Searched for: in-biosketch:true
person:raze01
Fluoroscopy-Guided Removal of Tethered Surgical Drain via Guidewire Electrification: A Case Report [Case Report]
Feng, Austin; Orillac, Cordelia; Raz, Eytan; Pacione, Donato; Frempong-Boadu, Anthony
Tethered postoperative drains are not uncommon complications that often require open removal in the operating room, which can increase risks of surgical site infection as well as length of hospitalization. We present a novel method of tethered drain removal through guidewire electrification. A retained deep drain following a posterior cervical laminectomy and fusion was identified after failed manual removal. Under fluoroscopic guidance, the retaining suture was indirectly identified through the obstruction of an inserted guidewire, through which monopolar cautery was applied, breaking the suture and allowing drain removal. The original incision did not need to be re-opened. While further investigation is necessary for validation, this technique shows great promise as an alternative to open removal.
PMCID:12302301
PMID: 40726847
ISSN: 2168-8184
CID: 5903242
Clinical Management of Cerebral Aneurysms-Endoluminal
Shapiro, Maksim; Nossek, Erez; Sharashidze, Vera; Sahlein, Daniel H; Rutledge, Caleb; Baranoski, Jacob; Chung, Charlotte Y; Riina, Howard; Nelson, Peter Kim; Raz, Eytan
Definitive endoluminal reconstruction, widely known as flow diversion, revolutionized treatment of brain aneurysms. A range of targets, by location, size, etiology, and acuity, can be cured with an excellent risk/benefit profile. Requirement for effective antiplatelet state is balanced with superior treatment durability. Implant and delivery system technology continue to evolve. Some aneurysm types/locations remain undertreated. Maximizing efficacy while minimizing risks requires deep understanding of flow diversion principles, pathologic anatomy, endoluminal implants, delivery systems, and clinical management.
PMID: 40634005
ISSN: 1557-9867
CID: 5890972
The Silk Vista Baby Study: A Multicenter Aneurysm Report From North America and Europe
Hanel, Ricardo A; de Toledo, Otavio F; De Oliveira Souza, Natalia V; Gutierrez-Aguirre, Salvador F; Killer-Oberpfalzer, Monika; Raz, Eytan; Shapiro, Maksim; Kass-Hout, Tareq; Hurley, Michael; Morsi, Rami Z; Srinivasan, Visish M; Jankowitz, Brian T; Davis, Pierce; Siddiqui, Adnan; Jaikumar, Vinay; Cortez, Gustavo M; Kass-Hout, Omar; Becske, Tibor; Grandhi, Ramesh; Kilburg, Craig; Lopes, Demetrius K; Ducruet, Andrew F; Elijovich, Lucas; Britz, Gavin; Toledo, Maria M; Seinfeld, Joshua; Starke, Robert M; Nogueira, Raul G; Bender, Matthew T; Kan, Peter T; Lazaro, Tyler; Benalia, Victor H C; Erazu, Fernanda R; Lara-Velazquez, Montserrat; Aghaebrahim, Amin; Sauvageau, Eric; Pereira, Vitor M
BACKGROUND AND OBJECTIVES/OBJECTIVE:The Silk Vista Baby (SVB) flow diverter (FD) stent (Balt SAS) is the first device designed for treating distally located brain aneurysms. It can be delivered through a 0.017-inch ID microcatheter, enabling access to small, distal vessels. The aim of this study was to evaluate the effectiveness, safety, technical success, occlusion rate, and clinical outcomes of the SVB device. METHODS:This retrospective, multicenter study included data from 18 centers from November 2023 to September 2024. Procedures were performed by experienced neurointerventionalists following institutional standards of care. Outcomes analyzed included effectiveness, safety, and aneurysm occlusion rates. Descriptive analyses and Pearson χ2 or Independent t-Test were used for statistical evaluation. RESULTS:A total of 95 patients, mean age 55.4 years, were included. A total of 31% of aneurysms were ruptured at admission. Most (58.3%) were located in the anterior circulation, and 45% had previous treatment, mainly coiling (69.4%). Complication rates were higher for ruptured aneurysms (24.1%) compared with unruptured ones (9.2%). Two deaths occurred, 1 (1.1%) related to the procedure. At discharge, 87% of patients had modified Rankin Scale ≤2. The latest follow-up showed overall complete/near-complete occlusion rates of 76.1%, with 81.14% for ruptured and 73.43% for unruptured aneurysms. Technical success was higher in unruptured cases (100% vs 93.1%). CONCLUSION/CONCLUSIONS:Our case series demonstrated the efficacy of the SVB with a high rate of technical success. The occlusion rates for ruptured cases are comparable with those of other FDs. However, the rates are lower for unruptured cases. This discrepancy is likely due to the characteristics of the aneurysms, particularly in the presence of side branches in bifurcation lesions. The SVB safety profile is similar to other FDs in unruptured cases, while the ruptured group presented more complications.
