Searched for: in-biosketch:true
person:raze01
Foreign Body Emboli following Cerebrovascular Interventions: Clinical, Radiographic, and Histopathologic Features
Shapiro, M; Ollenschleger, M D; Baccin, C; Becske, T; Spiegel, G R; Wang, Y; Song, X; Raz, E; Zumofen, D; Potts, M; Nelson, P K
Foreign material emboli following cerebral, cardiac, and peripheral catheterizations have been reported since the mid-1990s. Catheter coatings have been frequently implicated. The most recent surge of interest in this phenomenon within the neurointerventional community is associated with procedures using flow-diversion devices for the treatment of cerebral aneurysms. Following coil-supported Pipeline embolization in 4 cases and stent-supported coiling in 1, 5 patients developed multiple subcentimeter enhancing lesions, usually with surrounding edema and variable magnetic susceptibility in the vascular territories of the treated aneurysms. Conventional angiography findings were unrevealing. Laboratory work-up showed mild CSF protein elevation with no leukocytosis. Brain biopsy in 2 cases revealed granulomatous angiitis encasing foreign material, identical in stain appearance to a polyvinylpyrrolidone catheter coating. Corticosteroid administration typically produced clinical improvement. A heterogeneous radiographic and clinical course was noted, with rise and fall in the number of enhancing lesions in 2 patients and persistence in others. The etiology may be related to widespread adoption of increasingly sophisticated catheterization techniques.
PMID: 26294650
ISSN: 1936-959x
CID: 1732492
Cerebral Peduncle Angle: An Objective Criterion for Assessing Progressive Supranuclear Palsy Richardson Syndrome
Fatterpekar, Girish M; Dietrich, August; Pantano, Patrizia; Saba, Luca; Knopp, Edmond A; Piattella, Maria Cristina; Raz, Eytan
OBJECTIVE: Several criteria for time-consuming volumetric measurements of progressive supranuclear palsy Richardson syndrome subtype (PSP-RS) have been proposed. These often require image reconstruction in different planes for proper assessment. The purpose of this study was to evaluate the cerebral peduncle angle as a simple and reproducible measure of midbrain atrophy in patients with PSP-RS. MATERIALS AND METHODS: The records of 15 patients with PSP-RS were retrospectively identified. The records of 31 age-matched healthy control subjects, 15 patients with multiple-system atrophy, and 22 patients with Parkinson disease were included for comparison. Two neuroradiologists individually assessed these studies for midbrain atrophy by evaluating the cerebral peduncle angle, that is, the angle between the two cerebral peduncles. RESULTS: The cerebral peduncle angle measurements were 62.1 degrees (SD, 6.8 degrees ) in PSP-RS patients, 51.2 degrees (SD, 10.1 degrees ) in healthy control subjects, 55.7 degrees (SD, 11.6 degrees ) in patients with multiple-system atrophy, and 53.7 degrees (SD, 8.5 degrees ) in patients with Parkinson disease. A statistically significant difference was found in the cerebral peduncle angle measurements (observer 1, p = 0.015; observer 2, p = 0.004) between the PSP-RS patients and the other subgroups. Bland-Altman analysis showed a bias of 0.6 degrees (95% limits of agreement, 6.9 degrees , -5.8 degrees ), and intraobserver variability analysis showed a bias of 0.5 degrees (4.1 degrees , -3 degrees ). CONCLUSION: The cerebral peduncle angle is a simple, easy-to-calculate, and reproducible measure of midbrain atrophy. It is a useful criterion for differentiating patients with PSP-RS from healthy persons and from patients with multiple-system atrophy or Parkinson disease.
