RAPID PACING AND HIGH FREQUENCY JET VENTILATION SYNERGISTICALLY IMPROVE CATHETER STABILITY DURING AF ABLATION [Meeting Abstract]
Aizer, A; Qiu, J K; Cheng, A; Wu, P; Holmes, D; Jankelson, L; Bernstein, S A; Park, D S; Linton, P; Barbhaiya, C R; Chinitz, L A
Background: Increased catheter stability during AF ablation is associated with higher ablation success rates. Rapid cardiac pacing and high frequency jet ventilation (HFJV) have both been independently shown to improve catheter stability. Simultaneous modulation of cardiac and respiratory motion has not been previously studied.
Objective(s): To study the effects of modulating heart rate and respiratory rate simultaneously on catheter stability.
Method(s): Forty paroxysmal AF patients were randomized to four study conditions. Ablation lesions were created at 15 prespecified locations. Twenty patients received atrial pacing (500 msec) during the first half of each lesion; twenty patients were paced during the second half of each lesion. Within each group, half received HFJV and half received standard ventilation. Contact force (CF) variability, defined as CF standard deviation, was compared between study groups.
Result(s): Compared to sinus rhythm and standard ventilation, rapid pacing (5.45 g vs. 5.86 g; p=0.006) and HFJV (5.10 g; p=0.003) each significantly reduced mean CF standard deviation. Simultaneous pacing and HFJV produced even greater reduction of mean CF standard deviation (4.29 g; p<0.001) (Figure). Pacing and HFJV alone had similar effects on mean CF variability (p=0.2).
Conclusion(s): Rapid pacing and HFJV synergistically improve catheter stability during AF ablation. Simultaneous pacing with HFJV further optimizes catheter stability over pacing or HFJV alone and may improve ablation outcomes. [Figure presented]
Copyright
EMBASE:2002296075
ISSN: 1556-3871
CID: 4001842
ECHOCARDIOGRAPHY GUIDED AV OPTIMIZATION FOR DISOPYRAMIDE REFRACTORY OUTFLOW TRACT GRADIENT FOLLOWING PACING FOR GRADIENT IN HYPERTROPHIC CARDIOMYOPATHY [Meeting Abstract]
Niazi, O T; Beccarino, N; Stepanovic, A; Jankelson, L; Bernstein, S A; Park, D S; Holmes, D; Aizer, A; Sherrid, M; Chinitz, L A; Barbhaiya, C R
Background: Left ventricular outflow tract (LVOT) obstruction is associated with adverse outcomes in hypertrophic cardiomyopathy (HCM). AV sequential pacing has not demonstrated benefit for patients with medication-refractory LVOT obstruction in prospective, randomized clinical trials, although these trials did not include transthoracic echocardiogram (TTE) guided optimization or concomitant pharmacotherapy with disopyramide.
Objective(s): To evaluate efficacy of a standardized TTE guided AV optimization protocol for patients with persistent LVOT obstruction despite AV sequential pacing for reduction in LVOT gradient.
Method(s): Outcomes of 20 consecutive HCM patients with medication refractory LVOT gradients who were not surgical candidates and underwent AV sequential pacing from 8/2014 to 6/2017 were analyzed. ECG guided AV intervals were determined by the implanting cardiac electrophysiologist at the time of implant. Patients with incomplete response to initial settings underwent Doppler TTE guided AV optimization.
Result(s): All patients received maximally tolerated disopyramide and beta or calcium channel blockade. Following initial implant, 8 of 20 (40%) of patients had complete elimination of LVOT gradient with, and 12 of 20 (60%) had incomplete response and underwent TTE guided optimization. Compared to initial ECG guided programming, the TTE optimized sensed AV delays were shorter in all patients (mean reduction 51 +/- 48ms). Following TTE guided AV optimization, 9 of 12 patients had elimination of LVOT gradient, and 3 of 12 patients had 82.6 +/- 5.2% reduction in LVOT gradient. Patients undergoing TTE optimization had significant reduction in NYHA heart failure class (1.0 +/- 0 vs. 2.2 +/- 0.7, p=0.004).
Conclusion(s): TTE guided AV optimization shows promise as a means of improving outcomes in patients with incomplete response to medical therapy including disopyramide and AV sequential pacing for reduction of LVOT gradient in HCM.
