Try a new search

Format these results:

Searched for:

in-biosketch:true

person:shapiw01

Total Results:

62


The value of intraoperative EABRs in auditory brainstem implantation

Anwar, Abbas; Singleton, Alison; Fang, Yixin; Wang, Binhuan; Shapiro, William; Roland, J Thomas Jr; Waltzman, Susan B
OBJECTIVE: To compare the intraoperative electrically evoked auditory brainstem response (EABR) morphologies between neurofibromatosis II (NF2) adult auditory brainstem implant (ABI) recipients who had auditory percepts post-operatively and those who did not and between NF2 adult ABI recipients and non-NF2 pediatric ABI recipients. METHODS: This was a retrospective case series at a single tertiary academic referral center examining all ABI recipients from 1994 to 2016, which included 34 NF2 adults and 11 non-NF2 children. The morphologies of intraoperative EABRs were evaluated for the number of waveforms showing a response, the number of positive peaks in those responses, and the latencies of each of these peaks. RESULTS: 27/34 adult NF2 patients and 9/10 children had EABR waveforms. 20/27 (74.0%) of the adult patients and all of the children had ABI devices that stimulated post-operatively. When comparing the waveforms between adults who stimulated and those who did not stimulate, the proportion of total number of intraoperative EABR peaks to total possible peaks was significantly higher for the adults who stimulated than for those who did not (p < 0.05). Children had a significantly higher proportion of total number of peaks to total possible peaks when compared to adults who stimulated (p < 0.02). Additionally, there were more likely to be EABR responses at the initial stimulation than intraoperatively in the pediatric ABI population (p = 0.065). CONCLUSIONS: The value of intraoperative EABR tracing may lie in its ability to predict post-operative auditory percepts based on the placement of the array providing the highest number of total peaks.
PMID: 28964288
ISSN: 1872-8464
CID: 2719782

Self-Reported Usage, Functional Benefit, and Audiologic Characteristics of Cochlear Implant Patients Who Use a Contralateral Hearing Aid

Neuman, Arlene C; Waltzman, Susan B; Shapiro, William H; Neukam, Jonathan D; Zeman, Annette M; Svirsky, Mario A
Ninety-four unilateral CI patients with bimodal listening experience (CI plus HA in contralateral ear) completed a questionnaire that focused on attitudes toward hearing aid use postimplantation, patterns of usage, and perceived bimodal benefits in daily life. Eighty participants continued HA use and 14 discontinued HA use at the time of the questionnaire. Participant responses provided useful information for counseling patients both before and after implantation. The majority of continuing bimodal (CI plus HA) participants reported adapting to using both devices within 3 months and also reported that they heard better bimodally in quiet, noisy, and reverberant conditions. They also perceived benefits including improved sound quality, better music enjoyment, and sometimes a perceived sense of acoustic balance. Those who discontinued HA use found either that using the HA did not provide additional benefit over the CI alone or that using the HA degraded the signal from the CI. Because there was considerable overlap in the audiograms and in speech recognition performance in the unimplanted ear between the two groups, we recommend that unilateral CI recipients are counseled to continue to use the HA in the contralateral ear postimplantation in order to determine whether or not they receive functional or perceived benefit from using both devices together.
PMCID:5435367
PMID: 28351216
ISSN: 2331-2165
CID: 2508302

Single-sided Deafness Cochlear Implantation: Candidacy, Evaluation, and Outcomes in Children and Adults

Friedmann, David R; Ahmed, Omar H; McMenomey, Sean O; Shapiro, William H; Waltzman, Susan B; Roland, J Thomas Jr
OBJECTIVES: Although there are various available treatment options for unilateral severe-to-profound hearing loss, these options do not provide the benefits of binaural hearing since sound is directed from the poorer ear to the better ear. The purpose of this investigation was to review our center's experience with cochlear implantation in such patients in providing improved auditory benefits and useful binaural hearing. STUDY DESIGN: Retrospective chart review. METHODS: Twelve adult patients and four pediatric patients with unilateral severe-to-profound hearing loss received an implant in the poorer ear. Outcome measures performed preoperatively on each ear and binaurally included consonant-nucleus-consonant (CNC) monosyllabic words and sentences in noise. The mean pure-tune average in the better ear was within normal range. RESULTS: Test scores revealed a significant improvement in CNC and sentence in noise test scores from the preoperative to most recent postoperative evaluation in the isolated implant ear. All adult subjects use the device full-time. CONCLUSIONS: The data reveal significant improvement in speech perception performance in quiet and in noise in patients with single-sided deafness after implantation. Performance might depend on factors including length of hearing loss, age at implantation, and device usage.
PMID: 26756150
ISSN: 1537-4505
CID: 1911352

