Try a new search

Format these results:

Searched for:

in-biosketch:true

person:rolanj01

Total Results:

250


Acceptance and Benefit of Electroacoustic Stimulation in Children

Spitzer, Emily R; Kay-Rivest, Emily; Waltzman, Susan B; O'Brien-Russo, Colleen A; Santacatterina, Michele; Roland, J Thomas; Landsberger, David M; Friedmann, David R
OBJECTIVE:Children with high-frequency severe-to-profound hearing loss and low-frequency residual hearing who do not derive significant benefit from hearing aids are now being considered for cochlear implantation. Previous research shows that hearing preservation is possible and may be desirable for the use of electroacoustic stimulation (EAS) in adults, but this topic remains underexplored in children. The goal of this study was to explore factors relating to hearing preservation, acceptance, and benefits of EAS for children. STUDY DESIGN:Retrospective review. SETTING:Tertiary academic medical center. PATIENTS:Forty children (48 ears) with preoperative low-frequency pure-tone averages of 75 dB HL or less at 250 and 500 Hz (n = 48). INTERVENTION:All patients underwent cochlear implantation with a standard-length electrode. MAIN OUTCOME MEASURE:Low-frequency audiometric thresholds, speech perception, and EAS usage were measured at initial stimulation, and 3 and 12 months postoperatively. Outcomes were compared between children with and without hearing preservation, and between EAS users and nonusers. RESULTS:Hearing was preserved at similar rates as adults but worse for children with an enlarged vestibular aqueduct. Fewer than half of children who qualified to use EAS chose to do so, citing a variety of audiologic and nonaudiologic reasons. No differences were detected in speech perception scores across the groups for words, sentences, or sentences in noise tests. CONCLUSIONS:Neither hearing preservation nor EAS use resulted in superior speech perception in children with preoperative residual hearing; rather, all children performed well after implantation.
PMID: 37167445
ISSN: 1537-4505
CID: 5503372

Slim Modiolar Electrode Placement in Candidates for Electroacoustic Stimulation

Kay-Rivest, Emily; Winchester, Arianna; McMenomey, Sean O; Jethanamest, Daniel; Roland, J Thomas; Friedmann, David R
OBJECTIVES:To determine rates of hearing preservation and performance in patients who met candidacy for electroacoustic stimulation (EAS) and were implanted with a slim modiolar electrode (CI532 or CI632). DESIGN:Adult patients meeting Food and Drug Administration criteria for electroacoustic stimulation (preoperative low-frequency pure-tone average [LFPTA] less than 60 dB at 125, 250, and 500 Hz and monosyllabic word scores between 10% and 60% in the ear to be implanted), who received a slim modiolar electrode were included. Main outcome measures included rates of hearing preservation, defined as a LFPTA ≤80 dB at 125, 250, and 500 Hz, as well as postoperative low-frequency pure-tone threshold shifts, consonant-Nucleus-Consonant (CNC) word scores and AzBio sentences in noise scores. RESULTS:Forty-six patients met inclusion criteria during a 4-year period. Mean (standard deviation) preoperative LFPTA was 34.5 (13.0) dB, and 71.7% had preserved hearing at initial activation. The mean LFPTA shift in patients who preserved hearing at initial activation was 19.7 (14.6) dB, compared with 62.6 (17.7) dB in patients who did not preserve hearing as per our definition. Perioperative steroid use was not different in patients with and without preserved hearing (X 2 (1, N = 46) = 0.19, p = .67, V = 0.06). One year after surgery, 57% of patients had a decline in LFPTA >80 dB and were no longer considered candidates for EAS, with 34.7% still retaining low-frequency thresholds ≤80 dB. CNC word scores at 1 year were 69.9% and 61.4% among individuals with and without preserved low-frequency hearing respectively, measured in their CI ear alone, in their regular listening condition of EAS or electric only ( t (32) = 1.13, p = 0.27, d = 0.39, 95% CI = -6.51, 22.86). Device use time did not differ between groups. Among adults with preserved residual hearing at 1 year (n = 16), 44% used EAS, although there was no significant difference in performance between EAS users and nonusers with preserved hearing. Loss of residual hearing over time did not result in a decline in speech perception performance. CONCLUSION:The present study demonstrated favorable early rates of hearing preservation with a slim modiolar array. Performance was not significantly different in individuals with and without preserved low-frequency acoustic hearing, independent of EAS use. Compared with reports of short electrode use, the loss of residual hearing in patients implanted with this array did not impact speech perception performance.
PMID: 36534657
ISSN: 1538-4667
CID: 5462082

