Try a new search

Format these results:

Searched for:

in-biosketch:true

person:jankel01

Total Results:

98


Lesion Sequence and Catheter Spatial Stability Affect Lesion Quality Markers in Atrial Fibrillation Ablation

Jankelson, Lior; Dai, Matthew; Aizer, Anthony; Bernstein, Scott; Park, David S; Holmes, Douglas; Chinitz, Larry A; Barbhaiya, Chirag
OBJECTIVES/OBJECTIVE:This study sought to analyze high-frequency catheter excursion in relation to lesion quality markers in 20 consecutive patients undergoing first-time radiofrequency (RF) ablation for paroxysmal atrial fibrillation (AF). BACKGROUND:Ablation therapy for AF requires the delivery of durable lesions. The extent to which lesion sequence, catheter spatial stability, and anatomic location influence lesion formation during RF ablation of AF is not well understood. METHODS:Three-dimensional spatial excursion of the ablation catheter sampled at 60 Hz during pre-specified pairs of RF lesions was extracted from the CARTO3 System (Biosense Webster Inc., Irvine, California) and analyzed by using custom-developed MATLAB software (MathWorks, Natick, Massachusetts) to define precise catheter spatial stability during RF ablation. Ablation parameters including bipolar electrogram amplitude reduction, impedance decline and transmurality-associated unipolar electrogram (TUE) as evidence of lesion transmurality during lesion placement were recorded and analyzed. RESULTS:We collected 437,760 position data points during lesion placement. Ablation catheter spatial stability and lesion formation parameters varied considerably by anatomic location. Lesions placed immediately had similar bipolar electrogram amplitude reduction, smaller impedance decline, but higher likelihood of achieving TUE compared to delayed lesions. Greater catheter spatial stability correlated with lesser impedance decline. CONCLUSIONS:Lesion sequence, ablation catheter spatial stability, and anatomic location are important modifiers of RF lesion formation. Lesions placed immediately are more likely to exhibit TUE. Greater ablation catheter stability is associated with lesser impedance decline but greater likelihood of TUE.
PMID: 33516716
ISSN: 2405-5018
CID: 4775692

QTc Prolongation Risk Evaluation in Female COVID-19 Patients Undergoing Chloroquine and Hydroxychloroquine With/Without Azithromycin Treatment

Grewal, Sarah; Jankelson, Lior; van den Broek, Marcel P H; Cour, Martin; Bachmann, Gloria; Kostis, John B; Misra, Kamana
Women have higher risk for developing TdP in response to ventricular repolarization prolonging drugs. Hundreds of trials are administering chloroquine and hydroxychloroquine with/without azithromycin to COVID-19 patients. While an overall prolonged QTc has been reported in COVID-19 patients undergoing these treatments, the question on even higher QTc elevation risk in thousands of female COVID-19 patients undergoing these treatments remains unanswered. We therefore explore data reported and shared with us to evaluate safety and efficacy of antimalaria pharmacotherapies in female COVID-19 patients. Although we observed longer mean QTc intervals in female patients in 2 of the 3 cohorts reviewed, the sex disproportionality in COVID-19 hospitalizations precludes a clear sex mediated QTc interval elevation risk association in the female COVID-19 patients undergoing acute treatment regimens. Adoption of study designs that include observation of sex mediated differential triggering of cardiac electrical activity by these drugs is warranted.
PMCID:7498717
PMID: 33102533
ISSN: 2297-055x
CID: 5093062

Ablation in Atrial Fibrillation with Ventricular Pacing Results in Similar Spatial Catheter Stability as Compared to Ablation in Sinus Rhythm with Atrial Pacing