Copyright
EMBASE:2002296016
ISSN: 1556-3871
CID: 4001862
PERSISTENT ATRIAL FIBRILLATION CATHETER ABLATION OUTCOMES STRATIFIED BY LEFT ATRIAL POSTERIOR WALL ISOLATION LESION SET CHARACTERISTICS [Meeting Abstract]
Barbhaiya, C R; Kogan, E V; Knotts, R; Pelaez, A V; Jankelson, L; Bernstein, S A; Park, D S; Holmes, D; Aizer, A; Chinitz, L A
Background: Left atrial posterior wall (LAPW) isolation is associated with favorable outcomes for catheter ablation of persistent atrial fibrillation (AF) in several studies. Reported techniques for LAPW isolation include ablation at the periphery without ablation within the LAPW, and high density ablation of all sites of electrical activity within the LAPW. The proportion of LA isolated by the lesion set in various reports also varies greatly. The optimal technique to achieve LAPW isolation is not clear.
Objective(s): To assess impact of ablation lesion density within the LAPW and dimensions of LAPW isolation region on arrhythmia recurrence in catheter ablation of persistent AF.
Method(s): LAPW lesion density, and LAPW isolation surface area relative to total LA surface area were calculated using electroanatomic maps of 110 consecutive patients undergoing LAPW isolation for persistent AF (CARTO 3, Biosense Webster, Inc.) LAPW isolation lesion sets were created at the discretion of 5 experienced operators after LA voltage mapping. LAPW and PV entrance block and exit block were confirmed. Arrhythmia recurrence at one year was assessed by the Kaplan-Meier method.
Result(s): LAPW lesion density ranged from 0% - 99%. Proportion of LA surface area isolated ranged from 35% - 75%. There was no significant difference in arrhythmia-free survival by quartile of LAPW ablation density (81% vs. 68% vs. 85% vs. 78%, p=0.8), or by quartile of LA surface area proportion isolated (85% vs. 75% vs. 79% vs. 74%, p=0.3). Voltage map guided LAPW isolation resulted in no significant difference in incidence of recurrent arrhythmia by quartile of total LA surface area (81% vs. 78% vs. 78% vs. 74%, p=0.5).
Conclusion(s): Neither the density of ablation within the LAPW nor the dimensions of the isolated region predicted arrhythmia-free survival LAPW isolation for catheter ablation of persistent AF. Voltage map guided LAPW isolation resulted in similar ablation efficacy regardless of LA size.
Copyright
EMBASE:2002272949
ISSN: 1556-3871
CID: 4007262
PSEUDOPOLYMORPHIC WIDE COMPLEX TACHYCARDIA IN A CHILD WITH LQT2 [Meeting Abstract]
Jankelson, L; Magnani, S; Cecchin, F; Tan, R; Barbhaiya, C R; Aizer, A; Holmes, D; Bernstein, S A; Park, D S; Borneman, L; Cerrone, M; Chinitz, L A
Background: Implantable loop recorder (ILR) based monitoring of patients with LQTS allows enhanced arrhythmia surveillance and can help distinguish life-threatening from benign arrhythmias.
Objective(s): We present a case of a child with LQTS and wide complex tachycardia detected by ILR.
Result(s): An asymptomatic 12 year old with LQT2 syndrome, positive for a G648S hERG mutation, with baseline QTc of 510-550ms despite maximally tolerated Nadolol (Figure 1A) was followed in our inherited arrhythmia center. His affected mother has had multiple syncopal events related to polymorphic ventricular tachycardia (VT) and appropriate ICD shocks. We elected to implant him with ILR to allow longitudinal monitoring and early detection of arrhythmia. He presented 6 months later with 2 alerts for asymptomatic polymorphic, wide complex tachycardia at ~200 bpm during sleeping (Figure 1B). Electrophysiology study (EPS) was performed to determine etiology of the arrhythmia. Dual AV node physiology was present. Sinus tachycardia at 200 bpm with left bundle branch block (LBBB) morphology was induced with Isoproterenol and atrio-fascicular pathway was excluded. Respiratory changes resulted in the tachycardia appearing as polymorphic on the ILR during the EPS.
