Preoperative flexion contracture influences magnitude of planned resections in robotic-assisted total knee arthroplasty

Di Gangi, Catherine; Haruray, Saloni; Novikov, David; Meere, Patrick; Meftah, Morteza; Hepinstall, Matthew S
BACKGROUND:Varying degrees of flexion contracture appear commonly in total knee arthroplasty (TKA) patients and can be corrected using increasing distal femoral bone resection. Robotic-assisted (RA) technology aims to avoid ligament release through optimized bony resections. This study evaluated the influence of preoperative flexion contracture on the magnitude of resections surgeons perform to balance knees in RA-TKA. MATERIALS AND METHODS/METHODS:We reviewed 789 primary RA-TKAs from 2023 to 2024 using cruciate-retaining (CR) implants. The cohort was divided by native flexion deformity into three groups: <0° flexion ("hyperextension", n = 157), 0-9.9° flexion ("minimal contracture", n = 457), and ≥ 10° flexion ("clinically important contracture", n = 175). Mean preoperative flexion contracture was - 3.8, 4.1, and 13.5° for the hyperextension, minimal contracture, and clinically important contracture cohorts, respectively. Demographics, implants, and intraoperative data were collected and analyzed. The arithmetic hip-knee-ankle (aHKA) angle was used to determine native deformity groups for additional subanalyses. RESULTS:Significant differences were found between cohorts for mean distal femur and proximal tibia resections, with the clinically important contracture group having the largest resections. After accounting for implanted polyethylene thickness, differences in mean tibia resections were quite small, varying by 0.9 millimeters (mm) laterally and 0.7 mm medially. Similarly, the mean distal femoral resection varied by only 1.4 mm laterally and 0.7 mm medially between the hyperextension and clinically important contracture cohorts. Indeed, 85% of cases with clinically important contractures were managed with less than 2 mm of additional distal femoral resection compared to the minimal contracture cohort. CONCLUSION/CONCLUSIONS:With robotic-assisted TKA, bone resections can be guided by collateral ligament tension in flexion and extension. Our data suggest that surgeons can follow this strategy and successfully address flexion contractures with very small increases in resection magnitudes, which may help to maintain the joint line.
PMCID:12864318
PMID: 41627505
ISSN: 1434-3916
CID: 5999552

Validation of imageless navigation in total knee arthroplasty using a postoperative radiographic approach

Zabat, Michelle A; Fiedler, Benjamin; Muir, Jeffrey M; Marwin, Scott E; Meftah, Morteza; Schwarzkopf, Ran
INTRODUCTION/BACKGROUND:The integration of computer-assisted navigation systems (CASs) in total knee arthroplasty (TKA) procedures has gained popularity in recent years. However, additional validation of the accuracy of CAS feedback is necessary. We used short-length and full-length postoperative radiographs to quantify the differences between alignment parameters measured by a novel imageless CAS and alignment outcomes as evidenced on postoperative radiographs. MATERIALS AND METHODS/METHODS:A retrospective analysis was conducted on prospectively collected data from a cohort of patients undergoing navigated primary TKA. Fifty-eight patients had met inclusion criteria, and intraoperative CAS measurements were obtained from device recordings. Alignment parameters were measured digitally and included femorotibial angle on short-length films and hip-knee-ankle axis, mechanical lateral distal femoral angle (mLDFA), and mechanical medial proximal tibial angle (mMPTA) on full-length films. These were compared between CAS and radiograph measurements using a 2-tailed t test. RESULTS:The mean mLDFA measured by the CAS was 0.7° ± 1.1°, compared with 1.3° ± 1.4° as measured on full-body radiographs (P = .1). The mean mMPTA measured by the CAS was 0.2° ± 1.0°, compared with 0.9° ± 1.4° as measured on full-body radiographs (P = .06). On average, radiograph and CAS measurements differed by 0.5° ± 1.5° for mLDFA and 0.7° ± 1.5° for mMPTA. The average postoperative hip-knee-ankle axis was 177.6° ± 2.1°, and the average femorotibial angle was 176.0° ± 9.6° as measured on radiographs. CONCLUSION/CONCLUSIONS:No significant differences in either average or individual measured values for mLDFA or mMPTA were observed between the intraoperative CAS measurements and alignment outcomes postoperatively. Our data highlight the clinical utility of CASs to accurately achieve intended TKA alignment objectives.
PMCID:12742488
PMID: 41637612
ISSN: 2328-5273
CID: 6000192

