Try a new search

Format these results:

Searched for:

in-biosketch:true

person:bergek01

Total Results:

161


Validation of a Novel Compact System for the Measurement of Lung Volumes

Berger, Kenneth I; Adam, Ori; Dal Negro, Roberto Walter; Kaminsky, David A; Shiner, Robert J; Burgos, Felip; de Jongh, Frans H C; Cohen, Inon; Fredberg, Jeffrey J
BACKGROUND:Current techniques for measuring absolute lung volumes rely on bulky and expensive equipment and are complicated to use for the operator and the patient. A novel method for measurement of absolute lung volumes, the MiniBox method, is presented. RESEARCH QUESTION/OBJECTIVE:Across a population of patients and healthy participants, do values for total lung capacity (TLC) determined by the novel compact device (MiniBox, PulmOne Advanced Medical Devices, Ltd.) compare favorably with measurements determined by traditional whole body plethysmography? STUDY DESIGN AND METHODS/METHODS:). RESULTS:was 7.0% in healthy participants. In obstructed patients, the NSD was 7.9% in mild obstruction and 9.1% in severe obstruction. In restricted patients, the NSD was 7.8% in mild restriction and 13.9% in moderate and severe restriction. No significant differences were found between TLC values obtained by the two measurement techniques. Also no significant differences were found in results obtained among the five centers. INTERPRETATION/CONCLUSIONS:TLC as measured by the novel MiniBox system is not significantly different from TLC measured by conventional whole body plethysmography, thus validating the MiniBox method as a reliable method to measure absolute lung volumes.
PMID: 33539839
ISSN: 1931-3543
CID: 4901182

Isolated small airway dysfunction in patients with unexplained dyspnea on exertion [Meeting Abstract]

Sharpe, A L; Weinstein, T; Reibman, J; Goldring, R M; Liu, M; Shao, Y; Oppenheimer, B W; Bohart, I; Berger, K I
Introduction: Exertional respiratory symptoms are prominent in patients with environmental lung injury following inhalation of World Trade Center dust. Baseline pulmonary function testing in these patients is frequently normal, leaving symptoms unexplained. Although small airway dysfunction has been identified at rest, its role in producing exertional symptoms is unclear. In this study exercise evaluation with assessment of airway function was employed to uncover mechanisms for exertional dyspnea.
Method(s): 27 subjects were studied: 20 with unexplained dyspnea (normal spirometry) and 6 asymptomatic controls. Baseline pulmonary function testing was conducted along with respiratory oscillometry to assess small airway function. An incremental exercise protocol was performed that included a focused evaluation of airway function: (1) examination of tidal flow vs. volume curves during exercise to assess for dynamic hyperinflation and expiratory flow limitation; and (2) airway reactivity post-exercise using spirometry and oscillometry. Baseline: By design spirometry values were within normal limits in all subjects. Symptomatic individuals tended to have greater mean R5, R20, R5-20, and AX at baseline compared with asymptomatic controls (R5: 4.80+/-1.79 vs. 3.66+/-1.06; R20: 3.52+/-1.12 vs. 2.98+/-0.68; R5-20: 1.28+/-1.02 vs. 0.70+/-0.53; AX: 13.44+/-10.74 vs. 5.48+/-5.21). Exercise: Dyspnea was reproduced with exercise in symptomatic subjects (mean Borg dyspnea score 1.38+/-1.48 at baseline, 4.20+/-2.28 at peak exercise). Asymptomatic controls did not report significant dyspnea (mean Borg dyspnea score 0 at baseline, 1.60+/-1.14 at peak exercise). Expiratory flow limitation during exercise was noted in 13/20 symptomatic subjects compared with 0 controls. Post Exercise: Bronchial hyper-reactivity was evident in post-exercise spirometry (>10% decline in FEV1) in 3/20 symptomatic subjects vs. 1/6 controls; the fall in FEV1 was predominantly attributable to a fall in FVC, consistent with small airway dysfunction. An additional six symptomatic subjects demonstrated isolated small airway hyper-reactivity that was only revealed on oscillometry.
Conclusion(s): In patients with unexplained dyspnea and normal spirometry, symptoms were reproduced during exercise. Focused airway assessment uncovered small airway dysfunction both during and following exercise that contributed to the development of dyspnea
EMBASE:635308122
ISSN: 1535-4970
CID: 4915612

