Searched for: in-biosketch:true
person:daneb01
Test Characteristics of Cross-sectional Imaging and Concordance With Endoscopy in Postoperative Crohn's Disease
Bachour, Salam P; Shah, Ravi S; Lyu, Ruishen; Nakamura, Takahiro; Shen, Michael; Li, Terry; Dane, Bari; Barnes, Edward L; Rieder, Florian; Cohen, Benjamin; Qazi, Taha; Lashner, Bret; Achkar, Jean Paul; Philpott, Jessica; Holubar, Stefan D; Lightner, Amy L; Regueiro, Miguel; Axelrad, Jordan; Baker, Mark E; Click, Benjamin
BACKGROUND & AIMS/OBJECTIVE:Postoperative Crohn's disease (CD) surveillance relies on endoscopic monitoring. The role of cross-sectional imaging is less clear. We evaluated the concordance of cross-sectional enterography with endoscopic recurrence and the predictive ability of radiography for future CD postoperative recurrence. METHODS:We performed a multi-institution retrospective cohort study of postoperative adult patients with CD who underwent ileocolonoscopy and cross-sectional enterography within 90 days of each other following ileocecal resection. Imaging studies were interpreted by blinded, expert CD radiologists. Patients were categorized by presence of endoscopic postoperative recurrence (E+) (modified Rutgeerts' score ≥i2b) or radiographic disease activity (R+) and grouped by concordance status. RESULTS:A total of 216 patients with CD with paired ileocolonoscopy and imaging were included. A majority (54.2%) exhibited concordance (34.7% E+/R+; 19.4% E-/R-) between studies. The plurality (41.7%; n = 90) were E-/R+ discordant. Imaging was highly sensitive (89.3%), with low specificity (31.8%), in detecting endoscopic postoperative recurrence. Intestinal wall thickening, luminal narrowing, mural hyper-enhancement, and length of disease on imaging were associated with endoscopic recurrence (all P < .01). Radiographic disease severity was associated with increasing Rutgeerts' score (P < .001). E-/R+ patients experienced more rapid subsequent endoscopic recurrence (hazard ratio, 4.16; P = .033) and increased rates of subsequent endoscopic (43.8% vs 22.7%) and surgical recurrence (20% vs 9.5%) than E-/R- patients (median follow-up, 4.5 years). CONCLUSIONS:Cross-sectional imaging is highly sensitive, but poorly specific, in detecting endoscopic disease activity and postoperative recurrence. Advanced radiographic disease correlates with endoscopic severity. Patients with radiographic activity in the absence of endoscopic recurrence may be at increased risk for future recurrence, and closer monitoring should be considered.
PMID: 34968729
ISSN: 1542-7714
CID: 5232522
Current and Emerging Approaches to the Diagnosis and Treatment of Crohn's Disease Strictures
Lee, Briton; Dane, Bari; Katz, Seymour
The management and understanding of Crohn's disease (CD) continues to evolve quickly. Intestinal strictures were previously thought to be an inevitable result of irreversible fibrosis caused by chronic inflammation. However, increased understanding of the dynamic nature of strictures and of the pathophysiology of this condition has highlighted emerging targets for potential treatment. In the diagnosis of strictures, a distinction must be made between inflammatory and fibrotic types, as the former may respond to medical therapy. Emerging technologies, such as dual-energy computed tomography enterography and iodine density, have allowed more accurate characterization of strictures. Surgical and endoscopic treatment remains the mainstay for fibrotic strictures, but developments in systemic and intralesional biologic therapy have shown efficacy. This article reviews the pathophysiology of this debilitating complication of CD as well as current and emerging diagnostics and treatments.
PMCID:9053491
PMID: 35505943
ISSN: 1554-7914
CID: 5216152
American College of Radiology ACR Appropriateness Criteria Right Lower Quadrant Pain
Kambadakone, Avinash R; Santillan, Cynthia S; Kim, David H; Fowler, Kathryn J; Birkolz, James H; Camacho, Marc A; Cash, Brooks D; Dane, Bari; Felker, Robin A; Grossman, Eric J; Korngold, Elena K; Liu, Peter S; Marin, Daniele; McCrary, Marion; Pietryga, Jason A; Weinstein, Stefanie; Zukotynski, Katherine; Carucci, Laura R
[S.l. : American College of Radiology], 2022
Extent: 19 p.
