Searched for: in-biosketch:true
person:agulnm01
Spinal reconstruction for osteomyelitis with free vascularized fibular grafts using intra-abdominal recipient vessels: A series of three cases
Aliano, Kristen A; Agulnick, Marc; Cohen, Benjamin; Gonya, Gary; Low, Christopher; Stavrides, Steve; Addona, Tommaso; Goncalves, John; Shin, David; Kilgo, Matthew S; Davenport, Thomas A
Reconstruction of bony defects in the surgical management of vertebral osteomyelitis is a challenging endeavor. Our objective is to report the use of intra-abdominal vessels as the recipient vessels for microanastomosis of vascularized bone graft and the use of a spinal cage for fixation. Three patients failed conservative treatment for vertebral osteomyelitis and suffered pathologic fracture. Their treatment consisted of staged posterior irrigation and debridement with segmental fixation, followed by a thoracoabdominal approach multiple-level corpectomy. Reconstruction was performed with a free vascularized fibular graft placed within a custom, expandable cage. The vascularized fibular graft was anastomosed to an intra-abdominal recipient vessel. All patients improved clinically with no neurologic deficits noted. All showed evidence of successful fusion. Free vascularized bone grafts continue to be an excellent option for multi-level spinal defects related to osteomyelitis. Intra-abdominal recipient vessels are appropriate recipient vessels, as their diameter, length, and accessibility allow vascularized bone graft reconstruction of vertebral column defects of the thoracolumbar region. These vessels are also easily accessible and the anastomoses can be performed in the superficial operating incision.
PMID: 24014308
ISSN: 1098-2752
CID: 3508852
Prophylactic inferior vena cava filters prevent pulmonary embolisms in high-risk patients undergoing major spinal surgery
Dazley, Justin M; Wain, Reese; Vellinga, Ryan M; Cohen, Benjamin; Agulnick, Marc A
STUDY DESIGN/METHODS:Clinical case series. OBJECTIVE:To show the efficacy of prophylactic inferior vena cava (IVC) filters in preventing venous thromboembolic event (VTE) in high-risk patients undergoing major spinal surgery. SUMMARY OF BACKGROUND DATA/BACKGROUND:Patients undergoing major spinal surgery are at increased risk for VTEs. Recent studies have shown IVC filters are effective in preventing clinically significant pulmonary embolism (PE), but have not documented the frequency of all emboli prevented. METHODS:Patients undergoing major spinal surgery from 2006 to 2009, having IVC filters placed for VTE prophylaxis, were reviewed. Patients with 2 or more risk factors for VTE were included and their perioperative courses were reviewed for PE and device-related complications. Cavograms obtained at the time of attempted filter retrieval identified intercepted emboli. The rates of intercepted emboli and clinical PEs were compared with those of similar populations undergoing similar procedures. RESULTS:Approximately 17% of patients had entrapped thrombus present at attempted filter retrieval. An additional 17% of filters were unable to be retrieved due to change in position within the IVC. No patients experienced symptomatic PE. One patient developed a deep vein thrombus requiring pharmacologic treatment and another patient developed superficial phlebitis. There were no complications related to IVC filter use. CONCLUSIONS:These findings show that the decreased rate of PE observed in this and other series is likely because of the use of IVC filters, rather than sampling bias inherent when studying a relatively rare problem. The safety of IVC filters in this population is also confirmed. The observed rate of clinical PE is consistent with other published series. Emboli intercepted by filters may more accurately estimate clinically significant emboli prevented. Therefore, cavograms may prove to be a valuable method of assessing the efficacy of these devices in future studies.
PMID: 21423052
ISSN: 1539-2465
CID: 5022682
Biomechanical evaluation of surgical constructs for stabilization of cervical teardrop fractures
Ianuzzi, Allyson; Zambrano, Isidoro; Tataria, Jigar; Ameerally, Azeema; Agulnick, Marc; Goodwin, Jesse S Little; Stephen, Mark; Khalsa, Partap S
BACKGROUND CONTEXT/BACKGROUND:Cervical flexion teardrop fractures (CFTF) are highly unstable injuries, and the optimal internal fixation construct is not always clearly indicated. PURPOSE/OBJECTIVE:The purpose of the current study was to determine whether the type of fixation construct (anterior, posterior, or combined) or number of joint levels involved in fixation (one or two) affected the relative stability of a CFTF injury at C5-C6. STUDY DESIGN/SETTING/METHODS:Human cadaveric cervical spine specimens were mechanically tested under displacement control in the intact state and after creation of CFTF at C5-C6 with stabilization using five different instrumentation constructs. Joint stiffness and intervertebral translation of the constructs were compared with the intact state and normalized (instrumented/intact) to assess relative differences across the five constructs. METHODS:Spine specimens were mechanically tested in the intact state during flexion, extension, lateral bending, and axial rotation. CFTF was created at C5-C6 by creating an osteotomy at C5 and transecting the posterior ligaments and intervertebral disc. Specimens were tested with anterior, posterior, and combined single-level constructs (C5-C6). Then, a corpectomy was performed at C5, and specimens were retested with the two-level constructs (C4-C6; anterior and anterior-posterior). Joint stiffness and intervertebral translations were computed. RESULTS:All five fixation constructs resulted in joint stability that was as good as or better than that of the intact specimens. Relative stiffness of the constructs differed depending upon the motion type considered, though the two-level anterior-posterior construct typically provided the greatest stability. Intervertebral translation along the major axis was reduced the most for both of the combined instrumentation systems, although there were few changes in total intervertebral translation across the five constructs. CONCLUSIONS:All five constructs restored stability comparable to that of the intact specimens. The significance of the relative differences in constructs for the in vivo spine is unclear and warrants further clinical investigation.
PMID: 16934720
ISSN: 1529-9430
CID: 5022672