Try a new search

Format these results:

Searched for:

in-biosketch:true

person:moyl02

Total Results:

245


ACR Appropriateness Criteria® Transgender Breast Cancer Screening

Brown, Ann; Lourenco, Ana P; Niell, Bethany L; Cronin, Beth; Dibble, Elizabeth H; DiNome, Maggie L; Goel, Mita Sanghavi; Hansen, Juliana; Heller, Samantha L; Jochelson, Maxine S; Karrington, Baer; Klein, Katherine A; Mehta, Tejas S; Newell, Mary S; Schechter, Loren; Stuckey, Ashley R; Swain, Mary E; Tseng, Jennifer; Tuscano, Daymen S; Moy, Linda
Breast cancer screening recommendations for transgender and gender nonconforming individuals are based on the sex assigned at birth, risk factors, and use of exogenous hormones. Insufficient evidence exists to determine whether transgender people undergoing hormone therapy have an overall lower, average, or higher risk of developing breast cancer compared to birth-sex controls. Furthermore, there are no longitudinal studies evaluating the efficacy of breast cancer screening in the transgender population. In the absence of definitive data, current evidence is based on data extrapolated from cisgender studies and a limited number of cohort studies and case reports published on the transgender community. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.
PMID: 34794604
ISSN: 1558-349x
CID: 5049562

Artificial intelligence system reduces false-positive findings in the interpretation of breast ultrasound exams

Shen, Yiqiu; Shamout, Farah E; Oliver, Jamie R; Witowski, Jan; Kannan, Kawshik; Park, Jungkyu; Wu, Nan; Huddleston, Connor; Wolfson, Stacey; Millet, Alexandra; Ehrenpreis, Robin; Awal, Divya; Tyma, Cathy; Samreen, Naziya; Gao, Yiming; Chhor, Chloe; Gandhi, Stacey; Lee, Cindy; Kumari-Subaiya, Sheila; Leonard, Cindy; Mohammed, Reyhan; Moczulski, Christopher; Altabet, Jaime; Babb, James; Lewin, Alana; Reig, Beatriu; Moy, Linda; Heacock, Laura; Geras, Krzysztof J
Though consistently shown to detect mammographically occult cancers, breast ultrasound has been noted to have high false-positive rates. In this work, we present an AI system that achieves radiologist-level accuracy in identifying breast cancer in ultrasound images. Developed on 288,767 exams, consisting of 5,442,907 B-mode and Color Doppler images, the AI achieves an area under the receiver operating characteristic curve (AUROC) of 0.976 on a test set consisting of 44,755 exams. In a retrospective reader study, the AI achieves a higher AUROC than the average of ten board-certified breast radiologists (AUROC: 0.962 AI, 0.924 ± 0.02 radiologists). With the help of the AI, radiologists decrease their false positive rates by 37.3% and reduce requested biopsies by 27.8%, while maintaining the same level of sensitivity. This highlights the potential of AI in improving the accuracy, consistency, and efficiency of breast ultrasound diagnosis.
PMCID:8463596
PMID: 34561440
ISSN: 2041-1723
CID: 5039442

Diffusion weighted imaging for evaluation of breast lesions: Comparison between high b-value single-shot and routine readout-segmented sequences at 3 T

Sanderink, Wendelien B G; Teuwen, Jonas; Appelman, Linda; Moy, Linda; Heacock, Laura; Weiland, Elisabeth; Sechopoulos, Ioannis; Mann, Ritse M
PURPOSE/OBJECTIVE:on image quality, lesion visibility and evaluation time. METHOD/METHODS:) method. Statistical analysis was performed in SPSS, with McNemar tests, and paired t-tests used for comparison. RESULTS:: 0.534, p = 0.336) scores. Lesion characteristics (e.g benign and high-risk, versus malignant; small (≤10 mm) vs. larger (>10 mm)) did not result in different image quality or lesion visibility between sequences. Sensitivity (rs-EPI: 72.2% vs. ss-EPImIRBS: 78.5%, p = 0.108) and specificity (70.5% vs. 56.8%, p = 0.210, respectively) were comparable. In both sequences the mean ADC value was higher for benign and high-risk lesions than for malignant lesions (ss-EPI-mIRBS: p = 0.022 and rs-EPI: p = 0.055). On average, ss-EPI-mIRBS resulted in decreased overall reading time by 7.7 s/case (p = 0.067); a reduction of 17%. For malignant lesions, average reading time was significantly shorter using ss-EPI-mIRBS compared to rs-EPI (64.0 s/lesion vs. 75.9 s/lesion, respectively, p = 0.039). CONCLUSION/CONCLUSIONS:enables for a mIRBS acquisition with quality and lesion conspicuity that is comparable to conventional rs-EPI, but with a decreased reading time.
PMID: 34560230
ISSN: 1873-5894
CID: 5012682