Monitoring Cochlear Health With Intracochlear Electrocochleography During Cochlear Implantation: Findings From an International Clinical Investigation

O'Leary, S; Mylanus, E; Venail, F; Lenarz, T; Birman, C; Di Lella, F; Roland, J T; Gantz, B; Beynon, A; Sicard, M; Buechner, A; Lai, W K; Boccio, C; Choudhury, B; Tejani, V D; Plant, K; English, R; Arts, R; Bester, C
OBJECTIVES/OBJECTIVE:Electrocochleography (ECochG) is emerging as a tool for monitoring cochlear function during cochlear implant (CI) surgery. ECochG may be recorded directly from electrodes on the implant array intraoperatively. For low-frequency stimulation, its amplitude tends to rise or may plateau as the electrode is inserted. The aim of this study was to explore whether compromise of the ECochG signal, defined as a fall in its amplitude of 30% or more during insertion, whether transient or permanent, is associated with poorer postoperative acoustic hearing, and to examine how preoperative hearing levels may influence the ability to record ECochG. The specific hypotheses tested were threefold: (a) deterioration in the pure-tone average of low-frequency hearing at the first postoperative follow-up interval (follow-up visit 1 [FUV1], 4 to 6 weeks) will be associated with compromise of the cochlear microphonic (CM) amplitude during electrode insertion (primary hypothesis); (b) an association is observed at the second postoperative follow-up interval (FUV2, 3 months) (secondary hypothesis 1); and (c) the CM response will be recorded earlier during electrode array insertion when the preoperative high-frequency hearing is better (secondary hypothesis 2). DESIGN/METHODS:International, multi-site prospective, observational, between groups design, targeting 41 adult participants in each of two groups, (compromised CM versus preserved CM). Adult CI candidates who were scheduled to receive a Cochlear Nucleus CI with a Slim Straight or a Slim Modiolar electrode array and had a preoperative audiometric low-frequency average thresholds of ≤80 dB HL at 500, 750, and 1000 Hz in the ear to be implanted, were recruited from eight international implant sites. Pure tone audiometry was measured preoperatively and at postoperative visits (FUV1 and follow-up visit 2 [FUV2]). ECochG was measured during and immediately after the implantation of the array. RESULTS:From a total of 78 enrolled individuals (80 ears), 77 participants (79 ears) underwent surgery. Due to protocol deviations, 18 ears (23%) were excluded. Of the 61 ears with ECochG responses, amplitudes were <1 µV throughout implantation for 18 ears (23%) and deemed "unclear" for classification. EcochG responses >1 µV in 43 ears (55%) were stable throughout implantation for 8 ears and compromised in 35 ears. For the primary endpoint at FUV1, 7/41 ears (17%) with preserved CM had a median hearing loss of 12.6 dB versus 34/41 ears (83%) with compromised CM and a median hearing loss of 26.9 dB (p < 0.014). In assessing the practicalities of measuring intraoperative ECochG, the presence of a measurable CM (>1 µV) during implantation was dependent on preoperative, low-frequency thresholds, particularly at the stimulus frequency (0.5 kHz). High-frequency, preoperative thresholds were also associated with a measurable CM > 1 µV during surgery. CONCLUSIONS:Our data shows that CM drops occurring during electrode insertion were correlated with significantly poorer hearing preservation postoperatively compared to CMs that remained stable throughout the electrode insertion. The practicality of measuring ECochG in a large cohort is discussed, regarding the suggested optimal preoperative low-frequency hearing levels (<80 dB HL) considered necessary to obtain a CM signal >1 µV.
PMID: 36395515
ISSN: 1538-4667
CID: 5384932

Skull Base Aerosol Generating Cases Amidst the COVID-19 Pandemic: An Experience from the Epicenter

