Try a new search

Format these results:

Searched for:

in-biosketch:true

person:daneb01

Total Results:

112


Hypercoagulability in COVID-19: Identification of Arterial and Venous Thromboembolism in the Abdomen, Pelvis, and Lower Extremities

Dane, Bari; Smereka, Paul; Wain, Reese; Kim, Danny; Katz, Douglas S
The purpose of this article is to describe arterial and venous thromboembolism in the abdomen, pelvis, and lower extremities. Eight-two COVID patients with abdominal ultrasound or CT were retrospectively compared with non-COVID patients for thromboembolism and solid-organ infarction. Nine (11%) COVID-19 patients had thromboembolic findings with medium to large-sized arterial thrombi in 5/82. One non-COVID patient had known portal vein thrombus on CT. Thromboembolic findings occurred more frequently in patients with than without COVID-19 (p=0.02).
PMID: 32603220
ISSN: 1546-3141
CID: 4504082

Preserving Radiology Resident Education During the COVID-19 Pandemic: The Simulated Daily Readout

Recht, Michael P; Fefferman, Nancy R; Bittman, Mark E; Dane, Bari; Fritz, Jan; Hoffmann, Jason C; Hood, Joseph; Mercado, Cecilia L; Mahajan, Sonia; Sheth, Monica M
RATIONALE AND OBJECTIVES/OBJECTIVE:The educational value of the daily resident readout, a vital component of resident training, has been markedly diminished due to a significant decrease in imaging volume and case mix diversity. The goal of this study was to create a "simulated" daily readout (SDR) to restore the educational value of the daily readout. MATERIALS AND METHODS/METHODS:To create the SDR the following tasks were performed; selection of cases for a daily worklist for each resident rotation, comprising a combination of normal and abnormal cases; determination of the correct number of cases and the appropriate mix of imaging modalities for each worklist; development of an "educational" environment consisting of separate "instances" of both our Picture Archive Communication System and reporting systems; and the anonymization of all of the cases on the worklists. Surveys of both residents and faculty involved in the SDR were performed to assess its effectiveness. RESULTS:Thirty-two residents participated in the SDR. The daily worklists for the first 20 days of the SDR included 3682 cases. An average of 480 cases per day was dictated by the residents. Surveys of the residents and the faculty involved in the SDR demonstrated that both agreed that the SDR effectively mimics a resident's daily work on rotations and preserves resident education during the Coronavirus Disease 2019 crisis. CONCLUSION/CONCLUSIONS:The development of the SDR provided an effective method of preserving the educational value of the daily readout experience of radiology residents, despite severe decreases in imaging exam volume and case mix diversity during the Coronavirus Disease 2019 pandemic.
PMID: 32553278
ISSN: 1878-4046
CID: 4484992

Unexpected Findings of Coronavirus Disease (COVID-19) at the Lung Bases on Abdominopelvic CT

Dane, Bari; Brusca-Augello, Geraldine; Kim, Danny; Katz, Douglas S
OBJECTIVE. The purpose of this study is to report unanticipated lung base findings on abdominal CT in 23 patients concerning for coronavirus disease (COVID-19). In these patients, who were not previously suspected of having COVID-19, abdominal pain was the most common indication for CT (n = 19), and 11 patients had no extrapulmonary findings. Seventeen patients underwent polymerase chain reaction testing, which returned positive results for all 17. CONCLUSION. Unsuspected coronavirus disease may be strongly suggested on the basis of lung findings on abdominopelvic CT.
PMID: 32319792
ISSN: 1546-3141
CID: 4397152

A clinical and radiographic model to predict surgery for acute small bowel obstruction in Crohn's disease

Lowe, Sarina C; Ream, Justin; Hudesman, David; Malter, Lisa; Bosworth, Brian; Xia, Yuhe; Zhong, Hua; Dane, Bari; Megibow, Alec; Chang, Shannon
PURPOSE/OBJECTIVE:For more than half of Crohn's disease patients, strictures will cause bowel obstructions that require surgery within 10 years of their initial diagnosis. This study utilizes computed tomography imaging and clinical data obtained at the initial emergency room visit to create a prediction model for progression to surgery in Crohn's disease patients with acute small bowel obstructions. METHODS:A retrospective chart review was performed for patients who presented to the emergency room with an ICD-10 diagnosis for Crohn's disease and visit diagnosis of small bowel obstruction. Two expert abdominal radiologists evaluated the CT scans for bowel wall thickness, maximal and minimal luminal diameters, length of diseased segment, passage of oral contrast, evidence of penetrating disease, bowel wall hyperenhancement or stratification, presence of a comb sign, fat hypertrophy, and small bowel feces sign. The primary outcome was progression to surgery within 6 months of presentation. The secondary outcome was time to readmission. RESULTS:Forty patients met the inclusion criteria, with 78% receiving medical treatment alone and 22% undergoing surgery within 6 months of presentation to the emergency room. Multivariable analysis produced a model with an AUC of 92% (95% CI 0.82-1.00), 78% sensitivity, and 97% specificity, using gender, body mass index, and the radiographic features of segment length, penetrating disease, and bowel wall hyperenhancement. CONCLUSIONS:The model demonstrates that routine clinical and radiographic data from an emergency room visit can predict progression to surgery, and has the potential to risk stratify patients, guide management in the acute setting, and predict readmission.
PMID: 32296895
ISSN: 2366-0058
CID: 4383612