Breast Cancer Screening Recommendations Inclusive of All Women at Average Risk: Update from the ACR and Society of Breast Imaging

Monticciolo, Debra L; Malak, Sharp F; Friedewald, Sarah M; Eby, Peter R; Newell, Mary S; Moy, Linda; Destounis, Stamatia; Leung, Jessica W T; Hendrick, R Edward; Smetherman, Dana
Breast cancer remains the most common nonskin cancer, the second leading cause of cancer deaths, and the leading cause of premature death in US women. Mammography screening has been proven effective in reducing breast cancer deaths in women age 40 years and older. A mortality reduction of 40% is possible with regular screening. Treatment advances cannot overcome the disadvantage of being diagnosed with an advanced-stage tumor. The ACR and Society of Breast Imaging recommend annual mammography screening beginning at age 40, which provides the greatest mortality reduction, diagnosis at earlier stage, better surgical options, and more effective chemotherapy. Annual screening results in more screening-detected tumors, tumors of smaller sizes, and fewer interval cancers than longer screening intervals. Screened women in their 40s are more likely to have early-stage disease, negative lymph nodes, and smaller tumors than unscreened women. Delaying screening until age 45 or 50 will result in an unnecessary loss of life to breast cancer and adversely affects minority women in particular. Screening should continue past age 74 years, without an upper age limit unless severe comorbidities limit life expectancy. Benefits of screening should be considered along with the possibilities of recall for additional imaging and benign biopsy and the less tangible risks of anxiety and overdiagnosis. Although recall and biopsy recommendations are higher with more frequent screening, so are life-years gained and breast cancer deaths averted. Women who wish to maximize benefit will choose annual screening starting at age 40 years and will not stop screening prematurely.
PMID: 34154984
ISSN: 1558-349x
CID: 4933952

Lessons from the first DBTex Challenge

Park, Jungkyu; Shoshan, Yoel; Marti, Robert; Gómez del Campo, Pablo; Ratner, Vadim; Khapun, Daniel; Zlotnick, Aviad; Barkan, Ella; Gilboa-Solomon, Flora; Chłędowski, Jakub; Witowski, Jan; Millet, Alexandra; Kim, Eric; Lewin, Alana; Pysarenko, Kristine; Chen, Sardius; Goldberg, Julia; Patel, Shalin; Plaunova, Anastasia; Wegener, Melanie; Wolfson, Stacey; Lee, Jiyon; Hava, Sana; Murthy, Sindhoora; Du, Linda; Gaddam, Sushma; Parikh, Ujas; Heacock, Laura; Moy, Linda; Reig, Beatriu; Rosen-Zvi, Michal; Geras, Krzysztof J.
SCOPUS:85111105102
ISSN: 2522-5839
CID: 5000532

Bilateral gradient-echo spectroscopic imaging with correction of frequency variations for measurement of fatty acid composition in mammary adipose tissue

Baboli, Mehran; Storey, Pippa; Sood, Terlika Pandit; Fogarty, Justin; Moccaldi, Melanie; Lewin, Alana; Moy, Linda; Kim, Sungheon Gene
PURPOSE/OBJECTIVE:To develop a simultaneous dual-slab three-dimensional gradient-echo spectroscopic imaging (GSI) technique with frequency drift compensation for rapid (<6 min) bilateral measurement of fatty acid composition (FAC) in mammary adipose tissue. METHODS:A bilateral GSI sequence was developed using a simultaneous dual-slab excitation followed by 128 monopolar echoes. A short train of navigator echoes without phase or partition encoding was included at the beginning of each pulse repetition time period to correct for frequency variation caused by respiration and heating of the cryostat. Voxel-wise spectral fitting was applied to measure the areas of the lipid spectral peaks to estimate the number of double-bond (ndb), number of methylene-interrupted double-bond (nmidb), and chain length (cl). The proposed method was tested in an oil phantom and 10 postmenopausal women to assess the influence of the frequency variation on FAC estimation. RESULTS:The frequency drift observed over 5:27 min during the phantom scan was about 10 Hz. Phase correction based on the navigator reduced the median error of ndb, nmidb, and cl from 9.7%, 17.6%, and 3.2% to 2.1%, 9.5%, and 2.8%, respectively. The in vivo data showed a mean ± standard deviation frequency drift of 17.4 ± 2.5 Hz, with ripples at 0.3 ± 0.1 Hz. Our reconstruction algorithm successfully separated signals from the left and right breasts with negligible residual aliasing. Phase correction reduced the interquartile range within each subject's adipose tissue of ndb, nmidb, and cl by 18.4 ± 10.6%, 18.5 ± 13.9%, and 18.4 ± 10.6%, respectively. CONCLUSION/CONCLUSIONS:This study shows the feasibility of obtaining bilateral spectroscopic imaging data in the breast and that incorporation of a frequency navigator improves the estimation of FAC.
PMID: 33533056
ISSN: 1522-2594
CID: 4788292

