Off-Label use of Woven EndoBridge device for intracranial brain aneurysm treatment: Modeling of occlusion outcome

Essibayi, Muhammed Amir; Jabal, Mohamed Sobhi; Musmar, Basel; Adeeb, Nimer; Salim, Hamza; Aslan, Assala; Cancelliere, Nicole M; McLellan, Rachel M; Algin, Oktay; Ghozy, Sherief; Lay, Sovann V; Guenego, Adrien; Renieri, Leonardo; Carnevale, Joseph; Saliou, Guillaume; Mastorakos, Panagiotis; Naamani, Kareem El; Shotar, Eimad; Premat, Kevin; Möhlenbruch, Markus; Kral, Michael; Doron, Omer; Chung, Charlotte; Salem, Mohamed M; Lylyk, Ivan; Foreman, Paul M; Vachhani, Jay A; Shaikh, Hamza; Župančić, Vedran; Hafeez, Muhammad U; Catapano, Joshua; Waqas, Muhammad; Yavuz, Kivilcim; Gunes, Yasin Celal; Rabinov, James D; Ren, Yifan; Schirmer, Clemens M; Piano, Mariangela; Kühn, Anna L; Michelozzi, Caterina; Starke, Robert M; Hassan, Ameer; Ogilvie, Mark; Nguyen, Anh; Jones, Jesse; Brinjikji, Waleed; Nawka, Marie T; Psychogios, Marios; Ulfert, Christian; Diestro, Jose Danilo Bengzon; Pukenas, Bryan; Burkhardt, Jan-Karl; Huynh, Thien; Gutierrez, Juan Carlos Martinez; Sheth, Sunil A; Spiegel, Gary; Tawk, Rabih; Lubicz, Boris; Panni, Pietro; Puri, Ajit S; Pero, Guglielmo; Nossek, Erez; Raz, Eytan; Killer-Oberfalzer, Monika; Griessenauer, Christoph J; Asadi, Hamed; Siddiqui, Adnan; Brook, Allan L; Haranhalli, Neil; Ducruet, Andrew F; Albuquerque, Felipe C; Regenhardt, Robert W; Stapleton, Christopher J; Kan, Peter; Kalousek, Vladimir; Lylyk, Pedro; Boddu, Srikanth; Knopman, Jared; Aziz-Sultan, Mohammad A; Tjoumakaris, Stavropoula I; Clarençon, Frédéric; Limbucci, Nicola; Cuellar-Saenz, Hugo H; Jabbour, Pascal M; Pereira, Vitor Mendes; Patel, Aman B; Altschul, David; Dmytriw, Adam A; ,
INTRODUCTION/BACKGROUND:The Woven EndoBridge (WEB) device is emerging as a novel therapy for intracranial aneurysms, but its use for off-label indications requires further study. Using machine learning, we aimed to develop predictive models for complete occlusion after off-label WEB treatment and to identify factors associated with occlusion outcomes. METHODS:This multicenter, retrospective study included 162 patients who underwent off-label WEB treatment for intracranial aneurysms. Baseline, morphological, and procedural variables were utilized to develop machine-learning models predicting complete occlusion. Model interpretation was performed to determine significant predictors. Ordinal regression was also performed with occlusion status as an ordinal outcome from better (Raymond Roy Occlusion Classification [RROC] grade 1) to worse (RROC grade 3) status. Odds ratios (OR) with 95 % confidence intervals (CI) were reported. RESULTS:The best performing model achieved an AUROC of 0.8 for predicting complete occlusion. Larger neck diameter and daughter sac were significant independent predictors of incomplete occlusion. On multivariable ordinal regression, higher RROC grades (OR 1.86, 95 % CI 1.25-2.82), larger neck diameter (OR 1.69, 95 % CI 1.09-2.65), and presence of daughter sacs (OR 2.26, 95 % CI 0.99-5.15) were associated with worse aneurysm occlusion after WEB treatment, independent of other factors. CONCLUSION/CONCLUSIONS:This study found that larger neck diameter and daughter sacs were associated with worse occlusion after WEB therapy for aneurysms. The machine learning approach identified anatomical factors related to occlusion outcomes that may help guide patient selection and monitoring with this technology. Further validation is needed.
PMID: 39069148
ISSN: 1532-8511
CID: 5696242

Complex intracranial aneurysms: a DELPHI study to define associated characteristics