Crohn's Disease Activity Quantified by Iodine Density Obtained From Dual-Energy Computed Tomography Enterography

Dane, Bari; Duenas, Sean; Han, Joseph; OʼDonnell, Thomas; Ream, Justin; Chang, Shannon; Megibow, Alec
OBJECTIVE:The objective of this study was to assess if bowel wall iodine density obtained from dual-source, dual-energy computed tomography enterography (DECTE) could be a biomarker of Crohn's disease activity. METHODS:Twenty-two patients with Crohn's disease imaged with DECTE from February 2016 to May 2018 were retrospectively identified by departmental report search. Iodine maps were created with commercial software (Syngovia). Iodine content was normalized to the aorta, and then manual dual-energy region-of-interest cursors were placed over the visibly assessed maximal and minimal iodine density within segments of involved as well as unaffected small bowel. The mixed Hounsfield unit value, maximum iodine density (Imax), and minimum iodine density (Imin) were recorded. The length of affected bowel demonstrating maximum disease activity as a percentage of overall involvement was subjectively assessed. A weighted iodine density (Iweighted) was calculated. The clinical assessment of disease activity using erythrocyte sedimentation rate, C-reactive protein, fecal calprotectin, colonoscopy/endoscopy, and surgery, if available, served as the reference standard. The Crohn's disease activity index was also used as a separate additional reference standard. RESULTS:Significant heterogeneity within the affected segments was present. The average Imax and Imin of affected bowel was 4.27 ± 1.11 (2.4-7.4) mg/mL and 2.71 ± 0.51 (2.2-3.9) mg/mL, respectively. Iodine density of normal-appearing small bowel was 1.40 ± 0.26 (0.9-1.9) mg/mL. The Imax and Imin of affected bowel differed significantly from normal bowel (P < 0.0001). Mixed Hounsfield unit (101.82 ± 27.5) also statistically differed (46.33 ± 19.62) (P < 0.0001). Using overall clinical assessment as the reference standard, all patients with Imin of greater than 2.6 mg/mL, Iweighted of greater than 3.3 mg/mL, or Imax of greater than 4.7 mg/mL had clinically active disease. Sixteen of 17 patients with Imin of greater than 2.2 mg/mL and 14/15 with Iweighted of greater than 3 mg/mL had clinically active disease. Using Crohn's disease activity index as the reference standard, all patients with Imin of greater than 2.7 mg/mL, Iweighted of greater than 3.6 mg/mL, or Imax of greater than 5.4 mg/mL had clinically active disease. The median effective dose was 4.64 ± 1.68 mSv (range, 2.03-8.12 mSv). CONCLUSIONS:Iodine density obtained from DECTE highlights regions of maximal activity within affected bowel segments. An iodine density of 2 mg/mL appears to be a threshold between normal bowel segments and those with active Crohn's disease. Iodine density measurement thresholds Imin of greater than 2.6 mg/mL, Iweighted of greater than 3.3 mg/mL, and Imax of greater than 4.7 mg/mL correlate with established clinical markers of disease activity, with Imin seemingly most useful in daily clinical practice.
PMID: 32195803
ISSN: 1532-3145
CID: 4353112

