Searched for: in-biosketch:true
person:chandh02
Utility of the apparent diffusion coefficient for distinguishing clear cell renal cell carcinoma of low and high nuclear grade
Rosenkrantz, Andrew B; Niver, Benjamin E; Fitzgerald, Erin F; Babb, James S; Chandarana, Hersh; Melamed, Jonathan
OBJECTIVE: The purpose of our study was to assess the utility of the apparent diffusion coefficient (ADC) in distinguishing low-grade and high-grade clear cell renal cell carcinoma (ccRCC). MATERIALS AND METHODS: The cases of 57 patients with pathologically proven ccRCC who underwent preoperative MRI, including diffusion-weighted imaging, were retrospectively assessed. ADC values were obtained from ADC maps calculated using b-value combinations of 0 and 400 s/mm(2) and of 0 and 800 s/mm(2) (hereafter referred to as ADC-400 and ADC-800). Lesions were also evaluated for an array of conventional MRI features. A single expert uropathologist reviewed all slides to determine nuclear grade. The utility of ADC for detecting high-grade ccRCC, alone and in combination with conventional MRI features, was assessed using receiver operating characteristic (ROC) analysis and binary logistic regression. RESULTS: ADC-400 and ADC-800 were significantly lower among high-grade than among low-grade ccRCC (2.24 +/- 0.50 mm(2)/s vs 1.59 +/- 0.57 mm(2)/s for ADC-400, p < 0.001; 1.85 +/- 0.40 mm(2)/s vs 1.28 +/- 0.48 mm(2)/s for ADC-800; p < 0.001). The area under the ROC curve for identifying high-grade ccRCC using ADC-400 and ADC-800 was 0.801 and 0.824 respectively (p = 0.606), with optimal thresholds, sensitivity, and specificity as follows: ADC-400: 2.17 mm(2)/s, 88.5%, 64.5% and ADC-800: 1.20 mm(2)/s, 65.4%, 96.0%. Using multivariate logistic regression, only necrosis (p = 0.0229) and perinephric fat invasion (p = 0.0160) were retained among conventional imaging features as independent risk factors for high-grade ccRCC. The accuracy of the logistic regression model for predicting high-grade ccRCC was significantly improved by inclusion of either ADC-400 (p = 0.0143) or ADC-800 (p = 0.015). CONCLUSION: ADC is significantly lower in high-grade ccRCC compared with low-grade ccRCC and increases the accuracy for detecting high-grade ccRCC compared with conventional MRI features alone
PMID: 20966299
ISSN: 1546-3141
CID: 114050
Diffusion-weighted MRI and liver metastases
Chandarana, Hersh; Taouli, Bachir
Liver metastases are the most frequently encountered malignant liver lesions in the Western countries. Accurate diagnosis of liver metastases is essential for appropriate management of these patients. Multiple imaging modalities, including ultrasound, CT, positron emission tomography, and MRI, are available for the evaluation of patients with suspected or known liver metastases. Contrast-enhanced MRI has a high accuracy for detection and characterization of liver lesions. Additionally, diffusion-weighted MRI (DWI) has been gaining increasing attention. It is a noncontrast technique that is easy to perform, could be incorporated in routine clinical protocols, and has the potential to provide tissue characterization. This article discusses the basic principles of DWI and discusses its emerging role in the detection of liver metastases in patients with extrahepatic malignancies
PMID: 21094449
ISSN: 1557-9786
CID: 114837
Dual energy CT: preliminary observations and potential clinical applications in the abdomen
Graser, Anno; Johnson, Thorsten R C; Chandarana, Hersh; Macari, Michael
Dual energy CT (DECT) is a new technique that allows differentiation of materials and tissues based on CT density values derived from two synchronous CT acquisitions at different tube potentials. With the introduction of a new dual source CT system, this technique can now be used routinely in abdominal imaging. Potential clinical applications include evaluation of renal masses, liver lesions, urinary calculi, small bowel, pancreas, and adrenal glands. In CT angiography of abdominal aortic aneurysms, dual energy CT techniques can be used to remove bones from the datasets, and virtual unenhanced images allow differentiation of contrast agent from calcifying thrombus in patients with endovascular stents. This review describes potential applications, practical guidelines, and limitations of dual energy CT in the abdomen
PMID: 18677487
ISSN: 1432-1084
CID: 95303
CT and MR Appearances of Cardiac Pseudomasses: Imaging Pearls and Pitfalls (CME Credit Available) [Meeting Abstract]
Rueff, L; Srichai, M; Jacobs, J; Chandarana, H; Axel, L; Kim, D; Lim, R
ISI:000265387200308
ISSN: 0361-803x
CID: 99182
Gender Normalized Reference Values of Heart and Great Vessel Dimensions in Cardiac CT (CME Credit Available) [Meeting Abstract]
Nevsky, G; Jacobs, J; Kim, D; Chandarana, H; Donnino, R; Lim, R; Srichai, M
ISI:000265387200296
ISSN: 0361-803x
CID: 99181
Renal functional MRI: Are we ready for clinical application?
