Searched for: in-biosketch:true
person:moyl02
The Economic Impact of AI on Breast Imaging
Smetherman, Dana; Golding, Lauren; Moy, Linda; Rubin, Eric
ISI:000768463900001
ISSN: 2631-6110
CID: 5182112
Reducing False-Positive Biopsies using Deep Neural Networks that Utilize both Local and Global Image Context of Screening Mammograms
Wu, Nan; Huang, Zhe; Shen, Yiqiu; Park, Jungkyu; Phang, Jason; Makino, Taro; Gene Kim, S; Cho, Kyunghyun; Heacock, Laura; Moy, Linda; Geras, Krzysztof J
Breast cancer is the most common cancer in women, and hundreds of thousands of unnecessary biopsies are done around the world at a tremendous cost. It is crucial to reduce the rate of biopsies that turn out to be benign tissue. In this study, we build deep neural networks (DNNs) to classify biopsied lesions as being either malignant or benign, with the goal of using these networks as second readers serving radiologists to further reduce the number of false-positive findings. We enhance the performance of DNNs that are trained to learn from small image patches by integrating global context provided in the form of saliency maps learned from the entire image into their reasoning, similar to how radiologists consider global context when evaluating areas of interest. Our experiments are conducted on a dataset of 229,426 screening mammography examinations from 141,473 patients. We achieve an AUC of 0.8 on a test set consisting of 464 benign and 136 malignant lesions.
PMID: 34731338
ISSN: 1618-727x
CID: 5038152
ACR Appropriateness Criteria® Transgender Breast Cancer Screening
Brown, Ann; Lourenco, Ana P; Niell, Bethany L; Cronin, Beth; Dibble, Elizabeth H; DiNome, Maggie L; Goel, Mita Sanghavi; Hansen, Juliana; Heller, Samantha L; Jochelson, Maxine S; Karrington, Baer; Klein, Katherine A; Mehta, Tejas S; Newell, Mary S; Schechter, Loren; Stuckey, Ashley R; Swain, Mary E; Tseng, Jennifer; Tuscano, Daymen S; Moy, Linda
Breast cancer screening recommendations for transgender and gender nonconforming individuals are based on the sex assigned at birth, risk factors, and use of exogenous hormones. Insufficient evidence exists to determine whether transgender people undergoing hormone therapy have an overall lower, average, or higher risk of developing breast cancer compared to birth-sex controls. Furthermore, there are no longitudinal studies evaluating the efficacy of breast cancer screening in the transgender population. In the absence of definitive data, current evidence is based on data extrapolated from cisgender studies and a limited number of cohort studies and case reports published on the transgender community. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.
PMID: 34794604
ISSN: 1558-349x
CID: 5049562
ACR Appropriateness Criteria® Supplemental Breast Cancer Screening Based on Breast Density
Weinstein, Susan P; Slanetz, Priscilla J; Lewin, Alana A; Battaglia, Tracy; Chagpar, Anees B; Dayaratna, Sandra; Dibble, Elizabeth H; Goel, Mita Sanghavi; Hayward, Jessica H; Kubicky, Charlotte D; Le-Petross, Huong T; Newell, Mary S; Sanford, Matthew F; Scheel, John R; Vincoff, Nina S; Yao, Katherine; Moy, Linda
Mammography remains the only validated screening tool for breast cancer, however, there are limitations to mammography. One of the limitations of mammography is the variable sensitivity based on breast density. Supplemental screening may be considered based on the patient's risk level and breast density. For average-risk women with nondense breasts, the sensitivity of digital breast tomosynthesis (DBT) screening is high; additional supplemental screening is not warranted in this population. For average-risk women with dense breasts, given the decreased sensitivity of mammography/DBT, this population may benefit from additional supplemental screening with contrast-enhanced mammography, screening ultrasound (US), breast MRI, or abbreviated breast MRI. In intermediate-risk women, there is emerging evidence suggesting that women in this population may benefit from breast MRI or abbreviated breast MRI. In intermediate-risk women with dense breasts, given the decreased sensitivity of mammography/DBT, this population may benefit from additional supplemental screening with contrast-enhancedmammography or screening US. There is strong evidence supporting screening high-risk women with breast MRI regardless of breast density. Contrast-enhanced mammography, whole breast screening US, or abbreviated breast MRI may be also considered. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.
