fractional anisotropy, axial diffusivity, and radial diffusivity were computed for healthy fibroglandular tissue (FGT) and lesions. The median value of radial diffusivity for FGT was fitted to a linear decay to obtain an estimation of the surface-to-volume ratio, from which the radial diameter was calculated. RESULTS: For healthy FGT, radial diffusivity presented a linear decay with the square root of the diffusion time resulting in a range of estimated radial diameters from 202 to 496 microm, while axial diffusivity presented a nearly time-independent diffusion. Residual fat signal was reduced at longer diffusion times due to the shorter T1 of fat. Residual fat signal to the overall signal in the healthy volunteers' FGT was found to range from 2.39% to 2.55% (shortest mixing time), and from 0.40% to 0.51% (longest mixing time) for the b500 images. CONCLUSION: The use of variable diffusion times may provide an in vivo noninvasive tool to probe diffusion lengths in breast tissue and breast pathology, and might aid by improving fat suppression at longer diffusion times. J. Magn. Reson. Imaging 2016.
PMID: 27441890
ISSN: 1522-2586
CID: 2185552

Background parenchymal enhancement over exam time in patients with and without breast cancer

Melsaether, Amy; Pujara, Akshat C; Elias, Kristin; Pysarenko, Kristine; Gudi, Anjali; Dodelzon, Katerina; Babb, James S; Gao, Yiming; Moy, Linda
PURPOSE: To compare background parenchymal enhancement (BPE) over time in patients with and without breast cancer. MATERIALS AND METHODS: This retrospective Institutional Review Board (IRB)-approved, Health Insurance Portability and Accountability Act (HIPAA)-compliant study included 116 women (25-84 years, mean 54 years) with breast cancer who underwent breast magnetic resonance imaging at 3T between 1/2/2009 and 12/29/2009 and 116 age and date-of-exam-matched women without breast cancer (23-84 years, mean 51 years). Two independent, blinded readers (R1, R2) recorded BPE (minimal, mild, moderate, marked) at three times (100, 210, and 320 seconds postcontrast). Subsequent cancers were diagnosed in 9/96 control patients with follow up (12.6-93.0 months, mean 63.6 months). Exact Mann-Whitney, Fisher's exact, and McNemar tests were performed. RESULTS: Mean BPE was not found to be different between patients with and without breast cancer at any time (P = 0.36-0.64). At time 2 as compared with time 1, there were significantly more patients, both with and without breast cancer, with BPE >minimal (R1: 90 vs. 41 [P < 0.001] and 81 vs. 36 [P < 0.001]; R2: 84 vs. 52 [P < 0.001] and 79 vs. 43 [P < 0.001]) and BPE >mild (R1: 59 vs. 10 [P < 0.001] and 47 vs. 13 [P < 0.001]; R2: 49 vs. 12 [P < 0.001] and 41 vs. 18 [P < 0.001]). BPE changes between times 2 and 3 were not significant (P = 0.083-1.0). Odds ratios for control patients developing breast cancer were significant only for R2 and ranged up to 7.67 (1.49, 39.5; P < 0.01) for BPE >mild at time 2. CONCLUSION: BPE changes between the first and second postcontrast scans and stabilizes thereafter in most patients. Further investigation into the most clinically relevant timepoint for BPE assessment is warranted. J. Magn. Reson. Imaging 2016.
PMID: 27285396
ISSN: 1522-2586
CID: 2136622

Breast MRI Screening: Benefits and Limitations

Heller, Samantha L.; Moy, Linda
ISI:000387412300009
ISSN: 1943-4588
CID: 4448192

ACR Appropriateness Criteria Stage I Breast Cancer: Initial Workup and Surveillance for Local Recurrence and Distant Metastases in Asymptomatic Women