ISBN: n/a
CID: 5202162
Association of body composition parameters measured on CT with risk of hospitalization in patients with Covid-19
Chandarana, Hersh; Pisuchpen, Nisanard; Krieger, Rachel; Dane, Bari; Mikheev, Artem; Feng, Yang; Kambadakone, Avinash; Rusinek, Henry
PURPOSE/OBJECTIVE:To assess prognostic value of body composition parameters measured at CT to predict risk of hospitalization in patients with COVID-19 infection. METHODS:177 patients with SARS-CoV-2 infection and with abdominopelvic CT were included in this retrospective IRB approved two-institution study. Patients were stratified based on disease severity as outpatients (no hospital admission) and patients who were hospitalized (inpatients). Two readers blinded to the clinical outcome segmented axial CT images at the L3 vertebral body level for visceral adipose tissue (VAT), subcutaneous adipose tissue (SAT), muscle adipose tissue (MAT), muscle mass (MM). VAT to total adipose tissue ratio (VAT/TAT), MAT/MM ratio, and muscle index (MI) at L3 were computed. These measures, along with detailed clinical risk factors, were compared in patients stratified by severity. Various logistic regression clinical and clinical + imaging models were compared to discriminate inpatients from outpatients. RESULTS:There were 76 outpatients (43%) and 101 inpatients. Male gender (p = 0.013), age (p = 0.0003), hypertension (p = 0.0003), diabetes (p = 0.0001), history of cardiac disease (p = 0.007), VAT/TAT (p < 0.0001), and MAT/MM (p < 0.0001), but not BMI, were associated with hospitalization. A clinical model (age, gender, BMI) had AUC of 0.70. Addition of VAT/TAT to the clinical model improved the AUC to 0.73. Optimal model that included gender, BMI, race (Black), MI, VAT/TAT, as well as interaction between gender and VAT/TAT and gender and MAT/MM demonstrated the highest AUC of 0.83. CONCLUSION/CONCLUSIONS:MAT/MM and VAT/TAT provides important prognostic information in predicting patients with COVID-19 who are likely to require hospitalization.
PMCID:8592118
PMID: 34801878
ISSN: 1872-7727
CID: 5063182
Diagnostic abdominal MR imaging on a prototype low-field 0.55Â T scanner operating at two different gradient strengths
Chandarana, Hersh; Bagga, Barun; Huang, Chenchan; Dane, Bari; Petrocelli, Robert; Bruno, Mary; Keerthivasan, Mahesh; Grodzki, David; Block, Kai Tobias; Stoffel, David; Sodickson, Daniel K
PURPOSE:To develop a protocol for abdominal imaging on a prototype 0.55 T scanner and to benchmark the image quality against conventional 1.5 T exam. METHODS:In this prospective IRB-approved HIPAA-compliant study, 10 healthy volunteers were recruited and imaged. A commercial MRI system was modified to operate at 0.55 T (LF) with two different gradient performance levels. Each subject underwent non-contrast abdominal examinations on the 0.55 T scanner utilizing higher gradients (LF-High), lower adjusted gradients (LF-Adjusted), and a conventional 1.5 T scanner. The following pulse sequences were optimized: fat-saturated T2-weighted imaging (T2WI), diffusion-weighted imaging (DWI), and Dixon T1-weighted imaging (T1WI). Three readers independently evaluated image quality in a blinded fashion on a 5-point Likert scale, with a score of 1 being non-diagnostic and 5 being excellent. An exact paired sample Wilcoxon signed-rank test was used to compare the image quality. RESULTS:Diagnostic image quality (overall image quality score ≥ 3) was achieved at LF in all subjects for T2WI, DWI, and T1WI with no more than one unit lower score than 1.5 T. The mean difference in overall image quality score was not significantly different between LF-High and LF-Adjusted for T2WI (95% CI - 0.44 to 0.44; p = 0.98), DWI (95% CI - 0.43 to 0.36; p = 0.92), and for T1 in- and out-of-phase imaging (95%C I - 0.36 to 0.27; p = 0.91) or T1 fat-sat (water only) images (95% CI - 0.24 to 0.18; p = 1.0). CONCLUSION:Diagnostic abdominal MRI can be performed on a prototype 0.55 T scanner, either with conventional or with reduced gradient performance, within an acquisition time of 10 min or less.
