Searched for: in-biosketch:true
person:chungc07
Superior hypophyseal arteries: angiographic re-discovery, comprehensive assessment, and embryologic implications
Shapiro, Maksim; Sharashidze, Vera; Nossek, Erez; Sen, Chandra; Rutledge, Caleb; Chung, Charlotte; Khawaja, Ayaz; Kvint, Svetlana; Riina, Howard; Nelson, Peter Kim; Raz, Eytan
UNLABELLED:The superior hypophyseal arteries (SHAs) are well known in anatomical and surgical literature, with a well-established role in supply of the anterior hypophysis and superjacent optic apparatus. However, due to small size and overlap with other vessels, in vivo imaging by any modality has been essentially non-existent. Advances in high resolution cone beam CT angiography (CBCTA) now enables this deficiency to be addressed. This paper presents, to the best of our knowledge, the first comprehensive in vivo imaging evaluation of the SHAs. METHODS:Twenty-five CBCTA studies of common or internal carotid arteries were obtained for a variety of clinical reasons. Dedicated secondary reconstructions of the siphon were performed, recording the presence, number, and supply territory of SHAs. A spectrum approach, emphasizing balance with adjacent territories (inferior hypophyseal, ophthalmic, posterior and communicating region arteries) was investigated. RESULTS:The SHAs were present in all cases. Supply of the anterior pituitary was nearly universal (96%) and almost half (44%) originated from the 'cave' region, in excellent agreement with surgical literature. Optic apparatus supply was more difficult to adjudicate, but appeared present in most cases. The relationship with superior hypophyseal aneurysms was consistent. Patency following flow diverter placement was typical, despite a presumably rich collateral network. Embryologic implications with respect to the ophthalmic artery and infraoptic course of the anterior cerebral artery are intriguing. CONCLUSIONS:SHAs are consistently seen with CBCTA, allowing for correlation with existing anatomical and surgical literature, laying the groundwork for future in vivo investigation.
PMID: 37875341
ISSN: 1759-8486
CID: 5614322
The impact of postoperative aspirin in patients undergoing Woven EndoBridge: a multicenter, institutional, propensity score-matched analysis
Dmytriw, Adam A; Musmar, Basel; Salim, Hamza; Aslan, Assala; Cancelliere, Nicole M; McLellan, Rachel M; Algin, Oktay; Ghozy, Sherief; Dibas, Mahmoud; Lay, Sovann V; Guenego, Adrien; Renieri, Leonardo; Carnevale, Joseph Anthony; Saliou, Guillaume; Mastorakos, Panagiotis; El Naamani, Kareem; Shotar, Eimad; Premat, Kevin; Möhlenbruch, Markus A; Kral, Michael; Doron, Omer; Chung, Charlotte; Salem, Mohamed M; Lylyk, Ivan; Foreman, Paul M; Vachhani, Jay A; Shaikh, Hamza; ŽupanÄić, Vedran; Hafeez, Muhammad Ubaid; Catapano, Joshua S; Waqas, Muhammad; Tutino, Vincent M; Ibrahim, Mohamed K; Mohammed, Marwa A; Imamoglu, Cetin; Bayrak, Ahmet; Rabinov, James D; Ren, Yifan; Schirmer, Clemens M; Piano, Mariangela; Kuhn, Anna Luisa; Michelozzi, Caterina; Elens, Stephanie; Hasan, Zuha; Starke, Robert M; Hassan, Ameer E; Ogilvie, Mark; Nguyen, Anh; Jones, Jesse; Brinjikji, Waleed; Nawka, Marie Teresa; Psychogios, Marios-Nikos; Ulfert, Christian; Diestro, Jose Danilo Bengzon; Pukenas, Bryan; Burkhardt, Jan Karl; Huynh, Thien J; Martinez-Gutierrez, Juan Carlos; Essibayi, Muhammed Amir; Sheth, Sunil A; Spiegel, Gary; Tawk, Rabih; Lubicz, Boris; Panni, Pietro; Puri, Ajit S; Pero, Guglielmo; Nossek, Erez; Raz, Eytan; Killer-Oberpfalzer, Monika; Griessenauer, Christoph J; Asadi, Hamed; Siddiqui, Adnan H; Brook, Allan L; Altschul, David; Ducruet, Andrew F; Albuquerque, Felipe C; Regenhardt, Robert W; Stapleton, Christopher J; Kan, Peter; Kalousek, Vladimir; Lylyk, Pedro; Boddu, Srikanth Reddy; Knopman, Jared; Aziz-Sultan, Mohammad A; Tjoumakaris, Stavropoula I; Clarençon, Frédéric; Limbucci, Nicola; Cuellar, Hugo H; Jabbour, Pascal M; Pereira, Vitor M; Patel, Aman B; Adeeb, Nimer
