Searched for: in-biosketch:true
person:attubm01
VENOUS CHANGES OCCURRING DURING THE VALSALVA MANEUVER - AN INTRAVASCULAR ULTRASOUND STUDY [Meeting Abstract]
ATTUBATO, MJ; KATZ, ES; FEIT, F; BERNSTEIN, N; SCHWARTZMAN, D; KRONZON, I
ISI:A1992JT66003484
ISSN: 0009-7322
CID: 51837
Safety and efficacy of a new regimen of intravenous recombinant tissue-type plasminogen activator potentially suitable for either prehospital or in-hospital administration
McKendall GR; Attubato MJ; Drew TM; Feit F; Sharaf BL; Thomas ES; Teichman S; McDonald MJ; Williams DO
The safety and efficacy of a new regimen of intravenous recombinant tissue-type plasminogen activator (rt-PA) potentially suitable for either pre- or in-hospital administration were assessed in 60 patients with acute myocardial infarction in an open label coronary angiographic study. The regimen consisted of a 20-mg bolus dose followed 30 min later by a delayed infusion of 80 mg over 2 h. This regimen was designed to facilitate prehospital administration of rt-PA. Infarct-related artery patency (Thrombolysis in Myocardial Infarction [TIMI] grade 2 or 3 flow) was observed in 40 of 53 patients at 60 min (75.5%, 95% confidence intervals [CI] 61% to 84%) and in 55 of 60 patients at 90 min (91.7%, 95% CI 80% to 95%) after the rt-PA bolus. By 90 min the majority of patients (55%) exhibited TIMI grade 3 flow; infarct artery patency at 120 min was 84.9%. During hospitalization definite recurrent ischemia occurred in nine patients (15%); nonfatal recurrent infarction was noted in one (1.7%). Four patients (6.7%) experienced major bleeding, including one with intracranial bleeding. There were seven deaths (11.7%). Mortality was significantly influenced by the occurrence of cardiogenic shock, which was present in five patients at the time of enrollment. Blood fibrinogen levels were obtained before and during rt-PA infusion. At baseline and 30 and 150 min after the bolus dose, the mean fibrinogen level (+/- SD) was 284.83 +/- 77.39, 237.96 +/- 76.92 and 192.04 +/- 57.82 mg/dl, respectively. Compared with the baseline value, there was a significant (p less than 0.05) decrease in fibrinogen at both 30 and 150 min.(ABSTRACT TRUNCATED AT 250 WORDS)
PMID: 1960329
ISSN: 0735-1097
CID: 37086
Left ventricle-to-ascending aorta communication complicating composite graft repair undetected by aortography: diagnosis by transesophageal echocardiography [Case Report]
Rosenzweig BP; Donahue T; Attubato M; Feit F; Kronzon I
A 57-year-old man underwent composite ascending aortic conduit and prosthetic aortic valve repair of a sinus of Valsalva aneurysm. The patient's course was complicated by recurrent aneurysm formation caused by a communication between the left ventricular outflow tract and the ascending aorta outside the conduit. Transesophageal echocardiography documented the anatomic and functional characteristics of this complication, whereas aortography failed to demonstrate them. Findings at surgery confirmed the transesophageal echocardiogram results of a left ventricular outflow tract to aorta communication, a normal prosthetic aortic valve, and an intact distal anastomosis of the conduit with the aorta. Transesophageal echocardiography is a useful modality for the evaluation of composite graft repairs of the aortic valve and ascending aorta
PMID: 1760189
ISSN: 0894-7317
CID: 13856
Multifaceted echocardiographic approach to the diagnosis of a ruptured sinus of Valsalva aneurysm [Case Report]
Katz ES; Cziner DG; Rosenzweig BP; Attubato M; Feit F; Kronzon I
PMID: 1742038
ISSN: 0894-7317
CID: 13927
A RANDOMIZED, PLACEBO-CONTROLLED, TRIAL OF TISSUE PLASMINOGEN- ACTIVATOR IN ELDERLY PATIENTS WITH ACUTE MYOCARDIAL-INFARCTION [Meeting Abstract]
Feit, F; Breed, J; Anderson, JL; Attubato, MJ; Davison, R; Sherrid, MV; Teichman, S
ISI:A1990EC76402654
ISSN: 0009-7322
CID: 31913
Percutaneous double-balloon valvuloplasty of porcine bioprosthetic valves in the tricuspid position [Case Report]
Attubato MJ; Stroh JA; Bach RG; Slater J; Feit F
This is a description of the first two reported cases of double-balloon valvuloplasty in the treatment of porcine bioprosthetic valve stenosis in the tricuspid position. In both cases, the double-balloon technique resulted in a better hemodynamic improvement than single-balloon valvuloplasty and was well tolerated. Double-balloon valvuloplasty is a reasonable alternative to surgical replacement of a stenotic bioprosthesis in the tricuspid position
PMID: 2364421
ISSN: 0098-6569
CID: 37088