Conclusion(s): This is the first reported case of sinus tachycardia with LBBB aberrancy in a child with LQTS. Pseudopolymorphic wide complex tachycardia was the result of aberrancy and respiratory artifact. Combined ILR monitoring and EP study provided a correct diagnosis, thus avoiding further interventions. [Figure presented]
Copyright
EMBASE:2002272661
ISSN: 1556-3871
CID: 4007282
POST ELECTROPHYSIOLOGY PROCEDURE MONITORING WITH A NOVEL WEARABLE DEVICE [Meeting Abstract]
Jankelson, L; Bennet, M; Barbhaiya, C R; Aizer, A; Holmes, D; Bernstein, S A; Park, D S; Chinitz, L A
Background: The rapid increase in the number and complexity of electrophysiology (EP) procedures performed annually requires improved strategies to safely enhance post procedural monitoring and early discharge.
Objective(s): To determine if a wearable device that continuously and non-invasively measures vital signs and hemodynamic parameters can predict post-procedure cardiovascular decompensation.
Method(s): Investigator initiated, prospective study of 21 patients receiving either atrial fibrillation ablation (N=16) or device implantation (N=5). Patients were monitored for the post-procedure time periods ranging from 8 to18 hours with two techniques: 1) sporadic measurements with a conventional vital sign monitor; and 2) continuous measurements with toSense's CoVaTM Monitoring System, an FDA-cleared wearable device measuring stroke volume (SV), cardiac output (CO), thoracic fluid index (TFI), heart rate (HR), and respiration rate (RR). CoVaTM-generated data were wirelessly analyzed to established markers of decompensation, defined as decline in systolic blood pressure of >20mmHg over 5 minutes or SpO2 values < 90%. Decompensation index (DI), a normalized index defined as: DI = mean{(norm d[HR]/dt) + (norm d[HRV]/dt) + (norm d[SV]/dt) + (norm d[RR]/dt) + (norm [TI]/dt)} was used to predict decompensation events.
Result(s): Patients continuously monitored for >8 hours with CoVaTM, who were also sporadically measured at least 5 times with the vital sign monitor (N=11) were analyzed. Agreement of the two parameters measured by both devices-HR and RR-was: DELTAHR = 6.5+/-0.3 bpm; DELTARR = 3.8+/-0.8 breaths/min. 55% of patients (N=6) experienced brief decompensation events. The vital sign monitor made sporadic measurements every 95+/-21.3 minutes. Using DI, CoVaTM predicted 78% of the total patient decompensations, with the average prediction being 22+/-23 minutes in advance.
Conclusion(s): Continuous measurements with a wearable device may detect post-procedure decompensation in patients receiving electrophysiology procedures or device implantations with greater accuracy and better temporal resolution as compared to sporadic measurements with conventional vital sign monitors.
Copyright
EMBASE:2002272580
ISSN: 1556-3871
CID: 4007292
Reducing right ventricular pacing burden: algorithms, benefits, and risks
Jankelson, Lior; Bordachar, Pierre; Strik, Mark; Ploux, Sylvain; Chinitz, Larry
Algorithms designed to reduce the burden of right ventricular pacing are widely available in modern implantable pacing devices. To ensure safe and optimal utilization, understanding the properties of these algorithms as well as their possible unfavourable effects is essential. In this review, we discuss in detail the technical and clinical aspects of rhythm management algorithms and update on their significant recent modifications. In addition, we highlight possible adverse phenomena that may be induced by these different pacing algorithms intended to minimize pacing.