BACKGROUND:The Woven EndoBridge (WEB) device is frequently used for the treatment of intracranial aneurysms. Postoperative management, including the use of aspirin, varies among clinicians and institutions, but its impact on the outcomes of the WEB has not been thoroughly investigated. METHODS:This was a retrospective, multicenter study involving 30 academic institutions in North America, South America, and Europe. Data from 1492 patients treated with the WEB device were included. Patients were categorized into two groups based on their postoperative use of aspirin (aspirin group: n=1124, non-aspirin group: n=368). Data points included patient demographics, aneurysm characteristics, procedural details, complications, and angiographic and functional outcomes. Propensity score matching (PSM) was applied to balance variables between the two groups. RESULTS:Prior to PSM, the aspirin group exhibited significantly higher rates of modified Rankin scale (mRS) mRS 0-1 and mRS 0-2 (89.8% vs 73.4% and 94.1% vs 79.8%, p<0.001), lower rates of mortality (1.6% vs 8.6%, p<0.001), and higher major compaction rates (13.4% vs 7%, p<0.001). Post-PSM, the aspirin group showed significantly higher rates of retreatment (p=0.026) and major compaction (p=0.037) while maintaining its higher rates of good functional outcomes and lower mortality rates. In the multivariable regression, aspirin was associated with higher rates of mRS 0-1 (OR 2.166; 95% CI 1.16 to 4, p=0.016) and mRS 0-2 (OR 2.817; 95% CI 1.36 to 5.88, p=0.005) and lower rates of mortality (OR 0.228; 95% CI 0.06 to 0.83, p=0.025). However, it was associated with higher rates of retreatment (OR 2.471; 95% CI 1.11 to 5.51, p=0.027). CONCLUSIONS:Aspirin use post-WEB treatment may lead to better functional outcomes and lower mortality but with higher retreatment rates. These insights are crucial for postoperative management after WEB procedures, but further studies are necessary for validation.
PMID: 38238006
ISSN: 1759-8486
CID: 5699752
Interrupted Versus Running Sutures for Superficial Temporal Artery to Middle Cerebral Artery Cranial Bypass
Grin, Eric A; Wiggan, Daniel D; Sangwon, Karl L; Baranoski, Jacob; Sharashidze, Vera; Shapiro, Maksim; Raz, Eytan; Chung, Charlotte; Nelson, Peter Kim; Riina, Howard A; Rutledge, Caleb; Nossek, Erez
BACKGROUND AND OBJECTIVES/OBJECTIVE:Superficial temporal artery to middle cerebral artery (STA-MCA) bypass is the workhorse for flow augmentation surgery. Although either interrupted or running sutures can be used to complete the anastomosis with high intraoperative patency rates, no previous study in the cranial bypass literature has compared long-term patency and maturity of end-to-side STA-MCA anastomoses. We compared STA-MCA anastomoses performed with running vs interrupted sutures by evaluating bypass flow and anastomotic maturation on follow-up vascular imaging. METHODS:Ninety-six STA-MCA anastomoses were performed from 1/2019 to 6/2024. Forty-seven anastomoses (40 patients) with long-term vascular imaging were retrospectively analyzed. All anastomoses were intraoperatively patent on initial revascularization. Patient demographics, clinical course, and imaging were reviewed. All images were reviewed by a neuroradiologist or a cerebrovascular neurosurgeon. RESULTS:Twenty-five anastomoses were performed with interrupted sutures and compared with 22 anastomoses performed with running sutures. All patients underwent a preoperative perfusion assessment confirming a significant hypoperfusion state. There were no significant differences between cohorts in demographics, bypass indication, or time to follow-up. Formal digital subtraction angiography was performed for 35 anastomoses (21 interrupted, 14 running). On digital subtraction angiography follow-up, there was no difference in STA caliber between cohorts (P = .204), but there was a difference in anastomotic growth (P = .014), with 5/21 (23.8%) anastomoses stable or enlarged in the interrupted cohort vs 9/14 (64.3%) stable or enlarged in the running cohort. Notably, of the 47 total anastomoses, there was no difference in long-term bypass patency between interrupted and running anastomoses (22/25 (88.0%) vs 22/22 (100.0%), respectively, P = .380). CONCLUSION/CONCLUSIONS:No significant differences in patency or STA caliber on follow-up imaging were observed between STA-MCA anastomoses performed with interrupted vs running sutures although a difference in anastomotic maturity was observed, with the running suture cohort having a higher proportion of enlarged or stable anastomoses. Further studies are needed for validation.
