Searched for: in-biosketch:true
person:shapim06
Cranial bypass for occlusive carotid dissection in osteogenesis imperfecta: illustrative case
Grin, Eric A; Baranoski, Jacob; Rutledge, Caleb; Wiggan, Daniel D; Chung, Charlotte; Raz, Eytan; Sharashidze, Vera; Shapiro, Maksim; Riina, Howard A; Zhang, Cen; Nossek, Erez
BACKGROUND:Osteogenesis imperfecta (OI) is a connective tissue disorder characterized by fragile bones and vascular fragility, increasing the risk of vessel dissection and potentially complicating endovascular intervention. The authors present the first case of cranial bypass in a patient with OI. OBSERVATIONS/METHODS:A 38-year-old male with OI type I presented with a symptomatic left internal carotid artery (ICA) occlusive dissection managed with endovascular revascularization and stenting. Follow-up surveillance imaging identified an incidental right ICA dissection, also treated with stenting. Four years later, the patient experienced new right hemispheric symptoms. He was found to have progressive right ICA dissection on best medical management. Following an unsuccessful restenting attempt, he underwent a successful double-barrel superficial temporal artery-to-middle cerebral artery (STA-MCA) bypass to restore cerebral perfusion with no perioperative complications. Six-month follow-up DSA confirmed a patent bypass with robust flow, and the patient remained asymptomatic 1 year postoperatively. LESSONS/CONCLUSIONS:STA-MCA bypass can serve as a viable and effective revascularization option in patients with OI, whose disease predisposes them to vascular dissection. In these high-risk patients, cranial bypass is a safe method for effective flow augmentation to hypoperfused brain regions when endovascular interventions fail. https://thejns.org/doi/10.3171/CASE25378.
PMCID:12362187
PMID: 40825243
ISSN: 2694-1902
CID: 5908822
Clinical Management of Cerebral Aneurysms-: Endosaccular
Raz, Eytan; Chung, Charlotte Y; Nossek, Erez; Sahlein, Daniel H; Sharashidze, Vera; Shapiro, Maksim
Although the concept of treating cerebral aneurysms by filling the sac from the inside (endosaccular) started many years ago first with detachable balloons and then coils, the use of a single metallic resheathable device acting as a flow disruptor is a much more recent innovation. The most studied device among these is certainly the WEB, which became part of standard clinical practice for treatment of wide-neck bifurcation aneurysms. This study reviews the most important features of the WEB device with a short summary of the most important literature. A small section at the end reviews also other endosaccular devices.
PMID: 40634004
ISSN: 1557-9867
CID: 5890962
Follow-up Imaging in Treated and Untreated Cerebral Aneurysms
Chung, Charlotte Y; Shapiro, Maksim; Nossek, Erez; Sharashidze, Vera; Rutledge, Caleb; Raz, Eytan
Imaging follow-up is an established component of intracranial aneurysm management that allows ongoing assessment of rupture risk and timely intervention to maintain protection from bleeding. Yet the frequency, duration, and imaging modality for follow-up vary widely. This review outlines contemporary imaging techniques and practice for follow-up of treated and untreated aneurysms, highlighting existing knowledge gaps and technical limitations that limit standardization. Updated evidence on the expected evolution and long-term outcome of common treatment strategies is presented to guide accurate reporting of radiological outcome after treatment and considerations regarding follow-up regimen.
PMID: 40634007
ISSN: 1557-9867
CID: 5890982
Clinical Management of Cerebral Aneurysms-Endoluminal
Shapiro, Maksim; Nossek, Erez; Sharashidze, Vera; Sahlein, Daniel H; Rutledge, Caleb; Baranoski, Jacob; Chung, Charlotte Y; Riina, Howard; Nelson, Peter Kim; Raz, Eytan
Definitive endoluminal reconstruction, widely known as flow diversion, revolutionized treatment of brain aneurysms. A range of targets, by location, size, etiology, and acuity, can be cured with an excellent risk/benefit profile. Requirement for effective antiplatelet state is balanced with superior treatment durability. Implant and delivery system technology continue to evolve. Some aneurysm types/locations remain undertreated. Maximizing efficacy while minimizing risks requires deep understanding of flow diversion principles, pathologic anatomy, endoluminal implants, delivery systems, and clinical management.