Respiratory impedance measured using impulse oscillometry in a healthy urban population

Berger, Kenneth I; Wohlleber, Margaret; Goldring, Roberta M; Reibman, Joan; Farfel, Mark R; Friedman, Stephen M; Oppenheimer, Beno W; Stellman, Steven D; Cone, James E; Shao, Yongzhao
This study derives normative prediction equations for respiratory impedance in a healthy asymptomatic urban population using an impulse oscillation system (IOS). In addition, this study uses body mass index (BMI) in the equations to describe the effect of obesity on respiratory impedance. Data from an urban population comprising 472 healthy asymptomatic subjects that resided or worked in lower Manhattan, New York City were retrospectively analysed. This population was the control group from a previously completed case-control study of the health effects of exposure to World Trade Center dust. Since all subjects underwent spirometry and oscillometry, these previously collected data allowed a unique opportunity to derive normative prediction equations for oscillometry in an urban, lifetime non-smoking, asymptomatic population without underlying respiratory disease. Normative prediction equations for men and women were successfully developed for a broad range of respiratory oscillometry variables with narrow confidence bands. Models that used BMI as an independent predictor of oscillometry variables (in addition to age and height) demonstrated equivalent or better fit when compared with models that used weight. With increasing BMI, resistance and reactance increased compatible with lung and airway compression from mass loading. This study represents the largest cohort of healthy urban subjects assessed with an IOS device. Normative prediction equations were derived that should facilitate application of IOS in the clinical setting. In addition, the data suggest that modelling of lung function may be best performed using height and BMI as independent variables rather than the traditional approach of using height and weight.
PMCID:8005688
PMID: 33816605
ISSN: 2312-0541
CID: 4838882

Exercise-Induced Small Airway Dysfunction Detected by Oscillometry Uncovers Mechanisms for Unexplained Dyspnea [Meeting Abstract]

Sharpe, A. L.; Oppenheimer, B. W.; Goldring, R. M.; Sterman, D. H.; Addrizzo-Harris, D. J.; Weinstein, T.; Kwok, B.; Bohart, I.; Berger, K. I.
ISI:000685468904593
ISSN: 1073-449x
CID: 5266052

Airways Disease Presenting as Restrictive Impairment

Miller, Albert; Goldring, Roberta M; Berger, Kenneth I
PMID: 32755377
ISSN: 1535-4970
CID: 4554082

Respiratory function during enzyme replacement therapy in late-onset Pompe disease: longitudinal course, prognostic factors, and the impact of time from diagnosis to treatment start