PMID: 39641541
ISSN: 2332-4260
CID: 5780202
Transvenous embolization with detachable coils for a hypoglossal canal dural arteriovenous fistula: illustrative case
Hagstrom, Rory; Raz, Eytan; Chung, Charlotte; Save, Akshay V; Khawaja, Ayaz M; Ponchione, Elizabeth; Frome, Spencer; Sharashidze, Vera; Baranoski, Jacob; Rutledge, Caleb W; Nossek, Erez; Shapiro, Maksim; Nelson, Peter K; Riina, Howard A
BACKGROUND:Hypoglossal canal dural arteriovenous fistulas (HCDAVFs) are a relatively rare subtype of dural arteriovenous fistula (dAVF), representing 3%-5% of all dAVFs. The complex angio- and venous architecture predisposed to numerous anastomoses and nearby anatomical structures, including the posterior fossa sinuses and cranial nerves, can complicate both the diagnosis and treatment of these lesions. OBSERVATIONS/METHODS:The authors describe the case of HCDAVF in a 74-year-old male who presented with pulsatile tinnitus (PT) lasting 3 months and significant fatigue, headaches, and dizziness. Diagnostic cerebral angiography demonstrated a left-sided HCDAVF with bilateral supply from the ascending pharyngeal arteries and fistulous connection at the level of the left anterior condylar vein (ACV). This lesion was consistent with a Cognard and Borden type I dAVF. LESSONS/CONCLUSIONS:The authors present a case in which transvenous embolization (TVE) with detachable coils via the ipsilateral internal jugular vein successfully occluded the previously visualized shunt to the left ACV and provided a clinical cure for the patient's PT and headaches without complication. Selecting the appropriate treatment strategy for the successful treatment of HCDAVFs is predicated on a comprehensive understanding of the anatomical features of the lesion, namely arterial feeders, venous drainage pattern, and location of the fistulous connection. TVE is a safe and efficacious treatment option for HCDAVFs. https://thejns.org/doi/10.3171/CASE24606.