PMID: 26204292
ISSN: 1546-3141
CID: 1684062
Evaluation of the orbit using contrast-enhanced radial 3D fat-suppressed T1-weighted gradient-echo (Radial-VIBE) sequence
Bangiyev, Lev; Raz, Eytan; Block, Tobias; Hagiwara, Mari; Wu, Xin; Yu, Eugene; Fatterpekar, Girish M
OBJECTIVES: Contrast-enhanced fat-suppressed T1-weighted-2D-TSE and MPRAGE sequence with water excitation are routinely obtained to evaluate orbit pathology. However, these sequences can be marred by artifacts. The Radial-VIBE sequence is a motion-robust fat-suppressed T1W sequence which has demonstrated value in pediatric and body imaging. The purpose of our study is to evaluate its role in assessing the orbit, and to compare it with routinely acquired sequences. METHODS: A HIPAA-compliant and IRB-approved retrospective study was performed in 46 patients (age range: 1-81 years) who underwent orbit studies on a 1.5-T MRI using contrast-enhanced Radial-VIBE, MPRAGE and 2D-TSE sequences. Two radiologists blinded to the sequence analyzed evaluated multiple parameters of image quality including motion artifact, degree of fat-suppression, clarity of choroidal enhancement, intraorbital vessels, extraocular muscles, optic nerves, brain parenchyma and evaluation of pathology. Each parameter was assessed on a 5-point scale, with a higher score indicating the more optimal exam. Mix-model analysis of variance and interobserver variability were assessed. RESULTS: Radial-VIBE demonstrated superior quality (p<0.001) for all orbit parameters when compared to MPRAGE and 2D-TSE. Interobserver agreement demonstrated average fair-to -good agreement for: degree of motion artifact (0.745), fat suppression (0.678), clarity of choroidal enhancement (0.688), vessels (0.655), extraocular muscles (0.675), optic nerves (0.518), brain parenchyma (0.710), and evaluation of pathology (0.590). CONCLUSION: Radial-VIBE sequence demonstrates superior image quality when evaluating the orbits as compared to conventional MPRAGE and 2D-TSE sequences. Advances in knowledge: Radial-VIBE employs unique non-Cartesian k-space sampling in a radial or spoke-wheel fashion which provides superior image quality improving diagnostic capability in evaluation of the orbits.
PMCID:4730962
PMID: 26194589
ISSN: 1748-880x
CID: 1683772
Endoluminal Reconstruction for Nonsaccular Aneurysms of the Proximal Posterior Cerebral Artery with the Pipeline Embolization Device
Zumofen, D W; Shapiro, M; Becske, T; Raz, E; Potts, M B; Riina, H A; Nelson, P K
BACKGROUND AND PURPOSE: Treatment options for nonsaccular posterior cerebral artery aneurysms include a range of surgical and endovascular reconstructive and deconstructive methods. However, no truly satisfactory treatment option is available to date for lesions arising from the P1 and P2 segments. The purpose of the present case series is to investigate both the efficacy and safety of the Pipeline Embolization Device in treating these challenging aneurysms. MATERIALS AND METHODS: We present a series of 6 consecutive patients who underwent endoluminal reconstruction with the Pipeline Embolization Device for nonsaccular P1 or P2 segment aneurysms between January 2009 and June 2013. RESULTS: Aneurysm location included the P1 segment in 2 patients and the P2 segment in 4 patients. Mean aneurysm diameter was 23 mm (range, 5-44 mm). Mean length of the arterial segment involved was 10 mm (range, 6-19 mm). Clinical presentation included mass effect in 4 patients and perforator stroke and subacute aneurysmal subarachnoid hemorrhage in 1 patient each. Endovascular reconstruction was performed by using 1 Pipeline Embolization Device in 5 patients and 2 overlapping Pipeline Embolization Devices in the remaining patient. Angiographic aneurysm occlusion was immediate in 1 patient, within 6 months in 4 patients, and within 1 year in the remaining patient. Index symptoms resolved in 4 patients and stabilized in the remaining 2. No new permanent neurologic sequelae and no aneurysm recurrence were recorded during the mean follow-up period of 613 days (range, 540-725 days). CONCLUSIONS: Endovascular reconstruction with the Pipeline Embolization Device for nonsaccular aneurysms arising from the P1 and P2 segments compares favorably with historical treatment options in terms of occlusion rate, margin of safety, and neurologic outcome.
PMID: 25792531
ISSN: 1936-959x
CID: 1669452
Use of Pipeline Embolization Devices for treatment of a direct carotid-cavernous fistula
Nossek, E; Zumofen, D; Nelson, E; Raz, E; Potts, M B; Desousa, K G; Tanweer, O; Shapiro, M; Becske, T; Riina, Howard A
BACKGROUND: The use of minimally porous endoluminal devices (MPEDs) such as the Pipeline Embolization Device (PED) has been described for the treatment of brain aneurysms. The benefit of using MPEDs to assist embolization of a direct high-flow carotid cavernous fistula resulting from a ruptured cavernous carotid artery aneurysm is not well documented. METHODS: We describe our experience with deploying a tailored multidevice PED construct across the cavernous internal carotid artery (ICA) wall defect in combination with transarterial coil embolization using the "jailed microcatheter" technique. RESULTS: A 59-year-old woman presented with acute left-sided ophthalmoplegia. Diagnostic cerebral angiography demonstrated a ruptured giant cavernous carotid aneurysm with fistulous outflow via the ipsilateral left superior ophthalmic vein and into the pterygoid venous plexi bilaterally. Via the Marksman microcatheter, a total of three PEDs measuring 4.5 mm x 18 mm, 4.5 mm x 20 mm, and 4.75 mm x 16 mm were telescoped within the ICA across the aneurysm neck. Coiling of the aneurysm fundus and cavernous sinus via the "jailed" Rapidtransit microcatheter was subsequently achieved. A 2-year follow-up digital subtraction angiography (DSA) demonstrated stable obliteration of the aneurysm and the fistula, coincident with complete resolution of the patient's symptoms. CONCLUSIONS: Based on our long-term clinical and angiographic results, we advocate that the presented method be a valid treatment option for selected cases.