PMID: 40634005
ISSN: 1557-9867
CID: 5890972
The Role of AI-driven Volumetric Aneurysm Analysis in the Management of Cerebral Aneurysms
Sahlein, Daniel H; DeNardo, Andrew J; Amuluru, Krishna; Gibson, Daniel P; Raz, Eytan; Shapiro, Maksim; Payner, Troy D; Kulwin, Charles G; Shah, Kushal J
This article looks at the current state of aneurysm risk modeling, exploring the limitations of linear measurement. It reviews articles using Food and Drug Administration (FDA)-approved artificial intelligence-driven volumetric measurement tools both for evaluating potential aneurysm growth in patients being managed conservatively as well as in assessing morphologic change prerupture and postrupture. The challenges of defining the aneurysm boundary are explored, and a novel definition of aneurysm/parent artery interface is proposed.
PMID: 40634003
ISSN: 1557-9867
CID: 5890952
Neuroanatomy of the vertebrobasilar perforators: implications for aneurysm treatment
Raz, Eytan; Shapiro, Maksim; Nossek, Erez; Sahlein, Daniel H; Potts, Matthew B; Sharashidze, Vera; Chung, Charlotte; Rutledge, Caleb; Khawaja, Ayaz Mahmood; Riina, Howard A; De Leacy, Reade Andrew; Kvint, Svetlana; Nelson, Peter Kim
The anatomy of vertebrobasilar perforators has been widely studied in human cadavers, with most reports found in the neurosurgical literature. These arterial perforators are extremely hard to visualize consistently with traditional two-dimensional digital subtraction angiography, but are reliably visible with cross sectional cone beam CT techniques. A clear understanding of this specific neurovascular anatomy and pathology is essential for informed treatment decisions. This review analyzes the anatomy of vertebrobasilar perforators with a focus on practical implications for aneurysm treatment, particularly flow diversion.
PMID: 39488337
ISSN: 1759-8486
CID: 5747422
The Silk Vista Baby Study: A Multicenter Aneurysm Report From North America and Europe
Hanel, Ricardo A; de Toledo, Otavio F; De Oliveira Souza, Natalia V; Gutierrez-Aguirre, Salvador F; Killer-Oberpfalzer, Monika; Raz, Eytan; Shapiro, Maksim; Kass-Hout, Tareq; Hurley, Michael; Morsi, Rami Z; Srinivasan, Visish M; Jankowitz, Brian T; Davis, Pierce; Siddiqui, Adnan; Jaikumar, Vinay; Cortez, Gustavo M; Kass-Hout, Omar; Becske, Tibor; Grandhi, Ramesh; Kilburg, Craig; Lopes, Demetrius K; Ducruet, Andrew F; Elijovich, Lucas; Britz, Gavin; Toledo, Maria M; Seinfeld, Joshua; Starke, Robert M; Nogueira, Raul G; Bender, Matthew T; Kan, Peter T; Lazaro, Tyler; Benalia, Victor H C; Erazu, Fernanda R; Lara-Velazquez, Montserrat; Aghaebrahim, Amin; Sauvageau, Eric; Pereira, Vitor M
BACKGROUND AND OBJECTIVES/OBJECTIVE:The Silk Vista Baby (SVB) flow diverter (FD) stent (Balt SAS) is the first device designed for treating distally located brain aneurysms. It can be delivered through a 0.017-inch ID microcatheter, enabling access to small, distal vessels. The aim of this study was to evaluate the effectiveness, safety, technical success, occlusion rate, and clinical outcomes of the SVB device. METHODS:This retrospective, multicenter study included data from 18 centers from November 2023 to September 2024. Procedures were performed by experienced neurointerventionalists following institutional standards of care. Outcomes analyzed included effectiveness, safety, and aneurysm occlusion rates. Descriptive analyses and Pearson χ2 or Independent t-Test were used for statistical evaluation. RESULTS:A total of 95 patients, mean age 55.4 years, were included. A total of 31% of aneurysms were ruptured at admission. Most (58.3%) were located in the anterior circulation, and 45% had previous treatment, mainly coiling (69.4%). Complication rates were higher for ruptured aneurysms (24.1%) compared with unruptured ones (9.2%). Two deaths occurred, 1 (1.1%) related to the procedure. At discharge, 87% of patients had modified Rankin Scale ≤2. The latest follow-up showed overall complete/near-complete occlusion rates of 76.1%, with 81.14% for ruptured and 73.43% for unruptured aneurysms. Technical success was higher in unruptured cases (100% vs 93.1%). CONCLUSION/CONCLUSIONS:Our case series demonstrated the efficacy of the SVB with a high rate of technical success. The occlusion rates for ruptured cases are comparable with those of other FDs. However, the rates are lower for unruptured cases. This discrepancy is likely due to the characteristics of the aneurysms, particularly in the presence of side branches in bifurcation lesions. The SVB safety profile is similar to other FDs in unruptured cases, while the ruptured group presented more complications.