PMCID:11579907
PMID: 39556806
ISSN: 2694-1902
CID: 5758172
Defining ideal middle cerebral artery bifurcation aneurysm size for Woven EndoBridge embolization
Adeeb, Nimer; Musmar, Basel; Salim, Hamza Adel; Aslan, Assala; Alla, Anika; Cancelliere, Nicole M; McLellan, Rachel M; Algin, Oktay; Ghozy, Sherief; Dibas, Mahmoud; Lay, Sovann V; Guenego, Adrien; Renieri, Leonardo; Carnevale, Joseph; Saliou, Guillaume; Mastorakos, Panagiotis; Naamani, Kareem El; Shotar, Eimad; Premat, Kevin; Möhlenbruch, Markus; Kral, Michael; Doron, Omer; Chung, Charlotte; Salem, Mohamed M; Lylyk, Ivan; Foreman, Paul M; Vachhani, Jay A; Shaikh, Hamza; ŽupanÄić, Vedran; Hafeez, Muhammad U; Catapano, Joshua S; Waqas, Muhammad; Tutino, Vincent M; Ibrahim, Mohamed K; Mohammed, Marwa A; Ozates, M Ozgur; Ayberk, Giyas; Rabinov, James D; Ren, Yifan; Schirmer, Clemens M; Piano, Mariangela; Kühn, Anna L; Michelozzi, Caterina; Elens, Stéphanie; Starke, Robert M; Hassan, Ameer; Ogilvie, Mark; Nguyen, Anh; Jones, Jesse; Brinjikji, Waleed; Nawka, Marie T; Psychogios, Marios; Ulfert, Christian; Diestro, Jose Danilo Bengzon; Pukenas, Bryan; Burkhardt, Jan-Karl; Domingo, Ricardo A; Huynh, Thien; Martinez-Gutierrez, Juan Carlos; Essibayi, Muhammed Amir; Sheth, Sunil A; Spiegel, Gary; Tawk, Rabih G; Lubicz, Boris; Panni, Pietro; Puri, Ajit S; Pero, Guglielmo; Nossek, Erez; Raz, Eytan; Killer-Oberfalzer, Monika; Griessenauer, Christoph J; Asadi, Hamed; Siddiqui, Adnan; Brook, Allan L; Altschul, David; Ducruet, Andrew F; Albuquerque, Felipe C; Regenhardt, Robert W; Stapleton, Christopher J; Kan, Peter; Kalousek, Vladimir; Lylyk, Pedro; Boddu, Srikanth; Knopman, Jared; Aziz-Sultan, Mohammad A; Tjoumakaris, Stavropoula I; Clarençon, Frédéric; Limbucci, Nicola; Cuellar-Saenz, Hugo H; Jabbour, Pascal M; Mendes Pereira, Vitor; Patel, Aman B; Dmytriw, Adam A
OBJECTIVE:The Woven EndoBridge (WEB) device was approved to treat wide-necked bifurcation aneurysms. The device is designed as an intrasaccular flow disruptor covering aneurysm widths up to 10 mm. Although prior studies combined all aneurysm sizes, it is known that aneurysms behave differently in response to endovascular treatment based on their size. Therefore, the authors' objective was to identify ideal middle cerebral artery (MCA) aneurysm width and neck sizes most suitable for WEB treatment. METHODS:The WorldWideWEB consortium is a large multicenter retrospective database that analyzes intracranial aneurysms treated with the WEB device. In this study, all unruptured MCA bifurcation aneurysms with available measurements were included. Cutoff values based on aneurysm width and neck in relation to aneurysm occlusion status were measured using the receiver operating characteristic (ROC) curve. Propensity score matching (PSM) was then used to compare treatment outcomes between aneurysms smaller and larger than the cutoff value for both width and neck size. RESULTS:The ideal cutoff values for MCA bifurcation aneurysm width and neck were 6.1 mm and 4.6 mm, respectively. On PSM, 87 matched pairs were compared based on width size (≤ 6.1 mm and > 6.1 mm), and 77 matched pairs were compared based on neck size (≤ 4.6 mm and > 4.6 mm). There was a significant difference in adequate aneurysm occlusion between aneurysms smaller and larger than those cutoff values for both widths (93% vs 76%, p = 0.0017) and neck sizes (90% vs 70%, p = 0.0026). The retreatment rate was also significantly higher for larger aneurysms in both parameters. CONCLUSIONS:This study shows that MCA bifurcation aneurysms ≤ 6.1 mm in width and ≤ 4.6 mm in neck size are significantly better candidates for WEB treatment, leading to improved occlusion status and reduced retreatment rate, which are important considerations when using WEB devices.