PMID: 40637427
ISSN: 1524-4040
CID: 5891022
Clinical Management of Cerebral Aneurysms-: Endosaccular
Raz, Eytan; Chung, Charlotte Y; Nossek, Erez; Sahlein, Daniel H; Sharashidze, Vera; Shapiro, Maksim
Although the concept of treating cerebral aneurysms by filling the sac from the inside (endosaccular) started many years ago first with detachable balloons and then coils, the use of a single metallic resheathable device acting as a flow disruptor is a much more recent innovation. The most studied device among these is certainly the WEB, which became part of standard clinical practice for treatment of wide-neck bifurcation aneurysms. This study reviews the most important features of the WEB device with a short summary of the most important literature. A small section at the end reviews also other endosaccular devices.
PMID: 40634004
ISSN: 1557-9867
CID: 5890962
Follow-up Imaging in Treated and Untreated Cerebral Aneurysms
Chung, Charlotte Y; Shapiro, Maksim; Nossek, Erez; Sharashidze, Vera; Rutledge, Caleb; Raz, Eytan
Imaging follow-up is an established component of intracranial aneurysm management that allows ongoing assessment of rupture risk and timely intervention to maintain protection from bleeding. Yet the frequency, duration, and imaging modality for follow-up vary widely. This review outlines contemporary imaging techniques and practice for follow-up of treated and untreated aneurysms, highlighting existing knowledge gaps and technical limitations that limit standardization. Updated evidence on the expected evolution and long-term outcome of common treatment strategies is presented to guide accurate reporting of radiological outcome after treatment and considerations regarding follow-up regimen.
PMID: 40634007
ISSN: 1557-9867
CID: 5890982
Prognostic value of cerebral venous outflow profiles for outcomes prediction following reperfusion therapy in acute ischemic stroke: a meta-analysis
Kelani, Hesham; Abdelraouf, Mohamed R; Rath, Shree; Mohamed, Shrouk F; Salamah, Hazem Mohamed; Mehmood, Qasim; Ansab, Muhammad; Kumar, Danisha; Elazim, Ahmed Abd; Greene-Chandos, Diana; Berekashvili, Ketevan; Tiwari, Ambooj; Vulkanov, Volodymyr; Lerner, David P; Raz, Eytan
BACKGROUND:Recent studies have suggested that favorable venous outflow (VO) may be a promising imaging biomarker to predict clinical outcomes following reperfusion therapy in patients with acute ischemic stroke caused by large vessel occlusion (AIS-LVO). METHODS:A comprehensive literature search was conducted in PubMed, Scopus, WOS, and Cochrane to identify studies that evaluated VO profiles, assessed using the Cortical Vein Opacification Score (COVES). The risk ratio (RR) and 95% confidence interval (CI) for the outcomes, including functional independence, assessed by modified rankin scale at 90 days (mRS 0-2), hemorrhagic infarction, parenchymal hematoma, 90-day mortality, intracranial hemorrhage (ICH), and symptomatic ICH (sICH), were calculated and analyzed using the 'meta' package in R version 4.4.1. RESULTS:A total of six studies encompassing 2249 patients were included. Patients with favorable VO had a higher likelihood of achieving functional independence at 90 days (RR = 2.15; 95% CI: 1.35, 3.42; p = 0.01) and a lower incidence of 90-day mortality (RR = 0.39; 95% CI: 0.30, 0.51; p < 0.01), parenchymal hematoma (RR = 0.36; 95% CI: 0.27, 0.47; p < 0.01). Furthermore, sICH was less frequent in patients with favorable VO (RR = 0.39; 95% CI: 0.17, 0.89; p = 0.03). However, hemorrhagic infarction and any ICH did not differ significantly between the two groups (p-values: 0.06 and 0.32, respectively). CONCLUSION/CONCLUSIONS:VO is a promising imaging biomarker for predicting outcomes in patients with AIS-LVO following reperfusion therapy. Prospective clinical trials are warranted to investigate the predictive value of VO, assessed on multiphasic computed tomography angiography (CTA), as a prognostic marker in this patient population.