Cochlear implant programming: a global survey on the state of the art

Vaerenberg, Bart; Smits, Cas; De Ceulaer, Geert; Zir, Elie; Harman, Sally; Jaspers, N; Tam, Y; Dillon, Margaret; Wesarg, Thomas; Martin-Bonniot, D; Gartner, L; Cozma, Sebastian; Kosaner, Julie; Prentiss, Sandra; Sasidharan, P; Briaire, Jeroen J; Bradley, Jane; Debruyne, J; Hollow, R; Patadia, Rajesh; Mens, Lucas; Veekmans, K; Greisiger, R; Harboun-Cohen, E; Borel, Stephanie; Tavora-Vieira, Dayse; Mancini, Patrizia; Cullington, Helen; Ng, Amy Han-Chi; Walkowiak, Adam; Shapiro, William H; Govaerts, Paul J
The programming of CIs is essential for good performance. However, no Good Clinical Practice guidelines exist. This paper reports on the results of an inventory of the current practice worldwide. A questionnaire was distributed to 47 CI centers. They follow 47600 recipients in 17 countries and 5 continents. The results were discussed during a debate. Sixty-two percent of the results were verified through individual interviews during the following months. Most centers (72%) participated in a cross-sectional study logging 5 consecutive fitting sessions in 5 different recipients. Data indicate that general practice starts with a single switch-on session, followed by three monthly sessions, three quarterly sessions, and then annual sessions, all containing one hour of programming and testing. The main focus lies on setting maximum and, to a lesser extent, minimum current levels per electrode. These levels are often determined on a few electrodes and then extrapolated. They are mainly based on subjective loudness perception by the CI user and, to a lesser extent, on pure tone and speech audiometry. Objective measures play a small role as indication of the global MAP profile. Other MAP parameters are rarely modified. Measurable targets are only defined for pure tone audiometry. Huge variation exists between centers on all aspects of the fitting practice.
PMCID:3932199
PMID: 24688394
ISSN: 1537-744x
CID: 867292

The Effects of Residual Hearing in Traditional Cochlear Implant Candidates After Implantation With a Conventional Electrode

Cosetti, Maura K; Friedmann, David R; Zhu, Bovey Z; Heman-Ackah, Selena E; Fang, Yixin; Keller, Robert G; Shapiro, William H; Roland, J Thomas Jr; Waltzman, Susan B
OBJECTIVE: To analyze the effects of residual hearing on postoperative speech performance in traditional cochlear implant (CI) patients implanted with a conventional electrode. STUDY DESIGN: Retrospective review. SETTING: Academic tertiary referral center. PATIENTS: A total of 129 adults implanted by a single surgeon at a tertiary care facility between June 2005 and November 2010 with measurable preoperative pure tone thresholds at any frequency were included. INTERVENTION: Cochlear implantation with a conventional electrode via an anterior inferior cochleostomy. MAIN OUTCOME MEASURE: Speech perception using monosyllabic word scores in quiet and sentences in quiet and noise in the electric (CI-only) condition of the implanted ear. Preservation of hearing was defined as complete for postoperative thresholds within 10 dB of preimplant values and partial if greater than 11 dB. Pure tone audiometry and speech perception testing were performed preoperatively and at regular intervals postoperatively, with the 1-year evaluation being the final outcome period. RESULTS: Preservation at any frequency or level was not a factor in speech perception outcome, although preservation was more common in low frequencies. Hearing preservation was correlated with younger age at implantation, but was not related to length of hearing loss, cause of deafness, device type, sex, preoperative speech performance, or low-frequency pure-tone average. CONCLUSION: Hearing can be preserved in traditional CI patients implanted with a conventional electrode. Although preservation of hearing may have implications for future technology, it is not currently correlated with speech performance in the CI-only condition.
PMID: 23449440
ISSN: 1531-7129
CID: 232672

An evidence-based algorithm for intraoperative monitoring during cochlear implantation

Cosetti, Maura K; Troob, Scott H; Latzman, Jonathan M; Shapiro, William H; Roland, John Thomas Jr; Waltzman, Susan B
OBJECTIVE: To generate an evidence-based algorithm for the use of intraoperative testing during cochlear implantation (CI). STUDY DESIGN: Retrospective review. SETTING: Tertiary referral center. PATIENTS: A total of 277 children (aged 6 mo to 17 yr) and adults 18 years and older with normal cochlear anatomy who underwent primary and revision cochlear implantation at a single center between 2005 and 2010 were included. INTERVENTION: Intraoperative electrophysiologic monitoring and intraoperative Stenver's view plain film radiography. MAIN OUTCOME MEASURE: Intraoperative testing included the following: 1) individual electrode impedance measurements; 2) neural response telemetry (tNRT) levels for electrodes E20, E15, E10, and E5; and 3) plain film radiograph assessment of electrode position. RESULTS: No patient demonstrated abnormalities on all 3 modalities. Open or short electrodes on impedance testing were found in 6% of patients; half of these normalized when remeasured. Absent tNRT responses on 1 or more electrodes occurred in 14% of patients, although complete lack of response was rare (1.4%) and did not correlate with a dysfunctional device. Spread of excitation was performed in 1 patient and was consistent with a tip rollover. Intraoperative radiography identified tip-rollover and extracochlear electrode placement in all cases (n = 5, 1.8%) and prompted the use of the backup device. CONCLUSION: Immediate intraoperative determination of device functionality and optimal electrode placement is advantageous. Of the modalities tested, including electrode impedance, tNRT, and plain radiograph, only the radiographic results impacted intraoperative surgical decision making and led to the use of the backup device
PMID: 22222576
ISSN: 1537-4505
CID: 149959