PMID: 39393093
ISSN: 1933-0693
CID: 5706322
Association of preprocedural antiplatelet use with decreased thromboembolic complications for intracranial aneurysms undergoing intrasaccular flow disruption
Diestro, Jose Danilo Bengzon; Adeeb, Nimer; Musmar, Basel; Salim, Hamza; Aslan, Assala; Cancelliere, Nicole M; McLellan, Rachel M; Algin, Oktay; Ghozy, Sherief; Lay, Sovann V; Guenego, Adrien; Renieri, Leonardo; Carnevale, Joseph; Saliou, Guillaume; Mastorakos, Panagiotis; El Naamani, Kareem; Shotar, Eimad; Premat, Kevin; Möhlenbruch, Markus; Kral, Michael; Bernstock, Joshua D; Doron, Omer; Chung, Charlotte; Salem, Mohamed M; Lylyk, Ivan; Foreman, Paul M; Vachhani, Jay A; Shaikh, Hamza; ŽupanÄić, Vedran; Hafeez, Muhammad U; Catapano, Joshua; Waqas, Muhammad; Ibrahim, Mohamed K; Mohammed, Marwa A; Imamoglu, Cetin; Bayrak, Ahmet; Rabinov, James D; Ren, Yifan; Schirmer, Clemens M; Piano, Mariangela; Kühn, Anna L; Michelozzi, Caterina; Elens, Stéphanie; Starke, Robert M; Hassan, Ameer E; Ogilvie, Mark; Nguyen, Anh; Jones, Jesse; Brinjikji, Waleed; Nawka, Marie T; Psychogios, Marios; Ulfert, Christian; Pukenas, Bryan; Burkhardt, Jan-Karl; Huynh, Thien; Martinez-Gutierrez, Juan Carlos; Essibayi, Muhammed Amir; Sheth, Sunil A; Spiegel, Gary; Tawk, Rabih G; Lubicz, Boris; Panni, Pietro; Puri, Ajit S; Pero, Guglielmo; Nossek, Erez; Raz, Eytan; Killer-Oberpfalzer, Monika; Griessenauer, Christoph J; Asadi, Hamed; Siddiqui, Adnan; Brook, Allan L; Altschul, David; Spears, Julian; Marotta, Thomas R; Ducruet, Andrew F; Albuquerque, Felipe C; Regenhardt, Robert W; Stapleton, Christopher J; Kan, Peter; Kalousek, Vladimir; Lylyk, Pedro; Boddu, Srikanth; Knopman, Jared; Aziz-Sultan, Mohammad A; Tjoumakaris, Stavropoula I; Jabbour, Pascal M; Clarençon, Frédéric; Limbucci, Nicola; Cuellar-Saenz, Hugo H; Mendes Pereira, Vitor; Patel, Aman B; Dmytriw, Adam A
OBJECTIVE:This study was conducted to investigate the impact of antiplatelet administration in the periprocedural period on the occurrence of thromboembolic complications (TECs) in patients undergoing treatment using the Woven EndoBridge (WEB) device for intracranial wide-necked bifurcation aneurysms. The primary objective was to assess whether the use of antiplatelets in the pre- and postprocedural phases reduces the likelihood of developing TECs, considering various covariates. METHODS:A retrospective multicenter observational study was conducted within the WorldWideWEB Consortium and comprised 38 academic centers with endovascular treatment capabilities. Univariable and multivariable logistic regression analyses were performed to determine the association between antiplatelet use and TECs, adjusting for covariates. Missing predictor data were addressed using multiple imputation. RESULTS:The study comprised two cohorts: one addressing general thromboembolic events and consisting of 1412 patients, among whom 103 experienced TECs, and another focusing on symptomatic thromboembolic events and comprising 1395 patients, of whom 50 experienced symptomatic TECs. Preprocedural antiplatelet use was associated with a reduced likelihood of overall TECs (OR 0.32, 95% CI 0.19-0.53, p < 0.001) and symptomatic TECs (OR 0.49, 95% CI 0.25-0.95, p = 0.036), whereas postprocedural antiplatelet use showed no significant association with TECs. The study also revealed additional predictors of TECs, including stent use (overall: OR 4.96, 95% CI 2.38-10.3, p < 0.001; symptomatic: OR 3.24, 95% CI 1.26-8.36, p = 0.015), WEB single-layer sphere (SLS) type (overall: OR 0.18, 95% CI 0.04-0.74, p = 0.017), and posterior circulation aneurysm location (symptomatic: OR 18.43, 95% CI 1.48-230, p = 0.024). CONCLUSIONS:The findings of this study suggest that the preprocedural administration of antiplatelets is associated with a reduced likelihood of TECs in patients undergoing treatment with the WEB device for wide-necked bifurcation aneurysms. However, postprocedural antiplatelet use did not show a significant impact on TEC occurrence.