Stockton, David W; Kishnani, Priya; van der Ploeg, Ans; Llerena, Juan; Boentert, Matthias; Roberts, Mark; Byrne, Barry J; Araujo, Roberto; Maruti, Sonia S; Thibault, Nathan; Verhulst, Karien; Berger, Kenneth I
OBJECTIVE:To examine respiratory muscle function among late-onset Pompe disease (LOPD) patients in the Pompe Registry (NCT00231400/Sanofi Genzyme) during enzyme replacement therapy (ERT) with alglucosidase alfa by assessing the longitudinal course of forced vital capacity (FVC), prognostic factors for FVC, and impact of time from diagnosis to ERT initiation. METHODS:Longitudinal FVC data from LOPD (symptom onset > 12 months or ≤ 12 months without cardiomyopathy) patients were analyzed. Patients had to have baseline FVC (percent predicted upright) assessments at ERT start and ≥ 2 valid post-baseline assessments. Longitudinal analyses used linear mixed-regression models. RESULTS:Among 396 eligible patients, median baseline FVC was 66.9% (range 9.3-126.0). FVC remained stable during the 5-year follow-up (slope = - 0.17%, p = 0.21). Baseline FVC was lower among various subgroups, including patients who were male; older at ERT initiation; had a longer duration from symptom onset to ERT initiation; and had more advanced disease at baseline (based on respiratory support use, inability to ambulate, ambulation device use). Age at symptom onset was not associated with baseline degree of respiratory dysfunction. Differences between subgroups observed at baseline remained during follow-up. Shorter time from diagnosis to ERT initiation was associated with higher FVC after 5 years in all patients and the above subgroups using a cut-off of 1.7 years. CONCLUSION/CONCLUSIONS:FVC stability over 5 years suggests that respiratory function is preserved during long-term ERT in real-world settings. Early initiation of alglucosidase alfa was associated with preservation of FVC in LOPD patients with better respiratory function at the time of treatment initiation.
PMID: 32524257
ISSN: 1432-1459
CID: 4489722

Characterization of Persistent Uncontrolled Asthma Symptoms in Community Members Exposed to World Trade Center Dust and Fumes

Reibman, Joan; Caplan-Shaw, Caralee; Wu, Yinxiang; Liu, Mengling; Amin, Milan R; Berger, Kenneth I; Cotrina-Vidal, Maria L; Kazeros, Angeliki; Durmus, Nedim; Fernandez-Beros, Maria-Elena; Goldring, Roberta M; Rosen, Rebecca; Shao, Yongzhao
The destruction of the World Trade Center (WTC) towers on the 11th of September, 2001 released a vast amount of aerosolized dust and smoke resulting in acute and chronic exposures to community members as well as responders. The WTC Environmental Health Center (WTC EHC) is a surveillance and treatment program for a diverse population of community members, including local residents and local workers with WTC dust exposure. Many of these patients have reported persistent lower respiratory symptoms (LRS) despite treatment for presumed asthma. Our goal was to identify conditions associated with persistent uncontrolled LRS despite standard asthma management. We recruited 60 patients who were uncontrolled at enrollment and, after a three-month run-in period on high-dose inhaled corticosteroid and long acting bronchodilator, reassessed their status as Uncontrolled or Controlled based on a score from the Asthma Control Test (ACT). Despite this treatment, only 11 participants (18%) gained Controlled status as defined by the ACT. We compared conditions associated with Uncontrolled and Controlled status. Those with Uncontrolled symptoms had higher rates of upper airway symptoms. Many patients had persistent bronchial hyper-reactivity (BHR) and upper airway hyper-reactivity as measured by paradoxical vocal fold movement (PVFM). We found a significant increasing trend in the percentage of Controlled with respect to the presence of BHR and PVFM. We were unable to identify significant differences in lung function or inflammatory markers in this small group. Our findings suggest persistent upper and lower airway hyper-reactivity that may respond to standard asthma treatment, whereas others with persistent LRS necessitate additional diagnostic evaluation, including a focus on the upper airway.
PMID: 32933057
ISSN: 1660-4601
CID: 4592962

Increased Dead Space Ventilation and Refractory Hypercapnia in Patients With Coronavirus Disease 2019: A Potential Marker of Thrombosis in the Pulmonary Vasculature [Case Report]

