Try a new search

Format these results:

Searched for:

in-biosketch:true

person:torroa01

Total Results:

77


Bone regeneration at extraction sockets filled with leukocyte-platelet-rich fibrin: An experimental pre-clinical study

Park, G; Jalkh, E-B; Boczar, D; Bergamo, E-T; Kim, H; Kurgansky, G; Torroni, A; Gil, L-F; Bonfante, E-A; Coelho, P-G; Witek, L
BACKGROUND:We aimed to histomorphometrically evaluate the effects of Leucocyte-Platelet-Rich Fibrin (L-PRF), with and without the combination of a bone grafting material, for alveolar ridge preservation using an in vivo canine model. MATERIAL AND METHODS/METHODS:Seven dogs (Female Beagles, ~18-month-old) were acquired for the study. L-PRF was prepared from each individual animal by drawing venous blood and spinning them through a centrifuge at 408 RCF-clot (IntrasSpin, Intra-Lock, Boca Raton, FL). L-PRF membranes were obtained from XPression fabrication kit (Biohorizons Implant Systems, Inc., AL, USA). A split mouth approach was adopted with the first molar mesial and distal socket defects treated in an interpolated fashion of the following study groups: 1) Empty socket (negative control); 2) OSS filled defect 3) L-PRF membrane; and 4) Mix of Bio-Oss® with L-PRF. After six weeks, samples were harvested, histologically processed, and evaluated for bone area fraction occupancy (BAFO), vertical/horizontal ridge dimensions (VRD and HRD, respectively), and area of coronal soft tissue infiltration. RESULTS:BAFO was statistically lower for the control group in comparison to all treatment groups. Defects treated with Bio-Oss® were not statistically different then defects treated solely with L-PRF. Collapsed across all groups, L-PRF exhibited higher degrees of BAFO than groups without L-PRF. Defects filled with Bio-Oss® and Bio-Oss® with L-PRF demonstrated greater maintenance of VRD relative to the control group. Collapsed across all groups, Bio-Oss® maintained the VRD and resulted in less area of coronal soft tissue infiltration compared to the empty defect. Soft tissue infiltration observed at the coronal area was not statistically different among defects filled with L-PRF, Bio-Oss®, and Bio-Oss® with L-PRF. CONCLUSIONS:Inclusion of L-PRF to particulate xenograft did not promote additional bone heading at 6 weeks in vivo. However, we noted that L-PRF alone promoted alveolar socket regeneration to levels comparable to particulate xenografts, suggesting its potential utilization for socket preservation.
PMCID:9445612
PMID: 35975804
ISSN: 1698-6946
CID: 5331412

Effect of leukocyte-platelet-rich fibrin in bone healing around dental implants placed in conventional and wide osteotomy sites: A pre-clinical study

Benalcázar Jalkh, Ernesto B; Tovar, Nick; Arbex, Leticia; Kurgansky, Gregory; Torroni, Andrea; Gil, Luiz F; Wall, Brittany; Kohanbash, Kimia; Bonfante, Estevam A; Coelho, Paulo G; Witek, Lukasz
Leukocyte-platelet-rich fibrin (L-PRF) has been suggested for gap management for immediate implant placement when the distance is greater than 2 mm. However, there remains a paucity in hierarchically designed research to support this application. The present study aimed to evaluate the effect of L-PRF on the osseointegration parameters of dental implants placed after conventional osteotomy of surgically created bone defects that simulate post extraction sockets in a canine model after 3, 6, and 12 weeks in vivo. Eighty dental implants (Intra-Lock, Boca Raton, FL) were placed in the radius of 13 beagle dogs. The experiment consisted of 4 groups (n = 20 implants/group): 1) Regular osteotomy (Reg n/L-PRF); 2) Regular osteotomy and implant placement with L-PRF membrane (Reg L-PRF); 3) Wide osteotomy with no gap management performed, where an osteotomy/bony defect (6 mm of diameter and ~5 mm deep) was created to simulate immediate implant placement in post-extraction sockets, and the gap was left for spontaneous healing (Wide nL-PRF); and 4) Wide osteotomy with L-PRF gap management (Wide L-PRF). L-PRF membranes were obtained by blood drawn from each subject and centrifuged at 2700 rpm (408 RCF-clot) for 12 min. In the experimental groups where L-PRF was utilized, the membrane was inserted into the osteotomy site prior to implant placement. Six dogs had implants placed in the radius for 3 weeks; and 7 dogs had implants placed in the left radius for 6 weeks and in the right radius for 12 weeks. At the corresponding experimental time points, samples were harvested, and subjected to histological processing for qualitative and quantitative analyses, via bone-to-implant contact (BIC) and bone-area-fraction occupancy (BAFO). Qualitative analysis demonstrated increased amounts of bone formation around the implant and within the healing chambers over time for all groups. While comparable histological features were observed for both Reg groups (L-PRF and nL-PRF), the gap management performed in Wide L-PRF group resulted in effective gap filling with improved bone growth in close proximity to the implant surface. Quantitative analyses of BIC and BAFO yielded higher values for both variables at 3 weeks for Wide L-PRF (~38% and ~56% respectively) compared to Wide nL-PRF (~20% for BIC and BAFO) (p < .03). No statistical differences were detected between Wide groups at 6 and 12 weeks, neither between Reg groups, independent of the association with or without the L-PRF membrane at all healing times. L-PRF placed within wide osteotomies, prior to implant placement, resulted in increased early bone formation compared to unfilled wide osteotomies at the early healing time (3 weeks in vivo).
PMID: 35771197
ISSN: 1552-4981
CID: 5281272