Coronal Alignment Does Not Adequately Predict Femoral Rotation Axes in Total Knee Arthroplasty: Application of a 3D Image-Based Robotic-Assisted Arthroplasty Platform

Anil, Utkarsh; Di Gangi, Catherine; Anderson, Lachlan; Lin, Charles C; Hepinstall, Matthew; Meftah, Morteza; Arshi, Armin
(1) Introduction: Precise femoral component rotation is critical for achieving symmetric flexion-gap balance and physiologic patellofemoral tracking in mechanically aligned total knee arthroplasty (TKA). Surgeons often infer an appropriate rotational target from the patient's coronal limb alignment, yet the strength of this relationship remains uncertain. (2) Methods: We identified 695 consecutive patients undergoing primary TKA with a preoperative planning CT scan. The surgical transepicondylar axis (sTEA) and posterior condylar axis (PCAxis) were identified and the angle between them was measured. The angle between the mechanical axis of the femur and tibia was used to measure the coronal alignment of the limb. (3) Results: The mean sTEA was 3.0° externally rotated to the PCAxis (range 3.1° internal to 9.2° external). The mean coronal alignment was 4.3° varus (range -12.5° valgus to 24.5° varus). There were 465 patients with >2° varus and 101 patients with >2° valgus. The mean sTEA was 2.9 ± 1.9° externally rotated relative to the PCAxis in the valgus group and 2.8 ± 2.0° in the varus group, with no statistically significant difference (p = 0.7). (4) Conclusions: There is significant variation in the femoral rotation axes between patients, but no significant relationship between overall limb coronal alignment and the magnitude of femoral rotation axes variation. This reinforces the need for independent assessment of rotational landmarks when performing mechanically aligned TKA.
PMCID:12292550
PMID: 40722420
ISSN: 2306-5354
CID: 5903182

Does the Use of a Tourniquet Influence Five-Year Outcomes Following Total Knee Arthroplasty?

Katzman, Jonathan L; Sandoval, Carlos G; Roof, Mackenzie A; Rozell, Joshua C; Meftah, Morteza; Schwarzkopf, Ran
BACKGROUND:A tourniquet is commonly used during total knee arthroplasty (TKA) to improve surgical field visibility and minimize blood loss. While the short-term effects of tourniquet use on postoperative outcomes have been studied extensively and found to be minimal, its influence on longer-term outcomes remains underexplored. This study examined tourniquet use in TKA with up to five-year follow-up. METHODS:In this post hoc analysis of a randomized controlled trial, 227 patients who underwent primary TKA in the tourniquet (T) group (n = 112) or no tourniquet (NT) group (n = 115) were evaluated. Clinical outcomes and patient-reported outcome measures (PROMs) were compared between the two groups. RESULTS:The T group had non-significant trends toward reduced blood loss (131.8 versus 116.7 ml, P = 0.098) and shorter operative time (97.8 versus 95.7 minutes, P = 0.264), with slightly higher postoperative day-one Visual Analog Scale (VAS) pain scores (3.1 versus 3.6, P = 0.197). Length of stay (2.0 versus 2.1 days, P = 0.837) and home discharge rate (88.7 versus 92.0%, P = 0.340) were comparable. The NT group had three 90-day readmissions, while none occurred in the T group (2.7 versus 0%, P = 0.081). The active range of motion at the final follow-up was similar between groups (108.3 versus 106.5 degrees, P = 0.457). All-cause revision rates at five years were comparable between the NT and T groups (5.2 versus 3.6%, P = 0.546). Kaplan-Meier survivorship analysis revealed comparable aseptic implant survival at five years (P = 0.769). There were no significant differences in Knee injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS, JR), Patient-Reported Outcomes Measurement Information System (PROMIS) pain intensity, PROMIS pain interference, or PROMIS physical health scores at three months, one year, and five years postoperatively. CONCLUSION/CONCLUSIONS:Using a tourniquet during primary TKA was not associated with differences in clinical or patient-reported outcomes at up to five-year follow-up. These findings suggest that tourniquet use in TKA can be left to the surgeon's discretion.
PMID: 39557227
ISSN: 1532-8406
CID: 5758212

Is Tranexamic Acid Safe for Patients Who Have End-Stage Renal Disease Undergoing Total Joint Arthroplasty?

