Intestinal ischemia versus intramural hemorrhage: CT evaluation
Macari, Michael; Chandarana, Hersch; Balthazar, Emil; Babb, James
OBJECTIVE: We evaluated the capability of CT to depict findings that allowed differentiation of small-bowel ischemia from intramural hemorrhage. MATERIALS AND METHODS: Findings of 35 CT examinations (19 patients with small-bowel ischemia and 16 patients with intramural hemorrhage) were analyzed by two abdominal radiologists for the degree of wall thickening, location and length of involvement (short, <or = 15 cm; medium, 16-30 cm; or long, >30 cm), presence of hemoperitoneum, and pattern of attenuation. Patency and caliber of the superior mesenteric artery and vein were noted. Diagnosis was confirmed by laboratory findings, clinical parameters, and follow-up examinations, or at surgery. A Mann-Whitney U or Fisher's exact test was used to compare the two conditions for the following features: wall thickening, location and length of involvement, presence of hemoperitoneum, and appearance of the target sign. RESULTS: Among the 35 examinations, 18 abnormal segments with intramural hemorrhage and 19 abnormal segments with ischemia were identified. (Two patients with intramural hemorrhage each had two segments involved.) Mean bowel wall thickness was 11.7 mm (range, 4-25 mm) in patients with intramural hemorrhage and 4.0 mm (range, 1-9 mm) in patients with ischemia. Length of involvement was short in 14 segments with intramural hemorrhage and medium in four segments with intramural hemorrhage; none of the segments with intramural hemorrhage had long involvement. Among the segments with ischemia, length of involvement was medium in three and long in 16; none of the ischemic segments had short involvement. Fifteen (94%) of 16 segments with intramural hemorrhage and six (32%) of 19 segments with ischemia had hemoperitoneum. Seven of the 18 segments with intramural hemorrhage and nine of the 19 with ischemia had a target sign. Segments with intramural hemorrhage exhibited a higher statistically significant degree of wall thickening (p < 0.001), a shorter length of involvement (p < 0.0001), and a higher incidence of hemoperitoneum (p < 0.001) than did segments with ischemia. The two groups were not statistically different in location of involvement (p = 0.12) or in the incidence of the target sign (p = 0.18). CONCLUSION: Although some of the CT features overlap, a short segment involvement with wall thickening of 1 cm or greater is typical of intramural hemorrhage; a long segment involvement with wall thickening of less than 1 cm is typical of ischemia
PMID: 12490499
ISSN: 0361-803x
CID: 43879
Colorectal neoplasms: prospective comparison of thin-section low-dose multi-detector row CT colonography and conventional colonoscopy for detection
Macari, Michael; Bini, Edmund J; Xue, Xiaonan; Milano, Andrew; Katz, Seth S; Resnick, Daniel; Chandarana, Hersh; Krinsky, Glen; Klingenbeck, Klaus; Marshall, Christopher H; Megibow, Alec J
PURPOSE: To prospectively compare thin-section low-dose multi-detector row computed tomographic (CT) colonography with conventional colonoscopy for the detection of colorectal neoplasms. MATERIALS AND METHODS: One hundred five patients underwent CT colonography immediately before colonoscopy. Supine and prone CT colonographic acquisitions to image the region during a 30-second breath hold were performed. CT colonographic images were prospectively interpreted for the presence, location, size, and morphologic features of polyps. The time of image interpretation was noted. Sensitivity, specificity, and positive and negative predictive values of CT colonography were calculated, with 95% CIs, by using colonoscopic findings as the reference standard. The weighted CT dose index was calculated on the basis of measurements in a standard body phantom. Effective dose was calculated by using commercially available software. RESULTS: Median CT data interpretation time was 12 minutes. One hundred thirty-two polyps in 59 patients were identified at colonoscopy; no polyps were detected in 46 patients. Sensitivities for detection of polyps smaller than 5 mm, 6-9 mm, and larger than 10 mm in diameter were 12% (11 of 91 polyps), 70% (19 of 27 polyps), and 93% (13 of 14 polyps), respectively. Estimated overall specificity was 97.7% (515 of 527 imaging results). The total weighted CT dose index for combined supine and prone CT colonography was 11.4 mGy. The effective doses for combined CT colonography were 5.0 mSv and 7.8 mSv for men and women, respectively. CONCLUSION: Low-dose multi-detector row CT colonography has excellent sensitivity and specificity for detection of colorectal neoplasms 10 mm and larger
PMID: 12147833
ISSN: 0033-8419
CID: 32913