Diana, Francesco; Romoli, Michele; Raz, Eytan; Agid, Ronit; Albuquerque, Felipe C; Arthur, Adam S; Beck, Jürgen; Berge, Jerome; Boogaarts, Hieronymus D; Burkhardt, Jan-Karl; Cenzato, Marco; Chapot, René; Charbel, Fady T; Desal, Hubert; Esposito, Giuseppe; Fifi, Johanna T; Florian, Stefan; Gruber, Andreas; Hassan, Ameer E; Jabbour, Pascal; Jadhav, Ashutosh P; Korja, Miikka; Krings, Timo; Lanzino, Giuseppe; Meling, Torstein R; Morcos, Jaques; Mosimann, Pascal J; Nossek, Erez; Pereira, Vitor Mendes; Raabe, Andreas; Regli, Luca; Rohde, Veit; Siddiqui, Adnan H; Tanikawa, Rokuya; Tjoumakaris, Stavropoula I; Tomasello, Alejandro; Vajkoczy, Peter; Valvassori, Luca; Velinov, Nikolay; Walsh, Daniel; Woo, Henry; Xu, Bin; Yoshimura, Shinichi; van Zwam, Wim H; Peschillo, Simone
PURPOSE/OBJECTIVE:Intracranial aneurysms present significant health risks, as their rupture leads to subarachnoid haemorrhage, which in turn has high morbidity and mortality rates. There are several elements affecting the complexity of an intracranial aneurysm. However, criteria for defining a complex intracranial aneurysm (CIA) in open surgery and endovascular treatment could differ, and actually there is no consensus on the definition of a "complex" aneurysm. This DELPHI study aims to assess consensus on variables defining a CIA. METHODS:An international panel of 50 members, representing various specialties, was recruited to define CIAs through a three-round Delphi process. The panelists participated in surveys with Likert scale responses and open-ended questions. Consensus criteria were established to determine CIA variables, and statistical analysis evaluated consensus and stability. RESULTS:In open surgery, CIAs were defined by fusiform or blister-like shape, dissecting aetiology, giant size (≥ 25 mm), broad neck encasing parent arteries, extensive neck surface, wall calcification, intraluminal thrombus, collateral branch from the sac, location (AICA, SCA, basilar), vasospasm context, and planned bypass (EC-IC or IC-IC). For endovascular treatment, CIAs included giant size, very wide neck (dome/neck ratio ≤ 1:1), and collateral branch from the sac. CONCLUSIONS:The definition of aneurysm complexity varies by treatment modality. Since elements related to complexity differ between open surgery and endovascular treatment, these consensus criteria of CIAs could even guide in selecting the best treatment approach.
PMID: 38990336
ISSN: 0942-0940
CID: 5699032

Predictors of Aneurysm Obliteration in Patients Treated with the WEB Device: Results of a Multicenter Retrospective Study