Dastagirzada, Yosef; Klauberg, Olga; Sheerin, Kathleen; Lieberman, Seth; Lebowitz, Richard; McMenomey, Sean; Sen, Chandranath; Roland, J Thomas; Golfinos, John G; Pacione, Donato
Soon after the World Health Organization declared the severe acute respiratory syndrome coronavirus 2 a global health emergency on January 30, 2020, New York City was plagued by the virus and its health system and economy pushed to their limits. The majority of the limited neurosurgical data in relation to COVID-19 is anecdotal and the higher theoretical risk of transmission of the virus among skull base aerosol generating (SBAG) cases has not been investigated or discussed in a neurosurgical population. We discuss a series of 13 patients who underwent 15 SBAG surgical procedures during the peak of COVID-19 in our hospital system and the protocols use perioperatively for their procedures. Our data support that with proper preoperative testing, a well-delineated surgical algorithm, and appropriate personal protective equipment, emergent/urgent cases can be done safely in hospitals that are currently experiencing high volumes of COVID-19 cases as we did in March to May of 2020.
PMCID:9272281
PMID: 35832935
ISSN: 2193-6331
CID: 5387592

HiRes ultra series cochlear implant field recall: failure rates and early outcomes

Winchester, Arianna; Kay-Rivest, Emily; Friedmann, David R; McMenomey, Sean O; Shapiro, William H; Roland, J Thomas; Waltzman, Susan; Jethanamest, Daniel
OBJECTIVE/UNASSIGNED:Evaluate rates of Advanced Bionics Ultra 3D/Ultra cochlear implant failure in the setting of a worldwide device recall and report surgical and auditory outcomes after revision. METHODS/UNASSIGNED:Retrospective chart review was performed for adult and pediatric patients implanted with at risk devices at our center from 2016 to 2020. Device failure rates, surgical, and auditory outcomes were recorded and analyzed. RESULTS/UNASSIGNED: = 0.95). DISCUSSION/UNASSIGNED:Patients with device failure due to this field action performed well after revision implantation. Patients with bilateral at-risk devices but evidence of unilateral failure may elect to undergo simultaneous empiric revision of the contralateral device. Three patients who elected to change device manufacturers on revision have variable results that require further investigation. CONCLUSIONS/UNASSIGNED:Patients requiring revision for a device field action overall perform well. At-risk devices continue to require monitoring as a growing number are likely to fail over time.
PMID: 36411064
ISSN: 1754-7628
CID: 5384122

Matched Comparison of Hearing Outcomes in Patients With Vestibular Schwannoma Treated With Stereotactic Radiosurgery or Observation

Schnurman, Zane; Gurewitz, Jason; Smouha, Eric; McMenomey, Sean O; Roland, J Thomas; Golfinos, John G; Kondziolka, Douglas
BACKGROUND:Previous studies comparing hearing outcomes in patients managed with stereotactic radiosurgery (SRS) and a watch-and-wait strategy were limited by small sample sizes that prevented controlling for potential confounders, including initial hearing status, tumor size, and age. OBJECTIVE:To compare hearing outcomes for patients with vestibular schwannomas (VS) managed with observation and SRS while controlling for confounders with propensity score matching. METHODS:Propensity score matching was used to compare 198 patients with unilateral VS with initial serviceable hearing (99 treated with SRS and 99 managed with observation alone) and 116 with initial class A hearing (58 managed with SRS and 58 with observation), matched by initial hearing status, tumor volume, age, and sex. Kaplan-Meier survival methods were used to compare risk of losing class A and serviceable hearing. RESULTS:Between patients with VS managed with SRS or observation alone, there was no significant difference in loss of class A hearing (median time 27.2 months, 95% CI 16.8-43.4, and 29.2 months, 95% CI 20.4-62.5, P = .88) or serviceable hearing (median time 37.7 months, 95% CI 25.7-58.4, and 48.8 months, 95% CI 38.4-86.3, P = .18). For SRS patients, increasing mean cochlear dose was not related to loss of class A hearing (hazard ratio 1.3, P = .17) but was associated with increasing risk of serviceable hearing loss (hazard ratio of 1.5 per increase in Gy, P = .017). CONCLUSION/CONCLUSIONS:When controlling for potential confounders, there was no significant difference in loss of class A or serviceable hearing between patients managed with SRS or with observation alone.
PMID: 36001782
ISSN: 1524-4040
CID: 5334982