Transforming the Degradation Rate of β-tricalcium Phosphate Bone Replacement Using 3-Dimensional Printing

Shen, Chen; Wang, Maxime M; Witek, Lukasz; Tovar, Nick; Cronstein, Bruce N; Torroni, Andrea; Flores, Roberto L; Coelho, Paulo G
BACKGROUND:β-Tricalcium phosphate (β-TCP) is one of the most common synthetic bone grafting materials utilized in craniofacial reconstruction; however, it is limited by a slow degradation rate. The aim of this study was to leverage 3-dimensional (3D) printing in an effort to accelerate the degradation kinetics of β-TCP. METHODS:Twenty-two 1-month-old New Zealand white rabbits underwent creation of calvarial and alveolar defects, repaired with 3D-printed β-TCP scaffolds coated with 1000 μM of osteogenic agent dipyridamole. Rabbits were euthanized after 2, 6, and 18 months after surgical intervention. Bone regeneration, scaffold degradation, and bone mechanical properties were quantified. RESULTS:Histological analysis confirmed the generation of vascularized and organized bone. Microcomputed tomography analysis from 2 to 18 months demonstrated decreased scaffold volume within calvarial (23.6% ± 2.5%, 5.1% ± 2.2%; P < 0.001) and alveolar (21.5% ± 2.2%, 0.2% ± 1.9%; P < 0.001) defects, with degradation rates of 54.6%/year and 90.5%/year, respectively. Scaffold-inducted bone generation within the defect was volumetrically similar to native bone in the calvarium (55.7% ± 6.9% vs 46.7% ± 6.8%; P = 0.064) and alveolus (31.4% ± 7.1% vs 33.8% ± 3.7%; P = 0.337). Mechanical properties between regenerated and native bone were similar. CONCLUSIONS:Our study demonstrates an improved degradation profile and replacement of absorbed β-TCP with vascularized, organized bone through 3D printing and addition of an osteogenic agent. This novel additive manufacturing and tissue engineering protocol has implications to the future of craniofacial skeletal reconstruction as a safe and efficacious bone tissue engineering method.
PMCID:8616850
PMID: 34611100
ISSN: 1536-3708
CID: 5072082

Osseodensification Versus Subtractive Drilling Techniques in Bone Healing and Implant Osseointegration: Ex Vivo Histomorphologic/Histomorphometric Analysis in a Low-Density Bone Ovine Model

Mullings, Otto; Tovar, Nick; Abreu de Bortoli, João Paulo; Parra, Marcelo; Torroni, Andrea; Coelho, Paulo G; Witek, Lukasz
PURPOSE/OBJECTIVE:The aim of this study was to qualitatively and quantitatively assess the effect of osteotomy preparation by conventional, subtractive, or osseodensification instrumentation on osteotomies, treated with or without endosteal implants, and healing capacity. MATERIALS AND METHODS/METHODS:Seven sheep were used, and 56 osteotomies were made in the left and right ilium of the sheep (n = 8/sheep [4 per side/time point (3 and 6 weeks)]). Two different instrumentation techniques were used: (1) conventional/regular drilling in a three-step series of a 2-mm pilot and 3.2-mm and 3.8-mm twist drills and (2) osseodensification drilling with a Densah Bur 2.0-mm pilot and 2.8-mm and 3.8-mm multi-fluted tapered burs. Drilling was performed at 1,100 rpm with saline irrigation. RESULTS:Qualitative histomorphometric evaluation of the osteotomies after 3 and 6 weeks did not indicate any healing impairment due to the instrumentation. In all samples, histologic examination suggested bone remodeling and growth (empty and treated with an implant), irrespective of preparation technique. Osteotomies prepared using the osseodensification instrumentation showed the existence of bone chips autografted into the trabecular spaces along the length of the osteotomy wall. CONCLUSION/CONCLUSIONS:The osseodensification group yielded higher osseointegration rates, as distinguished through qualitative assessment, bone-to-implant contact, and bone-area-fraction occupancy, indicating an increased osteogenic potential in osteotomies prepared using the osseodensification technique.
PMID: 34698715
ISSN: 1942-4434
CID: 5072102