PMID: 34415411
ISSN: 2366-0058
CID: 5048652
Using Lung Base Covid-19 Findings to Predict Future Disease Trends and New Variant Outbreaks: Study of First New York City (NYC) Outbreak
Smereka, Paul; Anthopolos, Rebecca; Latson, Larry A; Kirsch, Polly; Dane, Bari
RATIONALE AND OBJECTIVES/OBJECTIVE:Asymptomatic COVID-19 carriers and insufficient testing make containment of the virus difficult. The purpose of this study was to determine if unexpected lung base findings on abdominopelvic CTs concerning for COVID-19 infection could serve as a surrogate for the diagnosis of COVID-19 in the community. MATERIALS AND METHODS/METHODS:A database search of abdominopelvic CT reports from March 1,2020 to May 2,2020 was performed for keywords suggesting COVID-19 infection by lung base findings. COVID-19 status, respiratory symptoms, laboratory parameters and patient outcomes (hospitalization, ICU admission and/or intubation, and death) were recorded. The trend in cases of unexpected concerning lung base findings on abdominopelvic CT at our institution was compared to the total number of confirmed new cases in NYC over the same time period. RESULTS:The trend in abnormal lung base findings on abdominopelvic CT at our institution correlated with the citywide number of confirmed new cases, including rise and subsequent fall in total cases. The trend was not mediated by COVID-19 testing status or number of tests performed. Patients with respiratory symptoms had significantly higher ferritin (median = 995ng/ml vs 500ng/ml, p = 0.027) and death rate (8/24, 33% vs 4/54, 9%, p = 0.018) compared to those without. CONCLUSION/CONCLUSIONS:The rise and fall of unexpected lung base findings suggestive of COVID-19 infection on abdominopelvic CT in patients without COVID-19 symptoms correlated with the number of confirmed new cases throughout NYC from the same time period. A model using abdominopelvic CT lung base findings can serve as a surrogate for future COVID-19 outbreaks.
PMID: 34740527
ISSN: 1878-4046
CID: 5038562
Feasibility of Abdominal Magnetic Resonance Imaging in Patients With Residual Concentrated Enteric Contrast After Fluoroscopic Abdominal Examination
Dane, Bari; Hindman, Nicole
OBJECTIVE:This study aimed to evaluate the image quality, image artifacts, radiologist confidence, and ability to provide definitive diagnosis for all patients with magnetic resonance imaging (MRI) performed after an abdominal fluoroscopic examination and to determine the utility of MRI in this setting. METHODS:Thirty-one MRI examinations performed a median of 2 days after fluoroscopic bowel evaluation (barium, n = 13; iodine, n = 18), 20 within 3 days of MRI, were retrospectively reviewed. The image quality, artifact emanating from bowel, inhomogeneity artifact, radiologist confidence, ability to render a definitive diagnosis, and identification of emergent or important findings for all MRI examinations were assessed. These same features were evaluated on 5 computed tomographies performed after fluoroscopy (before the MRI) in the same cohort. RESULTS:All 31 MRI examinations performed after fluoroscopic studies with concentrated barium or iodine solutions were diagnostic for answering the clinical question according to radiologist and report review, regardless of magnet strength and type of fluoroscopic contrast ingested. Magnetic resonance imaging after fluoroscopy had excellent overall image quality (mean score, 4.74/5), minimal to no artifact emanating from bowel (mean, 4.63/5), minimal inhomogeneity artifact (mean, 4.38/5), and excellent diagnostic confidence (mean, 4.98/5). No additional imaging was necessary for diagnosis after MRI. Computed tomography after fluoroscopy had lower overall image quality, more image artifacts, and lower diagnostic confidence (P < 0.05). CONCLUSIONS:Magnetic resonance imaging is a useful tool for evaluating patients with retained concentrated enteric contrast from recent fluoroscopic examinations. In the absence of contraindication, MRI should be considered in the evaluation of urgent clinical problems in patients who recently underwent a fluoroscopic bowel evaluation.
PMID: 34546677
ISSN: 1532-3145
CID: 5026822
Computed Tomography Enterography
Petrocelli, Robert; Dane, Bari
Computed tomography enterography (CTE) is an abdominopelvic computed tomography (CT) tailored for evaluation of the small bowel. This multidetector CT examination uses neutral oral contrast to optimally distend small bowel. Patients are scanned after the rapid injection of intravenous contrast during peak bowel wall enhancement. CTE is excellent for the evaluation of many small bowel disorders, particularly Crohn's disease. The purpose of this article is to review CTE indications, contraindications, technique, safety considerations, and imaging findings of common small bowel diseases.