PMID: 38701528
ISSN: 1933-0693
CID: 5713872
Pipeline embolization device as a standalone curative approach for recurrent sigmoid sinus DAVF
Sharashidze, Vera; Chung, Charlotte; Nelson, Peter Kim; Shapiro, Maksim; Riina, Howard; Nossek, Erez; Raz, Eytan
Dural arteriovenous fistulas (dAVFs) can occur as complications after surgical procedures, especially following the resection of meningiomas near the dural sinus. This case report presents a 74-year-old male who developed a recurrent sigmoid dAVF following meningioma resection. Initially treated with transvenous embolization and middle meningeal artery embolization, the dAVF recurred with worsening clinical symptoms. Conventional treatment options, including sinus sacrifice and transarterial embolization, were unsuitable due to the critical role of the patient's dominant right sigmoid sinus in cerebral venous drainage. Consequently, a reconstructive approach was employed using a pipeline embolization device (PED) construct. The PED successfully occluded the dAVF while preserving the function of the sigmoid sinus. A follow-up angiogram confirmed stable occlusion and normalization of intracranial venous drainage. This case underscores the potential of flow diversion as a viable treatment option for dAVFs, particularly in scenarios where preserving venous sinus function is paramount.
PMCID:11559946
PMID: 39311021
ISSN: 2385-2011
CID: 5802842
Vascular Pathologic Conditions in and around the Spinal Cord
McCarty, Jennifer; Chung, Charlotte; Samant, Rohan; Sitton, Clark; Bonfante, Eliana; Chen, Peng Roc; Raz, Eytan; Shapiro, Maksim; Riascos, Roy; Gavito-Higuera, Jose
Diagnosing and differentiating spinal vascular pathologic conditions is challenging. Small structures, lengthy imaging examinations, and overlapping imaging features increase the difficulty. Yet, subtle findings and helpful protocols can narrow the differential diagnosis. The authors aim to help radiologists make accurate and timely diagnoses of spinal vascular pathologic conditions in and around the spinal cord by highlighting spinal vascular anatomy, imaging findings, and three broad categories of abnormalities: infarcts, anomalies, and tumors. ©RSNA, 2024.
PMID: 39207926
ISSN: 1527-1323
CID: 5701982
Mechanical disorders of the cervicocerebral circulation in children and young adults
Baranoski, Jacob F; White, Andrew C; Chung, Charlotte Y; Catapano, Joshua S; De Oliveira Sillero, Rafael; Hui, Ferdinand K; Huisman, Thierry Agm; Lawton, Michael T; Abruzzo, Todd
Mechanical disorders of the cervicocerebral circulation (MDCC) are conditions in which neurological symptoms result from a disturbance of cerebral blood flow attributable to external mechanical forces exerted on extracranial blood vessels by adjacent musculoskeletal structures during head movement that is presumably within a physiological range. The disease spectrum includes bow hunter's syndrome, carotid-type Eagle syndrome, and various dynamic venous compression syndromes. These conditions have distinct phenotypes in children which differ from those expressed in older adults. In contemporary practice, recognition and diagnostic evaluation is the domain of the neuroendovascular specialist. The diagnostic evaluation of MDCC involves significant technical nuance that can be critical to directing appropriate management, particularly in children. This report aims to provide a comprehensive overview of the pathophysiology, anatomical patterns, diagnosis, and treatment for the full spectrum of MDCC that is commonly encountered in clinical practice.
