Early ICD Lead Failure in Defibrillator Systems with Multiple Leads Via Cephalic Access
Barbhaiya, Chirag R; Niazi, Osama; Bostrom, Jack; Patil, Sachi; Jankelson, Lior; Bernstein, Scott; Park, David; Holmes, Douglas; Aizer, Anthony; Chinitz, Larry A
INTRODUCTION/BACKGROUND:Implantable cardioverter defibrillators (ICDs) are proven to prevent sudden death in patients at elevated risk for sustained ventricular tachycardia or fibrillation. Complications related to ICD failure can stem from lead dysfunction, manufacturing defects, patient characteristics or implantation technique. We conducted a review of all ICD leads implanted at our center from 2011-2017 to determine risk factors for premature lead failure. METHODS:We conducted a retrospective review of patients of all ICD leads implanted from December 2011 to June 2017 at our institution. A total of 660 patients (Biotronik Linox S/SD, n = 281; Sprint Quatro, n = 207; Durata, n = 121; Endotak, n = 51) underwent ICD implantations. Patient and lead characteristics, procedural outcomes and complications were recorded. Lead failure was defined per Heart Rhythm Society lead-management consensus as a lack of procedural or clinical success, thus requiring an extraction of the lead. Patient and lead outcomes were recorded and variables associated with lead failure were assessed by the Kaplan-Meier method. RESULTS:Overall failure rate was similar for all leads: Linox S/SD - 0.29%/year; Sprint Quattro - 0.21%/year, Durata - 0.39%/year and Endotak Reliance - 0.0% (p=0.769). No difference was found in overall survival when comparing all ICD manufacturers during the study period. Subgroup analysis revealed the risk of premature lead failure was particularly pronounced in multi-lead ICD systems implanted via cephalic access (p<0.001). The estimated failure rate of Linox leads implanted via cephalic access in multi-lead systems was 19%/year. The estimated failure rate of non-Linox leads implanted via cephalic access in multi-lead systems was 11%/year. Neither age, nor gender were risk factors for lead failure in the Linox, or non-Linox cohorts. CONCLUSION/CONCLUSIONS:All analyzed ICD leads were found to have a similar overall risk of premature failure. ICD lead implantation via cephalic access in multilead ICD systems may be a previously unidentified risk factor for premature ICD lead failure, although these findings require further validation. This article is protected by copyright. All rights reserved.
PMID: 32356380
ISSN: 1540-8167
CID: 4412892
Direct autotransfusion following emergency pericardiocentesis in patients undergoing cardiac electrophysiology procedures
Barbhaiya, Chirag R; Guandalini, Gustavo S; Jankelson, Lior; Park, David; Bernstein, Scott; Holmes, Douglas; Aizer, Anthony; Chinitz, Larry
INTRODUCTION/BACKGROUND:Acute hemopericardium during cardiac electrophysiology (EP) procedures may result in significant blood loss and is the most common cause of procedure related death. Matched allogeneic blood is often not immediately available. The feasibility and safety of direct autotransfusion in cardiac electrophysiology patients requiring emergency pericardiocentesis is unknown. METHODS:We retrospectively analyzed records of patients undergoing EP procedures at a single, tertiary care medical center who had procedure-related acute hemopericardium requiring emergency pericardiocentesis during a three-year period. Procedure details, transfusion volumes, and clinical outcomes of patients who received direct autotransfusion of aspirated pericardial blood via a femoral venous sheath were compared to those of patients who did not receive direct autotransfusion. RESULTS:During the study period, 10 patients received direct autotransfusion (group 1) and outcomes were compared with those of 14 control patients who did not receive direct autotransfusion (group 2). Volume of aspirated pericardial blood was similar in groups 1 and 2 (1.6±0.7 L vs. 1.3±1.0 L, respectively; p=0.52). Amongst patients with aspirated volumes < 1L, group 1 patients (n=4) were less likely than group 2 patients (n=8) to require allotransfusion (0% vs. 75%, p=0.02). Amongst patients with aspirated volume ≥ 1L, group 1 patients (n=6) required fewer units of red cell allotransfusion than group 2 patients (n=6) (1.5±0.8u vs. 4.3±2.0u, p=0.01). No procedural complications related to direct autotransfusion occurred. CONCLUSIONS:Direct autotransfusion following emergency pericardiocentesis during electrophysiology procedures requiring systemic anticoagulation is feasible and safe. Utilization of direct autotransfusion may eliminate or reduce the need for allotransfusion. This article is protected by copyright. All rights reserved.