Dai, Matthew; Barbhaiya, Chirag; Aizer, Anthony; Hyde, Jonathan; Kogan, Edward; Holmes, Douglas; Bernstein, Scott; Spinelli, Michael; S Park, David; A Chinitz, Larry; Jankelson, Lior
Background/UNASSIGNED:Improved catheter stability is associated with decreased arrhythmia recurrence after atrial fibrillation (AF) ablation. Recently, atrial voltage mapping in AF was demonstrated to correlate better with scar as compared to mapping in sinus rhythm (SR). However, it is unknown whether ablation of persistent AF in sinus rhythm with atrial pacing or in atrial fibrillation with ventricular pacing results in differences in catheter stability or arrhythmia recurrence. Methods/UNASSIGNED:We analyzed 53 consecutive patients undergoing first-time persistent AF ablation with pulmonary vein and posterior wall isolation: 27 were cardioverted, mapped, and ablated in sinus rhythm with atrial pacing, and 26 were mapped and ablated in AF with ventricular pacing. Ablation data was extracted from the mapping system and analyzed using custom MATLAB software to determine high-frequency (60Hz) catheter excursion as a novel metric for catheter spatial stability. Results/UNASSIGNED:There was no difference in catheter stability as assessed by maximal catheter excursion, mean catheter excursion, or contact force variability between the atrial-paced and ventricular-paced patients. Ventricular-paced patients had significantly greater mean contact force as compared to atrial-paced patients. Contact-force variability demonstrated poor correlation with catheter excursion. One year arrhythmia-free survival was similar between the atrial paced and ventricular paced patients. Conclusions/UNASSIGNED:For patients with persistent AF, ablation in AF with ventricular pacing results in similar catheter stability and arrhythmia recurrence as compared to cardioversion and ablation in sinus rhythm with atrial pacing. Given the improved fidelity of mapping in AF, mapping and ablating during AF with ventricular pacing may be preferred.
PMCID:8691334
PMID: 34950311
ISSN: 1941-6911
CID: 5093082

Inappropriate ICD Shock as a Result of TASER Discharge [Case Report]

Barbhaiya, Chirag R; Moskowitz, Craig; Duraiswami, Harish; Jankelson, Lior; Knotts, Robert J; Bernstein, Scott; Park, David; Holmes, Douglas; Aizer, Anthony; Chinitz, Larry A
Conducted energy weapon (commonly known as TASER) discharge in patients with implantable cardioverter-defibrillators is known to cause electromagnetic interference and inappropriate ventricular fibrillation sensing without delivery of implantable cardioverter-defibrillators therapy during conducted energy weapon application. We report the first known case of conducted energy weapon discharge resulting in inappropriate implantable cardioverter-defibrillators therapy. (Level of Difficulty: Beginner.).
PMCID:8311712
PMID: 34317440
ISSN: 2666-0849
CID: 4949472

Pseudopolymorphic Wide Complex Tachycardia in a Child With Long QT Syndrome [Case Report]

Cerrone, Marina; Magnani, Silvia; Borneman, Linda; Cecchin, Frank; Tan, Reina; Fowler, Steven J; Chinitz, Larry; Jankelson, Lior
Implantable loop recorders (ILRs) can be a valuable tool in monitoring patients with inherited arrhythmia. This paper reports on a family with long QT syndrome (type 2 [LQT2]) in which a pseudopolymorphic wide complex tachycardia detected by ILR was ultimately diagnosed as a supraventricular aberrant rhythm, facilitated by noncompliance with beta-blocker therapy. (Level of Difficulty: Intermediate.).
PMCID:8298547
PMID: 34317300
ISSN: 2666-0849
CID: 4949452

Reply: Electrical Weapons and Electrophysiology

Barbhaiya, Chirag R; Moskowitz, Craig; Duraiswami, Harish; Jankelson, Lior; Knotts, Robert J; Bernstein, Scott; Park, David; Holmes, Douglas; Aizer, Anthony; Chinitz, Larry A
PMCID:8299239
PMID: 34317106
ISSN: 2666-0849
CID: 4949432

Multiple Procedure Outcomes for Non-Paroxysmal Atrial Fibrillation: Left Atrial Posterior Wall Isolation versus Stepwise Ablation