PMID: 37696598
ISSN: 1759-8486
CID: 5593822
Creation of a predictive calculator to determine adequacy of occlusion of the woven endobridge (WEB) device in intracranial aneurysms-A retrospective analysis of the WorldWide WEB Consortium database
Musmar, Basel; Adeeb, Nimer; Gendreau, Julian; Horowitz, Melanie Alfonzo; Salim, Hamza Adel; Sanmugananthan, Praveen; Aslan, Assala; Brown, Nolan J; Cancelliere, Nicole M; McLellan, Rachel M; Algin, Oktay; Ghozy, Sherief; Dibas, Mahmoud; Orscelik, Atakan; Senol, Yigit Can; Lay, Sovann V; Guenego, Adrien; Renieri, Leonardo; Carnevale, Joseph; Saliou, Guillaume; Mastorakos, Panagiotis; El Naamani, Kareem; Shotar, Eimad; Premat, Kevin; Möhlenbruch, Markus; Kral, Michael; Doron, Omer; Chung, Charlotte; Salem, Mohamed M; Lylyk, Ivan; Foreman, Paul M; Vachhani, Jay A; Shaikh, Hamza; ŽupanÄić, Vedran; Hafeez, Muhammad U; Catapano, Joshua; Waqas, Muhammad; Tutino, Vincent M; Gokhan, Yuce; Imamoglu, Cetin; Bayrak, Ahmet; Rabinov, James D; Ren, Yifan; Schirmer, Clemens M; Piano, Mariangela; Kühn, Anna L; Michelozzi, Caterina; Elens, Stéphanie; Starke, Robert M; Hassan, Ameer E; Ogilvie, Mark; Nguyen, Anh; Jones, Jesse; Brinjikji, Waleed; Nawka, Marie T; Psychogios, Marios; Ulfert, Christian; Bengzon Diestro, Jose Danilo; Pukenas, Bryan; Burkhardt, Jan-Karl; Huynh, Thien; Martinez-Gutierrez, Juan Carlos; Essibayi, Muhammed Amir; Sheth, Sunil A; Spiegel, Gary; Tawk, Rabih; Lubicz, Boris; Panni, Pietro; Puri, Ajit S; Pero, Guglielmo; Nossek, Erez; Raz, Eytan; Killer-Oberfalzer, Monika; Griessenauer, Christoph J; Asadi, Hamed; Siddiqui, Adnan; Brook, Allan L; Altschul, David; Ducruet, Andrew F; Albuquerque, Felipe C; Regenhardt, Robert W; Stapleton, Christopher J; Kan, Peter; Kalousek, Vladimir; Lylyk, Pedro; Boddu, Srikanth; Knopman, Jared; Aziz-Sultan, Mohammad A; Tjoumakaris, Stavropoula I; Clarençon, Frédéric; Limbucci, Nicola; Bydon, Mohamad; Hasan, David; Cuellar-Saenz, Hugo H; Jabbour, Pascal M; Pereira, Vitor Mendes; Patel, Aman B; Dmytriw, Adam A
BACKGROUND:Endovascular treatment with the woven endobridge (WEB) device has been widely utilized for managing intracranial aneurysms. However, predicting the probability of achieving adequate occlusion (Raymond-Roy classification 1 or 2) remains challenging. OBJECTIVE:Our study sought to develop and validate a predictive calculator for adequate occlusion using the WEB device via data from a large multi-institutional retrospective cohort. METHODS:We used data from the WorldWide WEB Consortium, encompassing 356 patients from 30 centers across North America, South America, and Europe. Bivariate and multivariate regression analyses were performed on a variety of demographic and clinical factors, from which predictive factors were selected. Calibration and validation were conducted, with variance inflation factor (VIF) parameters checked for collinearity. RESULTS:-value of 0.431. The calculator is available at: https://neurodx.shinyapps.io/WEBDEVICE/. CONCLUSION/CONCLUSIONS:The predictive calculator offers a substantial contribution to the clinical toolkit for estimating the likelihood of adequate intracranial aneurysm occlusion by WEB device embolization.
PMID: 39127463
ISSN: 2385-2011
CID: 5731052