Interreader Concordance of the TI-RADS: Impact of Radiologist Experience

Chung, Ryan; Rosenkrantz, Andrew B; Bennett, Genevieve L; Dane, Bari; Jacobs, Jill E; Slywotzky, Chrystia; Smereka, Paul N; Tong, Angela; Sheth, Sheila
OBJECTIVE. The objective of this article is to assess radiologist concordance in characterizing thyroid nodules using the American College of Radiology Thyroid Imaging Reporting and Data System (TI-RADS), focusing on the effect of radiologist experience on reader concordance. MATERIALS AND METHODS. Three experienced and three less experienced radiologists assessed 150 thyroid nodules using the TI-RADS lexicon. Percent concordance was determined for various endpoints. RESULTS. Interreader concordance for the five TI-RADS categories was 87.2% for shape, 81.2% for composition, 76.1% for echogenicity, 72.9% for margins, and 69.8% for echogenic foci. Concordance for individual features was 96.3% for rim calcifications, 90.8% for macrocalcifications, 90.1% for spongiform, 83.5% for comet tail artifact, and 77.7% for punctate echogenic foci. Concordance for the TI-RADS level and recommendation for fine-needle aspiration (FNA) were 50.4% and 78.9%, respectively. Concordance was significantly (p < 0.05) higher for less experienced readers in identifying margins (84.3% vs 67.4%), echogenic foci (76.9% vs 69.3%), comet tail artifact (89.6% vs 79.2%), and punctate echogenic foci (85.3% vs 75.5%), and lower for peripheral rim calcifications (95.0% vs 97.8 %), but was not different (p > 0.05) for the remaining categories and features. CONCLUSION. A range of TI-RADS categories, features, and recommendations for FNA had generally moderate interreader agreement among six radiologists. Our results show that concordance for numerous characteristics was significantly higher for the less experienced versus the more experienced readers. These results suggest that less experienced readers relied more on the explicit TI-RADS criteria, whereas the experienced radiologists partially relied on their accumulated experience when forming impressions. However, the overall TI-RADS level and recommendation for FNA were unaffected, supporting the robustness of the TI-RADS lexicon and its continued use in practice.
PMID: 32097031
ISSN: 1546-3141
CID: 4323312

Pancreas deformation in the presence of tumors using feature tracking from free-breathing XD-GRASP MRI

Chitiboi, Teodora; Muckley, Matthew; Dane, Bari; Huang, Chenchan; Feng, Li; Chandarana, Hersh
BACKGROUND:Quantifying the biomechanical properties of pancreatic tumors could potentially help with assessment of tumor aggressiveness, prognosis, and prediction of therapy response. PURPOSE/OBJECTIVE:To quantify respiratory-induced deformation in the pancreas and pancreatic lesions using XD-GRASP (eXtra-Dimensional Golden-angle RAdial Sparse Parallel), MRI. STUDY TYPE/METHODS:W) imaging were studied. SUBJECTS/METHODS:Thirty-two patients (12 male and 20 female) including nine with pancreatic lesions constituted our study cohort. FIELD STRENGTH/SEQUENCE/UNASSIGNED:WI contrast-enhanced gradient echo radial free-breathing acquisition. ASSESSMENT/RESULTS:Using the XD-GRASP imaging technique, the acquired free-breathing radial data were sorted and binned into 10 consecutive respiratory motion states that were jointly reconstructed. 3D deformation fields along the respiratory dimension were computed using an optical flow method and were analyzed in the pancreas. STATISTICAL TESTS/UNASSIGNED:The Wilcoxon signed-rank test was used to assess the difference in average displacement across pancreatic regions, while the Wilcoxon rank-sum test was used for displacement differences between patients with and without tumors. The interclass correlation coefficient (ICC) was computed to assess consistency between observers for each image quality measure. RESULTS:There was a significantly larger displacement in the pancreatic tail compared with the head (8.2 ± 3.7 mm > 5.8 ± 2.4 mm; P < 0.001) and body regions (8.2 ± 3.7 mm > 6.6 ± 2.9 mm; P < 0.001). Furthermore, there was reduced normalized average displacement in patients with pancreatic lesions compared with subjects without lesions (0.33 ± 0.1 < 0.69 ± 0.26, P < 0.001 for the head; 0.30 ± 0.1 < 0.84 ± 0.31, P < 0.001 for the body; and 0.44 ± 0.31 < 1.08 ± 0.53, P < 0.001 for the tail, respectively). DATA CONCLUSION/UNASSIGNED:Free-breathing respiratory motion-sorted XD-GRASP MRI has the potential to noninvasively characterize the biomechanical properties of the pancreas by quantifying breathing-induced mechanical displacement. LEVEL OF EVIDENCE/METHODS:4 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019.
PMID: 30854767
ISSN: 1522-2586
CID: 3732932

Exploring CMS Quality Measure #405 for Small Incidental Abdominal Lesions

Dane, Bari; Rosenkrantz, Andrew B
PMID: 29933974
ISSN: 1558-349x
CID: 3158442

Utility of Water Siphon Maneuver for Eliciting Gastroesophageal Reflux During Barium Esophagography: Correlation With Histologic Findings

