Try a new search

Format these results:

Searched for:

in-biosketch:true

person:daneb01

Total Results:

112


Inter-reader agreement of the Society of Abdominal Radiology-American Gastroenterological Association (SAR-AGA) consensus reporting for key phenotypes at MR enterography in adults with Crohn disease: impact of radiologist experience

Dane, Bari; Qian, Kun; Gauvin, Simon; Ji, Hoon; Karajgikar, Jay; Kim, Nancy; Chang, Shannon; Chandarana, Hersh; Kim, Sooah
PURPOSE/OBJECTIVE:To assess inter-reader agreement of key features from the SAR-AGA recommendations for the interpretation and reporting of MRE in adult patients with CD, focusing on the impact of radiologist experience on inter-reader agreement of CD phenotypes. METHODS:Two experienced and two less-experienced radiologists retrospectively evaluated 99 MRE in CD patients (50 initial MRE, 49 follow-up MRE) performed from 1/1/2019 to 3/20/2020 for the presence of active bowel inflammation (stomach, proximal small bowel, ileum, colon), stricture, probable stricture, penetrating disease, and perianal disease. The MRE protocol did not include dedicated perianal sequences. Inter-rater agreement was determined for each imaging feature using prevalence-adjusted bias-adjusted kappa and compared by experience level. RESULTS:All readers had almost-perfect inter-reader agreement (κ > 0.90) for penetrating disease, abscess, and perianal abscess in all 99 CD patients. All readers had strong inter-reader agreement (κ: 0.80-0.90) in 99 CD patients for active ileum inflammation, proximal small bowel inflammation, and stricture. Less-experienced readers had significantly lower inter-reader agreement for active ileum inflammation on initial than follow-up MRE (κ 0.68 versus 0.96, p = 0.018) and for strictures on follow-up than initial MRE (κ 0.76 versus 1.0, p = 0.027). Experienced readers had significantly lower agreement for perianal fistula on follow-up than initial MRE (κ: 0.55 versus 0.92, p = 0.008). CONCLUSION/CONCLUSIONS:There was strong to almost-perfect inter-reader agreement for key CD phenotypes described in the SAR-AGA consensus recommendations including active ileum and proximal small bowel inflammation, stricture, penetrating disease, abscess, and perianal abscess. Areas of lower inter-reader agreement could be targeted for future education efforts to further standardize CD MRE reporting. Dedicated perianal sequences should be included on follow-up MRE.
PMID: 34324038
ISSN: 2366-0058
CID: 4949952

Frequency and significance of incidental liver lesions on MR enterography in adult patients

Dane, Bari; Bearison, Craig; Kim, Sooah
PURPOSE/OBJECTIVE:To evaluate the frequency and significance of incidental liver lesions identified on MR enterography (MRE) examinations to determine if dedicated sequences for liver evaluation are necessary in the routine MRE protocol. METHODS:A retrospective departmental database search identified 353 adult (212 women and 141 men; mean [±SD] age, 41.4 [17.0] years; range 18.1-91.9 years) MRE examinations performed in 2017. Radiology reports were reviewed for the presence and characterization of liver lesions, follow-up recommendation, and known malignancy. Follow-up cross-sectional imaging reports were reviewed for liver lesion stability. A senior abdominal radiologist with expertise in liver imaging categorized liver lesions as benign, indeterminate, or malignant and re-characterized indeterminate lesions using follow-up imaging as benign or malignant. RESULTS:Seventy-nine MRE (22.4%) described liver lesions and follow-up imaging was recommended in 4/79 (5.1%). Seventy-six liver lesions (96.2%) were characterized as benign (cysts/hemangiomas) on routine interpretation and expert review. One of these was recommended for follow-up imaging on initial report, which was characterized as hemangioma by expert review. The remaining 3 lesions (3.8%) were characterized as indeterminate both by initial report and expert radiologist review but re-characterized as benign after reviewing follow-up examinations. CONCLUSION/CONCLUSIONS:All incidental liver lesions identified on MRE in our cohort were benign. Therefore, additional sequences evaluating the liver are unnecessary for routine MRE.
PMID: 34217035
ISSN: 1873-4499
CID: 4932772

Crohn Disease Prognostication With Semiautomatic Dual-Energy Computed Tomography Enterography-Derived Iodine Density

Dane, Bari; Garada, Ahmad; O'Donnell, Thomas; Chang, Shannon; Megibow, Alec
OBJECTIVE:The objective of this study was to determine if dual-energy computed tomography enterography (DECTE)-obtained iodine density can predict medical management change or surgery in Crohn disease patients. METHODS:The most active-appearing bowel segment on DECTE in 21 Crohn disease patients was retrospectively interrogated with prototype software determining the percentage of bowel wall (I) in specified ranges. Patients were categorized into 3 groups after DECTE: (1) no management change, (2) outpatient medication change, and (3) inpatient admission or surgery. Crohn's disease activity index was calculated. Group 3's percentage iodine density of >3 mg/mL and Crohn's disease activity index were compared with group 1/2. Crohn's disease activity index and percentage iodine density of >2 mg/mL were compared for groups 2/3 versus group 1 patients. RESULTS:There were 5 group 1, 6 group 2, and 10 group 3 patients. Group 3 patients had higher frequency of iodine density >3 mg/mL (27%) compared with groups 1/2 patients (12.6%) (P < 0.05). Crohn's disease activity index was similar (P = 0.98). Groups 2/3 patients had 60.5% iodine density of >2 mg/mL, whereas group 1 patients had 31.7% iodine density of >2 mg/mL (P < 0.05). Crohn's disease activity index was similar (P = 0.12). CONCLUSIONS:Iodine density from DECTE may predict medical or surgical Crohn disease management.
PMID: 33661155
ISSN: 1532-3145
CID: 4801762