Chandarana, Hersh; Lee, Vivian S
OBJECTIVE: We review the basics of functional renal imaging and highlight a few clinical applications. CONCLUSION: Techniques such as contrast-enhanced MR renography, diffusion-weighted imaging, and blood oxygen level-dependent MRI have been investigated in animal models and in a few human studies. Functional renal imaging is a rapidly growing field that has the potential to provide new insight into the pathophysiology of renal disease
PMID: 19457818
ISSN: 1546-3141
CID: 99026
MRI FEATURES OF HCC DO NOT PREDICT MICROVASCULAR INVASION IN LIVER TRANSPLANT FOR HEPATOCELLULAR CARCINOMA [Meeting Abstract]
Robinson, E; Chandarana, H; Droxhinin, L; Hajdu, C; Xu, RL; Teperman, L; Taouli, B
ISI:000267792300132
ISSN: 1527-6465
CID: 101245
Hepatic iron deposition in patients with liver disease: preliminary experience with breath-hold multiecho T2*-weighted sequence
Chandarana, Hersh; Lim, Ruth P; Jensen, Jens H; Hajdu, Cristina H; Losada, Mariela; Babb, James S; Huffman, Steve; Taouli, Bachir
OBJECTIVE: The purpose of this study was to conduct, using histopathologic examination as the reference standard, a preliminary evaluation of the use of a breath-hold multiecho T2(*)-weighted MRI sequence in the detection and quantification of hepatic iron deposition in patients with liver disease. MATERIALS AND METHODS: The images of 43 patients with liver disease who underwent 1.5-T MRI of the liver that included a multiecho T2(*)-weighted sequence who also underwent concomitant liver biopsy or liver transplantation were assessed. Two independent observers measured hepatic T2(*) by placing regions of interest in the hepatic parenchyma. Hepatic T2(*) values were compared between patients stratified by hepatic iron grade and were correlated with histopathologic iron grade. Receiver operating characteristics analysis was performed to assess the accuracy of images obtained with the hepatic T2(*)-weighted sequence in the diagnosis of iron deposition. RESULTS: Patients with iron deposition had shorter hepatic T2(*) values than did patients without iron deposition (mean T2(*), 17.7 vs 32.3 milliseconds with pooled data from both observers; p < 0.0001). Patients with iron grade 3 or greater had shorter T2(*) values than those with iron grade 2 or less (10.1 vs 20.8 milliseconds; p < 0.0001). There was a strong negative correlation between hepatic T2(*) and histopathologic iron grade (r = -0.849; p < 0.0001). For the prediction of iron grades 1 or greater and 3 or greater, area under the curve, sensitivity, and specificity were 0.968-0.982, 90.5-100%, and 100-97.3% at T2(*) cutoffs of less than 24 and less than 14 milliseconds, respectively. CONCLUSION: Hepatic iron overload in patients with liver disease can be assessed rapidly and accurately with MRI performed with a breath-hold T2(*)-weighted sequence
PMID: 19843739
ISSN: 1546-3141
CID: 104735
Abdominal aorta: evaluation with dual-source dual-energy multidetector CT after endovascular repair of aneurysms--initial observations
Chandarana, Hersh; Godoy, Myrna C B; Vlahos, Ioannis; Graser, Anno; Babb, James; Leidecker, Christianne; Macari, Michael