Moy, Linda; Newell, Mary S; Mahoney, Mary C; Bailey, Lisa; Barke, Lora D; Carkaci, Selin; D'Orsi, Carl; Goyal, Sharad; Haffty, Bruce G; Harvey, Jennifer A; Hayes, Mary K; Jokich, Peter M; Lee, Su-Ju; Mainiero, Martha B; Mankoff, David A; Patel, Samir B; Yepes, Monica M
Women newly diagnosed with stage 1 breast cancer have an early-stage disease that can be effectively treated. Evidence provides little justification for performing imaging to exclude metastasis in asymptomatic women with stage I breast cancer. No differences have been found in survival or quality of life in women regardless of whether they underwent initial workup for metastatic disease. These women generally prefer intensive follow-up to detect an early recurrence. However, survival rates do not differ between women who obtain intensive screening and surveillance, with imaging and laboratory studies, and women who undergo testing only as a result of development of symptoms or findings on clinical examinations. In addition, quality of life is similar for women who undergo intensive surveillance compared with those who do not. American Society of Clinical Oncology and National Comprehensive Cancer Network guidelines state that annual mammography is the only imaging examination that should be performed to detect a localized breast recurrence in asymptomatic patients. Additional imaging may be needed if the patient has locoregional symptoms. The ACR Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed every 3 years by a multidisciplinary expert panel. The guideline development and review by the panel include extensive analysis of current medical literature from peer-reviewed journals and application of a well-established consensus methodology (modified Delphi) to rate the appropriateness of imaging and treatment procedures. When evidence is lacking or not definitive, expert opinion may be used to recommend imaging or treatment.
PMID: 27814823
ISSN: 1558-349x
CID: 2303932

The relationship of obesity, mammographic breast density, and magnetic resonance imaging in patients with breast cancer

Gillman, Jennifer; Chun, Jennifer; Schwartz, Shira; Schnabel, Freya; Moy, Linda
PURPOSE: The purpose was to evaluate the relationship between body mass index (BMI), mammographic breast density, magnetic resonance (MR) background parenchymal enhancement (BPE), and MR fibroglandular tissue (FGT) in women with breast cancer. METHODS: Our institutional database was queried for patients with preoperative mammography and breast MR imaging. RESULTS: There were 573 women eligible for analysis. Elevated BMI was associated with advanced stage of disease (P=.01), lower mammographic density (P<.0001), lower FGT (P<.0001), higher BPE (P=.005), and nonpalpable lesions (P=.04). CONCLUSIONS: Higher BMI was associated with decreased breast density and FGT. Higher BMI was also associated with advanced stage disease and nonpalpable tumors on clinical exam.
PMID: 27572282
ISSN: 1873-4499
CID: 2232442

Role of Breast MRI in Patients with Newly Diagnosed Breast Cancer

L , Albert M; Gao, Y; Moy, L
The role of breast MRI in patients with newly diagnosed breast cancer is controversial. Preoperative MRI is highly sensitive and accurate in assessing tumor size, extensive intraductal component (EIC), and in detection of additional sites of disease. It also has utility in assessing chest wall, nipple-areolar complex, and nodal involvement. Yet there are conflicting results in whether the use of preoperative MRI improves re-excision rate, local recurrence rate, and ultimately, survival. MRI has also been associated with overestimation of disease and increased mastectomy rates, and may contribute to treatment delay. Nevertheless, certain subgroups of patients may benefit more from preoperative MRI than others, including those with invasive lobular cancer (ILC), dense breasts, and those at elevated risk for breast cancer
EMBASE:20160301764
ISSN: 1943-4596
CID: 2161442

Outcomes of Preoperative MRI-Guided Needle Localization of Nonpalpable Mammographically Occult Breast Lesions