PMID: 25981434
ISSN: 0942-0940
CID: 1630972
Turning Point of Acute Stroke Therapy: Mechanical Thrombectomy as a Standard of Care
DeSousa, Keith G; Potts, Matthew B; Raz, Eytan; Nossek, Erez; Riina, Howard A
PMID: 25836270
ISSN: 1878-8750
CID: 1519652
Vertebral augmentation for neoplastic lesions with posterior wall erosion and epidural mass
Cianfoni, A; Raz, E; Mauri, S; Di Lascio, S; Reinert, M; Pesce, G; Bonaldi, G
BACKGROUND AND PURPOSE: The presence of a cortical erosion of the posterior wall or an epidural mass is commonly considered a contraindication to performing a vertebral augmentation, considering the perceived increased risk of an epidural cement leak. Our aim was to assess technical and clinical complications of vertebral augmentation procedures performed for pain palliation and/or stabilization of neoplastic lytic vertebral body lesions, with cortical erosion of the posterior wall, often associated with a soft-tissue epidural mass. MATERIALS AND METHODS: In 48 patients, we performed retrospective vertebral augmentation assessment on 70 consecutive levels with cortical erosion of the posterior wall, as demonstrated by preprocedural CT/MR imaging. An epidural mass was present in 31/70 (44.3%) levels. Cavity creation was performed with Coblation Wands before cement injection in 59/70 levels. Injection of high-viscosity polymethylmethacrylate was performed under real-time continuous fluoroscopic control. Postprocedural CT of the treated levels was performed in all cases. Clinical follow-up was performed at 1 and 4 weeks postprocedurally. RESULTS: In 65/70 (92.8%) levels, the vertebral augmentation resulted in satisfactory polymethylmethacrylate filling of the lytic cavity and adjacent trabecular spaces in the anterior half of the vertebral body. An epidural leak of polymethylmethacrylate occurred in 10/70 (14.2%) levels, causing radicular pain in 3 patients, which spontaneously resolved within 1 week in 2 patients, while 1 patient with a T1-T2 foraminal leak developed severe weakness of the intrinsic hand muscles and a permanent motor deficit. CONCLUSIONS: In our series of vertebral augmentation of neoplastic lytic vertebral lesions performed for palliation of pain and/or stabilization, we observed a polymethylmethacrylate epidural leak in only 14.2% of levels, despite the presence of cortical erosion of the posterior wall and an epidural mass, with an extremely low rate of clinical complications. Our data seem to justify use of vertebral augmentation in patients with intractable pain or those at risk for vertebral collapse.
PMID: 25213884
ISSN: 0195-6108
CID: 1464792
Anterior Choroidal Artery Patency and Clinical Follow-Up after Coverage with the Pipeline Embolization Device
Raz, E; Shapiro, M; Becske, T; Zumofen, D W; Tanweer, O; Potts, M B; Riina, H A; Nelson, P K
BACKGROUND AND PURPOSE: Endoluminal reconstruction with the Pipeline Embolization Device is an effective treatment option for select intracranial aneurysms. However, concerns for the patency of eloquent branch arteries covered by the Pipeline Embolization Device have been raised. We aimed to examine the patency of the anterior choroidal artery and clinical sequelae after ICA aneurysm treatment. MATERIALS AND METHODS: We prospectively analyzed all patients among our first 157 patients with ICA aneurysms treated by the Pipeline Embolization Device who required placement of at least 1 device across the ostium of the anterior choroidal artery. The primary outcome measure was angiographic patency of the anterior choroidal artery at last follow-up. Age, sex, type of aneurysm, neurologic examination data, number of Pipeline Embolization Devices used, relationship of the anterior choroidal artery to the aneurysm, and completeness of aneurysm occlusion on follow-up angiograms were also analyzed. RESULTS: Twenty-nine aneurysms requiring placement of at least 1 Pipeline Embolization Device (median = 1, range = 1-3) across the anterior choroidal artery ostium were identified. At angiographic follow-up (mean = 15.1 months; range = 12-39 months), the anterior choroidal artery remained patent, with antegrade flow in 28/29 aneurysms (96.5%), while 24/29 (82.7%) of the target aneurysms were angiographically occluded by 1-year follow-up angiography. Anterior choroidal artery occlusion, with retrograde reconstitution of the vessel, was noted in a single case. A significant correlation between the origin of the anterior choroidal artery from the aneurysm dome and failure of the aneurysms to occlude following treatment was found. CONCLUSIONS: After placement of 36 Pipeline Embolization Devices across 29 anterior choroidal arteries (median = 1 device, range = 1-3 devices), 1 of 29 anterior choroidal arteries was found occluded on angiographic follow-up. The vessel occlusion did not result in persistent clinical sequelae. Coverage of the anterior choroidal artery origin with the Pipeline Embolization Device, hence, may be considered reasonably safe when deemed necessary for aneurysm treatment.
