Utility of brain natriuretic peptide as a predictor of atrial fibrillation after cardiac operations
Tavakol, Morteza; Hassan, Kashif Z; Abdula, Raushan K; Briggs, William; Oribabor, Charles E; Tortolani, Anthony J; Sacchi, Terrence J; Lee, Leonard Y; Heitner, John F
BACKGROUND:Atrial fibrillation (AF) occurs frequently after coronary bypass grafting and valve operations. Brain natriuretic peptide (BNP) has been shown to predict recurrence of AF in congestive heart failure. It is a potential biomarker for preoperative risk stratification for development of AF in at-risk patients. METHODS:A total of 398 consecutive patients were prospectively evaluated for new-onset AF after heart operations. Patients with a history of AF and presence of permanent pacemaker were excluded. BNP levels were measured before and immediately after the operation. RESULTS:AF occurred in 20%. AF was more likely to develop in patients who were older, who underwent valve operations, had a lower ejection fraction, and a larger left atrial size. Preoperative exposure to statins (62% vs 43%, p < 0.01) and angiotensin inhibitors (60% vs 45%, p = 0.02) was more common in patients without AF. BNP values were insignificantly higher preoperatively (361 vs 302 mg/dL, p = 0.3) and postoperatively (312 vs. 229 mg/dL, p = 0.15) in patients with AF. Multivariate logistic analysis showed that older age (odds ratio [OR], 3.1, 95% confidence interval [CI], 1.7 to 5.6), lower ejection fraction (OR, 2.0; 95% CI, 1.2 to 3.3), larger left atrial size (OR, 3.1; 95% CI, 1.9 to 4.9), and nonuse of angiotensin inhibitors (OR, 2.3; 95% CI, 1.1 to 4.8) were independently associated with AF. CONCLUSIONS:This study does not support use of BNP for prediction of AF. Age, low ejection fraction, large left atrial size, and nonuse of angiotensin blocking agents were found to be significant predictors of AF development.
PMID: 19699901
ISSN: 1552-6259
CID: 4777362
Effect of renal function loss on NT-proBNP level variations
Bernstein, Larry H; Zions, Michael Y; Haq, Salman A; Zarich, Stuart; Rucinski, James; Seamonds, Bette; Berger, Stanley; Lesley, Daniel Y; Fleischman, William; Heitner, John F
OBJECTIVE:NT-proBNP level is used for the detection of acute CHF and as a predictor of survival. However, a number of factors, including renal function, may affect the NT-proBNP levels. This study aims to provide a more precise way of interpreting NT-proBNP levels based on GFR, independent of age. METHODS:This study includes 247 pts in whom CHF and known confounders of elevated NT-proBNP were excluded, to show the relationship of GFR in association with age. The effect of eGFR on NT-proBNP level was adjusted by dividing 1000 x log(NT-proBNP) by eGFR then further adjusting for age in order to determine a normalized NT-proBNP value. RESULTS:The normalized NT-proBNP levels were affected by eGFR independent of the age of the patient. CONCLUSION/CONCLUSIONS:A normalizing function based on eGFR eliminates the need for an age-based reference ranges for NT-proBNP.
PMID: 19298805
ISSN: 1873-2933
CID: 4777342
Late presentation of a lead perforation as a complication of permanent pacemaker insertion [Case Report]
Haq, Salman A; Heitner, John F; Lee, Leonard; Kassotis, John T
Lead perforation is a less-recognized delayed complication of device implantation. Delay in recognition may prove fatal. Predictors of postimplantation pericardial effusion, which serves as a marker of perforation, include concomitant use of transvenous pacemaker, steroid use within 7 days, and older age. The authors report a case of an 86-year-old patient who presented with a lead perforation 16 months following the original pacemaker insertion. Following surgical repair with sternotomy, a new ventricular lead was placed via a transvenous approach at the right ventricular septum. A higher clinical suspicion should be maintained in the elderly in whom perforation occurs more frequently, and consideration should be given to implanting the lead in sites other than the right ventricular apex to minimize the risk of this late complication.