PMID: 32243641
ISSN: 1540-8167
CID: 4370572
Esophageal Temperature Dynamics During High Power Short Duration Posterior Wall Ablation
Barbhaiya, Chirag R; Kogan, Edward V; Jankelson, Lior; Knotts, Robert J; Spinelli, Michael; Bernstein, Scott; Park, David; Aizer, Anthony; Chinitz, Larry A; Holmes, Douglas
BACKGROUND:Increased peak luminal esophageal temperature (LET) is associated with increased risk of esophageal injury following left atrial posterior wall (LAPW) ablation. The magnitude, distribution, and risk factors of LET increase with high power short duration (HPSD) LAPW ablation are not well understood. OBJECTIVE:We aimed to describe the spatial and temporal characteristics of LET changes associated with HPSD LAPW RFA. METHODS:LET was sampled at 20Hz using a 12-point esophageal temperature monitor (CIRCA S-CATH, Circa Scientific, Inc.) in 16 patients undergoing LAPW ablation. Esophageal temperature sensor position and lesion locations were recorded using an electroanatomic mapping system with fluoroscopic integration (CARTO 3, CARTOUNIVU, Biosense Webster, Inc). Point-by-point LAPW ablation was performed at 50W for 6s. The first 20 LAPW lesions were individually analyzed in each patient. RESULTS:LET increase ≥4°C (8 lesions: Max LET 5.8°C), 2-4°C (34 lesions), and 1-2°C (58 lesions) occurred at 9±2 mm, 8±2 mm, and 13±2mm from sensors, respectively. Lesions placed >20mm from a temperature sensor did not result in an LET increase ≥2°C. Temperature resolution to within 1°C of baseline occurred at ∼60s after cessation of RF. Consecutive lesions resulting in additive heating of at least 1°C occurred in 17 lesion pairs with an inter-lesion distance of 9±4mm and inter-lesion time of 21±4s. CONCLUSION/CONCLUSIONS:HPSD LAPW ablation can result in severe esophageal temperature increases. Significant LET increase will be undetected when lesions are >20mm away from a temperature sensor. Additive LET increase was observed with consecutive lesions placed less than 20mm apart within 60s.
PMID: 31978595
ISSN: 1556-3871
CID: 4273622
Pseudopolymorphic Wide Complex Tachycardia in a Child With Long QT Syndrome [Case Report]
Cerrone, Marina; Magnani, Silvia; Borneman, Linda; Cecchin, Frank; Tan, Reina; Fowler, Steven J; Chinitz, Larry; Jankelson, Lior
Implantable loop recorders (ILRs) can be a valuable tool in monitoring patients with inherited arrhythmia. This paper reports on a family with long QT syndrome (type 2 [LQT2]) in which a pseudopolymorphic wide complex tachycardia detected by ILR was ultimately diagnosed as a supraventricular aberrant rhythm, facilitated by noncompliance with beta-blocker therapy. (Level of Difficulty: Intermediate.).
PMCID:8298547
PMID: 34317300
ISSN: 2666-0849
CID: 4949452
Deep learning models for electrocardiograms are susceptible to adversarial attack
Han, Xintian; Hu, Yuxuan; Foschini, Luca; Chinitz, Larry; Jankelson, Lior; Ranganath, Rajesh
Electrocardiogram (ECG) acquisition is increasingly widespread in medical and commercial devices, necessitating the development of automated interpretation strategies. Recently, deep neural networks have been used to automatically analyze ECG tracings and outperform physicians in detecting certain rhythm irregularities1. However, deep learning classifiers are susceptible to adversarial examples, which are created from raw data to fool the classifier such that it assigns the example to the wrong class, but which are undetectable to the human eye2,3. Adversarial examples have also been created for medical-related tasks4,5. However, traditional attack methods to create adversarial examples do not extend directly to ECG signals, as such methods introduce square-wave artefacts that are not physiologically plausible. Here we develop a method to construct smoothed adversarial examples for ECG tracings that are invisible to human expert evaluation and show that a deep learning model for arrhythmia detection from single-lead ECG6 is vulnerable to this type of attack. Moreover, we provide a general technique for collating and perturbing known adversarial examples to create multiple new ones. The susceptibility of deep learning ECG algorithms to adversarial misclassification implies that care should be taken when evaluating these models on ECGs that may have been altered, particularly when incentives for causing misclassification exist.