SCOPUS:85114739334
ISSN: 1546-0843
CID: 5009252
Crohn Disease Active Inflammation Assessment with Iodine Density from Dual-Energy CT Enterography: Comparison with Histopathologic Analysis
Dane, Bari; Sarkar, Suparna; Nazarian, Matthew; Galitzer, Hayley; O'Donnell, Thomas; Remzi, Feza; Chang, Shannon; Megibow, Alec
Background Dual-energy CT enterography (DECTE) has been shown to be useful in characterizing Crohn disease activity compared with clinical markers of inflammation but, to the knowledge of the authors, comparison has not been made with histopathologic specimens. Purpose To compare mucosal iodine density obtained at DECTE from Crohn disease-affected bowel with histopathologic specimens from surgically resected ileocolectomy bowel segments or terminal ileum colonoscopic biopsies in the same patients. Materials and Methods This was a retrospective study. Bowel segments in adults with Crohn disease who underwent DECTE from January 2017 to April 2019 within 90 days of ileocolectomy or colonoscopy were retrospectively evaluated with prototype software allowing the semiautomatic determination of inner hyperdense bowel wall (mucosal) mean iodine density, normalized to the aorta. Mean normalized iodine density and clinical activity indexes (Crohn Disease Activity Index [CDAI] and Harvey-Bradshaw Index [HBI]) were compared with histologic active inflammation grades by using two-tailed t tests. Receiver operating characteristic curves were generated for mean normalized iodine density, CDAI, and HBI to determine sensitivity, specificity, and accuracy. A P value less than .05 was considered to indicate statistical significance. Results The following 16 patients were evaluated (mean age, 41 years ± 14 [standard deviation]): 10 patients (five men, five women; mean age, 41 years ± 15) with 19 surgical resection specimens and six patients with terminal ileum colonoscopic mucosal biopsies (four men, two women; mean age, 43 years ± 14). Mean normalized iodine density was 16.5% ± 5.7 for bowel segments with no active inflammation (n = 8) and 34.7% ± 9.7 for segments with any active inflammation (n = 17; P < .001). A 20% mean normalized iodine density threshold had sensitivity, specificity, and accuracy of 17 of 17 (100%; 95% CI: 80.5, 100), six of eight (75%; 95% CI: 35, 97), and 23 of 25 (92%; 95% CI: 74, 99), respectively, for active inflammation. Clinical indexes were similar for patients with and without active inflammation at histopathologic analysis (CDAI score, 261 vs 251, respectively [P = .77]; HBI score, 7.8 vs 6.4, respectively [P = .36]). Conclusion Iodine density from dual-energy CT enterography may be used as a radiologic marker of Crohn disease activity as correlated with histopathologic analysis. © RSNA, 2021 See also the editorial by Ohliger in this issue.
PMID: 34342502
ISSN: 1527-1315
CID: 4988602
Prediction of Patient Height and Weight With a 3-Dimensional Camera
Dane, Bari; Singh, Vivek; Nazarian, Matthew; O'Donnell, Thomas; Liu, Shu; Kapoor, Ankur; Megibow, Alec
OBJECTIVE:The aim of this study was to determine accuracy of height and weight prediction by a 3-dimensional (3D) camera. METHODS:A total of 453 patients whose computed tomography imaging used a 3D camera from December 19, 2018 to March 19, 2019 were retrospectively identified. An image of each patient was taken before the computed tomography by a 3D camera mounted to the ceiling. Using infrared imaging and machine learning algorithms, patient height and weight were estimated from this 3D camera image. A total of 363 images were used for training. The test set consisted of 90 images. The height and weight estimates were compared with true height and weight to determine absolute and percent error. A value of P < 0.05 indicated statistical significance. RESULTS:There was 2.0% (SD, 1.4) error in height estimation by the 3D camera, corresponding to 3.35 cm (SD, 2.39) absolute deviation (P = 1, n = 86). Weight estimation error was 5.1% (SD, 4.3), corresponding to 3.99 kg (SD, 3.11) absolute error (P = 0.74, n = 90). CONCLUSION/CONCLUSIONS:Pictures obtained from a 3D camera can accurately predict patient height and weight.
PMID: 34297511
ISSN: 1532-3145
CID: 4948682