PURPOSE: To evaluate the possible radiation dose reduction facilitated by using dual-energy (DE) multidetector computed tomography (CT) after endovascular repair of abdominal aortic aneurysms (AAAs). MATERIALS AND METHODS: This prospective study was HIPAA compliant and institutional review board approved. Twenty-two patients who previously had undergone endovascular repair of AAAs underwent 24 DE multidetector CT examinations, which were performed with a 64-detector scanner. Initial nonenhanced CT was followed by arterial phase and venous phase acquisitions. Virtual nonenhanced, pure 80-kVp, and weighted-average peak voltage CT data sets were generated from the venous acquisition. Two independent readers interpreted the virtual nonenhanced and DE weighted-average CT data for the presence or absence of endoleaks. These interpretations were compared with the clinical interpretations of the data performed by a different radiologist by using true nonenhanced, arterial phase, and venous phase data. Region-of-interest measurements of the abdominal aorta and of the region of the endoleaks were obtained. Effective radiation dose was calculated. RESULTS: Both independent readers' interpretations of the virtual nonenhanced and weighted-average venous CT data revealed six type II endoleaks. There were no false-positive or false-negative findings. Aortic attenuation during the arterial, 80-kVp venous, and weighted-average data acquisitions were 288, 213, and 150 HU, respectively. The attenuation of the endoleaks was higher during the 80-kVp acquisition (P < .03) than during the arterial phase and weighted-average venous phase acquisitions. The mean effective dose for DE venous phase CT was 11.1 mSv compared with 27.8 mSv for standard triple-phase CT with a single-source configuration. CONCLUSION: Preliminary observations suggest that obtaining DE multidetector CT data by using a single 60-second contrast material-enhanced acquisition may be all that is required for surveillance after endovascular repair of AAA
PMID: 18812561
ISSN: 1527-1315
CID: 93372
Signal characteristic and enhancement patterns of pancreatic adenocarcinoma: evaluation with dynamic gadolinium enhanced MRI
Chandarana, H; Babb, J; Macari, M
AIM: To determine the signal characteristics and enhancement patterns of proven pancreatic adenocarcinomas at 1.5 T and to compare these results with contrast enhanced computed tomography (CECT). MATERIALS AND METHODS: Twenty-five patients, mean age 73 years, with proven pancreatic adenocarcinoma were imaged at 1.5 T using in- and opposed-phase, gradient-echo (GRE), T1-weighted sequences, T2 weighting using either a short tau inversion recovery (STIR) or frequency selective, fat-suppressed turbo spin echo (TSE) sequence, and with a three-dimensional (3D), fat-suppressed, GRE T1 sequence before, during the arterial, venous, and equilibrium phases after Gadolinium administration. Fourteen of the 25 patients underwent CECT. Magnetic resonance imaging (MRI) examinations were evaluated by two observers in consensus for size, signal characteristics, and enhancement patterns, and the results were compared with CECT. RESULTS: The mean size of pancreatic adenocarcinomas was 32mm. On unenhanced T1-weighted images, 12 of 25 lesions (48%) were hypointense, 13 (52%) were isointense. On STIR/T2, 11 of 25 (44%) pancreatic adenocarcinomas were hyperintense, 14 (56%) were isointense. All 25 (100%) adenocarcinomas were hypointense during the arterial phase. Twenty (80%) and 17 (68%) remained hypointense in the venous phase and equilibrium phases, respectively. In seven of 14 (50%) cases, the pancreatic mass was iso-attenuating to the pancreatic parenchyma during both the pancreatic and venous phases of CECT. CONCLUSION: The results of the present study showed that all 25 pancreatic adenocarcinomas were hypointense to pancreatic parenchyma during the arterial phase. Moreover, MRI may be useful in patients with a high suspicion of pancreatic carcinoma that is not visualized during CECT
PMID: 17662736
ISSN: 0009-9260
CID: 73893