PMID: 32152582
ISSN: 1546-170x
CID: 4349692
QTc Prolongation Risk Evaluation in Female COVID-19 Patients Undergoing Chloroquine and Hydroxychloroquine With/Without Azithromycin Treatment
Grewal, Sarah; Jankelson, Lior; van den Broek, Marcel P H; Cour, Martin; Bachmann, Gloria; Kostis, John B; Misra, Kamana
Women have higher risk for developing TdP in response to ventricular repolarization prolonging drugs. Hundreds of trials are administering chloroquine and hydroxychloroquine with/without azithromycin to COVID-19 patients. While an overall prolonged QTc has been reported in COVID-19 patients undergoing these treatments, the question on even higher QTc elevation risk in thousands of female COVID-19 patients undergoing these treatments remains unanswered. We therefore explore data reported and shared with us to evaluate safety and efficacy of antimalaria pharmacotherapies in female COVID-19 patients. Although we observed longer mean QTc intervals in female patients in 2 of the 3 cohorts reviewed, the sex disproportionality in COVID-19 hospitalizations precludes a clear sex mediated QTc interval elevation risk association in the female COVID-19 patients undergoing acute treatment regimens. Adoption of study designs that include observation of sex mediated differential triggering of cardiac electrical activity by these drugs is warranted.
PMCID:7498717
PMID: 33102533
ISSN: 2297-055x
CID: 5093062
Quantitative analysis of ablation technique predicts arrhythmia recurrence following atrial fibrillation ablation
Jankelson, Lior; Dai, Matthew; Bernstein, Scott; Park, David; Holmes, Douglas; Aizer, Anthony; Chinitz, Larry; Barbhaiya, Chirag
BACKGROUND:Optimal ablation technique, including catheter-tissue contact during atrial fibrillation (AF) radiofrequency (RF) ablation, is associated with improved procedural outcomes. We used a custom developed software to analyze high-frequency catheter position data to study the interaction between catheter excursion during lesion placement, lesion-set sequentiality, and arrhythmia recurrence. METHODS:A total of 100 consecutive patients undergoing first-time RF ablation for paroxysmal AF were analyzed. Spatial positioning of the ablation catheter sampled at 60 Hz during RF application was extracted from the CARTO3 system (Biosense Webster Inc, USA) and analyzed using custom-developed MATLAB software to determine precise catheter spatial 3D excursion during RF ablation. The primary end point was freedom from atrial arrhythmia lasting longer than 30 seconds after a single ablation procedure. RESULTS:At 1 year, 86% of patients were free from recurrent arrhythmia. There was no significant difference in clinical, echocardiographic, or ablation characteristics between patients with and without recurrent arrhythmia. Analyzing 15,356,998 position data points revealed that lesion-set sequentiality and mean lesion catheter excursion were predictors of arrhythmia recurrence. Analyzing arrhythmia recurrence by mean single-lesion catheter excursion (excursion >2.81 mm) and by sequentiality (using 46% of lesions with interlesion distance >6 mm as cutoff) revealed significantly increased arrhythmia recurrence in the higher excursion group (23% vs 6%, P = .03) and in the less sequential group (24% vs 4%, P = .02). CONCLUSIONS:Ablation lesion sequentiality measured by catheter interlesion distance and catheter stability measured by catheter excursion during lesion placement are potentially modifiable factors affecting arrhythmia recurrence after RF ablation for AF.