Cochlear implant programming

Shapiro, William H; Bradham, Tamala S
Cochlear implants have become a viable treatment option for individuals who present with severe to profound hearing loss. While there are several parameters that affect the successful use of this technology, quality programming of the cochlear implant system is crucial. This review chapter focuses on general device programming techniques, programming techniques specific to children, objective programming techniques, a brief overview of programming parameters of the currently commercially available multichannel systems, and managing patient complaints and device failures. The chapter also provides what the authors believe the future may hold for new programming techniques
PMID: 22115685
ISSN: 1557-8259
CID: 141982

Auditory rehabilitation of patients with neurofibromatosis Type 2 by using cochlear implants

Roehm, Pamela C; Mallen-St Clair, Jon; Jethanamest, Daniel; Golfinos, John G; Shapiro, William; Waltzman, Susan; Roland, J Thomas Jr
OBJECT: The aim of this study was to determine whether patients with neurofibromatosis Type 2 (NF2) who have intact ipsilateral cochlear nerves can have open-set speech discrimination following cochlear implantation. METHODS: Records of 7 patients with documented NF2 were reviewed to determine speech discrimination outcomes following cochlear implantation. Outcomes were measured using consonant-nucleus-consonant words and phonemes; Hearing in Noise Test sentences in quiet; and City University of New York sentences in quiet and in noise. RESULTS: Preoperatively, none of the patients had open-set speech discrimination. Five of the 7 patients had previously undergone excision of ipsilateral vestibular schwannoma (VS). One of the patients who received a cochlear implant had received radiation therapy for ipsilateral VS, and another was undergoing observation for a small ipsilateral VS. Following cochlear implantation, 4 of 7 patients with NF2 had open-set speech discrimination following cochlear implantation during extended follow-up (15-120 months). Two of the 3 patients without open-set speech understanding had a prolonged period between ipsilateral VS resection and cochlear implantation (120 and 132 months), and had cochlear ossification at the time of implantation. The other patient without open-set speech understanding had good contralateral hearing at the time of cochlear implantation. Despite these findings, 6 of the 7 patients were daily users of their cochlear implants, and the seventh is an occasional user, indicating that all of the patients subjectively gained some benefit from their implants. CONCLUSIONS: Cochlear implantation can provide long-term auditory rehabilitation, with open-set speech discrimination for patients with NF2 who have intact ipsilateral cochlear nerves. Factors that can affect implant performance include the following: 1) a prolonged time between VS resection and implantation; and 2) cochlear ossification
PMCID:3590004
PMID: 21761973
ISSN: 1933-0693
CID: 141067

Intraoperative neural response telemetry as a predictor of performance

Cosetti, Maura K; Shapiro, William H; Green, Janet E; Roman, Benjamin R; Lalwani, Anil K; Gunn, Stacey H; Roland, John Thomas Jr; Waltzman, Susan B
OBJECTIVE:: To determine whether intraoperative neural response telemetry (tNRT) is predictive of postoperative speech perception. STUDY DESIGN:: Retrospective review. SETTING:: Tertiary referral center. PATIENTS:: Children (n = 24) aged between 5 and 17 years and adults 18 years and older (n = 73) with severe-to-profound hearing loss and implanted with the Nucleus Freedom device between 2005 and 2008 and observed at least 1 year were included. INTERVENTION:: Intraoperative neural response telemetry after insertion of the electrode array. MAIN OUTCOME MEASURE:: Measures included 1) intraoperative tNRT measurements and 2) preoperative and 1-year postoperative open-set word recognition scores using age-appropriate open-set tests for children and adults. Intraoperative neural response telemetry levels for electrodes E20, E15, E10, and E5 in each patient were correlated to performance at the 1-year evaluation interval. RESULTS:: No correlation existed between tNRT responses and open-set speech performance at the 1-year evaluation. Several patients had absent tNRT in the OR but developed speech recognition abilities, whereas the remaining patients had intraoperative responses with levels of postoperative performance ranging from 0% to 100%. CONCLUSION:: This study suggests that there is no significant correlation between intraoperative tNRT and speech perception performance at 1 year. At the time of surgery, tNRT provides valuable information regarding the electrical output of the implant and the response of the auditory system to electrical stimulation and preliminary device programming data; however, it is not a valuable predictor of postoperative performance. Furthermore, the absence of tNRT does not necessarily indicate a lack of stimulation
PMID: 20679959
ISSN: 1537-4505
CID: 111965

Speech perception and insertion trauma in hybrid cochlear implant users: A response to Gstottner and Arnolder [Letter]

Fitzgerald, MB; Sagi, E; Jackson, M; Shapiro, WH; Roland, JT; Waltzman, SB; Svirsky, MA
ISI:000259071900027
ISSN: 1531-7129
CID: 86665