Oppenheimer, Beno W; Bakker, Jan; Goldring, Roberta M; Teter, Katherine; Green, David L; Berger, Kenneth I
Objectives/UNASSIGNED:Mortality rates in intubated coronavirus disease 2019 patients remain markedly elevated. Some patients develop sudden refractory hypercapnia and hypoxemia not explained by worsening pulmonary parenchymal disease. This case series highlights clinical findings and management of coronavirus disease 2019 patients with refractory hypercapnia despite maximal/optimal ventilatory support. Hypercapnia could not be explained by worsening lung disease or other common factors, and thus, a pulmonary vascular etiology was suggested. The pillars of management were targeted to improve pulmonary vascular patency via aggressive anticoagulation and support right ventricular function. Data Sources/UNASSIGNED:Four consecutive patients with confirmed coronavirus disease 2019 infection with sudden hypercapnia and hypoxemia were included. Data Synthesis/UNASSIGNED:removal was discontinued in three patients over the ensuing 3 weeks, and one patient was discharged home. Conclusions/UNASSIGNED:We speculate that thromboinflammation with pulmonary microvasculature occlusion leads to a sudden increase in dead space and shunt resulting in severe hypercapnia and hypoxemia in coronavirus disease 2019 patients. Early identification of these physiologic and clinical biomarkers could trigger the institution of therapies aiming to reverse the hypercoagulable state and support right ventricular function.
PMCID:7515611
PMID: 33063042
ISSN: 2639-8028
CID: 4641672

Small airway function in obese individuals with self-reported asthma

Oppenheimer, Beno W; Goldring, Roberta M; Soghier, Israa; Smith, David; Parikh, Manish; Berger, Kenneth I
Diagnosis of asthma in obese individuals frequently relies on clinical history, as airflow by spirometry may remain normal. This study hypothesised that obese subjects with self-reported asthma and normal spirometry will demonstrate distinct clinical characteristics, metabolic comorbidities and enhanced small airway dysfunction as compared with healthy obese subjects. Spirometry, plethysmography and oscillometry data pre/post-bronchodilator were obtained in 357 obese subjects in three groups as follows: no asthma group (n=180), self-reported asthma normal spirometry group (n=126), and asthma obstructed spirometry group (n=51). To assess the effects of obesity related to reduced lung volume, oscillometry measurements were repeated during a voluntary inflation to predicted functional residual capacity (FRC). Dyspnoea was equally prevalent in all groups. In contrast, cough, wheeze and metabolic comorbidities were more frequent in the asthma normal spirometry and asthma obstructed spirometry groups versus the no asthma group (p<0.05). Despite similar body size, oscillometry measurements demonstrated elevated R5-20 (difference between resistance at 5 and 20 Hz) in the no asthma and asthma normal spirometry groups (0.19±0.12; 0.23±0.13 kPa/(L·s-1), p<0.05) but to a lesser degree than the asthma obstructed spirometry group (0.34±0.20 kPa/(L·s-1), p<0.05). Differences between groups persisted post-bronchodilator (p<0.05). Following voluntary inflation to predicted FRC, R5-20 in the no asthma and asthma normal spirometry groups fell to similar values, indicating a reversible process (0.11±0.07; 0.12±0.08 kPa/(L·s-1), p=NS). Persistently elevated R5-20 was seen in the asthma obstructed spirometry group, suggesting chronic inflammation and/or remodelling (0.17±0.11 kPa/(L·s-1), p<0.05). Thus, small airway abnormalities of greater magnitude than observations in healthy obese people may be an early marker of asthma in obese subjects with self-reported disease despite normal airflow. Increased metabolic comorbidities in these subjects may have provided a milieu that impacted airway function.
PMCID:7369433
PMID: 32714957
ISSN: 2312-0541
CID: 4540052

Technical Standards for Respiratory Oscillometry

King, Gregory G; Bates, Jason; Berger, Kenneth I; Calverley, Peter; de Melo, Pedro L; Dellacà, Raffaele L; Farré, Ramon; Hall, Graham L; Ioan, Iulia; Irvin, Charles G; Kaczka, David W; Kaminsky, David A; Kurosawa, Hajime; Lombardi, Enrico; Maksym, Geoffrey N; Marchal, François; Oppenheimer, Beno W; Simpson, Shannon J; Thamrin, Cindy; van den Berge, Maarten; Oostveen, Ellie
PMID: 31772002
ISSN: 1399-3003
CID: 4215932