Mastorakos, Panagiotis; Naamani, Kareem El; Adeeb, Nimer; Lan, Mathews; Castiglione, James; Khanna, Omaditya; Ghosh, Ritam; Bengzon Diestro, Jose Danilo; Dibas, Mahmoud; McLellan, Rachel M; Algin, Oktay; Ghozy, Sherief; Cancelliere, Nicole M; Aslan, Assala; Cuellar-Saenz, Hugo H; Lay, Sovann V; Guenego, Adrien; Renieri, Leonardo; Carnevale, Joseph; Saliou, Guillaume; Shotar, Eimad; Premat, Kevin; Möhlenbruch, Markus; Kral, Michael; Vranic, Justin E; Chung, Charlotte; Salem, Mohamed M; Lylyk, Ivan; Foreman, Paul M; Vachhani, Jay A; Shaikh, Hamza; Župančić, Vedran; Hafeez, Muhammad U; Catapano, Joshua; Waqas, Muhammad; Tutino, Vincent M; Ibrahim, Mohamed K; Mohammed, Marwa A; Rabinov, James D; Ren, Yifan; Schirmer, Clemens M; Piano, Mariangela; Bullrich, Maria Bres; Mayich, Michael; Kühn, Anna L; Michelozzi, Caterina; Elens, Stéphanie; Starke, Robert M; Hassan, Ameer E; Ogilvie, Mark; Nguyen, Anh; Jones, Jesse; Brinjikji, Waleed; Psychogios, Marios; Ulfert, Christian; Spears, Julian; Jankowitz, Brian T; Burkhardt, Jan-Karl; Domingo, Ricardo A; Huynh, Thien; Tawk, Rabih G; Lubicz, Boris; Nawka, Marie T; Panni, Pietro; Puri, Ajit S; Pero, Guglielmo; Nossek, Erez; Raz, Eytan; Killer-Oberpfalzer, Monika; Ozates, M Ozgur; Ayberk, Giyas; Regenhardt, Robert W; Griessenauer, Christoph J; Asadi, Hamed; Siddiqui, Adnan; Ducruet, Andrew F; Albuquerque, Felipe C; Patel, Nirav J; Stapleton, Christopher J; Kan, Peter; Kalousek, Vladimir; Lylyk, Pedro; Boddu, Srikanth; Knopman, Jared; Aziz-Sultan, Mohammad A; Clarençon, Frédéric; Limbucci, Nicola; Zanaty, Mario; Martinez-Gutierrez, Juan Carlos; Sheth, Sunil; Spiegel, Gary; Abbas, Rawad; Amllay, Abdelaziz; Tjoumakaris, Stavropoula I; Gooch, Michael R; Herial, Nabeel A; Rosenwasser, Robert H; Zarzour, Hekmat; Schmidt, Richard F; Pereira, Vitor Mendes; Patel, Aman B; Jabbour, Pascal M; Dmytriw, Adam A
BACKGROUND AND PURPOSE/OBJECTIVE:Despite the numerous studies evaluating the occlusion rates of aneurysms following WEB embolization, there are limited studies identifying predictors of occlusion. Our purpose was to identify predictors of aneurysm occlusion and the need for retreatment. MATERIALS AND METHODS/METHODS:This is a review of a prospectively maintained database across 30 academic institutions. We included patients with previously untreated cerebral aneurysms embolized using the WEB who had available intraprocedural data and long-term follow-up. RESULTS:< .001), offering a specificity of 87% and a positive predictive value of 85% for long-term occlusion. CONCLUSIONS:Intraprocedural occlusion can be used to predict the chance of long-term aneurysm occlusion and the need for retreatment after embolization with a WEB device. Smoking, aneurysm size, and the presence of an aneurysm wall branch are associated with decreased chances of successful treatment.
PMCID:11286027
PMID: 38977286
ISSN: 1936-959x
CID: 5698752

Comprehensive Analysis of Post-Pipeline Endothelialization and Remodeling

Sharashidze, Vera; Raz, Eytan; Nossek, Erez; Kvint, Svetlana; Riina, Howard; Rutledge, Caleb; Baranoski, Jacob; Khawaja, Ayaz; Chung, Charlotte; Nelson, Peter Kim; Shapiro, Maksim
BACKGROUND AND PURPOSE/OBJECTIVE:Successful post-flow-diverter endoluminal reconstruction is widely believed to require endothelial overgrowth of the aneurysmal inflow zone. However, endothelialization/neointimal overgrowth is a complex process, over which we currently have very limited influence. Less emphasized is vascular remodeling of the target arterial segment, the dynamic response of the vessel to flow-diverter implantation. This process is distinct from flow modifications in covered branches. It appears that basic angiographic methods allow simple and useful observations. The purpose of this article was to quantitatively evaluate observable postimplantation changes in target vessels following deployment of Pipeline endoluminal constructs. MATERIALS AND METHODS/METHODS:One hundred consecutive adults with unruptured, previously untreated, nondissecting aneurysms treated with the Pipeline Embolization Device with Shield Technology and the availability of follow-up conventional angiography were studied with 2D DSA imaging. Target vessel size; Pipeline Embolization Device diameter; endothelial thickness; and various demographic, antiplatelet, and device-related parameters were recorded and analyzed. RESULTS:The thickness of neointimal overgrowth (mean, 0.3 [SD, 0.1] mm; range, 0.1-0.7 mm) is inversely correlated with age and is independent of vessel size, smoking status, sex, and degree of platelet inhibition. The decrease in lumen diameter caused by neointimal overgrowth, however, appears counteracted by outward remodeling (dilation) of the target arterial segment. This leads to an increase in the diameter with a corresponding decrease in length (foreshortening) of the implanted Pipeline Embolization Device. This physiologic remodeling process affects optimally implanted devices and is not a consequence of stretching, device migration, vasospasm, and so forth. A direct, linear, statistically significant relationship exists between the degree of observed outward remodeling and the diameter of the implanted Pipeline Embolization Device relative to the target vessel. Overall, remodeled arterial diameters were reduced by 15% (SD, 10%) relative to baseline and followed a normal distribution. Clinically relevant stenosis was not observed. CONCLUSIONS:Vessel healing involves both outward remodeling and neointimal overgrowth. Judicial oversizing could be useful in specific settings to counter the reduction in lumen diameter due to postimplant neointimal overgrowth; however, this overszing needs to be balanced against the decrease in metal coverage accompanying the use of oversized devices. Similar analysis for other devices is essential.
PMCID:11286005
PMID: 38663989
ISSN: 1936-959x
CID: 5697632

