Try a new search

Format these results:

Searched for:

in-biosketch:true

person:neubup01

Total Results:

74


Surgical Excision of a Left Atrial Myxoma During the Second Trimester of Pregnancy

Harrison, John-Henry N; Arnolds, David E; Banayan, Jennifer M; Rana, Sarosh; Schnettler, William T; Neuburger, Peter J
PMID: 31818529
ISSN: 1532-8422
CID: 4234192

Anesthesiologists Can Add Value in Transcatheter Aortic Valve Replacement by Performing Transthoracic Echocardiography [Editorial]

Tanaka, Christopher Y; Hartman, Kaitlyn M; Patel, Prakash A; Neuburger, Peter J
PMID: 31395411
ISSN: 1532-8422
CID: 4033532

Preprocedural P2Y12 inhibition and decrease in platelet count following transcatheter aortic valve replacement

Ibrahim, Homam; Vapheas, Eleonora; Shah, Binita; AlKhalil, Ahmad; Querijero, Michael; Jilaihawi, Hasan; Neuburger, Peter; Staniloae, Cezar; Williams, Mathew R
BACKGROUND:inhibition prevents postprocedural thrombocytopenia is uncertain. METHODS: platelets/μL; n = 14), or without baseline platelet count (n = 4) were excluded. The primary outcome was proportion of patients who developed >20% decrease in platelet count from baseline to day 1 post-TAVR. RESULTS:inhibition developed thrombocytopenia on day 1 post-TAVR (25.5% vs. 36.4%, p = .1). CONCLUSION/CONCLUSIONS:inhibition prior to TAVR were less likely to demonstrate a decrease in platelet count after TAVR. Prospective studies to further understand the clinical implication of these findings are warranted.
PMID: 31062487
ISSN: 1522-726x
CID: 3928742

Thinking Outside the Heart: An Innovative Approach of Speckle Tracking With Transesophageal Echocardiography [Editorial]

Rong, Lisa Q; Neuburger, Peter J; De Paulis, Stefano; Kim, Jiwon
PMID: 31402241
ISSN: 1532-8422
CID: 4041742

Minimizing Permanent Pacemaker Following Repositionable Self-Expanding Transcatheter Aortic Valve Replacement

Jilaihawi, Hasan; Zhao, Zhengang; Du, Run; Staniloae, Cezar; Saric, Muhamed; Neuburger, Peter J; Querijero, Michael; Vainrib, Alan; Hisamoto, Kazuhiro; Ibrahim, Homam; Collins, Tara; Clark, Emily; Pushkar, Illya; Bamira, Daniel; Benenstein, Ricardo; Tariq, Afnan; Williams, Mathew
OBJECTIVES/OBJECTIVE:This study sought to minimize the risk of permanent pacemaker implantation (PPMI) with contemporary repositionable self-expanding transcatheter aortic valve replacement (TAVR). BACKGROUND:Self-expanding TAVR traditionally carries a high risk of PPMI. Limited data exist on the use of the repositionable devices to minimize this risk. METHODS:At NYU Langone Health, 248 consecutive patients with severe aortic stenosis underwent TAVR under conscious sedation with repositionable self-expanding TAVR with a standard approach to device implantation. A detailed analysis of multiple factors contributing to PPMI was performed; this was used to generate an anatomically guided MInimizing Depth According to the membranous Septum (MIDAS) approach to device implantation, aiming for pre-release depth in relation to the noncoronary cusp of less than the length of the membranous septum (MS). RESULTS:Right bundle branch block, MS length, largest device size (Evolut 34 XL; Medtronic, Minneapolis, Minnesota), and implant depth > MS length predicted PPMI. On multivariate analysis, only implant depth > MS length (odds ratio: 8.04 [95% confidence interval: 2.58 to 25.04]; p < 0.001) and Evolut 34 XL (odds ratio: 4.96 [95% confidence interval: 1.68 to 14.63]; p = 0.004) were independent predictors of PPMI. The MIDAS approach was applied prospectively to a consecutive series of 100 patients, with operators aiming to position the device at a depth of < MS length whenever possible; this reduced the new PPMI rate from 9.7% (24 of 248) in the standard cohort to 3.0% (p = 0.035), and the rate of new left bundle branch block from 25.8% to 9% (p < 0.001). CONCLUSIONS:Using a patient-specific MIDAS approach to device implantation, repositionable self-expanding TAVR achieved very low and predictable rates of PPMI which are significantly lower than previously reported with self-expanding TAVR.
PMID: 31473236
ISSN: 1876-7605
CID: 4066832

