Try a new search

Format these results:

Searched for:

in-biosketch:true

person:vainra01

Total Results:

54


Tale of 2 Orifices

Vainrib, Alan F; Loulmet, Didier F; Williams, Mathew R; Saric, Muhamed
PMID: 30636514
ISSN: 1942-0080
CID: 3594712

Minimizing Permanent Pacemaker Following Repositionable Self-Expanding Transcatheter Aortic Valve Replacement

Jilaihawi, Hasan; Zhao, Zhengang; Du, Run; Staniloae, Cezar; Saric, Muhamed; Neuburger, Peter J; Querijero, Michael; Vainrib, Alan; Hisamoto, Kazuhiro; Ibrahim, Homam; Collins, Tara; Clark, Emily; Pushkar, Illya; Bamira, Daniel; Benenstein, Ricardo; Tariq, Afnan; Williams, Mathew
OBJECTIVES/OBJECTIVE:This study sought to minimize the risk of permanent pacemaker implantation (PPMI) with contemporary repositionable self-expanding transcatheter aortic valve replacement (TAVR). BACKGROUND:Self-expanding TAVR traditionally carries a high risk of PPMI. Limited data exist on the use of the repositionable devices to minimize this risk. METHODS:At NYU Langone Health, 248 consecutive patients with severe aortic stenosis underwent TAVR under conscious sedation with repositionable self-expanding TAVR with a standard approach to device implantation. A detailed analysis of multiple factors contributing to PPMI was performed; this was used to generate an anatomically guided MInimizing Depth According to the membranous Septum (MIDAS) approach to device implantation, aiming for pre-release depth in relation to the noncoronary cusp of less than the length of the membranous septum (MS). RESULTS:Right bundle branch block, MS length, largest device size (Evolut 34 XL; Medtronic, Minneapolis, Minnesota), and implant depth > MS length predicted PPMI. On multivariate analysis, only implant depth > MS length (odds ratio: 8.04 [95% confidence interval: 2.58 to 25.04]; p < 0.001) and Evolut 34 XL (odds ratio: 4.96 [95% confidence interval: 1.68 to 14.63]; p = 0.004) were independent predictors of PPMI. The MIDAS approach was applied prospectively to a consecutive series of 100 patients, with operators aiming to position the device at a depth of < MS length whenever possible; this reduced the new PPMI rate from 9.7% (24 of 248) in the standard cohort to 3.0% (p = 0.035), and the rate of new left bundle branch block from 25.8% to 9% (p < 0.001). CONCLUSIONS:Using a patient-specific MIDAS approach to device implantation, repositionable self-expanding TAVR achieved very low and predictable rates of PPMI which are significantly lower than previously reported with self-expanding TAVR.
PMID: 31473236
ISSN: 1876-7605
CID: 4066832

Photorealistic imaging of left atrial appendage occlusion/exclusion

Vainrib, Alan F; Bamira, Daniel; Aizer, Anthony; Chinitz, Larry A; Loulmet, Didier; Benenstein, Ricardo J; Saric, Muhamed
Recent improvements in 3D TEE post processing rendering techniques referred to as TrueVue (Philips Medical Systems, Andover, MA, USA). It allows for novel photorealistic imaging of cardiac structures including left atrial appendage (LAA) and its closure devices. Here we present TrueVue images of the LAA prior to and after LAA exclusion/occlusion using various percutaneous and surgical techniques. TrueVue may improve delineation of LAA anatomy prior to occlusion as well as visualization of occluder device position within the LAA.
PMID: 31385344
ISSN: 1540-8175
CID: 4033092

Klippel-Feil syndrome: A very unusual cause of severe aortic regurgitation visualized by multimodality imaging [Case Report]

Ahluwalia, Monica; Sehgal, Sankalp; Vainrib, Alan F; Applebaum, Robert; Latson, Larry; Williams, Mathew R; Saric, Muhamed
A 51-year-old man with Klippel-Feil syndrome (KFS) and immunodeficiency syndrome, status postintravenous immunoglobulin therapy, presented with shortness of breath. He was found to have severe aortic regurgitation in the setting of a trileaflet aortic valve with thickened leaflets and mild prolapse of the right coronary cusp with left ventricular dilation and borderline left ventricular ejection fraction. Although various cardiac anomalies have been described in KPS, otherwise unexplained severe aortic regurgitation has not been previously reported to the best of our knowledge. The patient underwent an uncomplicated surgical aortic valve replacement with a 25-mm Medtronic Avalus pericardial tissue valve resulting in symptomatic improvement. Intra-operative management and transesophageal echocardiography can be particularly challenging in KFS patients. We describe the first reported case of severe aortic regurgitation in KPS, review the cardiac anomalies associated with the syndrome, and highlight the clinical challenges in intra-operative management of these patients.
PMID: 31246314
ISSN: 1540-8175
CID: 3954352

Left Atrial Occlusion Device Implantation: the Role of the Echocardiographer

Altszuler, David; Vainrib, Alan F; Bamira, Daniel G; Benenstein, Ricardo J; Aizer, Anthony; Chinitz, Larry A; Saric, Muhamed
PURPOSE OF REVIEW/OBJECTIVE:Atrial fibrillation is the most common arrhythmia worldwide and is a major risk factor for embolic stroke. For patients with atrial fibrillation who are unable to tolerate systemic anticoagulation, left atrial appendage (LAA) occlusion has been shown to mitigate stroke risk. In this article, we describe the vital role of the echocardiographer in intraprocedural guidance of percutaneous LAA occlusion procedures as well as in the pre- and post-procedure assessment of these patients. RECENT FINDINGS/RESULTS:A few percutaneously delivered devices for LAA exclusion from the systemic circulation are available in contemporary practice. These devices employ an either exclusive endocardial LAA occlusion approach, such as the Watchman (Boston Scientific, Maple Grove, MN) and Amulet (St. Jude Medical, Minneapolis, MN), or both an endocardial and pericardial (epicardial) approach such as the Lariat procedure (SentreHEART, Palo Alto, CA). Two- and three-dimension transesophageal echocardiography is critical for patient selection, procedure planning, procedural guidance, and ensuring satisfactory immediate as well as long-term LAA occlusion/exclusion efficacy. This review will provide an overview of the role of the echocardiographer in all aspects of LAA occlusion/exclusion procedures for the most commonly used commercially available devices in current practice.
PMID: 31183616
ISSN: 1534-3170
CID: 3929942