Three-Dimensionally-Printed Bioactive Ceramic Scaffolds: Construct Effects on Bone Regeneration

Fama, Christopher; Kaye, Gabriel J; Flores, Roberto; Lopez, Christopher D; Bekisz, Jonathan M; Torroni, Andrea; Tovar, Nick; Coelho, Paulo G; Witek, Lukasz
BACKGROUND/PURPOSE/OBJECTIVE:The utilization of three-dimensionally (3D)-printed bioceramic scaffolds composed of beta-tricalcium phosphate in conjunction with dipyridamole have shown to be effective in the osteogenesis of critical bone defects in both skeletally immature and mature animals. Furthermore, previous studies have proven the dura and pericranium's osteogenic capacity in the presence of 3D-printed scaffolds; however, the effect galea aponeurotica on osteogenesis in the presence of 3D scaffolds remains unclear. METHOD/DESCRIPTION/UNASSIGNED:Critical-sized (11 mm) bilateral calvarial defects were created in 35-day old rabbits (n = 7). Two different 3D scaffolds were created, with one side of the calvaria being treated with a solid nonporous cap and the other with a fully porous cap. The solid cap feature was designed with the intention of preventing communication of the galea and the ossification site, while the porous cap permitted such communication. The rabbits were euthanized 8 weeks postoperatively. Calvaria were analyzed using microcomputed tomography, 3D reconstruction, and nondecalcified histologic sectioning in order assess differences in bone growth between the two types of scaffolding. RESULTS:Scaffolds with the solid (nonporous) cap yielded greater percent bone volume (P = 0.012) as well as a greater percent potential bone (P = 0.001) compared with the scaffolds with a porous cap. The scaffolds with porous caps also exhibited a greater percent volume of soft tissue (P < 0.001) presence. There were no statistically significant differences detected in scaffold volume. CONCLUSION/CONCLUSIONS:A physical barrier preventing the interaction of the galea aponeurotica with the scaffold leads to significantly increased calvarial bone regeneration in comparison with the scaffolds allowing for this interaction. The galea's interaction also leads to more soft tissue growth hindering the in growth of bone in the porous-cap scaffolds.
PMID: 33003153
ISSN: 1536-3732
CID: 5050092

Effect of supplemental acid-etching on the early stages of osseointegration: A preclinical model

Benalcázar Jalkh, Ernesto B; Parra, Marcelo; Torroni, Andrea; Nayak, Vasudev Vivekanand; Tovar, Nick; Castellano, Arthur; Badalov, Rafael M; Bonfante, Estevam A; Coelho, Paulo G; Witek, Lukasz
PURPOSE:To evaluate the effect of two surface modifications on early osseointegration parameters of conical implants in a translational pre-clinical model. MATERIALS AND METHODS:), surface energy and contact angle. Subsequently, implants were installed in the ilium crest of nine female sheep (weighing ~65 kg). Torque out, histological and histomorphometric analyses were conducted after 3 and 6 weeks in-vivo. The percentage of bone to implant contact (%BIC) and bone area fraction occupancy within implant threads (%BAFO) were quantified, and the results were analyzed using a general linear mixed model analysis as function of surface treatment and time in-vivo. RESULTS:. Torque-out testing yielded significantly higher values for IMP Sur + AE in comparison to the IMP Sur at 3- (62.78 ± 15 and 33.49 ± 15 N.cm, respectively) and 6-weeks (60.74 ± 15 and 39.80 ± 15 N.cm, respectively). Histological analyses depicted similar osseointegration features for both surfaces, where an intramembranous-type healing pattern was observed. At histomorphometric analyses, IMP Sur + AE implants yielded higher values of BIC in comparison to IMP Sur at 3- (40.48 ± 38 and 27.98 ± 38%, respectively) and 6-weeks (45.86 ± 38 and 34.46 ± 38%, respectively). Both groups exhibited a significant increase in %BAFO from 3 (~35%) to 6 weeks (~44%), with no significant differences between surface treatments. CONCLUSION:Supplemental acid-etching and its interplay with implant thread design, positively influenced the BIC and torque-out resistance at early stages of osseointegration.
PMID: 34311324
ISSN: 1878-0180
CID: 4972492