Gao, Yiming; Bagadiya, Neeti R; Jardon, Meghan L; Heller, Samantha L; Melsaether, Amy N; Toth, Hildegard B; Moy, Linda
OBJECTIVE: MRI-guided needle localization allows access to MRI-detected mammographically occult breast lesions that are not amenable to MRI-guided biopsy. The purpose of this study was to examine the safety and outcomes of MRI-guided needle localization. MATERIALS AND METHODS: Ninety-nine consecutive breast lesions that underwent preoperative MRI-guided needle localization were identified. Clinical indications for breast MRI, reasons for performing MRI-guided needle localization, and surgical pathology results were recorded. Lesion characteristics, procedure time, and complications were assessed. RESULTS: Of 99 lesions, 60 (60.6%) were in a location inaccessible for MRI biopsy, necessitating MRI-guided needle localization. Histologic evaluation revealed 38 (38.4%) carcinomas, 31 (31.3%) high-risk lesions, and 30 (30.3%) benign lesions. Carcinoma was more likely to be found in women with known cancer (31/61 [50.8%]; p = 0.003) than in women undergoing imaging for high-risk screening (2/18 [11.1%]) or problem solving (6/20 [30%]). Masses (p = 0.013) and foci (p < 0.001) were more likely to be malignant than were lesions with nonmass enhancement. Foci were significantly more often malignant compared with all other lesion types (9/10 [90%]; p < 0.001). The mean (+/- SD) procedure time was 32.9 +/- 9.39 minutes. All lesions were occult on specimen radiographs. There were no procedure-related complications. CONCLUSION: The positive predictive value of MRI-guided needle localization (38.4%) is comparable to that of mammography- and tomosynthesis-guided localizations and is highest in women with a known diagnosis of cancer. It is highly accurate in targeting small enhancing lesions, thereby improving surgical management. MRI-guided needle localization is a safe, accurate, and time-efficient procedure.
PMID: 27275652
ISSN: 1546-3141
CID: 2136442

Evaluation of Breast Lipid Composition in Patients with Benign Tissue and Cancer by Using Multiple Gradient-Echo MR Imaging

Freed, Melanie; Storey, Pippa; Lewin, Alana Amarosa; Babb, James; Moccaldi, Melanie; Moy, Linda; Kim, Sungheon G
Purpose To demonstrate the feasibility of the use of a rapid, noninvasive, in vivo imaging method to measure fatty acid fractions of breast adipose tissue during diagnostic breast magnetic resonance (MR) examinations and to investigate associations between fatty acid fractions in breast adipose tissue and breast cancer status by using this method. Materials and Methods The institutional review board approved this retrospective HIPAA-compliant study and informed consent was waived. Between July 2013 and September 2014, multiple-echo three-dimensional gradient-echo data were acquired for 89 women. Spectra were generated and used to estimate fractions of monounsaturated fatty acid (MUFA), polyunsaturated fatty acid (PUFA), and saturated fatty acid (SFA) in the breast adipose tissue. Analysis of covariance and exact Mann-Whitney tests were used to compare groups and the Spearman rank correlation coefficient was used to characterize the association of each imaging measure with each attribute. Results For postmenopausal women, MUFA was lower (0.38 +/- 0.06 vs 0.46 +/- 0.10; P < .05) and SFA was higher (0.31 +/- 0.07 vs 0.19 +/- 0.11; P < .05) for women with invasive ductal carcinoma than for those with benign tissue. No correlation was found between body mass index (BMI) and fatty acid fractions in breast adipose tissue. In women with benign tissue, postmenopausal women had a higher PUFA (0.35 +/- 0.06 vs 0.27 +/- 0.05; P < .01) and lower SFA (0.19 +/- 0.11 vs 0.30 +/- 0.12; P < .05) than premenopausal women. Conclusion There is a possible link between the presence of invasive ductal carcinoma and fatty acid fractions in breast adipose tissue for postmenopausal women in whom BMI values are not correlated with the fatty acid fractions. (c) RSNA, 2016 Online supplemental material is available for this article.
PMCID:5047128
PMID: 27266558
ISSN: 1527-1315
CID: 2136342