PMID: 30428056
ISSN: 1532-2092
CID: 3457302
Behavior of leadless AV synchronous pacing during atrial arrhythmias and stability of the atrial signals over time- Results of the MARVEL Evolve sub-analysis
Garweg, Christophe; Splett, Vincent; Sheldon, Todd J; Chinitz, Larry; Ritter, Philippe; Steinwender, Clemens; Lemme, Francesca; Willems, Rik
INTRODUCTION/BACKGROUND:The MARVEL study demonstrated at a single time point that accelerometer (ACC)-based atrial sensing improves AV synchrony (AVS) in patients with AV block and a Micra pacemaker. The purpose of the MARVEL Evolve sub-study was to assess performance over time. METHODS:This prospective single-center study compared AVS and ACC signals at two visits ≥6 months apart. Custom software was temporarily downloaded into the Micra at each visit and AVS was measured during 30 min at rest. RESULTS:Nine patients from the MARVEL study were enrolled. The mean (±SD) age was 82.3±6.0 years old, 67% were male, and a Micra was implanted for 6.0±6.4 months. High degree AV block was present in 4 patients, whereas 5 with predominantly intrinsic conduction required intermittent pacing for bradycardia. The mean interval between visits was 7.1±0.6 months. Seven patients had normal sinus node function at both visits and were included in a paired analysis. Both ACC signal amplitude (visit 2-visit 1 = 1.4 mG; 95% CI [-25.8 to 28.4 mG]; p = 0.933) and AVS (visit 1: 90.8 %, 95% CI [72.4, 97.4] and visit 2: 91.4%, 95% CI [63.8, 98.5]; p = 0.740) remained stable. Three patients had spontaneous atrial tachycardia. During atrial fibrillation, no atrial contraction was detected or tracked. During atrial flutter, intermittent tracking resulted in a ventricular rate of 60±8 bpm; there was no ventricular pacing > 100 bpm. CONCLUSION/CONCLUSIONS:ACC signals amplitude and performance of AVS pacing were stable over time. During atrial arrhythmias, the AV synchronous pacing mode behaved safely.
PMID: 30687931
ISSN: 1540-8159
CID: 3626312
Simultaneous pace-ablate during CARTO-guided pulmonary vein isolation with a contact-force sensing radiofrequency ablation catheter
Barbhaiya, Chirag R; Aizer, Anthony; Knotts, Robert; Bernstein, Scott; Park, David; Holmes, Douglas; Chinitz, Larry A
PURPOSE/OBJECTIVE:Elimination of pace-capture along pulmonary vein isolation (PVI) lesion sets reduces atrial fibrillation (AF) recurrence in catheter ablation of paroxysmal AF. Pacing from the RF ablation electrode during RF application is prevented within the CARTO electroanatomic mapping system (Biosense Webster, Inc.) due to theoretical safety considerations. We evaluated a method of pacing the distal ablation electrode during RF application in the CARTO system, thus avoiding repeated activation and inactivation of the pacing channel and facilitating immediate recognition of pace-capture loss. We investigated the safety, feasibility, and utility of simultaneous pace-ablate (SPA) during AF ablation with the CARTO-3 system and a contact-force sensing RF ablation catheter. METHODS:Safety of feasibility of SPA was evaluated in 250 patients undergoing first-time AF ablation. Frequency and regional distribution of pace-capture following PVI was evaluated in a cohort of 50 consecutive patients undergoing catheter ablation of paroxysmal AF. RESULTS:SPA was successfully performed in all 250 patients without adverse event. At least one pace-capture site was noted in 22 of 50 PAF patients (44%), and pace-capture following PVI was most common at anterior and superior left atrial sites. There were 2.0 ± 3.3 RF applications during pacing via the distal ablation electrode per patient, and all lesions sets were successfully rendered unexcitable. CONCLUSIONS:Pace-capture along the completed PVI lesion set remains common despite utilization of contact-force sensing RF ablation catheters and automated lesion annotation. Simultaneous pace-ablate in AF ablation using the CARTO system may be safely used to render atrial lesion sets unexcitable.
PMID: 30264289
ISSN: 1572-8595
CID: 3314572
Response to atrial arrhythmias in an atrioventricular synchronous ventricular leadless pacemaker: A case report in a paroxysmal atrial fibrillation patient
Garweg, Christophe; Sheldon, Todd J; Chinitz, Larry; Ritter, Philippe; Steinwender, Clemens; Willems, Rik
PMCID:6301888
PMID: 30581731
ISSN: 2214-0271
CID: 3560032
Echocardiographic Guidance of the Novel WaveCrest Left Atrial Appendage Occlusion Device
Vainrib, Alan F; Bamira, Daniel; Benenstein, Ricardo J; Aizer, Anthony; Chinitz, Larry A; Saric, Muhamed
PMCID:6302034
PMID: 30582095
ISSN: 2468-6441
CID: 3560082