Effects of relative centrifugation force on L-PRF: An in vivo submandibular boney defect regeneration study

Tovar, Nick; Benalcázar Jalkh, Ernesto B; Ramalho, Ilana S; Rodriguez Colon, Ricardo; Kim, Heoijin; Bonfante, Estevam A; Torroni, Andrea; Coelho, Paulo G; Witek, Lukasz
Properties and composition of leukocyte- and platelet-rich fibrin (L-PRF) clots may be largely affected by centrifugation protocols (function of relative centrifugal force [RCF]), which may impact biological potential repair in bone regeneration. The present in vivo study sought to assess the effect of the RCF on the composition of L-PRF clots, as well as to compare the repair potential of L-PRF clots obtained with different RCF protocols in submandibular boney defects using PLGA scaffolds for bone regeneration. Complete blood count and volumetric evaluations were performed on L-PRF clots obtained through centrifugation for 12 min at 200, 400, and 600 RCF-clot centrifugation speeds. These evaluations were completed from blood collected immediately prior to any surgical procedures. The in vivo portion comprised of three submandibular unilateral, full thickness, osteotomies (~0.40cm3 ) which were created in the submandibular region of six sheep, using rotary instrumentation under continuous irrigation. Subsequently, poly(lactic-co-glycolic acid) (PLGA) scaffolds were enveloped in a L-PRF membrane from one of the three spinning speeds (n = 6/RCF) and inserted into the defect (sites were interpolated to avoid site bias). Six-weeks after surgery, the mandibles were harvested en bloc and prepared for volumetric and histomorphometric evaluations. Membranes harvested from 600 RCF produced significantly larger L-PRF clots (6.97g ± 0.95) in comparison to the lower 200 RCF (5.7g ± 0.95), with no significant differences between 600 and 400, and from 400 and 200 RCF. The three tested RCFs did not alter the platelet count of the L-PRF clot. For the in vivo component, quantitative bone regeneration analyses demonstrated significantly higher values obtained with L-PRF membranes extracted post 600 RCF (27.01 ± 8%) versus 200 RCF (17.54 ± 8%), with no significant differences regarding 400 RCF (~23 ± 8%). At the qualitative histological analyses, L-PRF membranes obtained at 600 and 400 RCFs yielded improved healing throughout the defect, where the L-PRF sourced from the lowest speed, 200 RCF, presented healing primarily at the margins along with the presence of connective tissue at the central aspect of the surgical defect. Higher 600 RCF yielded larger L-PRF clots/membranes, resulting in enhanced bone repair potential in association with PLGA scaffolds for the treatment of critical size bone defects.
PMID: 34080775
ISSN: 1552-4981
CID: 4905812

Effect of Surgical Instrumentation Variables on the Osseointegration of Narrow- and Wide-Diameter Short Implants

Witek, Lukasz; Parra, Marcelo; Tovar, Nick; Alifarag, Adham; Lopez, Christopher D; Torroni, Andrea; Bonfante, Estevam A; Coelho, Paulo G
PURPOSE/OBJECTIVE:The aim of the present study was to systematically analyze how a multifactorial surgical instrumentation approach affects osseointegration on both narrow-diameter and wide-diameter short implants. MATERIALS AND METHODS/METHODS:Twelve skeletally mature female sheep were used in the study along with 144 plateau-root-form healing chamber titanium (Ti-6Al-4V) implants (Bicon LLC, Boston, MA), evenly distributed between narrow (3.5 mm) and wide (6.0 mm) diameters. The presence or the absence of irrigation, different drilling speeds, and 2 time points quantifying bone-implant contact (BIC) and bone area fraction occupancy (BAFO) to evaluate the osteogenic parameters around the implants. RESULTS:There were no signs of inflammation, infection, or failure of the implants observed at either healing period. The narrow 3.5-mm implant, at 6 weeks, yielded significant differences in terms of BIC at a drilling speed of 50 rotations per minute (RPM), with higher values of the samples using irrigation (30.6 ± 6.1%) compared with those without (19.7 ± 6.1%). No statistical differences were detected for 500 and 1,000 RPM with or without irrigation. The wide 6-mm diameter implant showed differences with respect to drilling speed, 500 and 1,000 RPM, with higher values associated with samples subjected to irrigation. BAFO results, for both diameters, only detected statistical differences between the 2 times (3 vs 6 weeks); no statistical differences were detected when evaluating as a function of time, drilling speed, and irrigation. CONCLUSIONS:Surgical instrumentation variables (ie, drilling speed [RPM] and irrigation) yielded to be more of an effect for BIC at longer healing time (6 weeks) for the wider implants. Furthermore, deploying narrow or wide plateau-root-form implants, where conditions allow, has shown to be a safe alternative, considering the high BIC and BAFO values observed, independent of irrigation.
PMID: 33137302
ISSN: 1531-5053
CID: 4759432