Radiation dose reduction, improved isocenter accuracy and CT scan time savings with automatic patient positioning by a 3D camera

Dane, Bari; O'Donnell, Thomas; Liu, Shu; Vega, Emilio; Mohammed, Sharon; Singh, Vivek; Kapoor, Ankur; Megibow, Alec
PURPOSE/OBJECTIVE:To compare CT isocenter accuracy, patient dose, and scan time in adults imaged with and without use of a 3D camera. METHOD/METHODS:571 CT examinations utilizing a 3D camera for initial patient positioning (optional radiographer isocenter adjustment) and 504 examinations scanned without the camera between 10/1/2018 and 3/19/2019 were retrospectively identified. All exams were chest or abdominopelvic CTs. The isocenters of these exams were compared with the true isocenters defined as the manually delineated centroid of the body in the CT volume. The size specific dose estimate (SSDE) (mGy) of radiation dose obtained from departmental software for the 4 most common protocols on one CT scanner was compared before and after implementation of the 3D camera. The times required for the entire scan and just the topogram "scout" were compared with and without the 3D camera for noncontrast chest and abdominopelvic CT enterography protocols. 2-tailed t-tests and Mann-Whitney U tests were used (P < 0.05 indicated statistical significance). RESULTS:The deviation from true isocenter was 6.8 ± 6.1 mm (P = 0.043) and 16.3 ± 14.0 mm (P < 0.01) with and without the 3D camera, respectively (P < 0.01). CT radiographers accepted isocenter location without alteration in 93 % of examinations. Average SSDE savings with the 3D camera ranged 1.0-2.4 mGy (21-31 %) for the 4 most commonly performed protocols (p < 0.01). Median scout time savings was 32 s (Camera vs. No-Camera cohorts) (P < 0.01). Average noncontrast chest CT and CT enterography scan time savings were 19 s and 17 s with the 3D camera, respectively (P < 0.01). CONCLUSIONS:The 3D camera improved accuracy of patient positioning while reducing radiation dose and examination time. Implementation of a 3D camera helps standardize workflow in a busy clinical practice.
PMID: 33454459
ISSN: 1872-7727
CID: 4760152

The humbling hemangioma: uncommon CT and MRI imaging features and mimickers of hepatic hemangiomas

Dane, Bari; Shanbhogue, Krishna; Menias, Christine O; Taffel, Myles T
Cavernous hemangiomas are among the most common liver lesions encountered in abdominal imaging. While classical imaging characteristics usually aid the radiologist in confidently arriving at its diagnosis, atypical hemangiomas can prove to be difficult to distinguish from other more worrisome hepatic lesions such as metastases and hepatocellular carcinoma. Furthermore, some malignant lesions can display features that simulate hemangiomas. The radiologist must be aware of these pitfalls to make an accurate diagnosis, when possible.
PMID: 33434867
ISSN: 1873-4499
CID: 4746752

Doubly Communicating Rectal Duplication

Ray, Juliet June; Venkatesh, Pooja Padmini; Dane, Bari; Remzi, Feza
PMID: 33179148
ISSN: 1873-4626
CID: 4665382

Reporting Templates for Magnetic Resonance Imaging and Water Soluble Contrast Enema in Patients with Ileal Pouch Anal Anastomosis: Experience from a Large Referral Center

Huang, Chenchan; Remzi, Feza; Dane, Bari; Esen, Eren; Ream, Justin M; Grieco, Michael; Megibow, Alec Jeffrey
Ileal pouch anal anastomosis (IPAA) is gold standard surgical procedure for treatment of ulcerative colitis and majority of patients with familial adenomatous polyposis. This procedure allows preservation of fecal continence and gastrointestinal continuity. However, it is associated with a wide variety of complications, which often have nonspecific and overlapping clinical presentations, making imaging an important part of work up for pouch dysfunction. The purpose of this article is to propose structured reporting templates for Magnetic Resonance Imaging (MRI) and Water Soluble Contrast Enema (WSCE) in IPAA patients based on our referral pouch center's experience. Included will be a review of salient surgical technique, pouch anatomy and imaging protocols, with an emphasis on systematic search pattern for evaluation of ileal pouch complications using proposed structured reporting MRI and WSCE templates.
PMID: 32936014
ISSN: 1546-3141
CID: 4593072

Visceral adipose tissue in patients with COVID-19: risk stratification for severity