Predictive Value of Transimpedance Matrix Measurements to Detect Electrode Tip Foldover

Kay-Rivest, Emily; McMenomey, Sean O; Jethanamest, Daniel; Shapiro, William H; Friedmann, David R; Waltzman, Susan B; Roland, J Thomas
OBJECTIVE:To evaluate the ability of the transimpedance matrix (TIM) measurement to detect cochlear implant electrode tip foldover by comparing results to a "gold standard," the intraoperative plain film radiograph. STUDY DESIGN/METHODS:Retrospective case series. SETTING/METHODS:Tertiary referral hospital. PATIENTS/METHODS:One hundred three patients who underwent cochlear implantation between June 2020 and August 2021. INTERVENTIONS/METHODS:Intraoperative electrophysiologic monitoring (electrode impedances, neural response telemetry, and TIM measurement) and modified Stenver's view plain film radiographs. MAIN OUTCOME MEASURES/METHODS:Identification of tip foldover on both TIM and plain films. RESULTS:In total, 103 patients (117 ears) had both a TIM measurement and intraoperative X-ray available for review, including 68 adults and 35 children. One hundred patients (85%) received the Cochlear Slim Modiolar electrode. Tip foldovers were noted in three of 117 implants (2.5%). In all cases, TIM was able to detect the foldover, and the electrode arrays were reinserted with the patients still under anesthesia, with repeat X-ray demonstrating a normal configuration. Two other abnormal TIM patterns were identified. One was in a patient with an obstructed cochlea in whom only 10 electrodes could be inserted, the other was in a patient with a common cavity abnormality. One additional patient underwent electrode repositioning intraoperatively because of overinsertion. In this patient, the TIM appeared to be within normal limits, but the over-insertion was apparent on X-ray. Overall, the sensitivity and specificity of TIM measurements in detecting electrode tip foldover were both 100%. CONCLUSION/CONCLUSIONS:TIM measurements were able to accurately identify tip foldovers. More research is needed to define the adjunctive role of TIM as an intraoperative measure.
PMID: 36040040
ISSN: 1537-4505
CID: 5334992

Cochlear Implantation Outcomes in Patients With Retrocochlear Pathology: A Systematic Review and Pooled Analysis

Schlacter, Jamie A; Kay-Rivest, Emily; Nicholson, Joseph; Santacatterina, Michele; Zhang, Yan; Jethanamest, Daniel; Friedmann, David R; McMenomey, Sean O; Roland, J Thomas
OBJECTIVE:To review the current literature regarding cochlear implantation in patients with retrocochlear pathologies and extract speech perception scores between 6 months and 1 year after surgery. DATABASES REVIEWED/UNASSIGNED:PubMed/MEDLINE, Embase and Cochrane CENTRAL via Ovid, CINAHL Complete via Ebsco, and Web of Science. METHODS:The review was conducted according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Search strategies included keywords and subject headings to maximize retrieval and reflect cochlear implants and retrocochlear pathologies. Patients with previously resected vestibular schwannoma (VS) were excluded. RESULTS:There were 2,524 abstracts screened against inclusion criteria, and 53 studies were included, with individual data available for 171 adult patients. Pathologies included were either observed or irradiated VS (previously operated tumors were excluded) (n = 99, 57.9%), superficial siderosis (n = 39, 22.8%), neurosarcoidosis (n = 11, 6.4%), and previous central nervous system or skull base radiation (n = 22, 12.9%). Mean (standard deviation) postoperative consonant-nucleus-consonant (CNC) word scores were 45.4% (24.2) for observed VS, 44.4% (20.8) for irradiated VS, 43.6% (21.0) for superficial siderosis, 89.5% (3.0) for neurosarcoidosis, and 30.0% (30.2) in patients with previous central nervous system or skull base irradiation. Irradiated compared with observed VS had similar postoperative CNC word scores (effect size, 0.06; p = 0.71). Age, sex, maximal tumor dimension, and neurofibromatosis type 2 status did not significantly impact cochlear implant performance in patients with VS. Eighty-two percent of patients with reported device usage were daily users, and overall, 82% of cases benefitted from cochlear implantation. CONCLUSION/CONCLUSIONS:Cochlear implantation in patients with concomitant retrocochlear pathology generally results in improved speech discrimination scores sustained over time.
PMID: 36047686
ISSN: 1537-4505
CID: 5335012