PMID: 31835167
ISSN: 1097-6744
CID: 4235072
Impact of RNA testing on cardiac variant interpretation and patient management [Case Report]
Jankelson, Lior; Zimmermann, Heather; Fowler, Steven; Borneman, Linda; Conner, Blair; Wu, Sitao; Karam, Rachid; Chinitz, Larry; Cerrone, Marina
PMCID:6700669
PMID: 31453089
ISSN: 2214-0271
CID: 4054342
PERSISTENT ATRIAL FIBRILLATION CATHETER ABLATION OUTCOMES STRATIFIED BY LEFT ATRIAL POSTERIOR WALL ISOLATION LESION SET CHARACTERISTICS [Meeting Abstract]
Barbhaiya, C R; Kogan, E V; Knotts, R; Pelaez, A V; Jankelson, L; Bernstein, S A; Park, D S; Holmes, D; Aizer, A; Chinitz, L A
Background: Left atrial posterior wall (LAPW) isolation is associated with favorable outcomes for catheter ablation of persistent atrial fibrillation (AF) in several studies. Reported techniques for LAPW isolation include ablation at the periphery without ablation within the LAPW, and high density ablation of all sites of electrical activity within the LAPW. The proportion of LA isolated by the lesion set in various reports also varies greatly. The optimal technique to achieve LAPW isolation is not clear.
Objective(s): To assess impact of ablation lesion density within the LAPW and dimensions of LAPW isolation region on arrhythmia recurrence in catheter ablation of persistent AF.
Method(s): LAPW lesion density, and LAPW isolation surface area relative to total LA surface area were calculated using electroanatomic maps of 110 consecutive patients undergoing LAPW isolation for persistent AF (CARTO 3, Biosense Webster, Inc.) LAPW isolation lesion sets were created at the discretion of 5 experienced operators after LA voltage mapping. LAPW and PV entrance block and exit block were confirmed. Arrhythmia recurrence at one year was assessed by the Kaplan-Meier method.
Result(s): LAPW lesion density ranged from 0% - 99%. Proportion of LA surface area isolated ranged from 35% - 75%. There was no significant difference in arrhythmia-free survival by quartile of LAPW ablation density (81% vs. 68% vs. 85% vs. 78%, p=0.8), or by quartile of LA surface area proportion isolated (85% vs. 75% vs. 79% vs. 74%, p=0.3). Voltage map guided LAPW isolation resulted in no significant difference in incidence of recurrent arrhythmia by quartile of total LA surface area (81% vs. 78% vs. 78% vs. 74%, p=0.5).
Conclusion(s): Neither the density of ablation within the LAPW nor the dimensions of the isolated region predicted arrhythmia-free survival LAPW isolation for catheter ablation of persistent AF. Voltage map guided LAPW isolation resulted in similar ablation efficacy regardless of LA size.
Copyright
EMBASE:2002272949
ISSN: 1556-3871
CID: 4007262
RAPID PACING AND HIGH FREQUENCY JET VENTILATION SYNERGISTICALLY IMPROVE CATHETER STABILITY DURING AF ABLATION [Meeting Abstract]
Aizer, A; Qiu, J K; Cheng, A; Wu, P; Holmes, D; Jankelson, L; Bernstein, S A; Park, D S; Linton, P; Barbhaiya, C R; Chinitz, L A
Background: Increased catheter stability during AF ablation is associated with higher ablation success rates. Rapid cardiac pacing and high frequency jet ventilation (HFJV) have both been independently shown to improve catheter stability. Simultaneous modulation of cardiac and respiratory motion has not been previously studied.
Objective(s): To study the effects of modulating heart rate and respiratory rate simultaneously on catheter stability.
Method(s): Forty paroxysmal AF patients were randomized to four study conditions. Ablation lesions were created at 15 prespecified locations. Twenty patients received atrial pacing (500 msec) during the first half of each lesion; twenty patients were paced during the second half of each lesion. Within each group, half received HFJV and half received standard ventilation. Contact force (CF) variability, defined as CF standard deviation, was compared between study groups.
Result(s): Compared to sinus rhythm and standard ventilation, rapid pacing (5.45 g vs. 5.86 g; p=0.006) and HFJV (5.10 g; p=0.003) each significantly reduced mean CF standard deviation. Simultaneous pacing and HFJV produced even greater reduction of mean CF standard deviation (4.29 g; p<0.001) (Figure). Pacing and HFJV alone had similar effects on mean CF variability (p=0.2).
Conclusion(s): Rapid pacing and HFJV synergistically improve catheter stability during AF ablation. Simultaneous pacing with HFJV further optimizes catheter stability over pacing or HFJV alone and may improve ablation outcomes. [Figure presented]
Copyright
EMBASE:2002296075
ISSN: 1556-3871
CID: 4001842