Assessment of Aggressiveness of Breast Cancer Using Simultaneous 18F-FDG-PET and DCE-MRI: Preliminary Observation

Margolis, Nathaniel E; Moy, Linda; Sigmund, Eric E; Freed, Melanie; McKellop, Jason; Melsaether, Amy N; Kim, Sungheon Gene
PURPOSE: This study aims to investigate the feasibility of using simultaneous breast MRI and PET to assess the synergy of MR pharmacokinetic and fluorine-18 fluorodeoxyglucose (F-FDG) uptake data to characterize tumor aggressiveness in terms of metastatic burden and Ki67 status. METHODS: Twelve consecutive patients underwent breast and whole-body PET/MRI. During the MR scan, PET events were simultaneously accumulated. MR contrast kinetic model parametric maps were computed using the extended Tofts model, including the volume transfer constant between blood plasma and the interstitial space (K), the transfer constant from the interstitial space to the blood plasma (kep), and the plasmatic volume fraction (Vp). RESULTS: Patients with systemic metastases had a significantly lower kep compared to those with local disease (0.45 vs. 0.99 min, P = 0.011). Metastatic burden correlated positively with K and standardized uptake value (SUV), and negatively with kep. Ki67 positive tumors had a significantly greater K compared to Ki67 negative tumors (0.29 vs. 0.45 min, P = 0.03). A negative correlation was found between metabolic tumor volume and transfer constant (K or Kep). CONCLUSION: These preliminary results suggest that MR pharmacokinetic parameters and FDG-PET may aid in the assessment of tumor aggressiveness and metastatic potential. Future studies are warranted with a larger cohort to further assess the role of pharmacokinetic modeling in simultaneous PET/MRI imaging.
PMCID:4935605
PMID: 27187730
ISSN: 1536-0229
CID: 2112162

Frequency of Discordant Lesions and False-negative Cancers at Stereotactic Vacuum-assisted Biopsy

Heller, Samantha L; Jaglan, Sonam; Babb, James S; Melsaether, Amy; Toth, Hildegard B; Moy, Linda
RATIONALE AND OBJECTIVES: This study aimed to determine frequency of discordant lesions and discordant false-negative cancers at stereotactic vacuum-assisted biopsy (SVAB). MATERIALS AND METHODS: Institutional database was searched for discordant SVAB results between January 1, 2005 and December 31, 2012, in this retrospective institutional review board-approved Health Insurance Portability and Accountability Act-compliant study. Patient age, indication for initial mammogram, breast density, lesion size, Breast Imaging Reporting and Data System categorization, operator experience, biopsy needle gauge, biopsy histology, and final surgical histology of discordant lesions were collected and entered into a Microsoft Excel spreadsheet. Discordant rate and false-negative rates were calculated. Fisher exact test was used to assess prevalence of discordance using 11-Gauge needles versus 9-Gauge needles. Patient age, lesion Breast Imaging Reporting and Data System, operator days of experience, mammographic density, and lesion size were evaluated for association with false-negative discordant lesions using an exact Mann-Whitney U test. RESULTS: A total of 1861 SVABs were performed, 224 (12%) with an 11-Gauge VAB device and 1637 (88%) with a 9G Suros or Eviva device. Majority (1409 of 1861; 76%) of SVABs targeted calcifications. Twenty-three of 1861 (1.2%) discordant lesions were identified in 23 women. Seven of 23 (30%) discordant lesions were found to be cancers after final surgical pathology. Needle gauge was not associated with discordance. Operator experience was not associated with false-negative discordance. CONCLUSIONS: A relatively low discordance rate (1.2%) was observed. However, a high percentage (30%; range in literature 11.7%-53.8%) of our discordant lesions were false negatives. This study emphasizes the need for careful radiological-pathologic review after SVAB and for repeat biopsy or surgical excision in the setting of discordance.
PMID: 27161209
ISSN: 1878-4046
CID: 2107512