Chandarana, Hersh; Dane, Bari; Mikheev, Artem; Taffel, Myles T; Feng, Yang; Rusinek, Henry
PURPOSE/OBJECTIVE:To assess visceral (VAT), subcutaneous (SAT), and total adipose tissue (TAT) estimates at abdominopelvic CT in COVID-19 patients with different severity, and analyze Body Mass Index (BMI) and CT estimates of fat content in patients requiring hospitalization. METHODS:to discriminate hospitalized patients from outpatients. RESULTS:in hospitalized patients compared to the outpatients (all p < 0.05). Area under the curve (AUC) of the clinical + CT model was higher compared to the clinical model (AUC 0.847 versus 0.750) for identifying patients requiring hospitalization. CONCLUSION/CONCLUSIONS:to the clinical model improved AUC in discriminating hospitalized from outpatients in this preliminary study.
PMCID:7398639
PMID: 32748252
ISSN: 2366-0058
CID: 4553822

Response assessment of hepatocellular carcinoma treated with yttrium-90 radioembolization: inter-reader variability, comparison with 3D quantitative approach, and role in the prediction of clinical outcomes

King, Michael J; Tong, Angela; Dane, Bari; Huang, Chenchan; Zhan, Chenyang; Shanbhogue, Krishna
OBJECTIVES/OBJECTIVE:To assess the inter-reader variability in response assessment for HCC treated with radioembolization (TARE) compared with 3D quantitative criteria (qEASL); and to evaluate their role in prediction of pathological necrosis and clinical outcomes. MATERIALS AND METHODS/METHODS:57 patients with 77 HCCs who underwent TARE were included. Five radiologists recorded multiple imaging features and assigned mRECIST/LIRADS Treatment Response (TR) categories on post-treatment MRI at 4-6 weeks and 6-9 months after TARE. qEASL categories were assigned by a separate reader. Inter-reader variability between LIRADS TR/mRECIST/qEASL were evaluated and hazards regression was used in predicting clinical outcomes. RESULTS:Inter-reader agreement was fair for mRECIST (K = 0.43 and 0.34 at first and second follow-up respectively); moderate for LIRADS TR (K = 0.48 and 0.53 at first and second follow-up respectively). Inter-criterion agreement was moderate to substantial (r = 0.41-0.65 and r = 0.54-0.60 at first and second follow-up) for mRECIST-qEASL. LIRADS TR correlated well with qEASL for all readers at both follow-ups (K = 0.45-0.78; K = 0.39-0.77 for first and second follow-up). qEASL was the most accurate in predicting Tumor-Free Survival (TFS) on first (HR 2.23 [1.44-3.46], p < 0.001) and second (HR 1.69 [1.15-2.48], p = 0.008) follow-up. LIRADS TR was the most accurate in predicting histopathological necrosis (8 patients underwent liver transplantation and 1 patient underwent tumor resection during the period of the study). CONCLUSIONS:HCC response assessment following TARE is challenging, resulting in poor to moderate inter-reader agreement for mRECIST, and moderate inter-reader agreement for LIRADS TR response assessment criteria. qEASL outperformed mRECIST criteria for early identification of responders and predicting TFS, suggesting an advantage in volumetric tumor response assessment. LIRADS TR outperformed other criteria in predicting pathological necrosis.
PMID: 33096408
ISSN: 1872-7727
CID: 4642632

Novel Dual-Energy Computed Tomography Enterography Iodine Density Maps Provide Unique Depiction of Crohn Disease Activity

Dane, Bari; OʼDonnell, Thomas; Ream, Justin; Chang, Shannon; Megibow, Alec
OBJECTIVE:To create a map of iodine densities within affected segments of small-bowel Crohn disease (CD) derived from contrast-enhanced dual-energy computed tomography enterography (DECTE) studies. METHODS:Twenty CD patients imaged with intravenous contrast-enhanced DECTE between June 2016 and December 2017 were retrospectively identified. Ten patients without clinical evidence of CD and 8 normal-appearing jejunal segments in CD patients were controls. Using prototype software, 8 manual contours were drawn along the mucosa of affected segments. Relatively normal-appearing bowel was included at the edges. These contours served as a basis for iodine density calculation and 3-dimensional iodine density map rendering. Color-coded iodine densities allowed detection and quantification of the most and least dense portion of each segment and also permitted relative comparison between segments. RESULTS:The average iodine density per CD involved segment ranged 1.0 to 3.3 mg/mL, which differed significantly from normal ileum (P < 0.0001) and normal-appearing jejunum in patients with CD (P = 0.0009). Standard deviations ranged from 0.8 to 1.7 mg/mL, which differed significantly from normal ileum (P = 0.0039) and normal-appearing jejunum in patients with CD (P = 0.0056). The amplitude of the power spectrum ranged from 0.66 to 3.3 demonstrating patches of iodine rather than uniform distribution. This differed significantly from normal ileum (P = 0.0005) and normal-appearing jejunum in patients with CD (P = 0.0004). CONCLUSIONS:Heterogeneous CD activity and distribution can be displayed as iodine density maps created from DECTE.
PMID: 32936579
ISSN: 1532-3145
CID: 4593102