Dane, B; Doshi, A; Khan, A; Megibow, A
OBJECTIVE:The objective of this study is to evaluate whether the water siphon maneuver improves detection of gastroesophageal (GE) reflux during barium esophagography compared with observation for spontaneous reflux only. Histopathologic analysis is the reference standard. MATERIALS AND METHODS/METHODS:This retrospective study assessed 87 outpatients who underwent both barium esophagography and upper endoscopy-guided biopsy within a 30-day interval. The water siphon maneuver was routinely performed when spontaneous GE reflux was not observed during the fluoroscopic study. Radiology reports were reviewed for mentions of the presence of reflux and the circumstances in which it was observed (as a spontaneous occurrence or as a result of the water siphon maneuver). Pathology reports from subsequent endoscopic biopsies were reviewed to identify histologic changes of reflux disease. The sensitivity, specificity, and accuracy of esophagography, observation for spontaneous reflux, and the water siphon maneuver were calculated and then compared using a McNemar test. RESULTS:Of the 87 patients, 57 (65.5%) had GE reflux diagnosed on the basis of histologic changes noted on endoscopy, and 30 (34.5%) did not. A total of 57 patients (65.5%) showed reflux during esophagography, 41 (71.9%) of whom had reflux diagnosed by the water siphon maneuver, and 16 (28.1%) had reflux diagnosed on the basis of observation of spontaneous reflux. Forty-four patients had reflux diagnosed on the basis of both a barium study and histologic findings; 13 patients had reflux noted on esophagography but had negative histologic findings. The overall sensitivity, specificity, and accuracy of esophagography for reflux were 77.2%, 56.7%, and 70.1%, respectively. Spontaneous reflux alone had a sensitivity, specificity, and accuracy of 21.1%, 86.7%, and 43.7%, respectively. The water siphon maneuver showed a sensitivity of 71.1%, a specificity of 65.4%, and accuracy of 69.0%. The differences in the sensitivity, specificity, and accuracy of the water siphon maneuver versus observation of spontaneous reflux were statistically significant (p ≤ 0.004). CONCLUSION/CONCLUSIONS:A properly performed and interpreted water siphon maneuver significantly increases the sensitivity and accuracy for GE reflux during esophagography, compared with observation for spontaneous reflux alone. The water siphon maneuver is a simple addition to barium esophagography that improves sensitivity and accuracy for the diagnosis of GE reflux compared with observation alone.
PMID: 29894215
ISSN: 1546-3141
CID: 3155182

Image Quality on Dual-energy CTPA Virtual Monoenergetic Images: Quantitative and Qualitative Assessment

Dane, Bari; Patel, Hersh; O'Donnell, Thomas; Girvin, Francis; Brusca-Augello, Geraldine; Alpert, Jeffrey B; Niu, Bowen; Attia, Mariam; Babb, James; Ko, Jane P
RATIONALE AND OBJECTIVES/OBJECTIVE:This study aims to determine the optimal photon energy for image quality of the pulmonary arteries (PAs) on dual-energy computed tomography (CT) pulmonary angiography (CTPA) utilizing low volumes of iodinated contrast. MATERIALS AND METHODS/METHODS:The study received institutional review board exemption and was Health Insurance Portability and Accountability Act compliant. Adults (n = 56) who underwent dual-energy CTPA with 50-60 cc of iodinated contrast on a third-generation dual-source multidetector CT were retrospectively and consecutively identified. Twelve virtual monoenergetic kiloelectron volt (keV) image data sets (40-150 keV, 10-keV increments) were generated with a second-generation noise-reducing algorithm. Standard regions of interest were placed on main, right, left, and right interlobar pulmonary arteries; pectoralis muscle; and extrathoracic air. Attenuation [mean CT number (Hounsfield unit, HU)], noise [standard deviation (HU)], signal to noise (SNR), and contrast to noise ratio were evaluated. Three blinded chest radiologists rated (from 1 to 5, with 5 being the best) randomized monoenergetic and weighted-average images for attenuation and noise. P <.05 was considered significant. RESULTS:Region of interest mean CT number increased as keV decreased, with 40 keV having the highest value (P < .001). Mean SNR was highest for 40-60 keV (P <.05) (14.5-14.7) and was higher (P <.05) than all remaining energies (90-150 keV) for all vessel regions combined. Contrast to noise ratio was highest for 40 keV (P <.001) and decreased as keV increased. SNR was highest at 60 and 70 keV, only slightly higher than 40-50 keV (P <.05). Reader scores for 40-50 keV were greater than other energies and weighted-average images (P <.05). CONCLUSIONS:Kiloelectron volt images of 40-50 keV from the second-generation algorithm optimize attenuation on dual-energy CTPA and can potentially aid in interpretation and avoiding nondiagnostic examinations.
PMID: 29398436
ISSN: 1878-4046
CID: 2979202