PMID: 18388077
ISSN: 1940-1574
CID: 4777322
Detection of left ventricular thrombus by delayed-enhancement cardiovascular magnetic resonance prevalence and markers in patients with systolic dysfunction
Weinsaft, Jonathan W; Kim, Han W; Shah, Dipan J; Klem, Igor; Crowley, Anna Lisa; Brosnan, Rhoda; James, Olga G; Patel, Manesh R; Heitner, John; Parker, Michele; Velazquez, Eric J; Steenbergen, Charles; Judd, Robert M; Kim, Raymond J
OBJECTIVES/OBJECTIVE:This study sought to assess the prevalence and markers of left ventricular (LV) thrombus among patients with systolic dysfunction. BACKGROUND:Prior studies have yielded discordant findings regarding prevalence and markers of LV thrombus. Delayed-enhancement cardiovascular magnetic resonance (DE-CMR) identifies thrombus on the basis of tissue characteristics rather than just anatomical appearance and is potentially highly accurate. METHODS:Prevalence of thrombus by DE-CMR was determined in 784 consecutive patients with systolic dysfunction (left ventricular ejection fraction [LVEF] <50%) imaged between July 2002 and July 2004. Patients were recruited from 2 separate institutions: a tertiary-care referral center and an outpatient clinic. Comparison to cine-cardiovascular magnetic resonance (CMR) was performed. Follow-up was undertaken for thrombus verification via pathology evaluation or documented embolic event within 6 months after CMR. Clinical and imaging parameters were assessed to determine risk factors for thrombus. RESULTS:Among this at-risk population (age 60 +/- 14 years; LVEF 32 +/- 11%), DE-CMR detected thrombus in 7% (55 patients) and cine-CMR in 4.7% (37 patients, p < 0.005). Follow-up was consistent with DE-CMR as a better reference standard than cine-CMR, including 100% detection among 5 patients with thrombus verified by pathology (cine-CMR, 40% detection), and logistic regression analysis testing the contributions of DE-CMR and cine-CMR simultaneously, which showed that only the presence of thrombus by DE-CMR was associated with follow-up end points (p < 0.005). Cine-CMR generally missed small intracavitary and small or large mural thrombus. In addition to traditional indices such as low LVEF and ischemic cardiomyopathy, multivariable analysis showed that increased myocardial scarring, an additional parameter available from DE-CMR, was an independent risk factor for thrombus. CONCLUSIONS:In a broad cross section of patients with systolic dysfunction, thrombus prevalence was 7% by DE-CMR and included small intracavitary and small or large mural thrombus missed by cine-CMR. Prevalence increased with worse LVEF, ischemic etiology, and increased myocardial scarring.