Echocardiographic Guidance of the Novel WaveCrest Left Atrial Appendage Occlusion Device

Vainrib, Alan F; Bamira, Daniel; Benenstein, Ricardo J; Aizer, Anthony; Chinitz, Larry A; Saric, Muhamed
PMCID:6302034
PMID: 30582095
ISSN: 2468-6441
CID: 3560082

Multimodality Imaging of a Rare Case of Bronchogenic Cyst Presenting as New-Onset Atrial Fibrillation in a Young Woman

Liu, Qi; Vainrib, Alan F; Aizer, Anthony; Dodson, John A; Reynolds, Harmony R; Cerfolio, Robert J; Saric, Muhamed
PMCID:6302153
PMID: 30582085
ISSN: 2468-6441
CID: 3560072

Outcomes after transcatheter aortic valve replacement in patients with low versus high gradient severe aortic stenosis in the setting of preserved left ventricular ejection fraction

Shah, Binita; McDonald, Daniel; Paone, Darien; Redel-Traub, Gabriel; Jangda, Umair; Guo, Yu; Saric, Muhamed; Donnino, Robert; Staniloae, Cezar; Robin, Tonya; Benenstein, Ricardo; Vainrib, Alan; Williams, Mathew R
BACKGROUND:Transcatheter aortic valve replacement (TAVR) for low gradient (LG) severe aortic stenosis (AS) with preserved left ventricular ejection fraction (LVEF) remains an area of clinical uncertainty. METHODS:Retrospective review identified 422 patients who underwent TAVR between September 4, 2014 and July 1, 2016. Procedural indication other than severe AS (n = 22) or LVEF <50% (n = 98) were excluded. Outcomes were defined by valve academic research consortium two criteria when applicable and compared between LG (peak velocity <4.0 m/s and mean gradient <40 mmHg; n = 73) and high gradient (HG) (n = 229) groups. The LG group was further categorized as low stroke volume index (SVI) (n = 41) or normal SVI (n = 32). Median follow-up was 747 days [interquartile range 220-1013]. RESULTS: = 0.39). CONCLUSION/CONCLUSIONS:Patients with preserved LVEF undergoing TAVR for severe AS with LG, including LG with low SVI, have no significant difference in adverse outcomes when compared to patients with HG.
PMID: 30203608
ISSN: 1540-8183
CID: 3278212

Multimodality imaging of scimitar syndrome in adults: A report of four cases [Case Report]

Ngai, Calvin; Freedberg, Robin S; Latson, Larry; Argilla, Michael; Benenstein, Ricardo J; Vainrib, Alan F; Donnino, Robert; Saric, Muhamed
Partial anomalous pulmonary venous return (PAPVR) comprises a group of congenital cardiovascular anomalies associated with pulmonary venous flow directly or indirectly into the right atrium. Scimitar syndrome is a variant of PAPVR in which the right lung is drained by right pulmonary veins connected anomalously to the inferior vena cava. Surgery is the definitive treatment for scimitar syndrome. However, it is not always necessary as many patients are asymptomatic, have small left-to-right shunts, and enjoy a normal life expectancy without surgery. We report multimodality imaging in four adults with scimitar syndrome and the implications for management of this rare syndrome.
PMID: 30136740
ISSN: 1540-8175
CID: 3246482

Left Atrial Appendage Occlusion/Exclusion: Procedural Image Guidance with Transesophageal Echocardiography

Vainrib, Alan F; Harb, Serge C; Jaber, Wael; Benenstein, Ricardo J; Aizer, Anthony; Chinitz, Larry A; Saric, Muhamed
Atrial fibrillation is the most common arrhythmia worldwide and is a major risk factor for embolic stroke. In this article, the authors describe the crucial role of two- and three-dimensional transesophageal echocardiography in the pre- and postprocedural assessment and intraprocedural guidance of percutaneous left atrial appendage (LAA) occlusion procedures. Although recent advances have been made in the field of systemic anticoagulation with the novel oral anticoagulants, these medications come with a significant risk for bleeding and are contraindicated in many patients. Because thromboembolism in atrial fibrillation typically arises from thrombi originating in the LAA, surgical and percutaneous LAA exclusion/occlusion techniques have been devised as alternatives to systemic anticoagulation. Currently, surgical LAA exclusion is typically performed as an adjunct to other cardiac surgical procedures, which limits the number of eligible patients. Recently, several percutaneously delivered devices for LAA exclusion from the systemic circulation have been developed, some of which have been shown in clinical trials to reduce the risk for thromboembolism. These devices use an either purely endocardial LAA occlusion approach, such as the Watchman and Amulet procedures, or both an endocardial and a pericardial (epicardial) approach, such as the Lariat procedure. In the Watchman and Amulet procedures, a transseptally delivered structure composed of nitinol is placed in the LAA orifice, thereby excluding the LAA from the systemic circulation. In the Lariat procedure, a magnet link is created between a transseptally delivered endocardial wire and epicardially delivered pericardial wire, followed by epicardial suture ligation of the LAA.
PMID: 29158017
ISSN: 1097-6795
CID: 2792412