Osseodensification drilling vs conventional manual instrumentation technique for posterior lumbar fixation: Ex-vivo mechanical and histomorphological analysis in an ovine model

Torroni, Andrea; Lima Parente, Paulo Eduardo; Witek, Lukasz; Hacquebord, Jacques Henri; Coelho, Paulo G
Lumbar fusion is a procedure associated with several indications, but screw failure remains a major complication, with an incidence ranging 10% to 50%. Several solutions have been proposed, ranging from more efficient screw geometry to enhance bone quality, conversely, drilling instrumentation have not been thoroughly explored. The conventional instrumentation (regular [R]) techniques render the bony spicules excavated impractical, while additive techniques (osseodensification [OD]) compact them against the osteotomy walls and predispose them as nucleating surfaces/sites for new bone. This work presents a case-controlled split model for in vivo/ex vivo comparison of R vs OD osteotomy instrumentation in posterior lumbar fixation in an ovine model to determine feasibility and potential advantages of the OD drilling technique in terms of mechanical and histomorphology outcomes. Eight pedicle screws measuring 4.5 mm × 45 mm were installed in each lumbar spine of eight adult sheep (four per side). The left side underwent R instrumentation, while the right underwent OD drilling. The animals were killed at 6- and 12-week and the vertebrae removed. Pullout strength and non-decalcified histologic analysis were performed. Significant mechanical stability differences were observed between OD and R groups at 6- (387 N vs 292 N) and 12-week (312 N vs 212 N) time points. Morphometric analysis did not detect significant differences in bone area fraction occupancy between R and OD groups, while it is to note that OD showed increased presence of bone spiculae. Mechanical pullout testing demonstrated that OD drilling provided higher degrees of implant anchoring as a function of time, whereas a significant reduction was observed for the R group.
PMID: 32369220
ISSN: 1554-527x
CID: 4439042

Three-Dimensional Printing for Craniofacial Bone Tissue Engineering

Shen, Chen; Witek, Lukasz; Flores, Roberto L; Tovar, Nick; Torroni, Andrea; Coelho, Paulo G; Kasper, F Kurtis; Wong, Mark; Young, Simon
The basic concepts from the fields of biology and engineering are integrated into tissue engineering to develop constructs for the repair of damaged and/or absent tissues, respectively. The field has grown substantially over the past two decades, with particular interest in bone tissue engineering (BTE). Clinically, there are circumstances in which the quantity of bone that is necessary to restore form and function either exceeds the patient's healing capacity or bone's intrinsic regenerative capabilities. Vascularized osseous or osteocutaneous free flaps are the standard of care with autologous bone remaining the gold standard, but is commonly associated with donor site morbidity, graft resorption, increased operating time, and cost. Regardless of the size of a craniofacial defect, from trauma, pathology, and osteonecrosis, surgeons and engineers involved with reconstruction need to consider the complex three-dimensional (3D) geometry of the defect and its relationship to local structures. Three-dimensional printing has garnered significant attention and presents opportunities to use craniofacial BTE as a technology that offers a personalized approach to bony reconstruction. Clinicians and engineers are able to work together to produce patient-specific space-maintaining scaffolds tailored to site-specific defects, which are osteogenic, osseoconductive, osseoinductive, encourage angiogenesis/vasculogenesis, and mechanically stable upon implantation to prevent immediate failure. In this work, we review biological and engineering principles important in applying 3D printing technology to BTE for craniofacial reconstruction as well as present recent translational advancements in 3D printed bioactive ceramic scaffold technology.
PMCID:7759279
PMID: 32842918
ISSN: 1937-335x
CID: 4751522