Can complex mitral valve repair be performed with robotics? An institution's experience utilizing a dedicated team approach in 500 patients

Loulmet, Didier F; Ranganath, Neel K; Neuburger, Peter J; Nampiaparampil, Robert G; Galloway, Aubrey C; Grossi, Eugene A
OBJECTIVES/OBJECTIVE:The full potential of robotics has not been achieved in terms of addressing the most challenging mitral valve (MV) cases. We outline our technique and report our early results with totally endoscopic robotic MV repair in a wide range of pathologies. METHODS:From May 2011 to August 2017, a dedicated team attempted totally endoscopic robotic MV repair in 500 MV regurgitation patients. Repair complexity was scored in 3 categories. We analysed our sequential case experience by quartiles. RESULTS:Patient mean age was 60.8 years (range 18-88). Aetiologies included: degenerative 382 (76.4%), functional 37 (7.4%), inflammatory 22 (4.4%) and others 59 (11.8%). Mitral annular calcification was present in 64 (12.8%) cases. Simple MV repair (annuloplasty alone or with 1 leaflet segment repair) was performed in 240 (48%) patients, complex (repair involving more than 1 segment on the same leaflet) in 140 (28%) patients and most complex (bileaflet repair or mitral annular calcification excision with atrioventricular groove repair) in 120 (24%) patients. Concomitant procedures included: left appendage closure (94.8%), patent foramen ovale/atrial septal defect (PFO/ASD) closure (19.6%), cryoablation (19.4%), tricuspid repair (6.2%) or hybrid percutaneous coronary revascularization (7.8%). The overall repair rate was 99.4%, with 0.6% early mortality and 1.2% stroke rate (0.2% permanent neurological deficit). Case complexity increased with our experience. Despite an increase in aortic occlusion and perfusion times (median 86.5 and 125 min) and a slight decrease in operating room extubation rate (overall 64%), length of hospital stay (median 4 days) and 30-day readmission rate (overall 3.6%) were not affected by the progressive inclusion of more complex cases. CONCLUSIONS:Totally endoscopic robotic MV repair performed by a dedicated team allows one to address the entire spectrum of pathological complexity and provides consistent results.
PMID: 30753381
ISSN: 1873-734x
CID: 3656212

In Pursuit of a Unicorn: Does the Ideal Parameter for Grading of Aortic Stenosis During Intraoperative Transesophageal Echocardiography Exist? [Editorial]

Pospishil, Liliya; Patel, Prakash A; Neuburger, Peter J
PMID: 31138469
ISSN: 1532-8422
CID: 3921462

Operational and Institutional Recommendations and Requirements for TAVR: A Review of Expert Consensus and the Impact on Health Care Policy

Neuburger, Peter J; Luria, Brent J; Rong, Lisa Q; Sin, Danielle N; Patel, Prakash A; Williams, Mathew R
When transcatheter aortic valve replacement (TAVR) was first approved for use in the United States in 2012, multiple leading surgical and cardiology societies were tasked with creating recommendations and requirements for operators and institutions starting and maintaining TAVR programs. Creation of this consensus document was challenging due to limited experience with this new technology, and a lack of robust centralized data that could be used to validate outcome measures and create benchmarks for self-assessment and improvement. Despite these limitations, this document provided government agencies a framework for regulation that ultimately determined requirements for Medicare payment for TAVR and therefore greatly determined how and where care was delivered for patients with aortic stenosis. After the proliferation of TAVR institutions throughout the US and with data from more than 100,000 cases in the STS/ACC Transcatheter Valve Therapies TM Registry, leaders of the same societies reconvened in 2018 to update their consensus document. The new recommendations include suggested personnel, facilities, training, and assessment of outcomes and competencies required to run a safe and efficient TAVR program. This article seeks to detail the changes from the original consensus document with a particular focus on issues relevant to cardiac anesthesiologists as well as important healthcare policy ramifications for patients and providers in the United States.
PMID: 30852090
ISSN: 1532-8422
CID: 3732852

Ongoing Obstacles for Universal Use of Sedation for Transfemoral Transcatheter Aortic Valve Replacement [Editorial]

Patel, Prakash A; Neuburger, Peter J
PMID: 30217588
ISSN: 1532-8422
CID: 3278472

Intraoperative Measurement of the Tricuspid Annulus: To 3D or not to 3D? [Editorial]

Chacon, M Megan; Neuburger, Peter J
PMID: 30122609
ISSN: 1532-8422
CID: 3246282