Venous Anatomy of the Central Nervous System

Shapiro, Maksim; Chung, Charlotte; Sharashidze, Vera; Nossek, Erez; Nelson, Peter Kim; Raz, Eytan
Comprehensive understanding of venous anatomy is a key factor in the approach to a multitude of conditions. Moreover, the venous system has become the center of attention as a new frontier for treatment of diseases such as idiopathic intracranial hypertension (IIH), arteriovenous malformation (AVM), pulsatile tinnitus, hydrocephalus, and cerebrospinal fluid (CSF) venous fistulas. Its knowledge is ever more an essential requirement of the modern brain physician. In this article, the authors explore the descriptive and functional anatomy of the venous system of the CNS in 5 subsections: embryology, dural sinuses, cortical veins, deep veins, and spinal veins.
PMID: 38782520
ISSN: 1558-1349
CID: 5654992

Spinal dural and epidural fistulas: role of cone beam CT in diagnosis and treatment

Shapiro, Maksim; Nossek, Erez; Sharashidze, Vera; Tanaka, Michihiro; Rutledge, Caleb; Chung, Charlotte; Khawaja, Ayaz; Riina, Howard; Nelson, Peter Kim; Raz, Eytan
Understanding normal spinal arterial and venous anatomy, and spinal vascular disease, is impossible without flow-based methods. Development of practical spinal angiography led to site-specific categorization of spinal vascular conditions, defined by the 'seat of disease' in relation to the cord and its covers. This enabled identification of targets for highly successful surgical and endovascular treatments, and guided interpretation of later cross-sectional imaging.Spinal dural and epidural arteriovenous fistulas represent the most common types of spinal shunts. Although etiology is debated, anatomy provides excellent pathophysiologic correlation. A spectrum of fistulas, from foramen magnum to the sacrum, is now well-characterized.Most recently, use of cone beam CT angiography has yielded new insights into normal and pathologic anatomy, including venous outflow. It provides unrivaled visualization of the fistula and its relationship with spinal cord vessels, and is the first practical method to study normal and pathologic spinal veins in vivo-with multiple implications for both safety and efficacy of treatments. We advocate consistent use of cone beam CT imaging in modern spinal fistula evaluation.The role of open surgery is likely to remain undiminished, with increasing availability and use of hybrid operating rooms for practical intraoperative angiography enhancing safety and efficacy of complex surgery.
PMID: 37673678
ISSN: 1759-8486
CID: 5653862

SuperDyna: Unlocking the Potential of Post-Treatment Device Evaluation

Raz, Eytan; Sharashidze, Vera; Nossek, Erez; Sahlein, Daniel H; Rostanski, Sara; Chung, Charlotte Y; Khawaja, Ayaz Mahmood; Nelson, Peter Kim; Shapiro, Maksim
BACKGROUND:Current imaging algorithms for post-device evaluation are limited by either poor representation of the device or poor delineation of the treated vessel. Combining the high-resolution images from a traditional three-dimensional digital subtraction angiography (3D-DSA) protocol with the longer cone-beam computed tomography (CBCT) protocol may provide simultaneous visualization of both the device and the vessel content in a single volume, improving the accuracy and detail of the assessment. We aim here to review our use of this technique which we termed "SuperDyna". METHODS:In this retrospective study, patients who underwent an endovascular procedure between February 2022 and January 2023 were identified. We analyzed patients who had both non-contrast CBCT and 3D-DSA post-treatment and collected information on pre-/post-blood urea nitrogen, creatinine, radiation dose, and the intervention type. RESULTS:In 1 year, SuperDyna was performed in 52 (of 1935, 2.6%) patients, of which 72% were women, median age 60 years. The most common reason for the addition of the SuperDyna was for post-flow diversion assessment (n=39). Renal function tests showed no changes. The average total procedure radiation dose was 2.8 Gy, with 4% dose and ~20 mL of contrast attributed to the additional 3D-DSA needed to generate the SuperDyna. CONCLUSIONS:The SuperDyna is a fusion imaging method that combines high-resolution CBCT and contrasted 3D-DSA to evaluate intracranial vasculature post-treatment. It allows for more comprehensive evaluation of the device position and apposition, aiding in treatment planning and patient education.
PMID: 37316194
ISSN: 1759-8486
CID: 5726142