PMID: 40637427
ISSN: 1524-4040
CID: 5891022
Early experience with the Drivewire 24: a newly FDA-approved steerable microwire
Grin, Eric Alexander; Sharashidze, Vera; Chung, Charlotte; Baranoski, Jacob F; Rutledge, Caleb; Riina, Howard A; Shapiro, Maksim; Raz, Eytan; Nossek, Erez
BACKGROUND:The Drivewire 24 (DW24) is a newly FDA-cleared 0.024 inch steerable guidewire. Its proximally controlled deflectable tip allows for intravascular steering to facilitate selective navigation of diagnostic or therapeutic catheters. We present the first clinical experience with the DW24. METHODS:All neurointerventional procedures using the DW24 from October 2024 to April 2025 were retrospectively reviewed. Indications, procedural details, DW24 performance, wire-related complications, and operator feedback were assessed. RESULTS:27 procedures were performed utilizing the DW24. Indications included aneurysm (n=16), stroke (n=5), arteriovenous fistula or malformation (n=4), and diagnostic venography (n=2). Technical success was achieved in 92.6% of cases. Target vessels included the MCA, anterior cerebral artery, posterior cerebral artery, internal carotid artery segments, transverse sinus, and torcula. The device's radiopaque, hydrophilic distal tip aided fluoroscopic visibility, and the variable support enabled articulation across a range of aspiration and delivery catheters without requiring additional support devices. The DW24's steerability enabled access to challenging cerebrovascular anatomy, including one stroke case where conventional guidewires failed to reach a distal M2 occlusion. The DW24's intravascular steering also allowed for the delivery of catheters for Pipeline Embolization Device (PED) deployment and facilitated PED post-processing to improve wall apposition without requiring wire removal, reshaping, or balloon angioplasty. Operators observed a short learning curve. There were no device-related complications, though the wire's response to rotational force was a limitation. CONCLUSION/CONCLUSIONS:The DW24 demonstrated a high technical success rate with no device-related complications. Its versatility across catheter sizes and precise controllability facilitate navigating complex cerebrovasculature. Further studies should assess efficacy in larger cohorts across additional clinical scenarios.