Radiologist Characteristics Associated with Interpretive Performance of Screening Mammography: A National Mammography Database (NMD) Study

Lee, Cindy S; Moy, Linda; Hughes, Danny; Golden, Dan; Bhargavan-Chatfield, Mythreyi; Hemingway, Jennifer; Geras, Agnieszka; Duszak, Richard; Rosenkrantz, Andrew B
Background Factors affecting radiologists' performance in screening mammography interpretation remain poorly understood. Purpose To identify radiologists characteristics that affect screening mammography interpretation performance. Materials and Methods This retrospective study included 1223 radiologists in the National Mammography Database (NMD) from 2008 to 2019 who could be linked to Centers for Medicare & Medicaid Services (CMS) datasets. NMD screening performance metrics were extracted. Acceptable ranges were defined as follows: recall rate (RR) between 5% and 12%; cancer detection rate (CDR) of at least 2.5 per 1000 screening examinations; positive predictive value of recall (PPV1) between 3% and 8%; positive predictive value of biopsies recommended (PPV2) between 20% and 40%; positive predictive value of biopsies performed (PPV3) between the 25th and 75th percentile of study sample; invasive CDR of at least the 25th percentile of the study sample; and percentage of ductal carcinoma in situ (DCIS) of at least the 25th percentile of the study sample. Radiologist characteristics extracted from CMS datasets included demographics, subspecialization, and clinical practice patterns. Multivariable stepwise logistic regression models were performed to identify characteristics independently associated with acceptable performance for the seven metrics. The most influential characteristics were defined as those independently associated with the majority of the metrics (at least four). Results Relative to radiologists practicing in the Northeast, those in the Midwest were more likely to achieve acceptable RR, PPV1, PPV2, and CDR (odds ratio [OR], 1.4-2.5); those practicing in the West were more likely to achieve acceptable RR, PPV2, and PPV3 (OR, 1.7-2.1) but less likely to achieve acceptable invasive CDR (OR, 0.6). Relative to general radiologists, breast imagers were more likely to achieve acceptable PPV1, invasive CDR, percentage DCIS, and CDR (OR, 1.4-4.4). Those performing diagnostic mammography were more likely to achieve acceptable PPV1, PPV2, PPV3, invasive CDR, and CDR (OR, 1.9-2.9). Those performing breast US were less likely to achieve acceptable PPV1, PPV2, percentage DCIS, and CDR (OR, 0.5-0.7). Conclusion The geographic location of the radiology practice, subspecialization in breast imaging, and performance of diagnostic mammography are associated with better screening mammography performance; performance of breast US is associated with lower performance. ©RSNA, 2021 Online supplemental material is available for this article.
PMID: 34156300
ISSN: 1527-1315
CID: 4918312

Digital Mammography Is Similar to Screen-Film Mammography for Women with Personal History of Breast Cancer [Comment]

Moy, Linda; Gao, Yiming
PMID: 34003061
ISSN: 1527-1315
CID: 4878682

Response to COVID-19 in breast imaging [Editorial]

Moy, L; Toth, H K; Newell, M S; Plecha, D; Leung, J W T; Harvey, J A
EMBASE:2010701196
ISSN: 2631-6129
CID: 4782242

Breast MRI for Evaluation of Response to Neoadjuvant Therapy

Reig, Beatriu; Lewin, Alana A; Du, Linda; Heacock, Laura; Toth, Hildegard K; Heller, Samantha L; Gao, Yiming; Moy, Linda
Neoadjuvant therapy is increasingly being used to treat early-stage triple-negative and human epidermal growth factor 2-overexpressing breast cancers, as well as locally advanced and inflammatory breast cancers. The rationales for neoadjuvant therapy are to shrink tumor size and potentially decrease the extent of surgery, to serve as an in vivo test of response to therapy, and to reveal prognostic information for the patient. MRI is the most accurate modality to demonstrate response to therapy and to help ensure accurate presurgical planning. Changes in lesion diameter, volume, and enhancement are used to predict complete response, partial response, or nonresponse to therapy. However, residual disease may be overestimated or underestimated at MRI. Fibrosis, necrotic tumors, and residual benign masses may be causes of overestimation of residual disease. Nonmass lesions, invasive lobular carcinoma, hormone receptor-positive tumors, nonconcentric shrinkage patterns, the use of antiangiogenic therapy, and late-enhancing foci may be causes of underestimation of residual disease. In patients with known axillary lymph node metastasis, neoadjuvant therapy may be followed by targeted axillary dissection to avoid the potential morbidity associated with an axillary lymph node dissection. Diffusion-weighted imaging, radiomics, machine learning, and deep learning methods are under investigation to improve MRI accuracy in predicting treatment response.©RSNA, 2021.
PMID: 33939542
ISSN: 1527-1323
CID: 4858892