PMID: 18598895
ISSN: 1558-3597
CID: 4777332
Direct en face imaging of secundum atrial septal defects by velocity-encoded cardiovascular magnetic resonance in patients evaluated for possible transcatheter closure
Thomson, Louise E J; Crowley, Anna Lisa; Heitner, John F; Cawley, Peter J; Weinsaft, Jonathan W; Kim, Han W; Parker, Michele; Judd, Robert M; Harrison, J Kevin; Kim, Raymond J
BACKGROUND:Atrial septal defect (ASD) flow can be measured indirectly by velocity-encoded cardiovascular magnetic resonance (veCMR) of the pulmonary artery and aorta. Imaging the secundum ASD en face could potentially enable direct flow measurement and provide valuable information about ASD size, shape, location, and proximity to other structures. METHODS AND RESULTS/RESULTS:Forty-four patients referred for possible transcatheter ASD closure underwent a comprehensive standard evaluation, including transesophageal and/or intracardiac echocardiography and invasive oximetry. CMR was performed in parallel and included direct en face veCMR after an optimal double-oblique imaging plane was determined that accounted for ASD flow direction and cardiac-cycle interatrial septal motion. ASD flow measured by direct en face veCMR correlated better with invasive oximetry than indirect (pulmonary artery and aorta) veCMR (r=0.80 versus r=0.66). Additionally, 95% limits of agreement were narrower (+/-3.9 versus +/-5.1 L/min). En face veCMR determined that defects usually were eccentrically shaped (major/minor axis length >1.5) rather than circular, with 16% having extreme eccentricity (major/minor >2.0). Overall, ASD size by both veCMR and intracardiac echocardiography correlated with final device size; however, in small to medium defects (<3 cm(2)) and extremely eccentric defects, veCMR correlated better with final device size than did intracardiac echocardiography. Importantly, CMR identified additional information in 9 patients (20%) that altered clinical management. Specifically, en face veCMR detected additional defects (n=3), large ASD with insufficient rim tissue (n=2), and sinus venosus defect with anomalous pulmonary vein (n=1). Cine and/or morphological imaging detected interrupted inferior vena cava (n=2) and sinus of Valsalva aneurysm (n=1). CONCLUSIONS:En face veCMR with an optimized imaging plane can determine ASD flow, size, and morphology. CMR provided information incremental to comprehensive standard evaluation that altered clinical management in 20% of patients.
PMID: 19808512
ISSN: 1942-0080
CID: 4777372
Value of cardiovascular magnetic resonance stress perfusion testing for the detection of coronary artery disease in women
Klem, Igor; Greulich, Simon; Heitner, John F; Kim, Han; Vogelsberg, Holger; Kispert, Eva-Maria; Ambati, Srivani R; Bruch, Christian; Parker, Michele; Judd, Robert M; Kim, Raymond J; Sechtem, Udo
OBJECTIVES/OBJECTIVE:We wanted to assess the value of cardiovascular magnetic resonance (CMR) stress testing for evaluation of women with suspected coronary artery disease (CAD). BACKGROUND:A combined perfusion and infarction CMR examination can accurately diagnose CAD in the clinical setting in a mixed gender population. METHODS:We prospectively enrolled 147 consecutive women with chest pain or other symptoms suggestive of CAD at 2 centers (Duke University Medical Center, Robert-Bosch-Krankenhaus). Each patient underwent a comprehensive clinical evaluation, a CMR stress test consisting of cine rest function, adenosine-stress and rest perfusion, and delayed-enhancement CMR infarction imaging, and X-ray coronary angiography within 24 h. The components of the CMR test were analyzed visually both in isolation and combined using a pre-specified algorithm. Coronary artery disease was defined as stenosis > or =70% on quantitative analysis of coronary angiography. RESULTS:Cardiovascular magnetic resonance imaging was completed in 136 females (63.0 +/- 11.1 years), 37 (27%) women had CAD on coronary angiography. The combined CMR stress test had a sensitivity, specificity, and accuracy of 84%, 88%, and 87%, respectively, for the diagnosis of CAD. Diagnostic accuracy was high at both sites (Duke University Medical Center 82%, Robert-Bosch-Krankenhaus 90%; p = 0.18). The accuracy for the detection of CAD was reduced when intermediate grade stenoses were included (82% vs. 87%; p = 0.01 compared the cutoff of stenosis > or =50% vs. > or =70%). The sensitivity was lower in women with single-vessel disease (71% vs. 100%; p = 0.06 compared with multivessel disease) and small left ventricular mass (69% vs. 95%; p = 0.04 for left ventricular mass < or =97 g vs. >97 g). The latter difference was even more significant after accounting for end-diastolic volumes (70% vs. 100%; p = 0.02 for left ventricular mass indexed to end-diastolic volume < or =1.15 g/ml vs. >1.15 g/ml). CONCLUSIONS:A multicomponent CMR stress test can accurately diagnose CAD in women. Detection of CAD in women with intermediate grade stenosis, single-vessel disease, and with small hearts is challenging.