PMID: 40541400
ISSN: 1759-8486
CID: 5871362
Use of carotid web angioarchitecture in stratification of stroke risk
Negash, Bruck; Wiggan, Daniel D; Grin, Eric A; Sangwon, Karl L; Chung, Charlotte; Gutstadt, Eleanor; Sharashidze, Vera; Raz, Eytan; Shapiro, Maksim; Ishida, Koto; Torres, Jose L; Zhang, Cen; Nakatsuka, Michelle A; Rostanski, Sara K; Rethana, Melissa J; Kvernland, Alexandra; Sanger, Matthew; Lillemoe, Kaitlyn; Allen, Alexander; Kelly, Sean; Baranoski, Jacob F; Rutledge, Caleb; Riina, Howard A; Nelson, Peter Kim; Nossek, Erez
OBJECTIVE:To validate the carotid web (CW) risk stratification assessment described in previous works within a larger cohort of patients with symptomatic and incidentally found asymptomatic CWs. METHODS:A retrospective analysis of our institution's electronic medical records identified all patients with a diagnosis of CW from 2017 to 2024. We included symptomatic patients and those with asymptomatic CWs, that is, incidentally found webs without history of stroke or transient ischemic attack. Patient charts were reviewed for demographics, imaging, comorbidities, and a diagnosis of stroke after diagnosis of asymptomatic CW. All angles were measured as described in previous work on a sagittal reconstruction of neck CT angiography in which the common carotid artery (CCA), external carotid artery, and internal carotid artery (ICA) were well visualized, together with the CW itself. Principal component analysis and logistic regression were performed to evaluate the association between high-risk angles and stroke risk. RESULTS: Twenty-six symptomatic and 26 asymptomatic patients were identified. Of note, the number of patients with hypertension, hyperlipidemia, and smoking history was 17 (65.0%), 16 (62.0%), and 8 (31.0%) for symptomatic patients and 18 (69.0%), 17 (65.0%), and 15 (58.0%) for asymptomatic patients. All angular measurements showed statistically significant associations with stroke status. The CCA-web-pouch angle showed the strongest association (p=2.07×10⁻⁴), followed by the CCA-pouch-tip angle (p=3.23×10⁻⁴), ICA-web-pouch angle (p=0.004), and ICA-pouch-tip angle (p=0.005). Each additional high-risk angle increased the odds of stroke by 9.47-fold (p<0.0001). The associated probability of stroke increased from 6.3% with no high-risk angles to 39.1% with one high-risk angle and further to 85.9% with two high-risk angles. The model demonstrated high sensitivity, correctly identifying 84.6% of positive cases, and high specificity, correctly identifying 88.5% of negative cases. The F1 score was 0.863, indicating good overall model performance. CONCLUSION: Given this successful stratification of CWs into high- and low-risk groups, the utilization of geometric CW parameters may play a role in improving patient selection for intervention in the setting of incidentally diagnosed CW. .
PMID: 40541402
ISSN: 1759-8486
CID: 5871372
Treatment of Acute Iatrogenic Cerebrovascular Injury Using Flow Diverter Stents
Grin, Eric A; Kvint, Svetlana; Raz, Eytan; Shapiro, Maksim; Sharashidze, Vera; Baranoski, Jacob; Chung, Charlotte; Khawaja, Ayaz; Pacione, Donato; Sen, Chandra; Rutledge, Caleb; Riina, Howard A; Nelson, Peter K; Nossek, Erez
BACKGROUND AND OBJECTIVES/OBJECTIVE:Iatrogenic cerebrovascular injury can cause intracranial hemorrhage and pseudoaneurysm formation, putting patients at high risk for postoperative bleeding. No consensus for management exists. This study describes endovascular treatment of these acute injuries with flow diverter stents. METHODS:Electronic medical records were retrospectively reviewed for injury type and etiology, timing of diagnosis, and endovascular management, including antiplatelet regimens, embolization results, and clinical outcome. RESULTS:Six patients were included. Three suffered an injury to the internal carotid artery, 1 suffered an injury to the left anterior cerebral artery, 1 suffered an injury to the right posterior cerebral artery, and 1 suffered an injury to the basilar artery. Four of the 6 injuries occurred during attempted tumor resection, 1 occurred during cerebrospinal fluid leak repair, and 1 occurred during an ophthalmic artery aneurysm clipping. All injuries resulted in pseudoaneurysm formation. Four were immediately detected on angiography; 2 were initially negative on imaging. Five were treated with a pipeline embolization device, and 1 was treated with a Silk Vista Baby. Two were treated with 2 pipeline embolization devices telescopically overlapped across the pseudoaneurysm. All devices deployed successfully. No pseudoaneurysm recurrence or rebleeding occurred. No parent artery occlusion or stenosis was observed, and complete pseudoaneurysm occlusion was observed in 4 patients (in 2 patients, follow-up imaging could not be obtained). CONCLUSION/CONCLUSIONS:With proper antiplatelet regimens, flow diverter stents can be used safely to successfully treat complex acute iatrogenic injuries. Early repeat angiogram is needed when immediate postinjury imaging does not discover the point of vessel injury.
PMID: 39311570
ISSN: 2332-4260
CID: 5802862