Barbhaiya, Chirag R; Knotts, Robert J; Beccarino, Nicholas; Vargas-Pelaez, Alvaro F; Jankelson, Lior; Bernstein, Scott; Park, David; Holmes, Douglas; Aizer, Anthony; Chinitz, Larry A
OBJECTIVE:To compare multiple-procedure catheter ablation outcomes of a stepwise approach versus left atrial posterior wall isolation (LA PWI) in patients undergoing non-paroxysmal atrial fibrillation (NPAF) ablation. BACKGROUND:Unfavorable outcomes for stepwise ablation of NPAF in large clinical trials may be attributable to pro-arrhythmic effects of incomplete ablation lines. It is unknown if a more extensive initial ablation strategy results in improved outcomes following multiple ablation procedures. METHODS:222 consecutive patients with NPAF underwent first-time ablation using a contact-force sensing ablation catheter utilizing either a stepwise (Group 1, n=111) or LA PWI (Group 2, n=111) approach. The duration of follow-up was 36 months. The primary endpoint was freedom from atrial arrhythmia >30s. Secondary endpoints were freedom from persistent arrhythmia, repeat ablation, and recurrent arrhythmia after repeat ablation. RESULTS:There was similar freedom from atrial arrhythmias after index ablation for both stepwise and LA PWI groups at 36 months (60% vs. 69%, p=0.1). The stepwise group was more likely to present with persistent recurrent arrhythmia (29% vs 14%, p=0.005) and more likely to undergo second catheter ablation (32% vs. 12%, p<0.001) compared to LA PWI patients. Recurrent arrhythmia after repeat ablation was more likely in the stepwise group compared to the LA PWI group (15% vs 4%, p=0.003). CONCLUSIONS:Compared to a stepwise approach, LA PWI for patients with NPAF resulted in a similar incidence of any atrial arrhythmia, lower incidence of persistent arrhythmia, and fewer repeat ablations. Results for repeat ablation were not improved with a more extensive initial approach. This article is protected by copyright. All rights reserved.
PMID: 33022816
ISSN: 1540-8167
CID: 4626822

Response to: Do not yet abandon cephalic vein access for multiple leads in ICD implantation [Letter]

Barbhaiya, Chirag R; Niazi, Osama; Jankelson, Lior; Bernstein, Scott; Park, David; Holmes, Douglas; Aizer, Anthony; Chinitz, Larry A
PMID: 32789905
ISSN: 1540-8167
CID: 4556572

The case for quinidine: Management of electrical storm in refractory ventricular fibrillation [Case Report]

Pinnelas, Rebecca; Friedman, Julie; Gidea, Claudia; Yuriditsky, Eugene; Chinitz, Larry; Cerrone, Marina; Jankelson, Lior
PMCID:7360984
PMID: 32695580
ISSN: 2214-0271
CID: 4532352

Comparison of the Effect of Atrial Fibrillation Detection Algorithms in Patients With Cryptogenic Stroke Using Implantable Loop Recorders

Chorin, Ehud; Peterson, Connor; Kogan, Edward; Barbhaiya, Chirag; Aizer, Anthony; Holmes, Douglas; Bernstein, Scott; Schole, Michael; Duraiswami, Harish; Spinelli, Michael; Park, David; Chinitz, Larry; Jankelson, Lior
Occult atrial fibrillation (AF) can be the underlying cause for cryptogenic stroke (CS). Implantable loop recorders (ILRs) have become an important tool for long-term arrhythmia monitoring in CS patients. Office-based ILR implantation by nonelectrophysiologist physicians is increasingly common. To report the real world diagnostic yield and accuracy of remote ILR monitoring in high risk CS patients, we retrospectively analyzed 145 consecutive patients with CS who underwent ILR implantation between October 2014 and October 2018 at New York University Langone Health. A certified device technician and an electrophysiologist adjudicated all transmissions. The yield and accuracy of Reveal LINQ Intra Cardiac Monitor (ICM), a fourth generation device, was compared to that of TruRhythm Detection algorithm (fifth generation device). AF was diagnosed in 17 patients (12%) over a mean follow-up of 28 ± 12 months. The median time to diagnosis was 7.4 ± 21.3 months. A total of 1,637 remote transmissions (scheduled- and auto-triggered alerts: 756; patient-triggered: 881) were adjudicated. The positive predictive value for AF episodes in the scheduled interrogations increased from 4% in the Reveal LINQ ICM to 16% in the TruRhythm LINQ. Of 881 patient-triggered transmissions, none were found to be true positive. In the Reveal LINQ ICM, for scheduled transmissions, primary causes of false positive (FP) were atrial ventricular premature complexes (80%). In the TruRhythm LINQ, for scheduled transmissions, primary cause of FP were T-wave over-sensing (87%). In conclusion, the real world diagnostic yield of ILR for patients with CS remains suboptimal, with at least 84% of AF alerts being FP. Patient-riggered events did not correlate with arrhythmia and the necessity of patient triggering in this population should be questioned. Expert interpretation of recordings is critical to assure accurate diagnosis.
PMID: 32600783
ISSN: 1879-1913
CID: 4504002