PMID: 19356464
ISSN: 1876-7591
CID: 4777352
A novel enhancement in the diagnostic performance of troponin I [Meeting Abstract]
Haq, Salman A; Tavakol, Morteza; Silber, Steven; Bernstein, Larry; Kneifati-Hayek, Jerard; Schlefer, Madeleine; Heitner, John F
ISI:000249589900048
ISSN: 0002-9173
CID: 2544362
Effects of comorbidities on cardiac troponin-T levels [Meeting Abstract]
Fleischman, William; Haq, Salman; Haines, Elizabeth J; Melniker, Larry A; Silber, Steven H; Heitner, John F; Kneifati-Hayek, Jerard; Bernstein, Larry H
ISI:000249589900049
ISSN: 0002-9173
CID: 2109482
Improved detection of coronary artery disease by stress perfusion cardiovascular magnetic resonance with the use of delayed enhancement infarction imaging
Klem, Igor; Heitner, John F; Shah, Dipan J; Sketch, Michael H; Behar, Victor; Weinsaft, Jonathan; Cawley, Peter; Parker, Michele; Elliott, Michael; Judd, Robert M; Kim, Raymond J
OBJECTIVES/OBJECTIVE:We tested a pre-defined visual interpretation algorithm that combines cardiovascular magnetic resonance (CMR) data from perfusion and infarction imaging for the diagnosis of coronary artery disease (CAD). BACKGROUND:Cardiovascular magnetic resonance can assess both myocardial perfusion and infarction with independent techniques in a single session. METHODS:We prospectively enrolled 100 consecutive patients with suspected CAD scheduled for X-ray coronary angiography. Patients had comprehensive clinical evaluation, including Rose angina questionnaire, 12-lead electrocardiography, C-reactive protein, and calculation of Framingham risk. Cardiovascular magnetic resonance included cine, adenosine-stress and rest perfusion-CMR, and delayed enhancement-CMR (DE-CMR) for infarction imaging. Matched stress-rest perfusion defects in the absence of infarction by DE-CMR were considered artifactual. All patients underwent X-ray angiography within 24 h of CMR. RESULTS:Ninety-two patients had complete CMR examinations. Significant CAD (> or =70% stenosis) was found in 37 patients (40%). The combination of perfusion and DE-CMR had a sensitivity, specificity, and accuracy of 89%, 87%, and 88%, respectively, for CAD diagnosis, compared with 84%, 58%, and 68%, respectively, for perfusion-CMR alone. The combination had higher specificity and accuracy (p < 0.0001), owing to incorporating the exceptionally high specificity (98%) of DE-CMR. Receiver operating characteristic curve analysis demonstrated the combination provided better performance than cine, perfusion, or DE-CMR alone. The accuracy was high in single-vessel and multivessel disease and independent of CAD location. Multivariable analysis including standard clinical parameters demonstrated the combination was the strongest independent CAD predictor. CONCLUSIONS:A combined perfusion and infarction CMR examination with a visual interpretation algorithm can accurately diagnose CAD in the clinical setting. The combination is superior to perfusion-CMR alone.
PMID: 16631001
ISSN: 1558-3597
CID: 4777302
Where's the flap? [Case Report]
Heitner, John; Lotfi, Mat; Harrison, J Kevin; Cabell, Christopher; Klem, Igor; Banko, Lesan; Kim, Raymond J; Califf, Robert M
We present a case of aortic intramural hematoma (IMH) in an elderly woman who presented with sudden onset of mid-scapular pain. The patient underwent a series of multimodality imaging studies before the diagnosis of IMH was evident by cardiovascular magnetic resonance, which is rapidly becoming the gold standard in the evaluation of acute aortic disease due to its high spatial resolution and ability to characterize tissue composition. Early diagnosis and prompt treatment is critical in improving the outcome of patients with IMH.
PMID: 16755845
ISSN: 1097-6647
CID: 4777312