PMID: 34794600
ISSN: 1558-349x
CID: 5049552
Artificial intelligence system reduces false-positive findings in the interpretation of breast ultrasound exams
Shen, Yiqiu; Shamout, Farah E; Oliver, Jamie R; Witowski, Jan; Kannan, Kawshik; Park, Jungkyu; Wu, Nan; Huddleston, Connor; Wolfson, Stacey; Millet, Alexandra; Ehrenpreis, Robin; Awal, Divya; Tyma, Cathy; Samreen, Naziya; Gao, Yiming; Chhor, Chloe; Gandhi, Stacey; Lee, Cindy; Kumari-Subaiya, Sheila; Leonard, Cindy; Mohammed, Reyhan; Moczulski, Christopher; Altabet, Jaime; Babb, James; Lewin, Alana; Reig, Beatriu; Moy, Linda; Heacock, Laura; Geras, Krzysztof J
Though consistently shown to detect mammographically occult cancers, breast ultrasound has been noted to have high false-positive rates. In this work, we present an AI system that achieves radiologist-level accuracy in identifying breast cancer in ultrasound images. Developed on 288,767 exams, consisting of 5,442,907 B-mode and Color Doppler images, the AI achieves an area under the receiver operating characteristic curve (AUROC) of 0.976 on a test set consisting of 44,755 exams. In a retrospective reader study, the AI achieves a higher AUROC than the average of ten board-certified breast radiologists (AUROC: 0.962 AI, 0.924 ± 0.02 radiologists). With the help of the AI, radiologists decrease their false positive rates by 37.3% and reduce requested biopsies by 27.8%, while maintaining the same level of sensitivity. This highlights the potential of AI in improving the accuracy, consistency, and efficiency of breast ultrasound diagnosis.
PMCID:8463596
PMID: 34561440
ISSN: 2041-1723
CID: 5039442
Diffusion weighted imaging for evaluation of breast lesions: Comparison between high b-value single-shot and routine readout-segmented sequences at 3Â T
Sanderink, Wendelien B G; Teuwen, Jonas; Appelman, Linda; Moy, Linda; Heacock, Laura; Weiland, Elisabeth; Sechopoulos, Ioannis; Mann, Ritse M
PURPOSE/OBJECTIVE:on image quality, lesion visibility and evaluation time. METHOD/METHODS:) method. Statistical analysis was performed in SPSS, with McNemar tests, and paired t-tests used for comparison. RESULTS:: 0.534, p = 0.336) scores. Lesion characteristics (e.g benign and high-risk, versus malignant; small (≤10 mm) vs. larger (>10 mm)) did not result in different image quality or lesion visibility between sequences. Sensitivity (rs-EPI: 72.2% vs. ss-EPImIRBS: 78.5%, p = 0.108) and specificity (70.5% vs. 56.8%, p = 0.210, respectively) were comparable. In both sequences the mean ADC value was higher for benign and high-risk lesions than for malignant lesions (ss-EPI-mIRBS: p = 0.022 and rs-EPI: p = 0.055). On average, ss-EPI-mIRBS resulted in decreased overall reading time by 7.7 s/case (p = 0.067); a reduction of 17%. For malignant lesions, average reading time was significantly shorter using ss-EPI-mIRBS compared to rs-EPI (64.0 s/lesion vs. 75.9 s/lesion, respectively, p = 0.039). CONCLUSION/CONCLUSIONS:enables for a mIRBS acquisition with quality and lesion conspicuity that is comparable to conventional rs-EPI, but with a decreased reading time.