Huebschmann, Nathan A; Esper, Garrett W; Robin, Joseph X; Katzman, Jonathan L; Meftah, Morteza; Schwarzkopf, Ran; Rozell, Joshua C
BACKGROUND:Tranexamic acid (TXA) is a renally-excreted antifibrinolytic commonly utilized in total joint arthroplasty (TJA). This study examined whether TXA administration affected clinical outcomes and kidney function in patients who had end-stage renal disease (ESRD) undergoing TJA or hemiarthroplasty. METHODS:Through a retrospective chart review, we identified 123 patients: 40 who underwent primary elective total knee arthroplasty (TKA; 65% received TXA), 34 who underwent primary elective total hip arthroplasty (THA; 52.9% TXA), and 49 who underwent nonelective THA or hemiarthroplasty (44.9% TXA) from January 2011 to February 2024. All patients had ESRD and/or were on dialysis, with no difference in percentage on dialysis between TXA groups (TKA: 65.4 versus 64.3%; THA: 55.6 versus 50.0%; nonelective/hemiarthroplasty: 86.4 versus 85.2%, P values ≥ 0.586). Demographic and perioperative characteristics, including preoperative hemoglobin, TXA administration, dose, and route of administration (ROA; intravenous, topical), were extracted. Pre- and postoperative (≤ 7 days) creatinine, perioperative transfusions, revisions, and 90-day emergency department (ED) visits, readmissions, and mortalities were recorded and compared between TXA groups. RESULTS:In the total sample and all cohorts, change in pre- to postoperative creatinine and incidence of postoperative acute kidney injury (AKI), per Kidney Disease Improving Global Outcomes (KDIGO) guidelines, did not significantly differ based on receiving TXA (P values ≥ 0.159). Among patients receiving TXA, change in creatinine did not significantly differ by dose (P values ≥ 0.428) or ROA (P values ≥ 0.256). There were no statistically significant differences in 90-day ED visits, readmissions, or mortalities based on receiving TXA (P values ≥ 0.055). Thromboembolic events occurred in four patients (one TXA, three no TXA, P = 0.617), and perioperative transfusions occurred in two patients (one TXA, one no TXA, P = 0.882) in the nonelective/hemiarthroplasty cohort, with none in the elective cohorts. CONCLUSIONS:The administration of TXA does not portend a significant increase in complications for patients who have ESRD undergoing TJA or hemiarthroplasty for fracture, suggesting TXA should not be contraindicated in this population.
PMID: 39551400
ISSN: 1532-8406
CID: 5757952

Clinical and patient-reported outcomes of a novel robotic system in total knee arthroplasty

Khury, Farouk; Shichman, Ittai; Antonioli, Sophia; Rozell, Joshua; Meftah, Morteza; Schwarzkopf, Ran
BACKGROUND:Robotic assistance (RA) is increasingly used in total knee arthroplasty (TKA) for more accurate bony resection and balancing. However, the impact of robotic TKA (RATKA) on clinical outcomes and patient-reported measures (PROMs) remains unclear. This study aims to compare RATKA and conventional TKA (CTKA) using a novel robotic system. METHODS:A retrospective review was conducted on 10,031 patients who underwent TKA from February 2021 to October 2024. 289 RATKAs were performed with a hand-held robotic system. These RATKA cases were 1:1 propensity-score matched to CTKA for patient demographics, surgeon, implant system, and articulation design. Postoperative and clinical outcomes including surgical time, length of stay (LOS), discharge disposition, 90-day emergency department (ED) visits, manipulation under anesthesia (MUA), debridement, reoperations and revisions were collected and analyzed. Patient-reported outcomes measures (PROMs) included Knee Injury and Osteoarthritis Outcome Scores (KOOS, JR) and Patient Reported Outcome Measurement Information System (PROMIS) scores. RESULTS:RATKA demonstrated significantly shorter LOS (30.04 vs. 51.91 hours, p < 0.001, respectively) compared to CTKA. There was no difference in surgical time (107.18 vs. 106.22 minutes, p = 0.349). Although there was no statistical difference in 90-day ED visits, the majority of the CTKA revisits were due to surgery-related causes when compared to the RATKAs (1.38% vs. 0.34%, p = 0.239). While RATKAs had higher incidence of MUAs (2.07% vs. 0.34%, p = 0.201), CTKAs had more reoperations (1 vs. 0, p = 0.369) and more revisions than the RATKAs (6 vs. 0, p = 0.117). In terms of PROMs, both RATKAs and CTKAs showed similar improvements in KOOS, JR and PROMIS pain scores following TKA, with no significant differences in the magnitude of improvement at early postoperative timepoints. However, at the one-year follow-up, RATKA demonstrated significantly greater reduction in PROMIS pain intensity (Δ-9.12, p = 0.032) compared to CTKAs. CONCLUSIONS:This retrospective analysis showed that the novel RATKA resulted in reduced length of stay, fewer reoperations, and greater reduction in one-year PROMIS pain intensity compared to CTKAs, despite having a higher incidence of MUA rates. Further research is needed to clarify these differences clinically and enhance patient outcomes.
PMID: 40411644
ISSN: 1434-3916
CID: 5853842