Dual Layer vs Single Layer Woven EndoBridge Device in the Treatment of Intracranial Aneurysms: A Propensity Score-Matched Analysis

Dmytriw, Adam A; Salim, Hamza; Musmar, Basel; Aslan, Assala; Cancelliere, Nicole M; McLellan, Rachel M; Algin, Oktay; Ghozy, Sherief; Dibas, Mahmoud; Lay, Sovann V; Guenego, Adrien; Renieri, Leonardo; Carnevale, Joseph; Saliou, Guillaume; Mastorakos, Panagiotis; Naamani, Kareem El; Shotar, Eimad; Premat, Kevin; Möhlenbruch, Markus; Kral, Michael; Doron, Omer; Chung, Charlotte; Salem, Mohamed M; Lylyk, Ivan; Foreman, Paul M; Vachhani, Jay A; Shaikh, Hamza; Župančić, Vedran; Hafeez, Muhammad U; Catapano, Joshua; Waqas, Muhammad; Tutino, Vincent M; Ibrahim, Mohamed K; Mohammed, Marwa A; Imamoglu, Cetin; Bayrak, Ahmet; Rabinov, James D; Ren, Yifan; Schirmer, Clemens M; Piano, Mariangela; Kühn, Anna L; Michelozzi, Caterina; Elens, Stéphanie; Starke, Robert M; Hassan, Ameer E; Ogilvie, Mark; Sporns, Peter; Jones, Jesse; Brinjikji, Waleed; Nawka, Marie T; Psychogios, Marios; Ulfert, Christian; Diestro, Jose Danilo Bengzon; Pukenas, Bryan; Burkhardt, Jan-Karl; Huynh, Thien; Martinez-Gutierrez, Juan Carlos; Essibayi, Muhammed Amir; Sheth, Sunil A; Spiegel, Gary; Tawk, Rabih; Lubicz, Boris; Panni, Pietro; Puri, Ajit S; Pero, Guglielmo; Nossek, Erez; Raz, Eytan; Killer-Oberfalzer, Monika; Griessenauer, Christoph J; Asadi, Hamed; Siddiqui, Adnan; Brook, Allan L; Altschul, David; Ducruet, Andrew F; Albuquerque, Felipe C; Regenhardt, Robert W; Stapleton, Christopher J; Kan, Peter; Kalousek, Vladimir; Lylyk, Pedro; Boddu, Srikanth; Knopman, Jared; Aziz-Sultan, Mohammad A; Tjoumakaris, Stavropoula I; Clarençon, Frédéric; Limbucci, Nicola; Cuellar-Saenz, Hugo H; Jabbour, Pascal M; Pereira, Vitor Mendes; Patel, Aman B; Adeeb, Nimer
BACKGROUND:The Woven EndoBridge (WEB) devices have been used for treating wide neck bifurcation aneurysms (WNBAs) with several generational enhancements to improve clinical outcomes. The original device dual-layer (WEB DL) was replaced by a single-layer (WEB SL) device in 2013. This study aimed to compare the effectiveness and safety of these devices in managing intracranial aneurysms. METHODS:A multicenter cohort study was conducted, and data from 1,289 patients with intracranial aneurysms treated with either the WEB SL or WEB DL devices were retrospectively analyzed. Propensity score matching was utilized to balance the baseline characteristics between the two groups. Outcomes assessed included immediate occlusion rate, complete occlusion at last follow-up, retreatment rate, device compaction, and aneurysmal rupture. RESULTS:Before propensity score matching, patients treated with the WEB SL had a significantly higher rate of complete occlusion at the last follow-up and a lower rate of retreatment. After matching, there was no significant difference in immediate occlusion rate, retreatment rate, or device compaction between the WEB SL and DL groups. However, the SL group maintained a higher rate of complete occlusion at the final follow-up. Regression analysis showed that SL was associated with higher rates of complete occlusion (OR: 0.19; CI: 0.04 to 0.8, p = 0.029) and lower rates of retreatment (OR: 0.12; CI: 0 to 4.12, p = 0.23). CONCLUSION/CONCLUSIONS:The WEB SL and DL devices demonstrated similar performances in immediate occlusion rates and retreatment requirements for intracranial aneurysms. The SL device showed a higher rate of complete occlusion at the final follow-up.
PMID: 38483647
ISSN: 1437-2320
CID: 5639822