PMID: 34560230
ISSN: 1873-5894
CID: 5012682
Breast Cancer Screening Recommendations Inclusive of All Women at Average Risk: Update from the ACR and Society of Breast Imaging
Monticciolo, Debra L; Malak, Sharp F; Friedewald, Sarah M; Eby, Peter R; Newell, Mary S; Moy, Linda; Destounis, Stamatia; Leung, Jessica W T; Hendrick, R Edward; Smetherman, Dana
Breast cancer remains the most common nonskin cancer, the second leading cause of cancer deaths, and the leading cause of premature death in US women. Mammography screening has been proven effective in reducing breast cancer deaths in women age 40 years and older. A mortality reduction of 40% is possible with regular screening. Treatment advances cannot overcome the disadvantage of being diagnosed with an advanced-stage tumor. The ACR and Society of Breast Imaging recommend annual mammography screening beginning at age 40, which provides the greatest mortality reduction, diagnosis at earlier stage, better surgical options, and more effective chemotherapy. Annual screening results in more screening-detected tumors, tumors of smaller sizes, and fewer interval cancers than longer screening intervals. Screened women in their 40s are more likely to have early-stage disease, negative lymph nodes, and smaller tumors than unscreened women. Delaying screening until age 45 or 50 will result in an unnecessary loss of life to breast cancer and adversely affects minority women in particular. Screening should continue past age 74 years, without an upper age limit unless severe comorbidities limit life expectancy. Benefits of screening should be considered along with the possibilities of recall for additional imaging and benign biopsy and the less tangible risks of anxiety and overdiagnosis. Although recall and biopsy recommendations are higher with more frequent screening, so are life-years gained and breast cancer deaths averted. Women who wish to maximize benefit will choose annual screening starting at age 40 years and will not stop screening prematurely.
PMID: 34154984
ISSN: 1558-349x
CID: 4933952
Lessons from the first DBTex Challenge
Park, Jungkyu; Shoshan, Yoel; Marti, Robert; Gómez del Campo, Pablo; Ratner, Vadim; Khapun, Daniel; Zlotnick, Aviad; Barkan, Ella; Gilboa-Solomon, Flora; Chłędowski, Jakub; Witowski, Jan; Millet, Alexandra; Kim, Eric; Lewin, Alana; Pysarenko, Kristine; Chen, Sardius; Goldberg, Julia; Patel, Shalin; Plaunova, Anastasia; Wegener, Melanie; Wolfson, Stacey; Lee, Jiyon; Hava, Sana; Murthy, Sindhoora; Du, Linda; Gaddam, Sushma; Parikh, Ujas; Heacock, Laura; Moy, Linda; Reig, Beatriu; Rosen-Zvi, Michal; Geras, Krzysztof J.
SCOPUS:85111105102
ISSN: 2522-5839
CID: 5000532
Bilateral gradient-echo spectroscopic imaging with correction of frequency variations for measurement of fatty acid composition in mammary adipose tissue
Baboli, Mehran; Storey, Pippa; Sood, Terlika Pandit; Fogarty, Justin; Moccaldi, Melanie; Lewin, Alana; Moy, Linda; Kim, Sungheon Gene
PURPOSE/OBJECTIVE:To develop a simultaneous dual-slab three-dimensional gradient-echo spectroscopic imaging (GSI) technique with frequency drift compensation for rapid (<6 min) bilateral measurement of fatty acid composition (FAC) in mammary adipose tissue. METHODS:A bilateral GSI sequence was developed using a simultaneous dual-slab excitation followed by 128 monopolar echoes. A short train of navigator echoes without phase or partition encoding was included at the beginning of each pulse repetition time period to correct for frequency variation caused by respiration and heating of the cryostat. Voxel-wise spectral fitting was applied to measure the areas of the lipid spectral peaks to estimate the number of double-bond (ndb), number of methylene-interrupted double-bond (nmidb), and chain length (cl). The proposed method was tested in an oil phantom and 10 postmenopausal women to assess the influence of the frequency variation on FAC estimation. RESULTS:The frequency drift observed over 5:27 min during the phantom scan was about 10 Hz. Phase correction based on the navigator reduced the median error of ndb, nmidb, and cl from 9.7%, 17.6%, and 3.2% to 2.1%, 9.5%, and 2.8%, respectively. The in vivo data showed a mean ± standard deviation frequency drift of 17.4 ± 2.5 Hz, with ripples at 0.3 ± 0.1 Hz. Our reconstruction algorithm successfully separated signals from the left and right breasts with negligible residual aliasing. Phase correction reduced the interquartile range within each subject's adipose tissue of ndb, nmidb, and cl by 18.4 ± 10.6%, 18.5 ± 13.9%, and 18.4 ± 10.6%, respectively. CONCLUSION/CONCLUSIONS:This study shows the feasibility of obtaining bilateral spectroscopic imaging data in the breast and that incorporation of a frequency navigator improves the estimation of FAC.