Prediction of coronal alignment in robotic-assisted total knee arthroplasty with artificial intelligence

Bosco, Joseph; Wixted, Colleen M; Gangi, Catherine Di; Waren, Daniel; Meftah, Morteza
INTRODUCTION/BACKGROUND:Robotic-assisted technologies provide the ability to avoid soft tissue release by utilizing more accurate bony cuts during total knee arthroplasty (TKA). However, the ideal limb alignment is not yet established. The aim of this study was to predict postoperative Coronal Plane Alignment of the Knee (CPAK) using corresponding native bony measurements. METHODS:This study analyzed a retrospective cohort of 530 primary robotic-assisted TKAs. Machine learning was utilized to predict appropriate target lateral distal femoral angles (LDFA) and medial proximal tibial angles (MPTA). Normalization of LDFA and MPTA alignments was performed using the min-max scaler operation on the training set with feature range [-1, 1] and repeated separately for the input and target distributions. A neural network of hidden dimensions (16, 8, 4) was trained via supervised learning to predict planned LDFA and MPTA values from preoperative LDFA and MPTA measurements. RESULTS:The model converged after 104 epochs and batch size 4 with mean squared error ±1.82°. The model's regression agrees with the hypothesized change in preoperative to planned coronal alignment: valgus measurements are translated to neutral/aligned targets while varus alignments are translated to varus alignment of lesser severity. Evaluative statistics demonstrate this method for planning knee morphologies is significantly more accurate than making predictions about the mean (RMSE 1.440; R-squared 0.444; Nash Sutcliffe 0.579). CONCLUSION/CONCLUSIONS:This study's model provides accurate predictions for target knee alignment morphologies. Future work is warranted to evaluate this method's usefulness for planning robotic TKA.
PMID: 40286441
ISSN: 1873-5800
CID: 5830922

Ratio of Weight-to-Tibial Baseplate Surface Area in Predicting Aseptic Tibial Loosening in TKA and the Protective Effect of Tibial Stem Extensions