Endoscopic Endonasal Approach for Direct Puncture Embolization of Cavernous Dural Arteriovenous Fistula: 2-Dimensional Operative Video

Sangwon, Karl L; Esparza, Rogelio; Sharashidze, Vera; Dastagirzada, Yosef; Shapiro, Maksim; Riina, Howard A; Lieberman, Seth; Pacione, Donato; Raz, Eytan; Nossek, Erez
PMID: 37831980
ISSN: 2332-4260
CID: 5604252

Effect of anesthetic strategies on distal stroke thrombectomy in the anterior and posterior cerebral artery

Meyer, Lukas; Stracke, Christian Paul; Broocks, Gabriel; Wallocha, Marta; Elsharkawy, Mohamed; Sporns, Peter B; Piechowiak, Eike I; Kaesmacher, Johannes; Maegerlein, Christian; Hernandez Petzsche, Moritz Roman; Zimmermann, Hanna; Naziri, Weis; Abdullayev, Nuran; Kabbasch, Christoph; Behme, Daniel; Thormann, Maximilian; Maus, Volker; Fischer, Sebastian; Möhlenbruch, Markus A; Weyland, Charlotte Sabine; Langner, Soenke; Ernst, Marielle; Jamous, Ala; Meila, Dan; Miszczuk, Milena; Siebert, Eberhard; Lowens, Stephan; Krause, Lars Udo; Yeo, Leonard Ll; Tan, Benjamin Y Q; Gopinathan, Anil; Gory, Benjamin; Galvan Fernandez, Jorge; Schüller Arteaga, Miguel; Navia, Pedro; Raz, Eytan; Shapiro, Maksim; Arnberg, Fabian; Zeleňák, Kamil; Martínez-Galdámez, Mario; Alexandrou, Maria; Kastrup, Andreas; Papanagiotou, Panagiotis; Dorn, Franziska; Kemmling, André; Psychogios, Marios-Nikos; Andersson, Tommy; Chapot, René; Fiehler, Jens; Hanning, Uta
BACKGROUND:Numerous questions regarding procedural details of distal stroke thrombectomy remain unanswered. This study assesses the effect of anesthetic strategies on procedural, clinical and safety outcomes following thrombectomy for distal medium vessel occlusions (DMVOs). METHODS:Patients with isolated DMVO stroke from the TOPMOST registry were analyzed with regard to anesthetic strategies (ie, conscious sedation (CS), local (LA) or general anesthesia (GA)). Occlusions were in the P2/P3 or A2-A4 segments of the posterior and anterior cerebral arteries (PCA and ACA), respectively. The primary endpoint was the rate of complete reperfusion (modified Thrombolysis in Cerebral Infarction score 3) and the secondary endpoint was the rate of modified Rankin Scale score 0-1. Safety endpoints were the occurrence of symptomatic intracranial hemorrhage and mortality. RESULTS:Overall, 233 patients were included. The median age was 75 years (range 64-82), 50.6% (n=118) were female, and the baseline National Institutes of Health Stroke Scale score was 8 (IQR 4-12). DMVOs were in the PCA in 59.7% (n=139) and in the ACA in 40.3% (n=94). Thrombectomy was performed under LA±CS (51.1%, n=119) and GA (48.9%, n=114). Complete reperfusion was reached in 73.9% (n=88) and 71.9% (n=82) in the LA±CS and GA groups, respectively (P=0.729). In subgroup analysis, thrombectomy for ACA DMVO favored GA over LA±CS (aOR 3.07, 95% CI 1.24 to 7.57, P=0.015). Rates of secondary and safety outcomes were similar in the LA±CS and GA groups. CONCLUSION/CONCLUSIONS:LA±CS compared with GA resulted in similar reperfusion rates after thrombectomy for DMVO stroke of the ACA and PCA. GA may facilitate achieving complete reperfusion in DMVO stroke of the ACA. Safety and functional long-term outcomes were comparable in both groups.
PMID: 37142393
ISSN: 1759-8486
CID: 5509162