PMID: 40627189
ISSN: 1432-1920
CID: 5890602
The Role of AI-driven Volumetric Aneurysm Analysis in the Management of Cerebral Aneurysms
Sahlein, Daniel H; DeNardo, Andrew J; Amuluru, Krishna; Gibson, Daniel P; Raz, Eytan; Shapiro, Maksim; Payner, Troy D; Kulwin, Charles G; Shah, Kushal J
This article looks at the current state of aneurysm risk modeling, exploring the limitations of linear measurement. It reviews articles using Food and Drug Administration (FDA)-approved artificial intelligence-driven volumetric measurement tools both for evaluating potential aneurysm growth in patients being managed conservatively as well as in assessing morphologic change prerupture and postrupture. The challenges of defining the aneurysm boundary are explored, and a novel definition of aneurysm/parent artery interface is proposed.
PMID: 40634003
ISSN: 1557-9867
CID: 5890952
Silk Vista Baby for the treatment of distal anterior cerebral artery aneurysms
Scarcia, Luca; Clarençon, Frédéric; Dmytriw, Adam A; Shotar, Eimad; Jabbour, Pascal; Psychogios, Marios; Sporns, Peter; Puri, Ajit S; Hassan, Ameer E; Algin, Oktay; Möhlenbruch, Markus A; Russo, Riccardo; Bergui, Mauro; Goren, Oded; Bankole, Nourou Dine A; Boulouis, Gregoire; Morimoto, Takeshi; Pop, Raoul; Ho, Joanna Wk; Ferrario, Ángel; Pujol Lereis, Virginia; Cooper, Jared; Salsano, Giancarlo; Li, Yan-Lin; Consoli, Arturo; Sgreccia, Alessandro; Raz, Eytan; Chung, Charlotte; Burel, Julien; Papagiannaki, Chrysanthi; Baqir Hassan, Khawaja Muhammad; Tao, Hong; Rautio, Riitta; Sinislao, Matias; Ruggiero, Maria; Lafe, Elvis; Da Ros, Valerio; Bellini, Luigi; Gabrieli, Joseph Domenico; Causin, Francesco; Levitt, Michael; Caragliano, Antonio Armando; Vinci, Sergio Lucio; Bellanger, Guillaume; Cognard, Christophe; Marnat, Gaultier; Saleille, Lisa; Nimbucci, Nicola; Capasso, Francesco; Piano, Mariangela; Rollo, Claudia; Guedon, Alexis; Romi, Andrea; Di Caterino, Fortunato; Biondi, Alessandra; Farhat, Firas; Vyval, Mykola; Guenego, Adrien; Nguyen, Thanh; Abdalkader, Mohamad; Gunkan, Ahmet; Agripnidis, Thibault; Fuschi, Maurizio; Pereira, Vitor Mendes; Alexandre, Andrea M; Pedicelli, Alessandro; ,
PURPOSE/OBJECTIVE:Treating small-caliber vessel aneurysms with flow diverters poses challenges due to narrow luminal diameters and tortuous vasculature, which complicate the navigation and deployment of conventional devices using standard microcatheters. The Silk Vista Baby (SVB, Balt, Montmorency, France) flow diverter was developed to treat intracranial aneurysms located in smaller vessels or more distal segments and is compatible with 0.017″ microcatheters. We present the largest multicenter analysis to date evaluating the outcomes of SVB use in unruptured distal anterior cerebral artery (DACA) aneurysms. METHODS:Retrospective data from 20 centers were reviewed for patients with unruptured DACA aneurysms treated with the SVB. Demographic information, clinical presentation, radiographic characteristics, complications, and outcomes were recorded. RESULTS:Seventy-nine patients (79 DACA aneurysms) were treated between January 2018 and December 2022; 59 were female (74.7%), and the median age was 61 years (IQR 53-67). Most aneurysms were saccular (89.9%), and 65.8% involved a branch. The median parent vessel diameter was 1.9 mm (IQR 1.7-2.1). A single stent was implanted in 97.5% of cases; 2.5% required two stents. The median imaging follow-up duration was 12 months (IQR 9.5-24). At the last follow-up, 76% of aneurysms showed complete or near-complete occlusion (O'Kelly-Marotta scale C or D, Raymond-Roy 1 or 2). Overall, thromboembolic or hemorrhagic complications occurred in 14% of patients, with two cases being symptomatic. The mortality rate was 0%, and the retreatment rate was 1.3%. CONCLUSION/CONCLUSIONS:In this multicenter series, the SVB flow diverter represented a valuable treatment option for distal anterior cerebral artery (DACA) aneurysms.