PMID: 33533056
ISSN: 1522-2594
CID: 4788292
Radiologist Characteristics Associated with Interpretive Performance of Screening Mammography: A National Mammography Database (NMD) Study
Lee, Cindy S; Moy, Linda; Hughes, Danny; Golden, Dan; Bhargavan-Chatfield, Mythreyi; Hemingway, Jennifer; Geras, Agnieszka; Duszak, Richard; Rosenkrantz, Andrew B
Background Factors affecting radiologists' performance in screening mammography interpretation remain poorly understood. Purpose To identify radiologists characteristics that affect screening mammography interpretation performance. Materials and Methods This retrospective study included 1223 radiologists in the National Mammography Database (NMD) from 2008 to 2019 who could be linked to Centers for Medicare & Medicaid Services (CMS) datasets. NMD screening performance metrics were extracted. Acceptable ranges were defined as follows: recall rate (RR) between 5% and 12%; cancer detection rate (CDR) of at least 2.5 per 1000 screening examinations; positive predictive value of recall (PPV1) between 3% and 8%; positive predictive value of biopsies recommended (PPV2) between 20% and 40%; positive predictive value of biopsies performed (PPV3) between the 25th and 75th percentile of study sample; invasive CDR of at least the 25th percentile of the study sample; and percentage of ductal carcinoma in situ (DCIS) of at least the 25th percentile of the study sample. Radiologist characteristics extracted from CMS datasets included demographics, subspecialization, and clinical practice patterns. Multivariable stepwise logistic regression models were performed to identify characteristics independently associated with acceptable performance for the seven metrics. The most influential characteristics were defined as those independently associated with the majority of the metrics (at least four). Results Relative to radiologists practicing in the Northeast, those in the Midwest were more likely to achieve acceptable RR, PPV1, PPV2, and CDR (odds ratio [OR], 1.4-2.5); those practicing in the West were more likely to achieve acceptable RR, PPV2, and PPV3 (OR, 1.7-2.1) but less likely to achieve acceptable invasive CDR (OR, 0.6). Relative to general radiologists, breast imagers were more likely to achieve acceptable PPV1, invasive CDR, percentage DCIS, and CDR (OR, 1.4-4.4). Those performing diagnostic mammography were more likely to achieve acceptable PPV1, PPV2, PPV3, invasive CDR, and CDR (OR, 1.9-2.9). Those performing breast US were less likely to achieve acceptable PPV1, PPV2, percentage DCIS, and CDR (OR, 0.5-0.7). Conclusion The geographic location of the radiology practice, subspecialization in breast imaging, and performance of diagnostic mammography are associated with better screening mammography performance; performance of breast US is associated with lower performance. ©RSNA, 2021 Online supplemental material is available for this article.
PMID: 34156300
ISSN: 1527-1315
CID: 4918312