Huebschmann, Nathan A; Katzman, Jonathan L; Robin, Joseph X; Meftah, Morteza; Rozell, Joshua C; Schwarzkopf, Ran
BACKGROUND:High body mass index (BMI) is a risk factor for tibial baseplate loosening following total knee arthroplasty (TKA) but may not adequately correlate with stresses at the tibial baseplate. In this study, we aimed to determine an optimal cutoff of a weight-to-tibial baseplate surface-area ratio (weight/SA) for predicting aseptic tibial baseplate loosening. We further examined whether tibial stem extensions have a protective effect. METHODS:We identified 16,368 patients who underwent primary, elective TKA from June 2011 to March 2023. Patient demographics, including age, sex, and race, implants used, and revision surgeries were extracted. Revisions were manually reviewed to confirm revision indications. The exact surface areas of tibial baseplates were obtained from manufacturers. Receiver operating characteristic (ROC) analysis of patients without tibial stem extensions was utilized to examine the utility of BMI and weight/SA for predicting aseptic tibial baseplate loosening. Optimal weight/SA and BMI cutoffs for predicting loosening were determined. The effect of tibial stem extensions on loosening was then examined in patients at or above (n = 7,698; 3.7% with stem extension) and below (n = 8,670; 1.3% with stem extension) the determined weight/SA cutoff. RESULTS:There were 16,368 patients in the final sample (median age, 67 years; 68.9% female; 54.1% White). Weight/SA (area under the curve [AUC] = 0.653; p < 0.001) was a better predictor of aseptic tibial baseplate loosening requiring revision compared with patient BMI (AUC = 0.624; p < 0.001). The optimal weight/SA cutoff for predicting loosening was 0.0162 kg/mm2 (sensitivity = 0.747, specificity = 0.537). Multivariable logistic regression demonstrated that being at or above the weight/SA cutoff (odds ratio [OR] = 3.17; p < 0.001) but not the BMI cutoff (p = 0.911) was a significant predictor of revision for tibial baseplate loosening in patients without stem extensions. No cases of revision for aseptic tibial baseplate loosening in patients with stem extensions occurred either at or above or below the cutoff. The rate of revision for aseptic tibial baseplate loosening in patients without stem extensions was 0.3% for patients below and 1.0% for patients at or above the weight/SA cutoff. CONCLUSIONS:The ratio of weight-to-tibial baseplate surface area was more predictive of revision for aseptic tibial baseplate loosening following TKA compared with BMI alone. For patients with obesity with small tibial baseplate sizes, utilization of a tibial stem extension may protect against tibial loosening. LEVEL OF EVIDENCE/METHODS:Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
PMID: 40184472
ISSN: 1535-1386
CID: 5819422

Surgeon-patient Communication Using the Electronic Portal: Effect on Postoperative Outcomes and Patient-reported Outcome Measures Following Total Knee Arthroplasty

Alpert, Zoe; Habibi, Akram; Ward, Spencer A; Kennedy, Mitchell F; Meftah, Morteza; Cohen-Rosenblum, Anna; Schwarzkopf, Ran; Rozell, Joshua C
BACKGROUND/UNASSIGNED:Electronic medical record portals enable real-time communication between patients and surgeons after total knee arthroplasty (TKA). This study evaluated the impact of message timing and frequency on postoperative outcomes and patient-reported outcome measures (PROMs). MATERIALS AND METHODS/UNASSIGNED:We retrospectively reviewed 9,353 primary TKAs performed at a single academic institution. Of these, 1,219 patients sent messages within 2 weeks of surgery (early), 507 sent messages between 2 and 8 weeks (late), and 7,627 did not message. RESULTS/UNASSIGNED:< .001). There was no difference in PROMs regardless of message timing, and there was no association between the number of messages sent and perioperative outcomes or PROMs. CONCLUSION/UNASSIGNED:Older age and longer LOS were associated with less patient-initiated contact after TKA. Older patients may be less familiar with digital platforms and less likely to send messages. Early messaging may reflect heightened recognition of postoperative issues, enabling counseling or intervention and reducing readmissions. These findings underscore the importance of preoperative education and equitable access, though long-term effects of messaging warrant further study.
PMID: 41114691
ISSN: 1938-2367
CID: 5972962

Utilization of preoperative EOS imaging to prevent adverse events following total hip arthroplasty

Buehring, Weston; Prinos, Alana; Habibi, Akram A; Meftah, Morteza; Hepinstall, Matthew; Schwarzkopf, Ran
INTRODUCTION/UNASSIGNED:Previous studies have demonstrated the use of technology in total hip arthroplasty (THA) provided favorable outcomes. This study sought to describe the effect preoperative two-dimensional low-dose (2DLD) full-body radiographs had on the prevention of adverse outcomes following THA. METHODS/UNASSIGNED:We reviewed 11,814 cases of patients who underwent primary, elective THA from 2016 to 2021. Patient demographics and clinical data were compared between patients who did or did not have preoperative standing and sitting 2DLD images (29.5% vs. 70.5%, respectively) using Chi-squared test and multivariate logistic regressions. RESULTS/UNASSIGNED: < 0.001). Multivariate analysis demonstrated preoperative 2DLD images to be significantly associated with lower odds of dislocation, independent from surgical approach, coexisting spinal fusion, and utilization of dual-mobility implants. CONCLUSION/UNASSIGNED:Preoperative 2DLD images were independently associated with decreased risk for dislocations. Even in a higher risk cohort with spinal fusion, the rate of dislocation in the 2DLD cohort was significantly lower.
PMID: 39535154