PMID: 40601068
ISSN: 1432-1920
CID: 5888012
Macrowire-only direct aspiration first-pass technique for endovascular mechanical thrombectomy: Multicenter technical series using the 0.035″ aristotle Colossus wire
Ares, William; Tonetti, Daniel; Koneru, Manisha; Dalkilic, Ahmet; Salah, Walid; Brinjikji, Waleed; Rajjoub, Kenan; Raz, Eytan; Khawaja, Ayaz; Southwood, Christopher; Dalyai, Richard; Birnbaum, Lee; Chowdhry, Shakeel; Do, Huy; Joyce, Evan; Calnan, Daniel; Malek, Adel; Grandhi, Ramesh
BackgroundLarger "macrowires" may facilitate microcatheter-free delivery of large-bore aspiration catheters (ACs) for intracranial endovascular mechanical thrombectomy. We examined the safety and efficacy of the Aristotle Colossus Guidewire for this use.MethodsIn this retrospective analysis of prospective data from 12 institutions, we identified anterior circulation endovascular mechanical thrombectomy cases involving the Aristotle Colossus guidewire over a 12-month period. The primary efficacy endpoint was successful delivery of the AC to the site without the use of adjunct devices. Multivariable logistic regression was performed with clinically relevant covariables.ResultsIn 122 patients (median age 74 years (interquartile range (IQR) 63-82)), most intracranial occlusions were in the M1 segment of the middle cerebral artery (95/122, 78.0%). The primary endpoint of microcatheter-free AC delivery was met in 87.7% (107/122) of patients; 93/122 (76.2%) patients underwent microcatheter-free delivery with successful reperfusion via contact aspiration (modified thrombolysis in cerebral infarction grade ≥ 2B). The median number of passes was 1 (IQR 1-2). Multivariable regression demonstrated that severe internal carotid artery tortuosity or cervical loop presence (odds ratio (OR): 0.09, 95% confidence interval (CI): 0.01-0.54, p = 0.01) and presence of intracranial atherosclerotic disease (OR: 0.15, 95% CI: 0.03-0.83, p = 0.03) were significantly associated with lower odds of successful AC delivery over the guidewire. Intraprocedural vasospasm occurred in 4.9% (6/122) of cases; there were no reports of vessel dissection or perforation.ConclusionsWe demonstrate the favorable performance of the Aristotle Colossus guidewire for anterior circulation ischemic stroke intervention. The macrowire appears to safely facilitate navigation of the neurovasculature by large-bore ACs without the need for microcatheter and/or stentriever.
PMCID:12098323
PMID: 40400317
ISSN: 2385-2011
CID: 5853252
Innovating stroke care: A performance study of the ALGO smart pump in smart static mode
Snyder, Thomas; Ares, William; Starke, Robert M; Shapiro, Maksim; Raz, Eytan; Kass-Hout, Tareq; Ramakrishnan, Pankajavalli; Fox, Chris; Jankowitz, Brian T
INTRODUCTION/BACKGROUND:While revascularization rates have improved for mechanical thrombectomy (MT) in acute ischemic stroke, advancements in aspiration pumps have been limited. The ALGO Smart Pump (Von Vascular, Sunrise, FL) is a small on-field, operator-driven pump offering two aspiration modes: Adaptive Pulsatile Aspiration (APA™) Mode and a continuous 'Static' mode. This study evaluates the performance of the ALGO Smart Pump's Static Mode compared to a commercially available aspiration pump. METHODS:Operators performed aspiration thrombectomy in a flow model with ALGO and the Penumbra ENGINE (Penumbra, Alameda, CA) using medium (ID.036-.057") to large (ID.068-.071) bore aspiration catheters. Primary endpoint was complete clot ingestion (CCI), defined as the full ingestion of the clot within the catheter or pump's canister, without any clot at the catheter tip or evidence of embolization to new territories (ENT). Secondary endpoints included first pass recanalization, ENT and total aspiration time. RESULTS:When comparing all catheters, ALGO Smart Pump achieved CCI in 154 of 180 thrombectomies (85.6 %) compared to Penumbra ENGINE achieving CCI in 136 of 180 thrombectomies (75.6 %). The CCI rate between pump types across all catheters was statistically significant (p = 0.008), favoring ALGO pump. There was no difference between pump type on aspiration time. CONCLUSION/CONCLUSIONS:The ALGO Smart Pump may represent an alternative in MT, with potential higher effectiveness compared to existing available aspiration pumps with additional user-friendly benefits including a sterile, smaller, on-field apparatus.
PMID: 40349446
ISSN: 1872-6968
CID: 5843812