Modern Hearing Preservation Outcomes After Vestibular Schwannoma Stereotactic Radiosurgery

Berger, Assaf; Alzate, Juan Diego; Bernstein, Kenneth; Mullen, Reed; McMenomey, Sean; Jethanemest, Daniel; Friedmann, David R; Smouha, Eric; Sulman, Erik P; Silverman, Joshua S; Roland, J Thomas; Golfinos, John G; Kondziolka, Douglas
BACKGROUND:For patients with vestibular schwannoma (VS), stereotactic radiosurgery (SRS) has proven effective in controlling tumor growth while hearing preservation remains a key goal. OBJECTIVE:To evaluate hearing outcomes in the modern era of cochlear dose restriction. METHODS:During the years 2013 to 2018, 353 patients underwent Gamma knife surgery for VS at our institution. We followed 175 patients with pre-SRS serviceable hearing (Gardner-Robertson Score, GR 1 and 2). Volumetric and dosimetry data were collected, including biological effective dose, integral doses of total and intracanalicular tumor components, and hearing outcomes. RESULTS:The mean age was 56 years, 74 patients (42%) had a baseline GR of 2, and the mean cochlear dose was 3.5 Gy. The time to serviceable hearing loss (GR 3-4) was 38 months (95% CI 26-46), with 77% and 62% hearing preservation in the first and second years, respectively. Patients optimal for best hearing outcomes were younger than 58 years with a baseline GR of 1, free canal space ≥0.041 cc (diameter of 4.5 mm), and mean cochlear dose <3.1 Gy. For such patients, hearing preservation rates were 92% by 12 months and 81% by 2 years, staying stable for >5 years post-SRS, significantly higher than the rest of the population. CONCLUSION/CONCLUSIONS:Hearing preservation after SRS for patients with VS with serviceable hearing is correlated to the specific baseline GR score (1 or 2), age, cochlear dose, and biological effective dose. Increased tumor-free canal space correlates with better outcomes. The most durable hearing preservation correlates with factors commonly associated with smaller tumors away from the cochlea.
PMID: 35973088
ISSN: 1524-4040
CID: 5299902

Fluorescence in situ hybridization and microbial community profiling analysis of explanted cochlear implants

Asfour, Leena; Smyth, Daniel; Whitchurch, Cynthia B; Cavaliere, Rosalia; Roland, J Thomas
BACKGROUND/UNASSIGNED:hybridization (FISH) and microbial community profiling (MCP) are methods of studying microbial environments of explanted devices that can provide information to reduce morbidity and costs of infected CIs. AIMS/OBJECTIVES/UNASSIGNED:To describe the results and clinical significance of bacterial analyses conducted on explanted CIs. MATERIAL AND METHODS/UNASSIGNED:Between 2013 and 2017, 12 explanted devices underwent microbiological analysis in addition to the manufacturer's device failure analysis. Patients' clinical history, infection status and outcome were reviewed and correlated with microbial analysis results. RESULTS/UNASSIGNED:From 2013 to 2017, 12 Cochlearâ„¢ devices from 11 patients underwent additional MCP or FISH analysis. Five devices were explanted due to suspected implant associated infection, and seven were explanted for other reasons. FISH analysis revealed biofilm presence on all infected devices, only partial correlation of cultures with biofilm composition and confirmation that biofilm formation occurs preferentially at particular device interfaces and geometries. MCP analysis presented challenges in data analysis inherent to its technique but correlated with cultures of infected devices and suggested a diverse microbial composition of explanted devices. CONCLUSIONS AND SIGNIFICANCE/UNASSIGNED:Microbial analysis of explanted devices can aid in further elucidating treatment approaches to infected CIs.
PMID: 35549817
ISSN: 1651-2251
CID: 5214642