PMID: 25572948
ISSN: 0195-6108
CID: 1432982
Is There an Association between Cerebral Microbleeds and Leukoaraiosis?
Saba, Luca; Raz, Eytan; Bassareo, Pier P; di Martino, Michele; de Cecco, Carlo Nicola; Mercuro, Giuseppe; Grassi, Roberto; Suri, Jasjit S; Piga, Mario
PURPOSE: Cerebral microbleeds (CMBs) are small dot-like lesions appearing as hyposignals on gradient echo (GRE) T2* magnetic resonance (MR) sequences, whereas the leukoaraiosis (LA) indicates the presence of patchy areas of hypersignal on fluid-attenuated inversion recovery (FLAIR) MR sequences in the periventricular white matter. The purpose of this work was to evaluate the association between LA and CMBs. MATERIAL AND METHODS: Eighty-five consecutive (men 55; median age 64 years) patients were retrospectively analyzed using a 1.5 T system; CMBs were studied using a T2*-weighted GRE sequence and classified as absent (grade 1), mild (grade 2; total number of microbleeds, 1-2), moderate (grade 3; total number of microbleeds, 3-10), and severe (grade 4; total number of microbleeds, >10). LA was assessed with FLAIR MR sequences and was graded based on the European Task Force on Age-Related White Matter Changes as follows: 1 (no lesions), 2 (focal lesions > 5 mm), 3 (early confluent lesions), and 4 (diffuse involvement of an entire brain region). RESULTS: We considered 170 cerebral hemispheres. The prevalence of CMBs was 24.7% (42 of 170), whereas the prevalence of LA was 27.1% (46 of 170). A statistically significant correlation was observed between LA and CMBs (correlation rho = .495, P value = .001). Multiple logistic regression analysis showed an association between CMBs and cerebrovascular symptoms (P = .0023). CONCLUSION: Results of this study suggest an association between CMBs and LA. Moreover, we found that LA is associated with the presence of cerebrovascular symptoms.
PMID: 25440349
ISSN: 1052-3057
CID: 1370102
Relationship between iron accumulation and white matter injury in multiple sclerosis: a case-control study
Raz, Eytan; Branson, Brittany; Jensen, Jens H; Bester, Maxim; Babb, James S; Herbert, Joseph; Grossman, Robert I; Inglese, Matilde
Despite the increasing development and applications of iron imaging, the pathophysiology of iron accumulation in multiple sclerosis (MS), and its role in disease progression and development of clinical disability, is poorly understood. The aims of our study were to determine the presence and extent of iron in T2 visible lesions and gray and white matter using magnetic field correlation (MFC) MRI and correlate with microscopic white matter (WM) injury as measured by diffusion tensor imaging (DTI). This is a case-control study including a series of 31 patients with clinically definite MS. The mean age was 39 years [standard deviation (SD) = 9.55], they were 11 males and 20 females, with a disease duration average of 3 years (range 0-13) and a median EDSS of 2 (0-4.5). Seventeen healthy volunteers (6 males and 11 females) with a mean age of 36 years (SD = 11.4) were recruited. All subjects underwent MR imaging on a 3T scanner using T2-weighted sequence, 3D T1 MPRAGE, MFC, single-shot DTI and post-contrast T1. T2-lesion volumes, brain volumetry, DTI parameters and iron quantification were calculated and multiple correlations were exploited. Increased MFC was found in the putamen (p = 0.061), the thalamus (p = 0.123), the centrum semiovale (p = 0.053), globus pallidus (p = 0.008) and gray matter (GM) (p = 0.004) of MS patients compared to controls. The mean lesional MFC was 121 s-2 (SD = 67), significantly lower compared to the GM MFC (<0.0001). The GM mean diffusivity (MD) was inversely correlated with the MFC in the centrum semiovale (p < 0.001), and in the splenium of the corpus callosum (p < 0.001). Patients with MS have increased iron in the globus pallidus, putamen and centrum with a trend toward increased iron in all the brain structures. Quantitative iron evaluation of WM and GM may improve the understanding of MS pathophysiology, and might serve as a surrogate marker of disease progression.
PMCID:4452503
PMID: 25416468
ISSN: 0340-5354
CID: 1359352